Plan Review Details - Permit 09050411
Plan Review Stops For Permit 09050411
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-08-06 Cont ID  
Sent By jgomez Date 2009-08-06 Time 16:56 Rev Time 0.00
Received By jgomez Date 2009-08-06 Time 16:36 Sent To  
Notes
2009-08-06 17:01:35BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR THE EXTERIOR DOORS AS SHOWN ON
 PLANS. PRODUCT APPROVAL MISSING ON PACKAGE SUBMITTED.
 ALSO, ENGINEER OF RECORD TO REVIEW PRODUCT APPROVAL
 PRIOR TO SUBMITTAL.
  
 2- NEED TO COMPLY WITH THE REQUIREMENTS OF WHOLE HOUSE
 FAN IF TAKING THE WHOLE HOUSE CREDIT IN THE ENERGY
 CALCULATIONS. SEE SEC. B4.1.4 OF 2009 REVISIONS TO THE
 CHAPTER 11 OF FLORIDA RESIDENTIAL CODE 2007.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-05 Cont ID  
Sent By jgomez Date 2009-06-05 Time 14:02 Rev Time 0.00
Received By jgomez Date 2009-06-05 Time 14:02 Sent To PC
Notes
2009-06-05 15:00:17RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009
 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 N1100.0 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 3- PROVIDE COMPLETE SPECIFICATIONS FOR CLOSING OF
 EXISTING GARAGE DOOR OPENING. SPECIFY BOTTOM AND TOP
 PLATES AND ALL FASTENERS. SPECIFY WALL SHEATHING
 FASTENING, ETC. WALL TYPE 3 ON SHEET 3.1 IS MISSING ALL
 THIS INFORMATION.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC TO VERIFY
 COMPLIANCE WITH THE DESIGN LOADS OF SEC. R301 2007
 FLORIDA RESIDENTIAL CODE.
  
 4- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) WINDOW MULLIONS. AND CLEARLY MARK ON PRODUCT
 APPROVAL DRAWINGS SPECIFIC MULLION SIZE AND FASTENERS
 TO VERIFY COMPLIANCE WITH THE CALCULATED DESIGN
 PRESSURES.
  
 B) ALL EXTERIOR DOORS AS SHOWN ON PLANS.
  
 C) STORM SHUTTERS SINCE SINGLE HUNG WINDOWS PRODUCT
 APPROVAL NOA 08-0527.15 SUBMITTED DOESN'T HAVE ANY
 IMPACT RATING. PROVIDE COMPLETE INSTALLATION SCHEDULE.
 SEE ATTACHED SAMPLE. AND, CLEARLY MARK ON SHUTTERS
 DRAWINGS SPECIFIC MOUNTING CONDITIONS (EG: WALL
 MOUNTED, BUILT OUT, ETC) AND SPECIFIC ANCHOR TO BE USED
 ACCORDING TO THE SUBSTRATE TO BE ATTACHED TO (EG:
 CONCRETE, CONCRETE BLOCK OR WOOD).
  
 D) ALUMINUM ROOF PANELS TO BE USED.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY
 AMENDMENTS TO FBC.
 ***NOTE: RUBBER STAMP USED ON WINDOW PRODUCT APPROVAL
 IS NOT ACCEPTABLE BECAUSE IT DOENS'T IDENTIFY THE
 ENGINER WHO REVIEWED THE PLANS. IT ONLY SAYS THAT
 PRODUCT APRPOVAL WAS REVIEWED WITHOUT IDENTIFYING THE
 ENGINEER WHO REVIEWED IT.
  
 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. REVISE VALUATION TO INCLUDE ALL LABOR AND
 MATERIALS. ALSO, INCLUDE ALL PROFESSIONAL FEES AS
 REQUIRED BY SEC. R108.3 CITY AMENDMENTS TO FBC.
  
 7- ENGINEER OF RECORD TO SIGN AND SEAL SHEET 1.0 AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTE.
  
 8- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD
 (561)233-5120) TO CHECK IF IMPACT FEES ARE DUE. BRING
 BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE
 DUE.
 ***NOTE: COORDINATE WITH ZONING TO SEE IF PROPOSED
 APARTMENT IS ALLOWED. SEE ZONING COMMENTS.
  
 9- SHEET 4.0: REVISE BUILDING EXPOSURE. ACCORDING TO
 2009 REVISIONS TO 2007 FLORIDA RESIDENTIAL CODE THIS
 BUILDING IS LOCATED ON EXPOSURE "C", NOT "B". REVISE
 ALL DESIGN PRESSURES ACCORDINGLY. SEE 2009 REVISIONS TO
 SEC. R301 REGARDING BUILDING EXPOSURE.
 ***NOTE: CHECK SIZE OF BEAMS SPECIFIED ON PLANS TO
 VERIFY COMPLIANCE WITH THE EXPOSURE C DESIGN PRESSURES
 AND COLUM SPACING AS REQUIRED BY TABLE 502E OF EXPOSURE
 C TABLES FROM THE ALUMINUM ASSOCIATION MANUAL
 REFERENCED ON CHAPTER 20 OF FBC 2007.
  
 10- SHEET 7.0. CLARIFY WHY DESIGN CRITERIA ON LEFT SIDE
 OF SHEET REFERENCES BUILDING EXPOSURE "C", WHILE
 ALUMINUM DESIGN CRITERIA ON RIGHT SIDE OF SHEET
 REFERENCES BUILDING EXPOSURE "B". REVISE AS REQUIRED TO
 MATCH. AND REVISE ALL DESIGN PRESSURES ACCORDINGLY.
 COORDINATE WITH ITEM #9 ABOVE.
  
 11- COVER PAGE SITE PLAN IDENTIFYIES A PROPERTY ON
 BUNKER RD. THIS PROPERTY IS LOCATED ON FRANCIS ST. NO
 BUNKER RD. REVISE AS REQUIRED.
  
 12- SHEET 3.2: CLARIFY WHY THE WINDOW AND DOOR SCHEDULE
 CALL FOR MAX. AND MIN. WIND PRESSURES INSTEAD OF
 NEGATIVE AND POSITIVE PRESSURES.
  
 13- SHEET 4.1: PROVIDE ENGINEERING ANALYSIS SHOWING WHY
 THE WALL HEADER RECEIVING ENTIRE ROOF ON DETAIL 2 IS
 ATTACHED TO EXISTING PLYWOOD SHEATHING INSTEAD OF THE
 STUDS. SEC. 106.1.2 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-08-04 Cont ID  
Sent By btrobaug Date 2009-08-04 Time 11:09 Rev Time 0.00
Received By btrobaug Date 2009-08-04 Time 11:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-05-27 Cont ID  
Sent By btrobaug Date 2009-05-27 Time 15:19 Rev Time 0.00
Received By btrobaug Date 2009-05-27 Time 15:12 Sent To  
Notes
2009-05-27 15:19:08 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK
 MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002
 FAC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-22 Cont ID  
Sent By lmartine Date 2009-07-22 Time 15:26 Rev Time 0.00
Received By lmartine Date 2009-07-22 Time 15:26 Sent To  
Notes
2009-07-22 15:28:05R-11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-05 Cont ID  
Sent By jgomez Date 2009-06-05 Time 15:22 Rev Time 0.00
Received By jgomez Date 2009-05-19 Time 13:59 Sent To  
Notes
2009-05-20 14:15:53R-5

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-08-07 Cont ID  
Sent By kstevens Date 2009-08-07 Time 10:10 Rev Time 0.00
Received By kstevens Date 2009-08-07 Time 10:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-05-28 Cont ID  
Sent By kstevens Date 2009-05-28 Time 11:06 Rev Time 0.00
Received By kstevens Date 2009-05-28 Time 11:06 Sent To  
Notes
2009-05-28 11:25:21DENIED
 REFERENCE:
 FBC-2007 W/2009 SUPPLEMENTS
 FBC-2007 CHAPTER 1
 FBC-2007 PLUMBING
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. THE INDEX OF DRAWINGS DOES NOT REFLECT THE SHEETS
 SUBMITTED. PLEASE CORRELATE. SECTION 106.1.3.
  
 2. SHT 3.0 NOT SUBMITTED ONE SET OF PLANS. SECTION
 106.1. TWO SETS OF PLANS REQUIRED.
  
 3. SOME SHEETS ARE NOT SIGNED, SEALED AND DATED AS
 REQUIRED IN FAC 61G15-23.002(2) & FS 471.025. PLEASE
 SIGN, SEAL & DATE ALL SHEETS PREPARED BY THE DESIGN
 PROFESSIONAL.
  
 4. SHTS 3.0 & 9.0 INDICATE THE DESIGN TO BE PER
 FBC-2004 W/2007 AMENDMENTS. THE CODE CYCLE IN EFFECT
 SINCE MARCH 1, 2009 IS THE FBC-2007 W/2009 SUPPLEMENTS.
 PLEASE SHOW THE CORRECT CODE CYCLE FOR THE PLANS
 SUBMITTED.
  
 5. SHTS 7.0 & 9.0 THE CERTIFICATE OF AUTHORIZATION
 NUMBER IS REQUIRED IN THE TITLE BLOCK OF ALL SHEETS.
 THE NUMBER IS MISSING FROM THE TITLE BLOCK OF THESE
 SHEETS. FAC 61G15-23.002(2) & FS 471.025.
  
 6. ALL SHEETS WITH S.W. ENGINEERING INC. TITLE BLOCKS.
 THE ADDRESS IS REQUIRED IN THE TITLE BLOCK. THE ADDRESS
 INDICATED DOES NOT REFLECT THE ADDRESS OF RECORD IN THE
 STATE OF FLORIDA DEPT OF BUSINESS AND PROFESSIONAL
 REGULATION, (DBPR). PLEASE UPDATE THE TITLE BLOCKS OR
 THE DBPR WEBSITE PRIOR TO RESUBMITTING FOR REVIEW IN
 THE CITY OF WPB. FAC 61G15-23.002(2) & FS 471.025.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2009-07-28 Cont ID  
Sent By mcruz Date 2009-07-28 Time 14:06 Rev Time 0.00
Received By mcruz Date 2009-07-28 Time 13:40 Sent To  
Notes
2009-07-28 13:46:24AS NOTED ON PLAN, GAME ROOM SHALL NOT BE USED AS A
 DWELLING UNIT. NO 220 V CONNECTIONS NOR A RENTAL
 LICENSE SHALL BE APPROVED IN FUTURE.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 PLACED IN R11
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-05-31 Cont ID  
Sent By mcruz Date 2009-05-31 Time 15:43 Rev Time 0.00
Received By mcruz Date 2009-05-31 Time 15:37 Sent To  
Notes
2009-05-31 15:43:14PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. ACCESSORY APARTMENTS OR "MOTHER IN LAW" APARTMENTS
 ARE NOT ALLOWED WITHIN THE SINGLE-FAMILY LOW DENSITY
 (SF7) RESIDENTIAL DISTRICT (THE ZONING DISTRCIT OF THE
 SUBJECT SITE). PURSUANT TO THE CITY OF WEST PALM BEACH
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-303: ACCESSORY APARTMENTS PERMITTED WITH EXTRA
 REQUIREMENTS.
 ....
 (A) ADDITIONAL APPLICATION REQUIREMENTS.
  
 1. ONLY PERMITTED IN A SINGLE-FAMILY HIGH DENSITY
 (SF14) RESIDENTIAL ZONING DISTRICT.
  
 2. MINIMUM LOT AREA: 6,000 SQUARE FEET
  
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 PLACED BACK IN R5