Plan Review Details - Permit 09050149
Plan Review Stops For Permit 09050149
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-05-15 Cont ID  
Sent By jwitmer Date 2009-05-15 Time 14:45 Rev Time 0.77
Received By jwitmer Date 2009-05-15 Time 14:00 Sent To  
Notes
2009-05-15 14:26:42BUILDING PROVISO:
 SINK TO COMPLY WITH 11-4.24.2 HEIGTH OF 34".

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-05 Cont ID  
Sent By dpalmer Date 2009-07-05 Time 14:29 Rev Time 0.00
Received By dpalmer Date 2009-07-05 Time 14:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-05-18 Cont ID  
Sent By dpalmer Date 2009-05-18 Time 16:32 Rev Time 0.00
Received By dpalmer Date 2009-05-18 Time 16:32 Sent To  
Notes
2009-05-18 16:32:27**DENIED REVIEW **
  
 1) NOTE: PLEASE LIST THE FOLLOWING CODES: AS OF
 DECEMBER 31ST 2008, FAC 69A-60.004 ADOPTED THE 2006
 NFPA-101. THE ELECTRICAL PLANS STATE THE 2003 EDITION.
 PER THE ELECTRICAL PLANS, THE EDITION OF NFPA-70 STATES
 THE 2008 EDITION. THE STATE OF FLORIDA ADOPTED THE 2005
 EDITION OF NFPA-70 ON DECEMBER 8TH, 2006. UNDER THE
 2007 FBC WITH THE 2009 REVISIONS CHAPTER 35 STILL
 REFLECTS THE 2005. THE STATE HAS NOT ADOPTED THE 2008
 NEC. ( IT HAS NO BEEN TABLED TO AN UNKNOWN DATE)
  
 2) NOTE: PLEASE SEE CONFERENCE ROOM IN SECOND TENANT
 SPACE MEETING FBC 13-415.AB.1.1, .1.2 FOR CONTROLS.
  
 3) NOTE: PLEASE LIST THE REQUIRED NOTES FOR FBC
 13-413.AB.2
 ** THE NOTES AS LISTED DIRECTLY IN THE CODE BOOK IS THE
 INTENT TO HAVE ON PLANS.
  
 4) NOTE: PLEASE SEE THE 2009 REVISIONS TO THE 2007 FBC
 AS THE CODE SECTIONS AND LIGHTING PERFORMANCE
 CALCULATIONS HAVE BEEN UPDATED.
 THE SECTIONS ON PLANS ARE FROM THE PREVIOUS
 CODES/REVISIONS.
 KEEP IN MIND THE NEW SPACE BY SPACE DOES NOT ALLOW
 TRADE OFFS IN OTHER AREAS. 13-415.AB.5.
  
  
  
  
  
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-07-16 Cont ID  
Sent By mawillia Date 2009-07-16 Time 15:18 Rev Time 0.00
Received By mawillia Date 2009-07-16 Time 15:02 Sent To  
Notes
2009-07-16 15:13:27*****APPROVED*****
  
 PLAN SHEETS A-101, A-102, E-101, AND E-102 WERE
 STAMPED, INITIALED, AND DATED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-05-19 Cont ID  
Sent By mawillia Date 2009-05-19 Time 13:47 Rev Time 0.00
Received By mawillia Date 2009-05-19 Time 12:05 Sent To  
Notes
2009-05-19 13:13:47*****PROVISO*****
  
 PLAN SHEETS A-101 & 102 AND E-101 & E-102 TO BE
 FIRE-STAMPED WHEN THE FOLLOWING COMMENTS HAVE BEEN
 ADDRESSED:
  
 1. SHOW/DISPLAY THE LOCATION OF THE FIRE
 EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE.
  
 2. ADDRESS ELECTRICAL EXAMINER'S COMMENT SO THAT THE
 APPROPIATE ELECTRICAL SHEETS MAY BE FIRE-STAMPED.
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-06-12 Cont ID  
Sent By kstevens Date 2009-06-12 Time 11:59 Rev Time 0.00
Received By kstevens Date 2009-06-12 Time 11:59 Sent To  
Notes
2009-06-12 12:04:15SENT TO COMMERCIAL C37

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-05-19 Cont ID  
Sent By mawillia Date 2009-05-19 Time 13:48 Rev Time 0.00
Received By mawillia Date 2009-05-08 Time 09:32 Sent To  
Notes
2009-05-08 09:41:22B6

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-07-20 Cont ID  
Sent By rregueir Date 2009-07-20 Time 09:09 Rev Time 0.00
Received By rregueir Date 2009-07-20 Time 08:56 Sent To PC
Notes
2009-07-20 09:11:26**PROVISO**
 PROVIDE BALANCED RETURN IN ALL AREAS (SUCH AS RECEPTION
 AREAS) IN ACCORDANCE WITH FBC-M 601.4. RETURN JUMPERS
 NOT SIZED TO MEET EXCEPTION AS MARKED ON PLANS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-05-14 Cont ID  
Sent By rregueir Date 2009-05-14 Time 11:00 Rev Time 0.00
Received By rregueir Date 2009-05-14 Time 10:58 Sent To  
Notes
2009-05-14 11:00:55**PROVISO**
 PROVIDE BALANCED RETURN IN ALL AREAS (SUCH AS RECEPTION
 AREAS) IN ACCORDANCE WITH FBC-M 601.4. REVISE PLANS TO
 SHOW HOW BALANCED RETURN IS TO BE ACHIEVED PRIOR TO
 INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-07-02 Cont ID  
Sent By kstevens Date 2009-07-02 Time 16:26 Rev Time 0.00
Received By kstevens Date 2009-07-02 Time 16:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-05-12 Cont ID  
Sent By kstevens Date 2009-05-12 Time 10:32 Rev Time 0.00
Received By kstevens Date 2009-05-12 Time 10:32 Sent To  
Notes
***NONE***