| 2009-04-27 13:49:17 | BUILDING PLAN REVIEW |
| | PERMIT: 09040206 |
| | ADD: 8397 NICHOLLS POINT/ ANDOS ISLES |
| | CONT: NATIONWIDE POOLS |
| | TEL: (954)227-7665 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE/ RESIDENTIAL W/ |
| | 2009 FBC SUPPLEMENTS |
| | |
| | ****BUILDING PROVISO****: |
| | |
| | POOL PLAN INDICATES ???POOL ENCLOSURE,??? FENCE BY |
| | OWNERS, WILL REQUIRE A SEPARATE PERMIT. |
| | |
| | R4101.19 FINAL INSPECTION. FINAL ELECTRICAL, AND |
| | BARRIER CODE, INSPECTION SHALL BE COMPLETED PRIOR TO |
| | FILLING THE POOL WITH WATER. |
| | |
| | R4101.17.1.15A MESH SAFETY BARRIER MEETING THE |
| | REQUIREMENTS OF SECTION R4101.17 AND THE FOLLOWING |
| | MINIMUM REQUIREMENTS SHALL BE CONSIDERED A BARRIER AS |
| | DEFINED IN THIS SECTION: |
| | |
| | 1.INDIVIDUAL COMPONENT VERTICAL SUPPORT POSTS SHALL BE |
| | CAPABLE OF RESISTING A MINIMUM OF 52 POUNDS (229 N) OF |
| | HORIZONTAL FORCE PRIOR TO BREAKAGE WHEN MEASURED AT A |
| | 36-INCH (914 MM) HEIGHT ABOVE GRADE. VERTICAL POSTS OF |
| | THE CHILD MESH SAFETY BARRIER SHALL EXTEND A MINIMUM OF |
| | 3 INCHES (76 MM) BELOW DECK LEVEL AND SHALL BE SPACED |
| | NO GREATER THAN 36 INCHES (914 MM) APART. |
| | |
| | PLEASE INDICATE HOW THE VERTICAL POST WILL BE SUPPORTED |
| | WHERE IT APPEARS THAT THE POST WILL BE PLACED IN A |
| | GRASSED IN AREA. THE SECTION ABOVE INDICATES THE POST |
| | ARE TO BE PLACED A MINIMUM OF 3 INCHES (76 MM) BELOW |
| | DECK LEVEL AND WITHIN A SLEEVE. PLEASE INDICATE HOW |
| | COMPLIANCE WITH THE 52 POUND HORIZONTAL FORCE WILL BE |
| | MET. |
| | |