Plan Review Details - Permit 09040294
| Plan Review Stops For Permit 09040294 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-01 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-01 |
Time |
17:07 |
Sent To |
PC |
|
| Notes |
| 2009-05-01 17:09:30 | TALKED TO HOWARD. HE SAID HE'LL APPLY FOR THE CLEAR | | | SHUTTERS PERMIT WHEN HE GETS THE PRODUCT APPROVAL | | | APPROVED BY THE STATE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-04-14 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-04-14 |
Time |
09:33 |
Sent To |
PC |
|
| Notes |
| 2009-04-14 09:47:00 | RESIDENTIAL (R3) SHUTTERS, BUILDING REVIEW CHECKLIST. | | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2008 | | | REVISIONS. | | | | | | 1- A) PROVIDE COMPLETE INSTALLATION SCHEDULE FOR STORM | | | SHUTTERS AS REQUIRED BY CITY IMPLEMENTATION STANDARD | | | FOR WIND-BORNE DEBRIS IMPACT PROTECTION. SEE ATTACHED | | | SAMPLE. | | | | | | B) CLEARLY MARK ON PRODUCT APPROVAL SPECIFIC MOUNTING | | | CONDITIONS (EG: WALL MOUNTED, BUILT OUT, CEILING | | | MOUNTED, ETC) AND SPECIFIC ANCHOR TO BE USED ACCORDING | | | TO THE DESIGN PRESSURES, EDGE DISTANCE, CONNECTION | | | TYPE, PANEL SPAN SUBSTRATE TO BE ATTACHED TO (EG: | | | CONCRETE, CONCRETE BLOCK, WOOD, ETC). | | | ***NOTE: TAKE INTO CONSIDERATION THAT CONCRETE | | | SUBSTRATE REQUIRES SPECIFIC CONCRETE STRENGTH. USE | | | CONCRETE BLOCK TABLES FOR ANCHOR SPACING WHEN CONCRETE | | | BLOCK FILLED CELLS IS THE SUBSTRATE TO RECEIVE THE | | | PANELS. OTHERWISE PROVIDE PROOF OF REQUIRED CONCRETE | | | STRENGTH. | | | | | | 2- FLORIDA PRODUCT APPROVAL FL5389 FOR STORM PANELS | | | SUBMITTED IS FOR 2004 CODE VERSION. NEED TO SUBMIT | | | PRODUCT APPROVAL FOR 2007 CODE VERSION WHICH IS THE | | | CURRENT CODE IN EFFECT. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-04-14 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-04-14 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy