| Plan Review Stops For Permit 09040549 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-05-07 |
Time |
14:27 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2009-05-07 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-06-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-06-04 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-06-04 |
Time |
10:50 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-05-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-05-08 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-05-08 |
Time |
10:24 |
Sent To |
I |
|
| Notes |
| 2009-05-08 10:24:30 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} 210.11(C)(1) SMALL-APPLIANCE BRANCH CIRCUITS IN | | | ADDITION TO THE NUMBER OF BRANCH CIRCUITS REQUIRED BY | | | OTHER PARTS OF THIS SECTION, TWO OR MORE 20-AMPERE | | | SMALL-APPLIANCE BRANCH CIRCUITS SHALL BE PROVIDED FOR | | | ALL RECEPTACLE OUTLETS SPECIFIED BY 210.52(B). ***ONLY | | | ONE SMALL APPLIANCE CIRCUIT IS SHOWN ON THE PANEL | | | SCHEDULE | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2009-05-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-05 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-05 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2009-05-05 10:35:36 | *****APPROVED***** | | | | | | SINGLE PLAN SHEET A1 WAS STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-05 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-05 |
Time |
07:44 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-05-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-05-13 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-05-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-05-08 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-04-29 |
Time |
12:28 |
Sent To |
PC |
|
| Notes |
| 2009-04-29 12:32:19 | TO B-12 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-06-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-04 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-04 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2009-04-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-30 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-30 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2009-04-30 10:08:57 | REVIEW #: 1ST | | | ACTION: PASSED W/ PROVISO | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | **PROVISO** | | | COOKING APPLIANCES INSTALLED WITHIN DWELLING UNITS AND | | | WITHIN AREAS WHERE DOMESTIC COOKING OPERATIONS OCCUR | | | SHALL BE LISTED AND LABELED AS HOUSEHOLD-TYPE | | | APPLIANCES FOR DOMESTIC USE IN ACCORDANCE WITH FBC-M | | | 917.3. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2009-05-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-13 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-13 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2009-05-13 13:51:54 | NEW KITCHEN SINK IN SAME LOCATION -- MOVE ICE LINE TO | | | NEW REF. LOCATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-05-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-05 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-05 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2009-05-05 13:41:19 | DENIED | | | REFERENCE: | | | FBC-2007 W/2009 SUPPLEMENTS | | | FBC-2007 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT A1 INDICATES THAT PLANS WERE DESIGNED TO THE | | | FBC-2004 CODE CYCLE. ALL PERMITS APPLIED FOR ON OR | | | AFTER MARCH 1, 2009 FALL UNDER THE FBC-2007 CODE CYCLE. | | | PLEASE DESIGN THE PLANS AND INDICATE ON THE PLANS THE | | | CORRECT CODE CYCLE. SECTION 106.1.1. | | | | | | 2. THE STATE OF FLORIDA DEPT OF BUSINESS REGULATION, | | | (DBPR), WEBSITE INDICATES THE ARCHITECT'S STATUS AS | | | DELINQUENT. (SEE ATTACHED SHEET) - PLEASE UPDATE STATUS | | | TO ACTIVE PRIOR TO RESUBMITTING FOR REVIEW WITH THE | | | CITY WPB. FAC 61G1-15.001 & FS 481.2055. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|