Plan Review Details - Permit 09050093
| Plan Review Stops For Permit 09050093 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-05-15 |
Time |
11:30 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-05-15 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2009-05-15 11:23:26 | RED LINED: | | | 2007 CODE WITH 2009 SUPPLEMENTS | | | LEVEL II ALTERATION-404.1. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-06-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-06-24 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-06-24 |
Time |
13:01 |
Sent To |
PC |
|
| Notes |
| 2009-06-24 14:08:01 | | | | | | | | | | PROVISO | | | | | | DUE TO THE ADDITION OF SEVERAL RECEPTACLES THE | | | FOLLOWING IS REQUIRED. | | | | | | 1} CALCULATE THE NUMBER OF CIRCUITS NEEDED PER 220.14 | | | (I) AND CHANGE THE RISER NOTE ON SHEET A-1 TO INDICATE | | | THE CORRECT NUMBER OF CIRCUITS, NUMBER SAME AT THE | | | DEVICES.THIS ALSO APPLIES TO THE DEDICATED CIRCUITS | | | SHOWN. | | | RESUBMIT A REVISED SHEET PRIOR TO CALLING AN ELECTRICAL | | | FINAL INSPECTION. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-05-15 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-05-15 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-15 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-15 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2009-05-15 14:05:03 | *****APPROVED***** | | | | | | | | | PLAN SHEET A-3 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-06-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-06-17 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-17 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2009-06-17 07:57:00 | REV TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-15 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-06 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2009-05-06 11:41:07 | BOB BOARD #17 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-14 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-14 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
|