| Plan Review Stops For Permit 09050005 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-07-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-24 |
Time |
10:45 |
Rev Time |
1.25 |
| Received By |
jwitmer |
Date |
2009-07-24 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2009-07-24 10:27:18 | BUILDING PROVISOS: | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) R703.3 WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL | | | SIDING. | | | | | | R703.3.1 PANEL SIDING. JOINTS IN WOOD, HARDBOARD OR | | | WOOD STRUCTURAL PANEL SIDING SHALL BE MADE AS FOLLOWS | | | UNLESS OTHERWISE APPROVED. HORIZONTAL JOINTS IN PANEL | | | SIDING SHALL BE LAPPED A MINIMUM OF 1 INCH (25 MM) OR | | | SHALL BE SHIPLAPPED OR SHALL BE FLASHED WITH Z-FLASHING | | | AND OCCUR OVER SOLID BLOCKING, WOOD OR WOOD STRUCTURAL | | | PANEL SHEATHING. | | | | | | 3) R 806 ROOF VENTILATION | | | R806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING | | | AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE | | | SPACE VENTILATED EXCEPT THAT REDUCTION OF THE TOTAL | | | AREA TO 1/300 IS PERMITTED, PROVIDED THAT AT LEAST 50 | | | PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED | | | VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN | | | THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT | | | LEAST 3 FEET (914 MM) ABOVE THE EAVE OR CORNICE VENTS | | | WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED | | | BY EAVE OR CORNICE VENTS | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-05-18 |
Time |
11:15 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
2009-05-18 |
Time |
8:00 |
Sent To |
|
|
| Notes |
| 2009-05-18 12:01:27 | BUILDING PLAN REVIEW | | | PERMIT: 09050005 | | | ADD: 308 COLONIAL RD | | | CONT: UNDERHILL BLDG & ROOFING | | | TEL: (561)379-3665 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009, 2007 FLORIDA EXISTING BUILDING CODE | | | WITH 2009 SUPPLEMENTS, CHAPTER 10 ADDITIONS, PLEASE | | | UPDATE PLANS, A2 & S2. | | | | | | 2) FEES, STATE RADON FEES OF $4.62 ARE OWED. | | | | | | 3) SHEET A-2 TYPICAL WALL SECTION IS MISSLABELED, | | | INDICATES A TYPICAL GARAGE WALL SECTION, PLEASE CORRECT | | | WITH TRAY CEILING AS INDICATED IN THE MASTER BEDROOM. | | | PLANS ARE LACKING DETAILS FOR EAVE VENTING AND 1/2 HALF | | | OF THE REQUIRED ROOF VENTING TO BE A MINIMUM OF 3'-0" | | | ABOVE THE EAVE VENTS. R806.2. | | | | | | 4) SHEET A-2 TYPICAL WALL SECTION, PLANS DO NOT | | | INDICATE TTHE TYPICAL GABLE END WALL DETAILS. PLANS DO | | | NOT INDICATE THE REQUIRED BRACING FOR THE GABLE END | | | WALL TRUSS. | | | BUILDING PROVISO; R502.1.3.2 BRACING. TRUSSES SHALL BE | | | BRACED TO PREVENT ROTATION AND PROVIDE LATERAL | | | STABILITY IN ACCORDANCE WITH THE REQUIREMENTS SPECIFIED | | | IN THE CONSTRUCTION DOCUMENTS FOR THE BUILDING AND ON | | | THE INDIVIDUAL TRUSS DESIGN DRAWINGS. IN THE ABSENCE OF | | | SPECIFIC BRACING REQUIREMENTS, TRUSSES SHALL BE BRACED | | | IN ACCORDANCE WITH TPI/WTCA BCSI. | | | | | | 5) THE GABLE END WALL DOES NOT PROVIDE HOW THE | | | HORIZONTAL JOINT IN THE T-111 SHEATHING WILL OCCUR, | | | PLEASE PROVIDE COMPLIANCE WITH: R703.3.1 PANEL SIDING. | | | JOINTS IN WOOD, HARDBOARD OR WOOD STRUCTURAL PANEL | | | SIDING SHALL BE MADE AS FOLLOWS UNLESS OTHERWISE | | | APPROVED. HORIZONTAL JOINTS IN PANEL SIDING SHALL BE | | | LAPPED A MINIMUM OF 1 INCH (25 MM) OR SHALL BE | | | SHIPLAPPED OR SHALL BE FLASHED WITH Z-FLASHING AND | | | OCCUR OVER SOLID BLOCKING, WOOD OR WOOD STRUCTURAL | | | PANEL SHEATHING. | | | | | | 6) THE MEP SHEETS DO NOT INDICATE SMOKE DETECTORS IN | | | THE NEW MASTER BEDROOM, PLEASE PROVIDE COMPLIANCE WITH: | | | R313.1 SMOKE DETECTION AND NOTIFICATION. ALL SMOKE | | | ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 217 AND | | | INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS | | | CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT | | | PROVISIONS OF NFPA 72. | | | | | | HOUSEHOLD FIRE ALARM SYSTEMS INSTALLED IN ACCORDANCE | | | WITH NFPA 72 THAT INCLUDE SMOKE ALARMS, OR A | | | COMBINATION OF SMOKE DETECTOR AND AUDIBLE NOTIFICATION | | | DEVICE INSTALLED AS REQUIRED BY THIS SECTION FOR SMOKE | | | ALARMS, SHALL BE PERMITTED. THE HOUSEHOLD FIRE ALARM | | | SYSTEM SHALL PROVIDE THE SAME LEVEL OF SMOKE DETECTION | | | AND ALARM AS REQUIRED BY THIS SECTION FOR SMOKE ALARMS | | | IN THE EVENT THE FIRE ALARM PANEL IS REMOVED OR THE | | | SYSTEM IS NOT CONNECTED TO A CENTRAL STATION. | | | | | | R313.2 LOCATION. SMOKE ALARMS SHALL BE INSTALLED IN THE | | | FOLLOWING LOCATIONS: | | | | | | 1. IN EACH SLEEPING ROOM. | | | | | | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. | | | | | | 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-28 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-27 |
Time |
16:59 |
Sent To |
P |
|
| Notes |
| 2009-08-28 08:47:52 | NEEDS RE-STAMPS FOR MECH AND PLUMBING AS SHEETS WERE | | | CHANGED OUT AND THESE ARE ON THE SAME NEW SHEETS WITH | | | ELECTRICAL. | | 2009-08-28 08:46:44 | | | | ** PROVISO/REDLINED PLANS** | | | | | | *** THE FOLLOWING ARE SET FORTH AS A PROVISO. MAKE | | | ADJUSTMENTS BEFORE INSPECTIONS | | | | | | 1) NOTE: THE CONDENSING UNIT LOAD OVER CURRENT | | | PROTECTION/BREAKER ON LOAD CALCULATIONS IS SHOWN AT | | | 2-25AMP HOWEVER PANEL SCHEDULE FOR THE SAME CU IS SHOWN | | | AS 30AMP. | | | THE AHU ON THE LOAD CALCULATIONS INDICATES A 30AMP | | | BREAKER WHICH IS THE MINIMUM REQUIRED PER 424.3B. | | | HOWEVER THE PANEL SCHEDULE FOR THE NEW AHU INDICATES A | | | 2-25AMP BREAKER. THESE SEEM TO HAVE BEEN REVERSED. | | | LOADS ARE TO BE SHOWN PER 220.83B. NO DE-RATING IS | | | PERMITTING WHEN ADDING TO AN EXISTING SERVICE. | | | | | | 2) NOTE: THE RISER STILL INDICATES AN *EQUIPMENT | | | GROUNDING CONDUCTOR* AHEAD OF 150AMP MAIN. THIS IS TO | | | BE VIF AS IT SHOULD NOT BE INSTALLED. THIS CREATES | | | OBJECTIONABLE CURRENTS PER 250.6, 250.24. | | | THE RISER IS MISSING AN *EQUIPMENT GROUNDING CONDUCTOR | | | FROM NEW 100AMP MAIN TO SUB PANEL *B*. AS REQUIRED PER | | | 250.24,250.110,250.122. | | | | | | 3) NOTE: PLEASE SEE 422.13 AS THE WATER HEATER LOAD | | | NEEDS TO BE SHOWN AT 125%. ( SEE HANDBOOK AS THIS IS A | | | CONTINUOUS LOAD FOR FEEDERS AND SERVICES UNDER THE 2005 | | | NEC. | | | | | | **** IMPORTANT: | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-31 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-31 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2009-07-31 15:45:43 | ** DENIED 2ND REVIEW ** | | | | | | *** SOME COMMENTS FROM PREVIOUS REVIEW ARE STILL IN | | | NEED OF ADDRESSING ALONG WITH SOME NEW NOTES BASED ON | | | REVISED INFORMATION NOW SHOWN ON PLANS. | | | ** IT IS RECOMMENDED A MEETING BE SET UP TO GO OVER | | | COMMENTS. | | | | | | 1) NOTE: PLANS NOW MENTIONS CARBON MONOXIDE DETECTORS | | | INSIDE ALL NEW AND EXISTING SLEEPING ROOMS. PREVIOUS | | | REVIEW DID NOT COMMENT ON THIS. THE COMMENT HAD TO DO | | | WITH SMOKE ALARMS PER R313.1 AND NFPA-72. PLEASE SEE FS | | | 553.885 FOR LOCATION OF REQUIRED CARBON MONOXIDE | | | DETECTOR WHICH IS ACTUALLY WITHIN 10FT LOCATED OUTSIDE | | | THE SLEEPING ROOM. | | | | | | 2) NOTE: PLEASE SEE THE LOAD CALCULATIONS, PANEL | | | SCHEDULES, BREAKERS AND CONDUCTORS FOR A/C EQUIPMENT IS | | | STILL NOT COORDINATING. LOAD CALCULATIONS FOR EXAMPLE | | | INDICATE 50AMP BREAKERS WITH #8 AWG CONDUCTORS FOR | | | CONDENSING UNITS, YET THE ONE NEW CU ON PANEL SCHEDULE | | | INDICATES #12 AWG WITH A 2-POLE 20AMP BREAKER. PLEASE | | | LOOK UP THE MANUFACTURES RECOMMENDED OCP AND CIRCUIT | | | SIZE. | | | PLEASE SEE ANOTHER CONFLICT WITH MINIMUM AND MAXIMUM | | | OVER CURRENT PROTECTION, AND CONDUCTORS IS WITH THE TWO | | | HEAT STRIPS INDICATED ON THE LOAD | | | CALCULATIONS/SCHEDULE. | | | BOTH THE 7.5 KW AND 4KW HEAT ON LOAD/SCHEDULE STATES #6 | | | AWG AND 60AMP BREAKER. THIS IS NOT POSSIBLE FOR EITHER | | | ONE. THE PANEL SCHEDULE FOR THE NEW AHU STATES 40AMP | | | WITH #8 AWG WHICH DOES NOT COORDINATE. IN EITHER CASE | | | PLEASE SEE 424.3B AND 422.11E3. THE TYPICAL MINIMUM | | | OVER CURRENT PROTECTION SIZING IS 125% AND THE MAXIMUM | | | IS 150%. | | | ** PLEASE ALSO VERIFY THE FACT ONE UNIT IS INDICATING A | | | 4KW HEAT STRIP, THIS IS NOT KNOWN TO BE TYPICAL. | | | ***** PLEASE ALSO SEE 422.12,220.60 ETC | | | A/C LOADS FOR LOAD CALCULATIONS MAY BE DE-RATED HOWEVER | | | WHEN FIGURING THE LARGER OF THE TWO LOADS, YOU USE THE | | | ACTUAL LOAD BEFORE DE-RATING NOT THE LOAD AFTER | | | DE-RATING. | | | ** PLEASE ALSO CHECK THE KW LOADS SHOWN FOR THE | | | CONDENSING UNITS, THESE SEEM TO BE HIGH. | | | | | | | | | 3) NOTE: THE PREVIOUS REVIEW MADE NOTE TO 210.52D FOR | | | THE LOCATION OF THE GFI RECEPTACLE IN THE BATHROOM. AN | | | OCCUPANT IS NOT PERMITTED TO CROSS OVER ONE SINK TO | | | PLUG IN AN APPLIANCE ON THE OTHER SIDE OF ANOTHER SINK. | | | THE OPTION IS TO RELOCATE THE ONE GFI TO THE MIDDLE OF | | | THE TWO SINKS OR TO ADD AND ADDITIONAL GFI RECEPTACLE. | | | NO RELOCATION WAS DONE AND NO DEVICE WAS ADDED. | | | | | | 4) NOTE: PREVIOUS REVIEW MENTIONED THAT THE RISER DID | | | NOT INDICATE ANY EQUIPMENT GROUNDING CONDUCTORS AFTER | | | THE FIRST MEANS OF DISCONNECT. NO CONDUCTORS PER | | | 250.122, 250.110,250.24 ETC WERE ADDED. | | | THIS IS ONLY AFTER THE FIRST MEANS OF DISCONNECT. | | | | | | 5) NOTE: PREVIOUS REVIEW MENTIONED 210.12 FOR ARC FAULT | | | PROTECTION REQUIRED FOR ALL CIRCUITS/OUTLETS IN | | | BEDROOMS. THIS WAS REVISED IN THE 2002 NEC. THE PANEL | | | SCHEDULE ONLY INDICATES AFCI PROTECTION ON ONE OF THE | | | TWO MASTER BEDROOM CIRCUITS. | | | | | | 6) NOTE: PREVIOUS REVIEW MENTIONED TO IDENTIFY THE | | | 3-WAY SWITCH LOCATED ON THE REAR WALL OF THE NEW MASTER | | | BEDROOM. THE 3-WAY SWITCH ON PLANS DOES NOT GO TO | | | ANYTHING?? | | | 220,210,300,310 ETC, | | | FBC 106.1.1 | | | SECTIONS GIVEN IN GENERAL AS IT IS NOT CLEAR WHAT THIS | | | IS FOR. | | | | | | 7) NOTE: PLEASE SEE PREVIOUS REVIEW WHICH REQUESTED FOR | | | ALL SERVICE EQUIPMENT LOCATIONS TO BE IDENTIFIED ON | | | PLANS. THE PLANS WERE REVISED TO SHOW THE NEW METER AND | | | ONE NEW MAIN DISCONNECT HOWEVER THE SECOND DISCONNECT | | | IS NOT SHOWN. PLEASE SEE 230.72 AS THIS REQUIRES ALL | | | MAINS TO BE GROUPED. | | | ALSO 110.26 FOR MINIMUM CLEARANCES. | | | | | | 8) NOTE: PLEASE SEE PREVIOUS NOTE WITH RESPECT TO NEW | | | OR EXISTING SMOKE ALARMS IN DWELLING BEING BROUGHT UP | | | TO THE CURRENT NFPA-72 11.8.3 REQUIREMENTS. THE PLANS | | | CONTAINS A NOTE HOWEVER AT SOME POINT A BASIC LAYOUT | | | FOR THE EXISTING DWELLING SHOWING THE LOCATIONS WILL BE | | | NEEDED. THIS CAN BE PART OF A PROVISO AT A LATER DATE | | | IF LOCATIONS ARE NOT KNOWN AT THIS TIME. | | | | | | ** PER NEW BUILDING OFFICIAL, PLANS ARE NO LONGER | | | RELEASE HOWEVER PER THE IMPACT REVIEW STOP, ONE SET | | | WILL BE REQUIRED TO BE SIGNED OUT FOR REVIEW AND | | | STAMPING BY PAL BEACH COUNTY. | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-15 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-15 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2009-05-15 15:29:58 | **DENIED REVIEW ** | | | | | | 1) NOTE: PLANS SHALL STATE MINIMUM CODE UNDER PERMIT | | | APPLICATION MADE. | | | ALL PLANS AFTER MARCH 1ST, 2009 SHALL CONTAIN THE | | | FOLLOWING AT A MINIMUM FOR THIS SCOPE. | | | 2007 FBC W/ 2009 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE R313 FOR REQUIRED SMOKE ALARMS. | | | THIS REQUIRES NEW/EXISTING TO MEET CURRENT CODE | | | REQUIREMENTS. PLEASE ALSO SEE NFPA-72 11.5.1 AND | | | 11.8.3. | | | THIS REQUIRES NEW SMOKE ALARM DEVICES INSIDE AND OUT | | | NEW SLEEPING ROOM. SECTION 118.3 REQUIRED UNIT TO BE | | | WITHIN 3FT OF THE HIGHEST POINT ON A SLOPED CEILING. | | | ** KEEP IN MIND UNDER THE REVISED CODE IN 2002 AND 2005 | | | ALL OUTLETS IN BEDROOM REQUIRE AFCI PROTECTION | | | INCLUDING SMOKE ALARM DEVICES. | | | | | | 3) NOTE: PLANS NEED TO SHOW LOCATION OF NEW SERVICE | | | MAINS AND DISCONNECTS. | | | 240.24, 110.26. | | | BASED ON THE PLANS THE EXISTING PANEL DOES NOT MEET | | | 110.26 AND POWER WILL NOT BE RELEASED BACK TO DWELLING | | | UNLESS RE-LOCATED. | | | | | | 4) NOTE: PLEASE SEE 210.52D FOR BATH COUNTER GFI | | | RECEPTACLE. THE GFI AS SHOWN NEEDS TO BE RELOCATED OR A | | | NEW ONE ADDED. THIS IS TO PREVENT THE OCCUPANT FROM | | | CROSSING OVER THE SINK AREA TO PLUG IN ANY APPLIANCE. | | | THIS IS A SAFETY ISSUE. | | | | | | 5) NOTE: PLEASE SEE THE RISER DOES NOT INDICATE ANY | | | EQUIPMENT GROUNDING CONDUCTOR AFTER THE FIRST MEANS OF | | | DISCONNECT FROM THE NEW MAIN TO THE EXISTING PANEL *A*. | | | 250.122,250.110,250.24. | | | | | | 6) NOTE: PLEASE SEE RISER AS IT DOES INDICATE THE AIC | | | RATING FOR THE OTHER NEW MAIN FEEDING EXISTING PANEL. | | | 110.9 | | | | | | 7) NOTE: *** PLEASE VERIFY WITH THE SERVICE PROVIDER | | | THAT THEY ARE ACTUALLY GOING TO BE INSTALLING THE | | | CONDUCTORS UNDERGROUND FROM THE POLE TO THE NEW | | | SERVICE. THE RISER SHOWS TWO RUNS OF CONDUITS. MOST | | | LIKELY FPL WILL NOT BE RUNNING PARALLEL SERVICE | | | ENTRANCE CONDUCTORS. PLEASE ALSO VERIFY THEY WILL NOT | | | BE INSTALLING A NEW HAND HOLE AT THE BASE OF POLE | | | REQUIRING OWNER TO RUN FROM THAT LOCATION TO THE | | | DWELLING. THIS IS BEING DONE IN MANY LOCATIONS FOR NEW | | | SERVICES IN WHICH FPL IS NOT INSTALLING CONDUCTORS UP | | | TO THE DWELLING. IF THIS IS THE CASE THE CONDUITS AND | | | CONDUCTORS WOULD FALL UNDER NEC AND 310.16, 310.15B6 AT | | | A MINIMUM. | | | | | | 8) NOTE: PLEASE SEE CLOSET AREA WHICH INDICATES A NEW | | | 220V RECEPTACLE PER THE SYMBOL LEGEND. BASED ON THE | | | PLANS THIS APPEARS THIS IS BEING SHOWN FOR THE AHU. | | | PLEASE SEE 440.11, 440.12, 422.31, 424.19AS A | | | RECEPTACLE FOR CORD AND PLUG CONNECTION MAY NOT BE USED | | | OR INSTALLED. | | | THIS REQUIRES A DISCONNECT. | | | | | | 9) NOTE: PLEASE SEE LOAD CALCULATIONS WHICH ARE NOT | | | CLEAR ON ACTUAL KW OF AHU/ HEAT. SEE 10KW LOAD NOTED AT | | | 100% WHICH IS SHOWN IN THE CALCULATIONS AS 7.5KW? | | | PLEASE SEE 220.83 AND 424.3B | | | | | | 10) NOTE: PLEASE LIST THE REQUIRED ARC FAULT PROTECTED | | | CIRCUITS ON THE PANEL SCHEDULE FOR NEW BEDROOM | | | CIRCUITS. 210.12 | | | | | | 11) NOTE: PLEASE SEE 408.4 WHICH WAS REVISED IN THE | | | 2005 NEC WHICH REQUIRES THE PANEL SCHEDULE TO BE | | | SPECIFIC TO THE ROOMS AND AREAS IN WHICH THEY FEED. | | | PLEASE SEE THE USE OF * GENERAL LTS, OR GENERAL | | | RECEPTACLES* IS NOT PERMITTED. THESE WOULD BE NOTED AS | | | * MASTER BEDRM LTS PR MASTER BEDRM RECEPTS* OR WORDS TO | | | THAT AFFECT. | | | | | | 12) NOTE: PLEASE SEE 220.52 AS THE LAUNDRY/WASHER LOADS | | | ARE REQUIRED TO BE FIGURED AT 1500VA MINIMUM. PLANS | | | INDICATE 800VA. | | | | | | 13) NOTE: PLEASE IDENTIFY THE THREE-WAY SWITCH AT THE | | | MASTER BEDROOM BACK DOOR WHICH IS NOT SHOWN GOING TO | | | ANYTHING. | | | NEC 2005, FBC 106.1.1 FOR CLARITY. | | | | | | | | | | | | * IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-07-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-07-15 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-07-15 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-05-18 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-05-01 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2009-05-18 11:13:19 | BUILDING PLAN REVIEW | | | PERMIT: 09050005 | | | ADD: 308 COLONIEL RD | | | CONT: UNDERHILL BLDG & ROOFING | | | TEL: (561)379-3665 | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009, 2007 FLORIDA EXISTING BUILDING CODE | | | WITH 2009 SUPPLEMENTS, CHAPTER 10 ADDITIONS. PLEASE | | | UPDATE PLANS. | | | | | | 2) SHEET A-2 INDICATES THE WIND DESIGN BUT NOT THE | | | REFRENECE STANDARD USED? SEE DESIGN CRITERIA R301.2.1.1 | | | | | | 3) SHEET A-2 DOES NOT INDICATE ROOF VENTING EAVE NOT | | | THE REQUIRED 50% A MINIMUM OF 3'-0" ABOVE THE EAVE | | | VENTS. R806.2 | | | | | | 4) PLANS DO NOT PROVIDE A TRUE SECTION THROUGH THE WALL | | | SECTION, WALL SECTION INDICATES IT TO BE A TYPICAL | | | GARAGE WALL WHEREAS THIS IS A BEDROOM WITH TRAY | | | CEILING. THE SECOND ISSUE IS THERE IS NO SECTION | | | INDICATING A SECTION THROUGH THE GABLE END WALL, HOW | | | THIS WALL WILL BE FRAMED? BRACING FOR THE GABLE END | | | WALL, NOR HOW THE HORIZONTAL END JOINTS OF THE T-111 | | | SIDING WILL BE TREATED. R 703..3.1. | | | | | | 5) BUILDING PROVISO: PROVIDE TRUSS BRACING FOR GABLE | | | END WALL. R502.1.3.2 BRACING. TRUSSES SHALL BE BRACED | | | TO PREVENT ROTATION AND PROVIDE LATERAL STABILITY IN | | | ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN THE | | | CONSTRUCTION DOCUMENTS FOR THE BUILDING AND ON THE | | | INDIVIDUAL TRUSS DESIGN DRAWINGS. IN THE ABSENCE OF | | | SPECIFIC BRACING REQUIREMENTS, TRUSSES SHALL BE BRACED | | | IN ACCORDANCE WITH TPI/WTCA BCSI. | | | | | | 6) MEP-1 SMOKE ALRMS DUE NOT APPEAR IN THIS SHEET, | | | R313.2 LOCATION. SMOKE ALARMS SHALL BE INSTALLED IN THE | | | FOLLOWING LOCATIONS: | | | | | | 1. IN EACH SLEEPING ROOM. | | | | | | 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. | | | | | | 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING | | | BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND | | | UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS | | | WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR | | | BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON | | | THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER | | | LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE | | | FULL STORY BELOW THE UPPER LEVEL. | | | | | | WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE | | | INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM | | | DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT | | | THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE | | | ALARMS IN THE INDIVIDUAL UNIT. | | | | | | R313.2.1 ALTERATIONS, REPAIRS AND ADDITIONS. WHEN | | | ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT | | | OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR | | | CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL DWELLING | | | UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS | | | REQUIRED FOR NEW DWELLINGS; THE SMOKE ALARMS SHALL BE | | | INTERCONNECTED AND HARD WIRED. | | | | | | EXCEPTIONS: | | | | | | 1. INTERCONNECTION AND HARD-WIRING OF SMOKE ALARMS IN | | | EXISTING AREAS SHALL NOT BE REQUIRED WHERE THE | | | ALTERATIONS OR REPAIRS DO NOT RESULT IN THE REMOVAL OF | | | INTERIOR WALL OR CEILING FINISHES EXPOSING THE | | | STRUCTURE, UNLESS THERE IS AN ATTIC, CRAWL SPACE OR | | | BASEMENT AVAILABLE WHICH COULD PROVIDE ACCESS FOR HARD | | | WIRING AND INTERCONNECTION WITHOUT THE REMOVAL OF | | | INTERIOR FINISHES. | | | | | | 2. WORK INVOLVING THE EXTERIOR SURFACES OF DWELLINGS, | | | SUCH AS THE REPLACEMENT OF ROOFING OR SIDING, OR THE | | | ADDITION OR REPLACEMENT OF WINDOWS OR DOORS, OR THE | | | ADDITION OF A PORCH OR DECK, ARE EXEMPT FROM THE | | | REQUIREMENTS OF THIS SECTION. | | | | | | R313.3 POWER SOURCE. IN NEW CONSTRUCTION, THE REQUIRED | | | SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE | | | BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A | | | COMMERCIAL SOURCE, AND WHEN PRIMARY POWER IS | | | INTERRUPTED, SHALL RECEIVE POWER FROM A BATTERY. WIRING | | | SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH | | | OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. | | | SMOKE ALARMS SHALL BE PERMITTED TO BE BATTERY OPERATED | | | WHEN INSTALLED IN BUILDINGS WITHOUT COMMERCIAL POWER OR | | | IN BUILDINGS THAT UNDERGO ALTERATIONS, REPAIRS OR | | | ADDITIONS REGULATED BY SECTION R313.2.1. | | | | | | 7) | | 2009-05-01 15:27:51 | R5 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2009-10-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-10-21 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-10-21 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2009-10-21 09:28:24 | PR# 09 017230 AMOUNT: $1,093.12 /VERIFIED FEES WERE | | | PAID TO P B COUNTY, JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2009-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-28 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-28 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2009-08-28 08:23:50 | CALLED AND SPOKE TO CONRACTOR HE WILL TAKE TO PBC FOR | | | IMPACT FEE REVIEW ONCE ALL REVIEWS ARE COMPLETED. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2009-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-31 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-10-21 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2009-07-31 15:07:23 | HAS NOT GONE TO PBC FOR IMPACT FEE REVIEW/STAMPS. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-07-24 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-07-24 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-07-24 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2009-07-24 17:13:18 | ***LANDSCAPE PASSED WITH 'PROVISO'*** | | | | | | 1. LANDSCAPE PLAN WITH LANDSCAPE CALULATIONS SHALL BE | | | SUBMITTED AND APPROVED PRIOR TO C/O. | | | | | | 2. SUBMIT A COST ESTIMATE WITH THE LANDSCAPE PLAN THAT | | | INCLUDES THE TOTAL COST OF ALL LANDSCAPE MATERIALS AND | | | LABOR, BROKEN DOWN INTO UNIT COST. | | | | | | 3. AN IRRIGATION PERMIT IS REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-05-14 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-05-14 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2009-05-14 15:26:17 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | | FORMAT. | | | | | | 1. PURSUANT TO SECTION 94-441 (B), THE LANDSCAPING, | | | TREE PROTECTION AND SCREENING REQUIREMENTS OF THIS | | | SECTION SHALL APPLY TO ALL DEVELOPMENT WITHIN THE CITY, | | | PROVIDED THAT THE RENOVATIONS, REPAIR, ALTERATION OR | | | REDEVELOPMENT EXCEEDS 50 PERCENT OF THE VALUE OF THE | | | STRUCTURE. THE ENTIRE SITE SHALL BE BROUGHT UP TO | | | CURRENT LANDSCAPE STANDARDS. | | | | | | 2. PURSUANT TO SECTION 94-448 (D)(2), SUBMIT A | | | LANDSCAPE PLAN THAT CONTAINS ALL OF THE REQUIRED | | | INFORMATION LISTED IN THIS SECTION. | | | | | | 3. SUBMIT A COMPLETE LANDSCAPE COST ESTIMATE BROKEN | | | DOWN INTO UNIT COST THAT INCLUDES THE TOTAL COST OF ALL | | | LANDSCAPE MATERIALS AND LABOR. | | | | | | 4. AN IRRIGATION PERMIT IS REQUIRED. ALL LANDSCAPE | | | AREAS SHALL BE PROVIDED WITH 120% IRRIGATION COVERAGE, | | | INCLUDING THE RIGHTS-OF-WAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-09-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-08 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-08 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2009-09-08 10:24:03 | RE-STAMPED REPLACED PAGES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-07-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-28 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-28 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-05-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-11 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2009-05-11 15:10:42 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENT | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PLEASE REFERENCE THE CURRENT CODE IN EFFECT AT TIME | | | OF PERMIT APPLICATION. THE 2007 FLORIDA BUILDING CODE | | | WITH 2009 SUPPLEMENT IS IN EFFECT AS OF MARCH 1, 2009. | | | | | | 2. ENERGY CALCULATIONS: FORM 600C-04 WAS SUBMITTED FOR | | | ENERGY CODE COMPLIANCE. THIS FORM IS NO LONGER | | | APPLICABLE AS OF MARCH 1, 2009. ADDITIONS TO EXISTING | | | RESIDENTIAL BUILDINGS SHALL BE CONSIDERED NEW BUILDING | | | CONSTRUCTION AND SHALL COMPLY WITH THE REQUIREMENTS OF | | | EITHER METHOD A OR B AS APPLICABLE IN ACCORDANCE WITH | | | FBC-R SECTION N1100.0.3. PLEASE SUBMIT FORM 100A-08 OR | | | FORM 1100B-08 TO DEMONSTRATE ENERGY CODE COMPLIANCE. | | | | | | 3. A COOLING AND HEATING LOAD CALCULATION SHALL BE | | | PERFORMED ON THE BUILDING AND SHALL BE ATTACHED TO THE | | | FORM 1100 SUBMITTED WHEN APPLICATION IS MADE FOR A | | | BUILDING PERMIT IN ACCORDANCE WITH FBC-R SECTION | | | N1107.AB.1. | | | | | | 4. PLEASE PROVIDE ALL FLEXIBLE AND RECTANGULAR DUCT | | | SIZES ON PLANS. DUCT SYSTEMS SERVING HEATING, COOLING | | | AND VENTILATION EQUIPMENT SHALL BE FABRICATED IN | | | ACCORDANCE WITH THE PROVISIONS OF ACCA MANUAL D OR | | | OTHER APPROVED METHODS PER FBC-R SECTION M1601.1. | | | | | | 5. PAGE MEP-1 SHOWS NEW BATH EXHAUST TERMINATING AT THE | | | SOFFIT. THE AIR REMOVED BY THE MECHANICAL EXHAUST | | | SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS AND SHALL | | | NOT BE EXHAUSTED INTO A SOFFIT IN ACCORDANCE WITH FBC-R | | | SECTION M1501.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-09-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-09-01 |
Time |
08:25 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2009-09-01 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-04 |
Time |
14:35 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2009-08-04 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-05-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-08 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-08 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2009-05-08 10:39:18 | DENIED | | | REFERENCE: | | | FBC-2007 W/2009 SUPPLEMENTS | | | FBC-2007 PLUMBING | | | FBC-2007 CHAPTER 1 | | | | | | 1. SHTS A-2 & MEP-1 CODES REFERENCED ARE FBC-2004 | | | W/2006 REVISIONS & THE STANDARD PLUMBING CODE. FOR ALL | | | APPLICATIONS FOR PERMIT SUBMITTED ON OR AFTER MARCH 1, | | | 2009, PLANS SHALL BE DESIGNED AND REFERENCED TO THE | | | FBC-2007 WITH 2009 SUPPLEMENTS. PLEASE DESIGN PLANS AND | | | CHANGE CODE REFERENCES TO THE CORRECT CODE CYCLE. | | | SECTION 106.1.1. | | | | | | 2. SHT MEP-1 SANITARY RISER DIAGRAM. FITTINGS SHALL BE | | | INSTALLED TO GUIDE SEWAGE & WASTE IN THE DIRECTION OF | | | FLOW. SECTION 706.3. THE TUB CONNECTION TO THE BRANCH | | | LINE AT THE LAVS IS INCORRECT. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-07-23 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-07-23 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-07-23 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2009-07-23 14:25:10 | PASSED W/PROVISO: | | | THE LANDSCAPE/IRRIGATION PLANS SHALL BE APPROVED PRIOR | | | TO FINAL C.O. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | PLACED BACK ON R1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-05-15 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-05-15 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2009-05-15 11:49:33 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK | | | EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS | | | "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR, | | | SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | 4. INDICATE OVERHANG DIMENSIONS OF THE PROPOSED | | | ADDITION. PURSUANT TO THE ZLDR, SECTION 94-305(B): | | | OVERHANGS SHALL NOT PROJECT MORE THAN THREE (3) FEET | | | INTO A REQUIRED SETBACK. | | | | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | PLACED BACK ON RES RACK R5 |
|
|