Plan Review Details - Permit 09050419
| Plan Review Stops For Permit 09050419 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-05-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-28 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-28 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-05-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-27 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-27 |
Time |
08:42 |
Sent To |
PC |
|
| Notes |
| 2009-05-27 08:50:29 | RESIDENTIAL (R3) RE-ROOFING BUILDING REVIEW SECOND | | | CHECKLIST. | | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009 | | | REVISIONS. | | | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON NOA 08-0827.18 | | | SUBMITTED. HIGHLIGHTED ASSEMBLY HAS A MAXIMUM DESIGN | | | PRESSURE OF -60PSF. THIS BUILDING IS LOCATED ON A | | | 140MPH WIND ZONE AREA AND THE DESIGN PRESSURES AT | | | PERIMETER AND CORNER AREAS ARE HIGHER THAN -60PSF. | | | THAT'S WHY NAIL ENHANCING IS REQUIRED. | | | ***NOTE: DESIGN PROFESSIONAL PERFORMING THE | | | CALCULATIONS TO TAKE INTO CONSIDERATION THAT ACCORDING | | | TO 2009 REVISIONS TO THE 2007 FLORIDA RESIDENTIAL CODE | | | THIS BUILDING IS LOCATED ON EXPOSURE C, NOT B. SEE | | | REVISIONS TO THE EXPOSURE CATEGORY ON SEC. R301 OF 2007 | | | FLORIDA RESIDENTIAL CODE. | | | | | | 2- NOA SUBMITTED IS INCOMPLETE. PROVIDE ALSO THE FIRST | | | PAGES OF NOA THAT CONTAINS ALL APPROVED COMPONENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-05-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-20 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-20 |
Time |
11:48 |
Sent To |
PC |
|
| Notes |
| 2009-05-20 11:50:29 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009 | | | REVISIONS. | | | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON NOA 07-1203.01 | | | SUBMITTED. | | | ***NOTE: DESIGN PROFESSIONAL DOING THE CALCULATIONS TO | | | TAKE INTO CONSIDERATION THE EXPOSURE CATEGORY AS | | | REQUIRED BY 2009 REVISIONS TO SEC. R301.2.1.4.3 OF 2004 | | | FLORIDA RESIDENTIAL CODE. WHAT USED TO BE CONSIDERED | | | EXPOSURE B, NOW MAY BE CONSIDERED EXPOSURE C. SEE 2009 | | | REVISIONS. | | | | | | 2- CLEARLY IDENTIFY ON PRODUCT APPROVAL SUBMITTED WHICH | | | APPROVED ASSEMBLY AND FASTENING OPTION IS GOING TO BE | | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES AND NAIL ENHANCING REQUIREMENTS OF GENERAL | | | LIMITATION #7. | | | | | | 3- CLARIFY IF RE-ROOFING ENTIRE ROOF OR ONLY A SMALL | | | PART OF THE ROOF. PERMIT APPLICATION CALLS FOR ONLY | | | 141SF OF ROOF TO BE REPLACED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-05-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-20 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-20 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
|