Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-05-26 Cont ID  
Sent By shill Date 2009-05-26 Time 13:45 Rev Time 0.00
Received By shill Date 2009-05-26 Time 13:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-05-18 Cont ID  
Sent By shill Date 2009-05-18 Time 09:19 Rev Time 0.00
Received By shill Date 2009-05-18 Time 09:19 Sent To  
Notes
2009-05-18 09:29:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. THE SPAN FOR ALL OPENINGS IS THE SAME AS OPENING
 SIZE. HOW IS THIS POSSIBLE WITH A 3" EDGE DISTANCE AND
 C2 (WALL MOUNT) CONNECTION? AT A MINIMUM, SPAN SHOULD
 BE AT LEAST 3" LARGER THAN THE OPENING. THIS COMMENT
 AFFECTS ANCHORING FOR OPENING 2; WHEN 3" IS ADDED TO
 103", THE COLUMN FOR "SPANS UP TO 8'8"" CAN NO LONGER
 BE USED (8'8" = 104"). PLEASE CLARIFY SPANS.
  
 2. OPENINGS OVER 104" MUST USE THE COLUMN FOR "SPANS UP
 TO 13'", SEE PAGE 11 OF PRODUCT APPROVAL. OPENING 2 IS
 IN QUESTION (MUST FIRST DETERMINE CORRECT SPAN).
 OPENING 1 REQUIRES 5" ON BOTTOM, NOT 8".
  
 PLEASE CHECK ALL OPENINGS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-05-06 Cont ID  
Sent By shill Date 2009-05-06 Time 15:52 Rev Time 0.00
Received By shill Date 2009-05-06 Time 15:52 Sent To  
Notes
2009-05-06 15:54:59****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM CAN BE OBTAINED IN THE LOBBY OR ON THE
 INTERNET AT:
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2ND REVIEW, ANCHOR SPACING COLUMN IS BLANK.
  
 2. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE FOR
 EXPOSURE B, FBC R301, FBC1609.
  
 2ND REVIEW, CALCULATIONS ARE FOR EXPOSURE B. PLEASE
 REVISE TO EXPOSURE C OR HAVE THE ENGINEER CONTACT ME TO
 EXPLAIN RATIONALE/JUSTIFICATION FOR EXPOSORE C.
  
 3. CALCULATIONS ARE IN ACCORDANCE WITH ASCE7-02,
 INCORRECT REFERENCE, FBC43.
  
 2ND REVIEW, NOT ADDRESSED. PLEASE NOTE THAT
 CALCULATIONS AR NOT REQUIRED, CAN USE PRESSURES IN FBC
 R CODE, BUT IF SUBMITTED MUST COMPLY WITH CODE
 REQUIREMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-15 Cont ID  
Sent By shill Date 2009-04-15 Time 17:51 Rev Time 0.00
Received By shill Date 2009-04-14 Time 15:36 Sent To  
Notes
2009-04-15 17:54:21****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM CAN BE OBTAINED IN THE LOBBY OR ON THE
 INTERNET AT:
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE FOR
 EXPOSURE B, FBC R301, FBC1609.
  
 3. CALCULATIONS ARE IN ACCORDANCE WITH ASCE7-02,
 INCORRECT REFERENCE, FBC43.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-05-26 Cont ID  
Sent By btrobaug Date 2009-05-26 Time 10:15 Rev Time 0.00
Received By btrobaug Date 2009-05-26 Time 10:12 Sent To B
Notes
2009-05-26 10:15:07TO SAMANTHA'S DESK./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-05-26 Cont ID  
Sent By shill Date 2009-05-18 Time 09:30 Rev Time 0.00
Received By shill Date 2009-05-13 Time 08:38 Sent To  
Notes
2009-05-13 08:39:07INCOMING TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-04-30 Cont ID  
Sent By rregueir Date 2009-04-30 Time 16:47 Rev Time 0.00
Received By rregueir Date 2009-04-30 Time 16:47 Sent To  
Notes
2009-04-30 16:47:46TO SHILL DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-15 Cont ID  
Sent By shill Date 2009-04-15 Time 17:54 Rev Time 0.00
Received By shill Date   Time   Sent To  
Notes
***NONE***