| Plan Review Stops For Permit 09050056 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-10-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-10-21 |
Time |
10:48 |
Rev Time |
0.45 |
| Received By |
jwitmer |
Date |
2009-10-21 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-08-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-18 |
Time |
10:52 |
Rev Time |
0.36 |
| Received By |
jwitmer |
Date |
2009-08-18 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2009-08-18 10:56:50 | BUILDING PLAN REVIEW | | | PERMIT: 09050056 | | | ADD: 205 N DIXIE HWY | | | CONT: M.A.C. CONSTRUCTION, INC | | | TEL: (786) 236-1006 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | AUGUST 18/2009 | | | | | | | | | NOTE: | | | CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A | | | LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE | | | FEE FOR PLAN REVIEW, IF PLANS ARE REJECTED THREE OR | | | MORE TIMES FOR REPEATED FAILURE TO CORRECT A CODE | | | VIOLATION. | | | SAME SHEETS SUBMITTED UNDER THE FIRST REVIEW< NO | | | CHANGES! | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 & 2007 FLORIDA EXISTING BUILDING | | | CODE WITH | | | 2009 SUPPLEMENTS. PLEASE PROVIDE LEVEL OF ALTERATION. | | | 2007 EXISTING BUILDING CODE 401.4 A DESIGN PROFESSIONAL | | | OR AN OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS | | | OF ALTERATION PURSUANT TO SECTIONS 403, 404 AND 405 OF | | | THIS CODE. PLEASE UPDATE YOUR CODE REFRENECES. | | | | | | 2) 10.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION THAT | | | IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | | DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 5, | | | TABLE 503, CHAPTER 6,& TABLE 601. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED | | | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | | | | 3) PLANS FAIL TO PROVIDE MANUFACTURERS INFORMATION FOR | | | FLOOR LOADING, TABLE 1607.1 COMPUTER ROOMS SHALL BE | | | DESIGNED FOR HEAVIER LOADS BASED ON THE ANTICIPATED | | | OCCUPANCY. | | | PLEASE PROVIDE FLOOR LOADING FOR THE RAISED FLOOR | | | LOADING AS WELL AS THE STRUCTURAL SLAB. | | | | | | 4) PLANS INDICATE THE USAGE OF THIS ROOM TO BE A IT | | | ROOM, NFPA 75 AND NEC 645.2 BOTH REQUIRE RATED WALLS. | | | PLANS DO NOT INDICATE ANY RATING OF THE WALLS OR | | | THROUGH PENETRATIONS. 712.3.1 THROUGH PENRTRATIONS. | | | | | | 5) SHEET A-1 INDICATES A PAIR OF NEW DOORS BUT NO | | | RATING INFORMATION, OPENING PROTECTIVES TABLE 715.3. | | | | | | NEW COMMENT: | | | 6) BRIDGE DESIGN CONSULTING ENGINEERS- ONE SET OF FLOOR | | | LOADING DOCUMENTS IS A COPY NOT ORIGINAL SIGNATUE NOR | | | SEALED. | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 FL. ADMIN. CODE. PLANS | | | SIGNED & SEALED BY A PROFESSIONAL ENGINEER SHALL | | | INCLUDE EITHER THE: NAME, ADDRESS AND LICENSE NUMBER OF | | | THE ENGINEER OR, THE NAME AND LICENSE NUMBER OF THE | | | ENGINEER AND THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING BUSINESS | | | THROUGH WHICH THE ENGINEER IS PRACTICING (471.025 F.S. | | | AND 471.023 F.S.). | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-05-14 |
Time |
13:21 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2009-05-14 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2009-05-14 14:18:05 | BUILDING PLAN REVIEW | | | PERMIT: 09050056 | | | ADD: 205 N DIXIE HWY | | | CONT: M.A.C. CONSTRUCTION, INC | | | TEL: (786) 236-1006 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 & 2007 FLORIDA EXISTING BUILDING | | | CODE WITH | | | 2009 SUPPLEMENTS. PLEASE PROVIDE LEVEL OF ALTERATION. | | | 2007 EXISTING BUILDING CODE 401.4 A DESIGN PROFESSIONAL | | | OR AN OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS | | | OF ALTERATION PURSUANT TO SECTIONS 403, 404 AND 405 OF | | | THIS CODE. PLEASE UPDATE YOUR CODE REFRENECES. | | | | | | 2) 10.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION THAT | | | IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS | | | DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 5, | | | TABLE 503, CHAPTER 6,& TABLE 601. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED | | | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | | | | 3) PLANS FAIL TO PROVIDE MANUFACTURERS INFORMATION FOR | | | FLOOR LOADING, TABLE 1607.1 COMPUTER ROOMS SHALL BE | | | DESIGNED FOR HEAVIER LOADS BASED ON THE ANTICIPATED | | | OCCUPANCY. | | | PLEASE PROVIDE FLOOR LOADING FOR THE RAISED FLOOR | | | LOADING AS WELL AS THE STRUCTURAL SLAB. | | | | | | 4) PLANS INDICATE THE USAGE OF THIS ROOM TO BE A IT | | | ROOM, NFPA 75 AND NEC 645.2 BOTH REQUIRE RATED WALLS. | | | PLANS DO NOT INDICATE ANY RATING OF THE WALLS OR | | | THROUGH PENETRATIONS. 712.3.1 THROUGH PENRTRATIONS. | | | | | | 5) SHEET A-1 INDICATES A PAIR OF NEW DOORS BUT NO | | | RATING INFORMATION, OPENING PROTECTIVES TABLE 715.3. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-10 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-10 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2009-10-10 13:36:20 | STAMPED PLANS, | | | | | | ALL LV, FS, FA ARE UNDER SEPARATE PERMITS. | | | NO LOW VOLTAGE INCLUDED IN ON THIS PERMIT. MUST HAVE | | | SEPARATE PERMIT HOWEVER MAY REFERENCE THESE PLANS FOR | | | LOW VOLTAGE SCOPE AS SHOWN. | | | FS AND FA REQUIRES SEPARATE PLANS SEE FIRE MARSHAL | | | REVIEW/STAMPS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-08-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-21 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-21 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2009-08-21 14:13:02 | ** DENIED 2ND REVIEW. | | | | | | 1) NOTE: SAME PLANS SUBMITTED BACK FOR REVIEW WITHOUT | | | ANY CHANGES. SEE FS 553.80(2)(B). | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-15 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-15 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2009-05-15 12:09:52 | **DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SEE FS 553.73 AS ALL PROJECTS SUBMITTED | | | FOR PERMIT AFTER MARCH 1ST, 2009 SHALL BE UNDER THE | | | FOLLOWING CODES. | | | PLEASE SEE FAC 69A-60.004 AS NFPA-101 AND NFPA-1 2006 | | | EDITIONS WERE REVISED AND ADOPTED AS OF DECEMBER 31, | | | 2009. | | | E101 INDICATES SOME OF THE OLDER CODES. | | | PLEASE BE SURE PLANS STATE THE FOLLOWING: | | | | | | 2007 FBC W/2009 REVISIONS. | | | 2006 NFPA-101 | | | | | | SOME OTHERS SUCH AS 2005 NFPA-70 ARE OK ALONG WITH 2003 | | | NFPA-75 AND 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE BUILDING REVIEW NOTES FOR RATINGS | | | FOR WALLS NEED TO BE INDICATED. IN ORDER TO USE THE | | | WIRING METHODS IN NEC 645, THE LOCATION SHALL MEET ALL | | | ITEMS LISTED IN NEC 645.4 (1-5). IF ALL ITEMS ARE NOT | | | PROVIDED THEN NO WIRING METHODS IN 645 ARE PERMITTED TO | | | BE USED. THEN ALL WIRING SHALL BE DONE PER CHAPTERS | | | 1-4. | | | PLEASE CONFIRM RATINGS. | | | | | | 3) NOTE: PLEASE SEE FBC 13-415.AB.1.1, .1.2 AN D.1.3 AS | | | ANY NEW LIGHTING CONTROLS SHALL MEET THE PRESCRIPTIVE | | | REQUIREMENTS FOR NEW BEING INSTALLED. | | | | | | 4) NOTE: PLEASE SEE FBC 13-415.AB.5, 13-415.B.5.1, | | | 13-415.B.1 FOR LIGHTING PERFORMANCE CALCULATIONS FOR | | | PRESCRIPTIVE SPACE REQUIREMENTS. | | | | | | 5) NOTE: PLEASE SHOW ALL LISTED WALL AND PENETRATION | | | DETAILS PER 300.21. | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-10-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-10-23 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-10-23 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2009-10-23 13:25:09 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED; PLAN SHEETS A-1, F/A-101, AND F-1 WERE | | | STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2009-08-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-08-21 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-08-21 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2009-08-21 10:54:30 | *****DENIED***** | | | | | | IT APPEARS THAT THE SAME SHEETS FROM THE PREVIOUS | | | REVIEW WERE SUBMITTED; THEREFORE THE FOLLOWING COMMENTS | | | NOT ADDRESSED: | | | | | | 1. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE | | | REFERENCED. ON SHEET E-101 IN SECTION F (CODES & | | | STANDARDS), AMEND NFPA 101 TO REFLECT THE CURRENT | | | EDITION. | | | | | | 2. ON SHEET F/A-101, EXPLAIN VERBAGE " USE THOSE THAN | | | APPLY" IN THE FIRE ALARM SYSTEM LEGEND. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-05-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-20 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-20 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2009-05-20 15:14:00 | *****DENIED***** | | | | | | 1. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE | | | REFERENCED. ON SHEET E-101 IN SECTION F (CODES & | | | STANDARDS), AMEND NFPA 101 TO REFLECT THE CURRENT | | | EDITION. | | | | | | 2. ON SHEET F/A-101, EXPLAIN VERBAGE " USE THOSE THAN | | | APPLY" IN THE FIRE ALARM SYSTEM LEGEND. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2010-01-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2010-01-11 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2010-01-11 |
Time |
14:54 |
Sent To |
P |
|
| Notes |
| 2010-01-11 14:55:14 | PLUMB REV TO P IN BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-11-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-11-10 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-11-10 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2009-11-10 11:28:24 | TO KS DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-09-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-09-30 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-09-30 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2009-09-30 09:44:53 | SENT TO COMMERCIAL BOX #38. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-08-10 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-08-10 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-10 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
F |
Date |
2009-05-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-20 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-05 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2009-05-05 17:09:55 | TO C26 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-10-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-10-23 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-10-23 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2009-10-23 12:59:51 | **PROVISO** | | | | | | 1. PROVIDE CONDENSER MANUFACTURER'S WIND RESISTANCE | | | DATA TO THE DEPARTMENT FOR PLAN REVIEW IN ACCORDANCE | | | WITH FBC-M 301.12. | | | | | | 2. PROVIDE FULL PRODUCT APPROVAL DOCUMENTATION TO FIELD | | | INSPECTOR AT TIME OF INSPECTION PER FBC-B 106.3.3 AND | | | FAC RULE 9B-72. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-08-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-14 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-14 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2009-08-14 15:19:22 | SAME SHEETS SUBMITTED FROM PREVIOUS REVIEW. COMMENTS | | | NOT ADDRESSED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-15 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-15 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2009-05-15 14:23:32 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PAGE M-4 SHOWS AN ALUMINUM STAND TO BE USED ON ROOF | | | FOR NEW CONDENSING UNIT. PROVIDE ENGINEERING AND | | | STRUCTURAL DETAIL FOR FIELD FABRICATED STAND SHOWING | | | WIND RESISTANCE CAPABILITIES AND MEANS OF ATTACHMENT TO | | | STRUCTURE IN ACCORDANCE WITH FBC-M 301.12. IF A | | | PRE-ENGINEERED A/C STAND IS USED, PROVIDE PRODUCT | | | APPROVAL WITH INSTALLATION INSTRUCTIONS PER FAC RULE | | | 9B-72. | | | | | | 2. PROVIDE APPLIANCE MANUFACTURER'S DATA SHOWING THE | | | CONDENSING UNIT IS DESIGNED FOR WIND RESISTANCE IN | | | ACCORDANCE WITH FBC-M 301.12. | | | | | | 3. AIR HANDLER SHALL BE PROVIDED WITH AUXILIARY DRAIN | | | PROTECTION IN ACCORDANCE WITH FBC-M 307.2.3. | | | | | | 4. AHU MOUNTED SMOKE DETECTOR SHALL BE CONNECTED TO THE | | | BUILDING FIRE ALARM SYSTEM IN ACCORDANCE WITH FBC-M | | | 606.4.1. | | | | | | 5. ALL NEW PIPING WHICH PENETRATES A RATED FLOOR OR | | | WALL ASSEMBLY SHALL BE PROTECTED AS A | | | THROUGH-PENETRATION IN ACCORANCE WITH FBC-B 712.3.3. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-11-16 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-11-16 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2009-09-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-30 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-30 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2009-09-30 16:38:41 | DENIED | | | REFERENCE: | | | FBC-2007 W/2009 SUPPLEMENTS | | | FBC-2007 PLUMBING | | | FBC-2007 CHAPTER 1 | | | MUNICIPAL CODE CITY WPB | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | ******FROM PREVIOUS REVIEWS: | | | | | | 1. SHT P-1 SHOWS EXISTING FIRE PROTECTION DRAIN | | | DRAINING INTO THE CONDENSATE SYSTEM. PER SECTION 301.3 | | | DISCHARGE OF LIQUID WASTE OR SEWAGE SHALL CONNECT TO | | | THE SANITARY DRAINAGE SYSTEM. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | ******RESPONSE NOTED, BUT THE RESPONSE THAT THE FLOOR | | | DRAIN IS CONNECTED TO THE SANITARY SYSTEM IS NOT WHAT | | | IS SHOWN ON THE PLANS. THE PLAN SHOW ALL THE AHU & A/C | | | UNITS DRAINING INTO THE EXISTING 2 INCH CONDENSATE | | | LINE. CONDENSATE SHALL NOT DRAIN INTO THE SANITARY PER | | | THE WEST PALM BEACH CITY CODE ARTICLE III SECTION | | | 90-125(5). PLEASE CLARIFY. IS THIS A CONDENSATE SYSTEM | | | AS INDICATED OR A SANITARY SYSTEM IN WHICH CASE THE | | | CONDENSATE SHALL NOT DRAIN INTO PER CITY CODE. | | | | | | 2. SHT P-1 INDICATES NEW COLD WATER PIPING TO NEW AC | | | UNIT CRU-3. BACKFLOW PROTECTION IS REQUIRED. SECTION | | | 608. PLEASE INDICATE METHOD. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | ******RESPONSE NOTED. THE BACKFLOW SHALL BE INSTALLED A | | | MAXIMUM 4 FEET ABOVE THE FLOOR FOR TESTING AND | | | CERTIFICATION AND SHALL HAVE DRAIN LINE AND AN AIR GAP | | | TO AN APPROVED INDIRECT WASTE RECEPTOR. MANUF | | | INSTALLATION INSTRUCTIONS.SECTION 301.2. | | | | | | 3. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2009-08-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-14 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-14 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2009-08-14 15:47:04 | DENIED | | | REFERENCE: | | | FBC-2007 W/2009 SUPPLEMENTS | | | FBC-2007 PLUMBING | | | MUNICIPAL CODE CITY WPB | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. SHT P-1 SHOWS EXISTING FIRE PROTECTION DRAIN | | | DRAINING INTO THE CONDENSATE SYSTEM. PER SECTION 301.3 | | | DISCHARGE OF LIQUID WASTE OR SEWAGE SHALL CONNECT TO | | | THE SANITARY DRAINAGE SYSTEM. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | | | 2. SHT P-1 INDICATES NEW COLD WATER PIPING TO NEW AC | | | UNIT CRU-3. BACKFLOW PROTECTION IS REQUIRED. SECTION | | | 608. PLEASE INDICATE METHOD. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | | | 3. PLANS SHALL BE DESIGNED PER THE CURRENT CODE CYCLE | | | WHICH IS FBC-2007 W/2009 SUPPLEMENTS. PLEASE INDICATE | | | ON PLANS. SECTION 106.1.1. | | | ****NO RESPONSE, COMMENT NOT ADDRESSED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-05-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-11 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-11 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2009-05-11 16:20:00 | DENIED | | | REFERENCE: | | | FBC-2007 W/2009 SUPPLEMENTS | | | FBC-2007 PLUMBING | | | MUNICIPAL CODE CITY WPB | | | | | | 1. SHT P-1 SHOWS EXISTING FIRE PROTECTION DRAIN | | | DRAINING INTO THE CONDENSATE SYSTEM. PER SECTION 301.3 | | | DISCHARGE OF LIQUID WASTE OR SEWAGE SHALL CONNECT TO | | | THE SANITARY DRAINAGE SYSTEM. | | | | | | 2. SHT P-1 INDICATES NEW COLD WATER PIPING TO NEW AC | | | UNIT CRU-3. BACKFLOW PROTECTION IS REQUIRED. SECTION | | | 608. PLEASE INDICATE METHOD. | | | | | | 3. PLANS SHALL BE DESIGNED PER THE CURRENT CODE CYCLE | | | WHICH IS FBC-2007 W/2009 SUPPLEMENTS. PLEASE INDICATE | | | ON PLANS. SECTION 106.1.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|