Plan Review Details - Permit 09050271
Plan Review Stops For Permit 09050271
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-06-29 Cont ID  
Sent By shill Date 2009-06-29 Time 10:32 Rev Time 0.00
Received By shill Date 2009-06-29 Time 10:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-05-15 Cont ID  
Sent By shill Date 2009-05-15 Time 13:12 Rev Time 0.00
Received By shill Date 2009-05-15 Time 13:12 Sent To  
Notes
2009-05-15 13:23:20****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. THE PRODUCT APPROVAL SUBMITTED IS EXPIRED, 2004 CODE
 RATHER THAN 2007. FAC9B-72.
  
 2. 3350PSI CONCRETE REQUIRED. FLOOR MOUNT WAS
 SPECIFIED; HOW HAVE YOU DETERMINED THAT THE CONCRETE
 HAS MET THIS REQUIREMENT, WHEN PATIO SLABS ARE
 TYPICALLY 2500PSI? EITHER PROVIDE EVIDENCE THAT THE
 CONCRETE MEETS MINIMUM STRENGTH REQUIREMENT OR USE
 CONCRETE BLOCK ANCHOR SPACING CHART.
  
 3. IT APPEARS THAT THIS PARCEL IS LOCATED IN EXPOSURE
 C. PLEASE SEE FBC R301, FBC1609, ASCE7-05.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-06-26 Cont ID  
Sent By shill Date 2009-06-26 Time 14:26 Rev Time 0.00
Received By shill Date 2009-06-26 Time 14:26 Sent To  
Notes
2009-06-26 14:26:18TO SMH DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-05-15 Cont ID  
Sent By shill Date 2009-05-15 Time 13:23 Rev Time 0.00
Received By shill Date 2009-05-15 Time 13:23 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved