Plan Review Details - Permit 09040557
Plan Review Stops For Permit 09040557
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-06-12 Cont ID  
Sent By jwitmer Date 2009-06-12 Time 09:0 Rev Time 0.55
Received By jwitmer Date 2009-06-12 Time 08:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-05-08 Cont ID  
Sent By jwitmer Date 2009-05-08 Time 16:51 Rev Time 2.22
Received By jwitmer Date 2009-05-08 Time 16:30 Sent To  
Notes
2009-05-08 16:55:15BUILDING PLAN REVIEW
 PERMIT: 09040557
 ADD: 8036 CRANES POINTE WAY
 CONT: SHELDON FRIEFELD, INC.
 TEL: (561)722-5078
  
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009, 2007 EXISTING BUILDING CODE WITH
 2009 SUPPLEMENTS, CHAPTER 10 FOR ADDITIONS.
  
 2) PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G16.003 ARCHITECTS
  
 3) MISSING DESIGN PERIMETERS: 110.2* W. P. B.
 ADMINISTRATIVE CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE
 PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6,
 TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
  
 4) R301.1.2.1.1 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
  
 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
  
 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
  
 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION
 OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL, FRONT ELEVATION AND ROOF ZONES.
  
 5) SHEET A3 DETAIL# 1 IS MISSING INFORMATION ON THE
 FOUNDATION, SIZE OF REBAR, PSI OF CONCRETE, DENSITY OF
 SOILS, MINIMUM BEARING VALUE OF SOILS, VAPOR BARRIER
 AND TERMITE TREATMENT INFORMATION. R401.4, R401.4.1,
 R402.2, R405.2.2, R2304.11.6.
  
 6) PRODUCT APPROVALS FOR CAST CRETE LINTELS WAS
 SUBMITTED FOR REVIEW BUT THERE IS NO INDICATION AS TO
 INSTALATION, OVER THE WINDOWS OR GARAGE DOOR, SIZE OF
 LINTAL DEPTH OF LINTAL.
 THE GARAGE OVERHEAD DOOR ALSO IS MISSING INFORMATION IF
 THIS IS TO BE A LINTAL, ACOMBINATION LINTEL AND BOND
 BEAM OR A BEAM WITH REBAR AND STIRRUPS. THE PLANS DO
 NOT INDICATE CHIPPING BACK INTO THE EXISTING CORNER TO
 BEAR THE NEW BEAM OR LINTAL ONTO THE EXISTING COLUMN.
  
 7) PLANS FAIL TO PROVIDE A TRUSS PLAN WITH THE
 MAGNITUDE OF LOADS TO BE RESISTED, GRAVITY, LATERAL &
 UPLIFT, R802.2.9 ROOF TIE-DOWN.
  
 8) SHEET 3 DETAIL # 1 FAILS TO PROVIDE ROOF SHEATHING
 NAILING PATERNS SEE R802.2.3.1.
  
 9) SHEET# 3 DETAIL# 1 FAILS TO PROVIDE CODE COMPLIANCE
 WITH: REQUIRED VENTILATING AREA IS PROVIDED BY
 VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE
 TO BE VENTILATED AT LEAST 3 FEET (914 MM) ABOVE THE
 EAVE OR CORNICE VENTS
  
 10) R807.1 ATTIC ACCESS. BUILDINGS WITH COMBUSTIBLE
 CEILING OR ROOF CONSTRUCTION SHALL HAVE AN ATTIC ACCESS
 OPENING TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8
 M2) AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR
 MORE.
  
 11) ENTEGRA ROOF TILE: PLEASE PROVIDE INFORMATION ON
 WHICH SYSTEM IS TO BE USED TO SECURE THE ROOF TILE,
 CIRCLE SYSTEM. R905.3 CLAY AND CONCRETE TILE. THE
 INSTALLATION OF CLAY AND CONCRETE SHALL BE IN
 ACCORDANCE WITH RECOMMENDATIONS OF FRSA/TRI
 07320.R905.3.7.1 HIP AND RIDGE TILES. HIP AND RIDGE
 TILES SHALL BE INSTALLED IN ACCORDANCE WITH FRSA/TRI
 07320.
  
 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-06-10 Cont ID  
Sent By dpalmer Date 2009-06-10 Time 16:51 Rev Time 0.00
Received By dpalmer Date 2009-06-10 Time 16:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-05-18 Cont ID  
Sent By dpalmer Date 2009-05-15 Time 08:49 Rev Time 0.00
Received By dpalmer Date 2009-05-15 Time 08:49 Sent To  
Notes
2009-05-18 08:49:37**DENIED REVIEW **
  
 1) NOTE: PLANS SUBMITTED CONTAIN A RUBBER STAMP IN LIEU
 OF THE REQUIRED ORIGINAL SIGNATURE. THIS IS NOT
 PERMITTED PER FS 481.221. THIS ARCHITECT HAS BEEN
 NOTIFIED BY THIS OFFICE ON MORE THAN ONE OCCASION ON
 PREVIOUS PROJECTS OF THIS VIOLATION OF FLORIDA
 STATUTES. ONE SET WILL BE RETAINED BY THIS OFFICE.
 PLANS MAY BE FORWARDED TO THE BOARD OF ARCHITECTS. THIS
 HAS BEEN CONFIRMED WITH THE BOARD OF ARCHITECTS
 ATTORNEY AND INVESTIGATOR.
  
 2) NOTE: PLEASE SEE 250.50 AS THE NEW FOOTER STEEL
 SHALL BE BONDED PART OF THE GROUNDING ELECTRODE SYSTEM.
  
 3) NOTE: PLEASE SUBMIT ELECTRICAL FOR NEW. PLEASE SEE
 210.52G AND 210.8A2 AS A NEW GFI RECEPTACLE IS
 REQUIRED.
  
 4) NOTE: PLEASE INDICATE THE REQUIRED DEDICATED CIRCUIT
 FOR THE GARAGE DOOR OPENER. 240.4, 310.16, 430. 248.
 408.4
  
 5) NOTE: PLEASE CLARIFY THE SCOPE OF WORK ON PLANS.
 THERE ARE ITEMS SUCH AS CONDENSING UNITS, OUTSIDE GFI
 ETC WHICH ARE SHOWN HOWEVER NOT SHOWN AS EXISTING. IF
 ITEMS ARE NOT INDICATED AS EXISTING THEN THEY ARE
 LOOKED AT AS BEING NEW. PLEASE KNOW THIS WOULD AFFECT
 THE REVIEW AND OR COMMENTS.
  
 6) NOTE: PLANS SHALL STATE MINIMUM CODE UNDER PERMIT
 APPLICATION MADE.
 ALL PLANS AFTER MARCH 1ST, 2009 SHALL CONTAIN THE
 FOLLOWING AT A MINIMUM FOR THIS SCOPE.
 2007 FBC W/ 2009 REVISIONS
 2005 NFPA-70
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-06-12 Cont ID  
Sent By jwitmer Date 2009-06-12 Time 08:47 Rev Time 0.00
Received By jwitmer Date 2009-06-03 Time 15:49 Sent To  
Notes
2009-06-04 15:53:35TO R22

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-02 Cont ID  
Sent By rbrown Date 2009-05-19 Time 21:01 Rev Time 0.00
Received By rbrown Date 2009-04-29 Time 14:13 Sent To  
Notes
2009-04-29 14:13:41TO R16

Review Stop Z ZONING
Rev No 2 Status P Date 2009-06-09 Cont ID  
Sent By mcruz Date 2009-06-09 Time 17:37 Rev Time 0.00
Received By mcruz Date 2009-06-09 Time 17:34 Sent To  
Notes
2009-06-09 17:37:58PLACED BACK IN R22

Review Stop Z ZONING
Rev No 1 Status F Date 2009-05-22 Cont ID  
Sent By mcruz Date 2009-05-19 Time 15:54 Rev Time 0.00
Received By mcruz Date 2009-05-19 Time 15:53 Sent To  
Notes
2009-05-19 15:55:13PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PER FLORIDA STATE STATUTE, ARCHITECT SIGNATURE SHALL
 NOT BE STAMPED.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
  
 PLACED BACK ON R16