Plan Review Details - Permit 09050383
Plan Review Stops For Permit 09050383
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2009-10-28 Cont ID  
Sent By jgomez Date 2009-10-28 Time 14:21 Rev Time 0.00
Received By jgomez Date 2009-10-28 Time 14:21 Sent To PC
Notes
2009-10-28 14:22:29REAR PORCH REVISION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2009-10-06 Cont ID  
Sent By jgomez Date 2009-10-06 Time 15:36 Rev Time 0.00
Received By jgomez Date 2009-10-06 Time 14:57 Sent To Z
Notes
2009-10-06 15:41:32REVISION CHECKLIST:
  
 1- OWES $74.16 FOR UPDATED VALUATION AND RADON FEES FOR
 NEW ROOF ADDITION.
  
 2- ROOF FRAMING PLAN ON SHEET 5.4 SUBMITTED INDICATES
 SECTIONS DETAILS ON SHEET 5.5. NEED TO PROVIDE SHEET
 5.5 SHOWING THE KEYED DETAILS. THIS SHEET WAS NOT
 SUBMITTED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-08-07 Cont ID  
Sent By jgomez Date 2009-08-07 Time 10:38 Rev Time 0.00
Received By jgomez Date 2009-08-07 Time 10:38 Sent To PC
Notes
2009-08-07 10:39:19IMPACT FEES PAID.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date 2009-08-05 Cont ID  
Sent By jgomez Date 2009-08-05 Time 08:39 Rev Time 0.00
Received By jgomez Date 2009-08-05 Time 08:39 Sent To PC
Notes
2009-08-05 08:40:23NEEDS IMPACT FEES STAMP AND COPY OF PAID RECEIPT. ALSO,
 NEEDS NOTICE OF COMMENCEMENT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date 2009-08-05 Cont ID  
Sent By jgomez Date 2009-07-15 Time 17:00 Rev Time 0.00
Received By jgomez Date 2009-07-15 Time 17:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-01 Cont ID  
Sent By jgomez Date 2009-06-01 Time 08:30 Rev Time 0.00
Received By jgomez Date 2009-06-01 Time 08:29 Sent To  
Notes
2009-06-01 09:09:49RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009
 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD
 (561)233-5120) TO VERIFY IF IMPACT FEES ARE DUE. BRING
 BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE
 DUE.
  
 3- PRODUCT APPROVALS SUBMITTAL:
 A) SINGLE HUNG WINDOWS FLORIDA PRODUCT APPROVAL FL10190
 SUBMITTED IS FOR 2004 CODE VERSION. NEED 2007 CODE
 VERSION.
 NOTE: NOA 06-1121.14 MAY BE SUBMITTED ALONE.
  
 B) GLASS BLOCK FLORIDA PRODUCT APPROVAL FL1363-R3 IS
 FOR 2004 CODE VERSION. NEED 2007 CODE VERSION. IN
 ADDITION NOA 07-0626.10 SUBMITTED IS FOR SMALL MISSILE
 IMPACT. PRODUCT APPROVAL NEED TO MEET THE REQUIREMENTS
 OF LARGE MISSILE IMPACT AS REQUIRED BY SEC. R301.2.1.2
 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 C) SINGLE OUTSWING DOOR FLORIDA PRODUCT APPROVAL
 FL539-R4 IS FOR 2004 CODE VERSION. NEED 2007 CODE
 VERSION.
 NOTE: NOA 08-0208.07 MAY BE SUBMITTED ALONE.
  
 D) FRENCH DOORS FLORIDA PRODUCT APPROVAL FL6747 IS FOR
 2004 CODE VERSION. NEED 2007 CODE VERSION. IN ADDITION
 NOA 05-1003.09 SUBMITTED EXPIRED ON APRIL 22, 2009.
 NEED CURRENT NOA.
  
 4- SHEET 1.0:
 A) DEMOLITION PLAN NOTE H REFERS TO "REMOVE EXISTING
 BEAM & ROOF ABOVE" BUT DEMOLITION PLAN SHOWS NOTE H ON
 EXISTING WINDOWS. REVISE/CLARIFY AS REQUIRED TO MATCH.
  
 B) SPECIFY TYPE OF EXISTING WINDOW TO BE REPLACED TO
 VERIFY COMPLIANCE WITH EGRESS REQUIREMENTS OF SEC.
 601.2 OF 2007 FLORIDA EXISTING BUILDING CODE.
  
 5- SHEET 5.0: REVISE THICKNESS OF STUCCO FINISH ON
 DETAIL 1/5.0. MIN. THICKNESS IS 7/8" AS REQUIRED BY
 TABLE R702.1(1) OF 2007 FLORIDA RESIDENTIAL CODE.
  
 6- SHEET 10.0:
 A) EXTERIOR GLAZED OPENINGS NOTE IS REFERENCING 2004
 FBC. NEED TO REFERENCE THE 2007 FLORIDA RESIDENTIAL
 CODE WHICH IS THE CURRENT CODE.
  
 B) REVISE CORNER DISTANCE A DIMENSION. SEE FIGURE
 R301.2(7) AND FIGURE R803.2.3.1 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-17 Cont ID  
Sent By btrobaug Date 2009-07-17 Time 10:56 Rev Time 0.00
Received By btrobaug Date 2009-07-17 Time 10:27 Sent To M
Notes
2009-07-17 10:57:36 
  
 TO RONS DESK FROM WHENCE IT CAME./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-05-27 Cont ID  
Sent By btrobaug Date 2009-05-27 Time 14:55 Rev Time 0.00
Received By btrobaug Date 2009-05-27 Time 14:35 Sent To  
Notes
2009-05-27 14:55:21 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK
 MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002
 FAC.
  
 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1), ONE MUST BE ADDED IN BATH
 #2 TO COMPLY.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-10-26 Cont ID  
Sent By jgomez Date 2009-10-26 Time 14:42 Rev Time 0.00
Received By jgomez Date 2009-10-26 Time 14:42 Sent To  
Notes
2009-10-26 14:43:21SENT TO J. GOMEZ'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-10-06 Cont ID  
Sent By lmartine Date 2009-10-05 Time 09:54 Rev Time 0.00
Received By lmartine Date 2009-10-05 Time 09:53 Sent To  
Notes
2009-10-06 09:54:26GAVE TO JULIO

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-07-30 Cont ID  
Sent By jwitmer Date 2009-07-30 Time 08:41 Rev Time 0.00
Received By jwitmer Date 2009-07-30 Time 08:41 Sent To  
Notes
2009-07-30 08:42:54INCOMING TO RON R.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-06-24 Cont ID  
Sent By shill Date 2009-06-24 Time 14:38 Rev Time 0.00
Received By shill Date 2009-06-24 Time 14:38 Sent To  
Notes
2009-06-24 14:38:25R12
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-04 Cont ID  
Sent By rregueir Date 2009-06-04 Time 09:16 Rev Time 0.00
Received By rregueir Date 2009-05-19 Time 13:01 Sent To PC
Notes
2009-05-20 13:10:44R-2

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2009-08-07 Cont ID  
Sent By jgomez Date 2009-08-07 Time 10:39 Rev Time 0.00
Received By jgomez Date 2009-08-07 Time 10:39 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 2 Status N Date 2009-10-21 Cont ID  
Sent By ajones Date 2009-10-21 Time 10:44 Rev Time 0.00
Received By ajones Date 2009-10-21 Time 10:44 Sent To  
Notes
2009-10-21 10:45:42APPLICANT PROVIDED PROOF THAT VALUE OF WORK DOES NOT
 EXCEED 50% OF THE VALUE OF THE STRUCTURE. 10/21/09

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-10-15 Cont ID  
Sent By rkussner Date 2009-10-15 Time 10:23 Rev Time 0.00
Received By rkussner Date 2009-10-15 Time 10:23 Sent To B
Notes
2009-10-15 10:42:21***LANDSCAPE REVIEW FAILED***
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. PURSUANT TO SECTION 94-441 (B), THE LANDSCAPING
 REQUIREMENTS SHALL APPLY WHEN REVONVATIONS, REPAIR,
 ALTERATION OR REDEVELOPMENT EXCEEDS 50 PERCENT OF THE
 VALUE OF THE STRUCTURE. PLEASE SUBMIT A COMPLETE
 LANDSCAPE PLAN AND THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 2. SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST
 OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO
 UNIT COST.
  
 3. ALL ITEMS LISTED IN SECTION 94-448 (D), SHALL BE
 INCLUDED AS PART OF THE LANDSCAPE PLAN.
  
 4. PURSUANT TO SECTION 94-445 (4)(G)(3), AUTOMATIC
 IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED
 LANDSCAPE AREAS FOR ALL PROPERTIES. ALL AREAS,
 INCLUDING THE RIGHT-OF-WAY, SHALL RECEIVE 120%
 COVERAGE.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2009-08-04 Cont ID  
Sent By rregueir Date 2009-08-04 Time 10:22 Rev Time 0.00
Received By rregueir Date 2009-08-04 Time 10:22 Sent To B
Notes
2009-08-04 10:22:31RESUBMITTED ENERGY CALCS OK

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2009-07-28 Cont ID  
Sent By rregueir Date 2009-07-28 Time 13:39 Rev Time 0.00
Received By rregueir Date 2009-07-14 Time 15:35 Sent To  
Notes
2009-07-28 13:39:51PLANS HAVE BEEN HELD AT MY DESK AFTER MULTIPLE ATTEMPTS
 TO GET CORRECTED ENERGY CALCULATIONS FROM THE DESIGN
 TEAM BY EMAIL OR DELIVERED IN PERSON. PLANS ARE NOW
 DENIED AND WILL NEED TO BE RESUBMITTED WITH CORRECTED
 ENERGY CALCULATIONS. OUTSTANDING ISSUES ON THE ENERGY
 CALCULATIONS ARE AS FOLLOWS:
  
 1. CALCULATIONS CALL FOR "FACTORY SEALED AIR HANDLER
 CREDIT." THE AIR HANDLER IS EXISTING AND NO SUCH CREDIT
 IS AVAILABLE. REVISE CALCULATIONS REMOVING THIS CREDIT.
  
 2. LINE 15 CALLS FOR A WHOLE HOUSE FAN CREDIT. THIS
 HOUSE MUST DEMONSTRATE THAT THE CRITERIA STATED IN
 FBC-R SECTION N1107.A.6 HAVE BEEN MET TO TAKE THIS
 CREDIT. PROVIDE SUCH DOCUMENTATION OR REMOVE THIS
 CREDIT FROM THE CALCULATIONS AND RESUBMIT.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-06-04 Cont ID  
Sent By rregueir Date 2009-06-04 Time 09:15 Rev Time 0.00
Received By rregueir Date 2009-06-04 Time 08:56 Sent To PC
Notes
2009-06-04 09:15:53REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENT
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. UPDATE CODE REFERENCE ON PAGE 9.0. THE CURRENT CODE
 IN EFFECT AS OF MARCH 1, 2009 IS THE 2007 FLORIDA
 BUILDING CODE W/ 2009 SUPPLEMENT.
  
 2. THE PROPOSED SCOPE OF WORK REPRESENTS AN INCREASE IN
 THE CONDITIONED FLOOR AREA WHICH IS DEFINED AS AN
 ADDITION PER FBC-R SECTION N1100.7.3. ADDITIONS TO
 EXISTING RESIDENTIAL BUILDINGS SHALL BE CONSIDERED NEW
 BUILDING CONSTRUCTION AND SHALL COMPLY WITH THE
 REQUIREMENTS OF EITHER METHOD A OR B AS APPLICABLE IN
 ACCORDANCE WITH FBC-R SECTION N1100.0.3. PROVIDE EITHER
 FORM 1100A-08 OR 1100B-08 COMPLIANCE FORM TO
 DEMONSTRATE ENERGY CODE COMPLIANCE.
  
 3. SHOW MEANS AND LOCATION OF DRYER EXHAUST IN
 ACCORDANCE WITH FBC-R SECTION M1502.
 NOTE: CHECK DRYER MANUFACTURER'S INSTALLATION
 INSTRUCTIONS FOR MAKEUP AIR REQUIREMENTS, WHICH WILL
 NEED TO BE IN PLACE AT TIME OF FINAL INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-07-09 Cont ID  
Sent By kstevens Date 2009-07-09 Time 11:29 Rev Time 0.00
Received By kstevens Date 2009-07-09 Time 11:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-05-22 Cont ID  
Sent By kstevens Date 2009-05-22 Time 14:22 Rev Time 0.00
Received By kstevens Date 2009-05-22 Time 14:22 Sent To  
Notes
2009-05-22 14:35:22DENIED
 REFERENCE:
 FBC-2007 W/2009 SUPPLEMENTS
 FBC-2007 RESIDENTIAL
 FBC-2007 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ALL SHEETS WITH S.W. ENGINEERING INC. TITLE BLOCKS
 SHALL INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER
 IN THE TITLE BLOCK PER FAC 61G15-23.002(2) & FS
 471.025. -- ALSO THE ADDRESS IN THE TITLE BLOCK DOES
 NOT REFLECT THE ADDRESS OF RECORD ON THE STATE OF
 FLORIDA DEPT OF BUSINESS & PROFESSIONAL REGULATION,
 (DBPR), WEBSITE. PLEASE UPDATE THE TITLE BLOCKS OR THE
 DBPR WEBSITE PRIOR TO RESUBMITTING PLANS TO THE CITY
 WPB FOR REVIEW. (SEE ATTACHED SHEET).
  
 2. SHT 8.0 MANY REFERENCES TO FBC-2004 EDITION IN THE
 PLUMBING NOTES. ALL APPLICATIONS FOR PERMIT ON OR AFTER
 MARCH 1, 2009 SHALL BE DESIGNED TO THE FBC-2007
 EDITION. PLEASE UPDATE THE DESIGN REFERENCES TO THE
 CURRENT CODE CYCLE.
  
 3. SHT 8.0 THE WATER CLOSET IS NOT VENTED AS INDICATED.
 SECTION P3101.2.1. (SEE RED LINE EXAMPLE OF PIPING FOR
 W/C).
  
 4. SHT 8.0 CLEANOUTS ARE REQUIRED NEAR THE JUNCTION OF
 THE BUILDING DRAIN AND THE BUILDING SEWER. SECTION
 P3005.2.7. THE W/C DRAIN LINE AND THE LAVS/SHOWER DRAIN
 LINES REQUIRE CLEANOUTS AS THEY EXIT THE BUILDING.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2009-05-31 Cont ID  
Sent By mcruz Date 2009-05-31 Time 15:20 Rev Time 0.00
Received By mcruz Date 2009-05-31 Time 15:08 Sent To B
Notes
2009-05-31 15:20:37TTHE VALUE OF THE PROPOSED INTERIOR WORK DOES NOT
 EXCEED 50% OF THE IMPROVEMENT VALUE.
  
 PATIO MEETS SETBACK DIMENSIONS.
  
 PLACED BACK ON JG'S DESK.