Plan Review Details - Permit 09040174
| Plan Review Stops For Permit 09040174 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-04 |
Time |
07:50 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2009-08-04 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2009-08-04 07:44:33 | BUILDING PLAN REVIEW | | | PERMIT: 09040174 | | | ADD: 1590 FLORIDA MANGO | | | CONT: SOUTH EAST CERTIFIED CONTRACTORS | | | TEL: (561)635-6935 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | AUGUST 4 /09 | | | BUILDING PROVISO | | | SHOP DRAWING TO BE REVIEWED BY DESIGN PROFESSIONAL | | | BEFORE THE SUBMITTAL TO CITY FOR REVIEW BEFORE | | | INSPECTION. | | | NFPA 110: 8.4 OPERATIONAL INSPECTION AND TESTING. | | | 8.4.1* EPSSS, INCLUDING ALL APPURTENANT COMPONENTS, | | | SHALL BE INSPECTED WEEKLY AND EXERCISED UNDER LOAD AT | | | LEAST MONTHLY. | | | | | | 1) STAIRS 1009.3 EXCEPTION# 7. INDUSTRIAL EQUIPMENT | | | ACCESS STAIRS AND LANDINGS THAT SERVE AS A COMPONENT OF | | | THE MEANS OF EGRESS FROM THE INVOLVED EQUIPMENT AND DO | | | NOT SERVE MORE THAN 20 PEOPLE SHALL BE PERMITTED TO | | | HAVE A MINIMUM CLEAR WIDTH OF 22 INCHES (559 MM), | | | MINIMUM TREAD DEPTH OF 10 INCHES (254 MM), MAXIMUM | | | RISER HEIGHT OF 9 INCHES (229 MM), MINIMUM | | | HEADROOM OF 6 FEET 8 INCHES (2032 MM), AND A MAXIMUM | | | HEIGHT BETWEEN LANDINGS OF 12 FEET (36 576 MM). | | | | | | 2) GAURDRAILS: 1012.1 WHERE REQUIRED. | | | GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING | | | SURFACES, INDUSTRIAL EQUIPMENT PLATFORMS, LANDINGS | | | WHICH ARE LOCATED MORE THAN 30 INCHES (762 MM) ABOVE | | | THE FLOOR OR GRADE BELOW. | | | GUARDS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN | | | ACCORDANCE WITH SECTION 1607.7. | | | | | | 3) GUARD 1012.3 OPENING LIMITATIONS. EXCEPTIONS: | | | 2.AT ELEVATED WALKING SURFACES FOR ACCESS TO AND USE OF | | | ELECTRICAL, MECHANICAL OR PLUMBING SYSTEMS OR | | | EQUIPMENT, GUARDS SHALL HAVE BALUSTERS OR BE OF SOLID | | | MATERIALS SUCH THAT A | | | SPHERE WITH A DIAMETER OF 21 INCHES (533 MM) CANNOT | | | PASS THROUGH ANY OPENING. | | | 3.IN AREAS WHICH ARE NOT OPEN TO THE PUBLIC WITHIN | | | OCCUPANCIES IN GROUP I-3, F, H OR S, BALUSTERS, | | | HORIZONTAL INTERMEDIATE RAILS OR OTHER CONSTRUCTION | | | SHALL NOT PERMIT A SPHERE WITH A | | | DIAMETER OF 21 INCHES (533 MM) TO PASS THROUGH ANY | | | OPENING. | | | | | | 4) BEFORE A CERTIFICATE OF COMPLETION CAN BE ISSUED | | | PLEASE PROVIDE EVIDENCE THAT THE TOP OF THE GENERATOR | | | SLAB IS AT OR ABOVE ELEVATION 13.5' NGVD, FLOOD ZONE | | | A-9 | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-07-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-27 |
Time |
17:30 |
Rev Time |
1.10 |
| Received By |
jwitmer |
Date |
2009-07-27 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2009-07-27 17:39:37 | BUILDING PLAN REVIEW | | | PERMIT: 09040174 | | | ADD: 1590 FLORIDA MANGO | | | CONT: SOUTH EAST CERTIFIED CONTRACTORS | | | TEL: (561)635-6935 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | JULY 27/09 | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1-2) COMPLIED | | | | | | 3) THE PLAN DOES NOT NDICATE IF THIS IS A NEW SLAB OR | | | REUSE OF AN EXISTING SLAB. 2702.1. | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL BE INSTALLED | | | IN ACCORDANCE WITH THE NFPA 70, NATIONAL ELECTRICAL | | | CODE, NFPA 110 AND NFPA 111. | | | NFPA 110: | | | 3A) 7.4 MOUNTING. | | | | | | 7.4.1 ROTATING ENERGY CONVERTERS SHALL BE INSTALLED ON | | | SOLID FOUNDATIONS TO PROHIBIT SAGGING OF FUEL, EXHAUST, | | | OR LUBRICATING-OIL PIPING AND DAMAGE TO PARTS RESULTING | | | IN LEAKAGE AT JOINTS. | | | | | | 7.4.1.1 SUCH FOUNDATIONS OR STRUCTURAL BASES SHALL | | | RAISE THE ENGINE AT LEAST 150 MM (6 IN.) ABOVE THE | | | FLOOR OR GRADE LEVEL AND BE OF SUFFICIENT ELEVATION TO | | | FACILITATE LUBRICATING-OIL DRAINAGE AND | | | EASE OF MAINTENANCE. | | | | | | 7.4.2 FOUNDATIONS SHALL BE OF THE SIZE (MASS) AND TYPE | | | RECOMMENDED BY THE ENERGY CONVERTER MANUFACTURER. | | | | | | 7.4.3 WHERE REQUIRED TO PREVENT TRANSMISSION OF | | | VIBRATION DURING OPERATION, THE FOUNDATION SHALL BE | | | ISOLATED FROM THE SURROUNDING FLOOR OR OTHER | | | FOUNDATIONS, OR BOTH, IN ACCORDANCE WITH THE | | | MANUFACTURER'S RECOMMENDATIONS AND ACCEPTED STRUCTURAL | | | ENGINEERING PRACTICES. | | | | | | 7.4.4 THE EPS SHALL BE MOUNTED ON A FABRICATED METAL | | | SKID BASE OF THE TYPE THAT SHALL RESIST DAMAGE DURING | | | SHIPPING AND HANDLING. AFTER INSTALLATION, THE BASE | | | SHALL MAINTAIN ALIGNMENT OF THE | | | UNIT DURING OPERATION. PLANS DO NOT PROVIDE INFORMATION | | | FOR SECONDARY CONTAINMENT. NFPA 110: 7.9.12 LISTED | | | GENERATOR SUBBASE SECONDARY CONTAINMENT FUEL TANKS OF | | | 2498 L (660 GAL) | | | CAPACITY AND BELOW SHALL BE PERMITTED TO BE INSTALLED | | | OUTDOORS OR INDOORS WITHOUT DIKING OR REMOTE | | | IMPOUNDING.PLANS DO NOT INDICATE THE GALLON CAPACITY. | | | | | | 4) PLANS FAIL TO PROVIDE INFORMATION FOR THE FOUNDATION | | | AND SLAB FOR GENERATOR A TANK, PLEASE PROVIDE DETAILS | | | FOR ANCHORING OF TANK AND GENERATOR AGAINST OVERTURNING | | | ,UPLIFT AND SLIPPAGE FBC BUILDING 1609.1.3 | | | | | | 5) COMMENT NUMBER 5 DEALS WWITH THE REASON A STAIR AND | | | ACCESS PLATFORM IS REQUIRED. FOR MAINTENANCE AND WEEKLY | | | VISUAL INSPECTION OF GENERATOR A ELEVATED PLATFORM, | | | STAIR AND GUARDRAIL SYSTEM WILL BE REQUIRED. NFPA 110: | | | 8.4 OPERATIONAL INSPECTION AND TESTING. 8.4.1* EPSSS, | | | INCLUDING ALL APPURTENANT COMPONENTS, SHALL BE | | | INSPECTED WEEKLY AND EXERCISED UNDER LOAD AT LEAST | | | MONTHLY. DEPENDING ON TTHE HEIGHT OF THE FUEL TANK. | | | | | | 6)PLEASE PROVIDE CODE COMPLIANCE. STAIRS 1009.3 | | | EXCEPTION# 7. INDUSTRIAL EQUIPMENT ACCESS STAIRS AND | | | LANDINGS THAT SERVE AS A COMPONENT OF THE MEANS OF | | | EGRESS FROM THE INVOLVED EQUIPMENT AND DO NOT SERVE | | | MORE THAN 20 PEOPLE SHALL BE PERMITTED TO HAVE A | | | MINIMUM CLEAR WIDTH OF 22 INCHES (559 MM), MINIMUM | | | TREAD DEPTH OF 10 INCHES (254 MM), MAXIMUM RISER HEIGHT | | | OF 9 INCHES (229 MM), MINIMUM HEADROOM OF 6 FEET 8 | | | INCHES (2032 MM), AND A MAXIMUM HEIGHT BETWEEN LANDINGS | | | OF 12 FEET (36 576 MM). | | | | | | 7) PLEASE PROVIDE CODE COMPLIANCE. GAURDRAILS: 1012.1 | | | WHERE REQUIRED. | | | GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING | | | SURFACES, INDUSTRIAL EQUIPMENT PLATFORMS, LANDINGS | | | WHICH ARE LOCATED MORE THAN 30 INCHES (762 MM) ABOVE | | | THE FLOOR OR GRADE BELOW. | | | GUARDS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN | | | ACCORDANCE WITH SECTION 1607.7. | | | | | | 8)PLEASE GUARD 1012.3 OPENING LIMITATIONS. EXCEPTIONS: | | | 2. AT ELEVATED WALKING SURFACES FOR ACCESS TO AND USE | | | OF ELECTRICAL, MECHANICAL OR PLUMBING SYSTEMS OR | | | EQUIPMENT, GUARDS SHALL HAVE BALUSTERS OR BE OF SOLID | | | MATERIALS SUCH THAT A | | | SPHERE WITH A DIAMETER OF 21 INCHES (533 MM) CANNOT | | | PASS THROUGH ANY OPENING. | | | 3. IN AREAS WHICH ARE NOT OPEN TO THE PUBLIC WITHIN | | | OCCUPANCIES IN GROUP I-3, F, H OR S, BALUSTERS, | | | HORIZONTAL INTERMEDIATE RAILS OR OTHER CONSTRUCTION | | | SHALL NOT PERMIT A SPHERE WITH A | | | DIAMETER OF 21 INCHES (533 MM) TO PASS THROUGH ANY | | | OPENING. | | | | | | 9) THE FLOOR PLAN DOES NOT INDICATE THIS GENERATOR | | | BEING LOCATED IN A SEPERATE GENERATOR ROOM. | | | NFPA 110 .7.2.1.2 | | | NFPA 110. 7.2.2. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-07-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-15 |
Time |
15:39 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2009-07-15 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2009-07-15 15:45:02 | BUILDING PLAN REVIEW | | | PERMIT: 09040174 | | | ADD: 1590 FLORIDA MANGO | | | CONT: SOUTH EAST CERTIFIED CONTRACTORS | | | TEL: (561)635-6935 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | JUNE 15/09 | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | NONE OF THE COMMENTS WERE ADDRESSED FROMTHE FIRST | | | REVIEW!!! | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH THE 2009 SUPPLEMENTS. | | | | | | 1C) THE LOCATION OF THIS PROJECT IS LOCATED WITHIN A | | | A-9 FLOOD-ZONE REQUIRING A MINIMUM ELEVATION OF THE | | | SLAB OF 13.5'. | | | | | | 1D) (2007 FBC) 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE & | | | EXTENT OF THE WORK PROPOSED & SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, AND RULES AND REGULATIONS AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 2) IT APPEARS THE INSTALATION OF THIS GENERATOR AND | | | TANK ARE ON THE EXTERIOR OF THE BUILDING AND EXPOSED TO | | | WIND. PLEASE PROVIDE THE WIND DESIGN CRITERIA. 1603.1.4 | | | WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 2A). BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | | | | 2B). WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | | | 2C) . WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | | | | 2D). THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | | | | 3) THE PLAN DO NOT NDICATE IF THIS IS A NEW SLAB OR | | | REUSE OF AN EXISTING SLAB. 2702.1 INSTALLATION. | | | | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL BE INSTALLED | | | IN ACCORDANCE WITH THE NFPA 70, NATIONAL ELECTRICAL | | | CODE, NFPA 110 AND NFPA 111. | | | NFPA 110: | | | 3A) 7.4 MOUNTING. | | | | | | 7.4.1 ROTATING ENERGY CONVERTERS SHALL BE INSTALLED ON | | | SOLID FOUNDATIONS TO PROHIBIT SAGGING OF FUEL, EXHAUST, | | | OR LUBRICATING-OIL PIPING AND DAMAGE TO PARTS RESULTING | | | IN LEAKAGE AT JOINTS. | | | | | | 7.4.1.1 SUCH FOUNDATIONS OR STRUCTURAL BASES SHALL | | | RAISE THE ENGINE AT LEAST 150 MM (6 IN.) ABOVE THE | | | FLOOR OR GRADE LEVEL AND BE OF SUFFICIENT ELEVATION TO | | | FACILITATE LUBRICATING-OIL DRAINAGE AND | | | EASE OF MAINTENANCE. | | | | | | 7.4.2 FOUNDATIONS SHALL BE OF THE SIZE (MASS) AND TYPE | | | RECOMMENDED BY THE ENERGY CONVERTER MANUFACTURER. | | | | | | 7.4.3 WHERE REQUIRED TO PREVENT TRANSMISSION OF | | | VIBRATION DURING OPERATION, THE FOUNDATION SHALL BE | | | ISOLATED FROM THE SURROUNDING FLOOR OR OTHER | | | FOUNDATIONS, OR BOTH, IN ACCORDANCE WITH THE | | | MANUFACTURER'S RECOMMENDATIONS AND ACCEPTED STRUCTURAL | | | ENGINEERING PRACTICES. | | | | | | 7.4.4 THE EPS SHALL BE MOUNTED ON A FABRICATED METAL | | | SKID BASE OF THE TYPE THAT SHALL RESIST DAMAGE DURING | | | SHIPPING AND HANDLING. AFTER INSTALLATION, THE BASE | | | SHALL MAINTAIN ALIGNMENT OF THE | | | UNIT DURING OPERATION. PLANS DO NOT PROVIDE INFORMATION | | | FOR SECONDARY CONTAINMENT. NFPA 110: 7.9.12 LISTED | | | GENERATOR SUBBASE SECONDARY CONTAINMENT FUEL TANKS OF | | | 2498 L (660 GAL) | | | CAPACITY AND BELOW SHALL BE PERMITTED TO BE INSTALLED | | | OUTDOORS OR INDOORS WITHOUT DIKING OR REMOTE | | | IMPOUNDING. PLANS INDICATE 1200 GALLON CAPACITY. | | | | | | 4) PLANS FAIL TO PROVIDE INFORMATION FOR THE FOUNDATION | | | AND SLAB FOR GENERATOR A TANK, PLEASE PROVIDE DETAILS | | | FOR ANCHORING OF TANK AND GENERATOR AGAINST OVERTURNING | | | ,UPLIFT AND SLIPPAGE FBC | | | BUILDING 1609.1.3. | | | | | | 5) FOR MAINTENANCE AND WEEKLY VISUAL INSPECTION OF | | | GENERATOR A ELEVATED PLATFORM, STAIR AND GUARDRAIL | | | SYSTEM WILL BE REQUIRED. NFPA 110: 8.4 OPERATIONAL | | | INSPECTION AND TESTING. | | | | | | 8.4.1* EPSSS, INCLUDING ALL APPURTENANT COMPONENTS, | | | SHALL BE INSPECTED WEEKLY AND EXERCISED UNDER LOAD AT | | | LEAST MONTHLY. | | | | | | 6) STAIRS 1009.3 EXCEPTION# 7. INDUSTRIAL EQUIPMENT | | | ACCESS STAIRS AND LANDINGS THAT SERVE AS A COMPONENT OF | | | THE MEANS OF EGRESS FROM THE INVOLVED EQUIPMENT AND DO | | | NOT SERVE MORE THAN | | | 20 PEOPLE SHALL BE PERMITTED TO HAVE A MINIMUM CLEAR | | | WIDTH OF 22 INCHES (559 MM), MINIMUM TREAD DEPTH OF 10 | | | INCHES (254 MM), MAXIMUM RISER HEIGHT OF 9 INCHES (229 | | | MM), MINIMUM | | | HEADROOM OF 6 FEET 8 INCHES (2032 MM), AND A MAXIMUM | | | HEIGHT BETWEEN LANDINGS OF 12 FEET (36 576 MM). | | | | | | 7) GAURDRAILS: 1012.1 WHERE REQUIRED. | | | GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING | | | SURFACES, INDUSTRIAL EQUIPMENT PLATFORMS, LANDINGS | | | WHICH ARE LOCATED MORE THAN 30 INCHES (762 MM) ABOVE | | | THE FLOOR OR GRADE BELOW. | | | GUARDS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN | | | ACCORDANCE WITH SECTION 1607.7. | | | | | | 8) GUARD 1012.3 OPENING LIMITATIONS. EXCEPTIONS: | | | 2. AT ELEVATED WALKING SURFACES FOR ACCESS TO AND USE | | | OF ELECTRICAL, MECHANICAL OR PLUMBING SYSTEMS OR | | | EQUIPMENT, GUARDS SHALL HAVE BALUSTERS OR BE OF SOLID | | | MATERIALS SUCH THAT A | | | SPHERE WITH A DIAMETER OF 21 INCHES (533 MM) CANNOT | | | PASS THROUGH ANY OPENING. | | | 3. IN AREAS WHICH ARE NOT OPEN TO THE PUBLIC WITHIN | | | OCCUPANCIES IN GROUP I-3, F, H OR S, BALUSTERS, | | | HORIZONTAL INTERMEDIATE RAILS OR OTHER CONSTRUCTION | | | SHALL NOT PERMIT A SPHERE WITH A | | | DIAMETER OF 21 INCHES (533 MM) TO PASS THROUGH ANY | | | OPENING. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-04-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-09 |
Time |
17:33 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2009-04-09 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2009-04-09 17:39:24 | BUILDING PLAN REVIEW | | | PERMIT: 09040174 | | | ADD: 1590 FLORIDA MANGO | | | CONT: SOUTH EAST CERTIFIED CONTRACTORS | | | TEL: (561)635-6935 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | JULY 15/09 | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH THE 2009 SUPPLEMENTS. | | | | | | 1C) THE LOCATION OF THIS PROJECT IS LOCATED WITHIN A | | | A-9 FLOOD-ZONE REQUIRING A MINIMUM ELEVATION OF THE | | | SLAB OF 13.5'. | | | | | | 1D) (2007 FBC) 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE & | | | EXTENT OF THE WORK PROPOSED & SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, AND RULES AND REGULATIONS AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 2) IT APPEARS THE INSTALATION OF THIS GENERATOR AND | | | TANK ARE ON THE EXTERIOR OF THE BUILDING AND EXPOSED TO | | | WIND. PLEASE PROVIDE THE WIND DESIGN CRITERIA. 1603.1.4 | | | WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 2A). BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | | | | 2B). WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | | | 2C) . WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | | | | 2D). THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | | | | 3) THE PLAN DO NOT NDICATE IF THIS IS A NEW SLAB OR | | | REUSE OF AN EXISTING SLAB. 2702.1 INSTALLATION. | | | | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL BE INSTALLED | | | IN ACCORDANCE WITH THE NFPA 70, NATIONAL ELECTRICAL | | | CODE, NFPA 110 AND NFPA 111. | | | NFPA 110: | | | 3A) 7.4 MOUNTING. | | | | | | 7.4.1 ROTATING ENERGY CONVERTERS SHALL BE INSTALLED ON | | | SOLID FOUNDATIONS TO PROHIBIT SAGGING OF FUEL, EXHAUST, | | | OR LUBRICATING-OIL PIPING AND DAMAGE TO PARTS RESULTING | | | IN LEAKAGE AT JOINTS. | | | | | | 7.4.1.1 SUCH FOUNDATIONS OR STRUCTURAL BASES SHALL | | | RAISE THE ENGINE AT LEAST 150 MM (6 IN.) ABOVE THE | | | FLOOR OR GRADE LEVEL AND BE OF SUFFICIENT ELEVATION TO | | | FACILITATE LUBRICATING-OIL DRAINAGE AND | | | EASE OF MAINTENANCE. | | | | | | 7.4.2 FOUNDATIONS SHALL BE OF THE SIZE (MASS) AND TYPE | | | RECOMMENDED BY THE ENERGY CONVERTER MANUFACTURER. | | | | | | 7.4.3 WHERE REQUIRED TO PREVENT TRANSMISSION OF | | | VIBRATION DURING OPERATION, THE FOUNDATION SHALL BE | | | ISOLATED FROM THE SURROUNDING FLOOR OR OTHER | | | FOUNDATIONS, OR BOTH, IN ACCORDANCE WITH THE | | | MANUFACTURER'S RECOMMENDATIONS AND ACCEPTED STRUCTURAL | | | ENGINEERING PRACTICES. | | | | | | 7.4.4 THE EPS SHALL BE MOUNTED ON A FABRICATED METAL | | | SKID BASE OF THE TYPE THAT SHALL RESIST DAMAGE DURING | | | SHIPPING AND HANDLING. AFTER INSTALLATION, THE BASE | | | SHALL MAINTAIN ALIGNMENT OF THE | | | UNIT DURING OPERATION. PLANS DO NOT PROVIDE INFORMATION | | | FOR SECONDARY CONTAINMENT. NFPA 110: 7.9.12 LISTED | | | GENERATOR SUBBASE SECONDARY CONTAINMENT FUEL TANKS OF | | | 2498 L (660 GAL) | | | CAPACITY AND BELOW SHALL BE PERMITTED TO BE INSTALLED | | | OUTDOORS OR INDOORS WITHOUT DIKING OR REMOTE | | | IMPOUNDING. PLANS INDICATE 1200 GALLON CAPACITY. | | | | | | 4) PLANS FAIL TO PROVIDE INFORMATION FOR THE FOUNDATION | | | AND SLAB FOR GENERATOR A TANK, PLEASE PROVIDE DETAILS | | | FOR ANCHORING OF TANK AND GENERATOR AGAINST OVERTURNING | | | ,UPLIFT AND SLIPPAGE FBC | | | BUILDING 1609.1.3. | | | | | | 5) FOR MAINTENANCE AND WEEKLY VISUAL INSPECTION OF | | | GENERATOR A ELEVATED PLATFORM, STAIR AND GUARDRAIL | | | SYSTEM WILL BE REQUIRED. NFPA 110: 8.4 OPERATIONAL | | | INSPECTION AND TESTING. | | | | | | 8.4.1* EPSSS, INCLUDING ALL APPURTENANT COMPONENTS, | | | SHALL BE INSPECTED WEEKLY AND EXERCISED UNDER LOAD AT | | | LEAST MONTHLY. | | | | | | 6) STAIRS 1009.3 EXCEPTION# 7. INDUSTRIAL EQUIPMENT | | | ACCESS STAIRS AND LANDINGS THAT SERVE AS A COMPONENT OF | | | THE MEANS OF EGRESS FROM THE INVOLVED EQUIPMENT AND DO | | | NOT SERVE MORE THAN | | | 20 PEOPLE SHALL BE PERMITTED TO HAVE A MINIMUM CLEAR | | | WIDTH OF 22 INCHES (559 MM), MINIMUM TREAD DEPTH OF 10 | | | INCHES (254 MM), MAXIMUM RISER HEIGHT OF 9 INCHES (229 | | | MM), MINIMUM | | | HEADROOM OF 6 FEET 8 INCHES (2032 MM), AND A MAXIMUM | | | HEIGHT BETWEEN LANDINGS OF 12 FEET (36 576 MM). | | | | | | 7) GAURDRAILS: 1012.1 WHERE REQUIRED. | | | GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING | | | SURFACES, INDUSTRIAL EQUIPMENT PLATFORMS, LANDINGS | | | WHICH ARE LOCATED MORE THAN 30 INCHES (762 MM) ABOVE | | | THE FLOOR OR GRADE BELOW. | | | GUARDS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN | | | ACCORDANCE WITH SECTION 1607.7. | | | | | | 8) GUARD 1012.3 OPENING LIMITATIONS. EXCEPTIONS: | | | 2. AT ELEVATED WALKING SURFACES FOR ACCESS TO AND USE | | | OF ELECTRICAL, MECHANICAL OR PLUMBING SYSTEMS OR | | | EQUIPMENT, GUARDS SHALL HAVE BALUSTERS OR BE OF SOLID | | | MATERIALS SUCH THAT A | | | SPHERE WITH A DIAMETER OF 21 INCHES (533 MM) CANNOT | | | PASS THROUGH ANY OPENING. | | | 3. IN AREAS WHICH ARE NOT OPEN TO THE PUBLIC WITHIN | | | OCCUPANCIES IN GROUP I-3, F, H OR S, BALUSTERS, | | | HORIZONTAL INTERMEDIATE RAILS OR OTHER CONSTRUCTION | | | SHALL NOT PERMIT A SPHERE WITH A | | | DIAMETER OF 21 INCHES (533 MM) TO PASS THROUGH ANY | | | OPENING. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2009-08-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-08-06 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-08-06 |
Time |
07:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2009-07-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-24 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-24 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2009-07-24 18:40:58 | | | | ** DENIED ** | | | | | | 1) NOTE: PLEASE SUBMIT MANUFACTURES SPECS FOR ONE | | | PRODUCT FOR ATS. THERE IS SUBMITTALS FOR CATERPILLAR | | | EQUIPMENT AND ALSO LAKE SHORE. WHICH ONE WILL BE USED? | | | 110.3,90.7 | | | | | | 2) NOTE: THE SUBMITTED SP-1 AND RP-1 SHEETS ARE NOT | | | SIGNED DATED OR SEALED BY THE RESPONSIBLE DESIGNER OF | | | RECORD. SEE COMMENTS FROM OTHER TRADES | | | FS 481.221 | | | | | | 3) NOTE: THE SUBMITTED LP-1 THROUGH LP-4 CONTAINED | | | RAISED SEALS OVER PHOTO-COPIED SIGNATURES. THIS DOES | | | NOT MEET THE MINIMUM UNDER FLORIDA STATUTES 481.221. | | | ALL COPIES IN BOTH SETS SHALL BE RETAINED BY THIS | | | OFFICE. | | | | | | 4) NOTE: PLANS SUBMITTED DO NOT CONTAIN ANY STRUCTURAL | | | DETAILS FOR SLAB. SEE COMMENTS FROM BUILDING REVIEW | | | WITH RESPECT TO NO INFORMATION FOR SLAB, STAIRS AND | | | PLATFORM. | | | | | | 5) NOTE: RISER INDICATES GROUND FAULT PROTECTION ON THE | | | 800AMP BREAKER ON GENERATOR?? PLEASE HAVE ENGINEER CALL | | | TO GO OVER THIS AS HAVING *GROUND FAULT PROTECTION* | | | WILL CREATE A LACK OF COORDINATION FOR GENERATOR BACK | | | UP. THIS IS NOT THE SAME AS GROUND FAULT SENSING AND | | | THE COORDINATION OF POWER TRANSFER BACK TO NORMAL | | | POWER. | | | | | | | | | | | | ** EMAIL WAS SENT TO OFFICE OF ENGINEER TO CALL AND GO | | | OVER PLANS SPECIFIC TO COMMENT #4. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-07-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-22 |
Time |
19:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-22 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2009-07-22 19:39:31 | | | | | | | TO DOUG./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-05 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-05 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2009-07-05 16:11:11 | | | | | | | | | | | | | | | | | | | ** DENIED 2ND PLANS REVIEW ** | | | | | | 1) NOTE: THIS COMMENT WAS IGNORED: PERMIT APPLICATION | | | VALUE SHALL INCLUDE: ALL LABOR, MATERIALS, EQUIPMENT, | | | DESIGN COST ETC. AN APPLIED VALUE OF $12K DOES NOT | | | COVER THE GENERATOR LET ALONE THE TRANSFER EQUIPMENT, | | | SLAB WORK, ELECTRICAL, UNDERGROUND OR FUEL TANK. | | | IF AN APPROPRIATE VALUE IS NOT STATED FOR COMPLETE | | | SCOPE ONE WILL BE ASSESSED USING THE ADOPTED GUIDES FOR | | | VALUE AND INCLUDING PRICING PROVIDED FROM MANUFACTURES. | | | FBC 108.3 | | | | | | 2) NOTE: THIS COMMENT REMAINS AS THERE IS NOT ENOUGH | | | INFORMATION FOR OTHER TRADES WHICH WILL CREATE 2ND | | | ROUND OF COMMENTS FOR OTHER REVIEWS AS WELL. | | | **PLEASE BE SURE TO SEE ALL COMMENTS FROM OTHER TRADES | | | AS THERE WILL BE COMMENTS WITH RESPECT TO FUEL SIZE AND | | | THE REQUIREMENT FOR AN ACCESS PLATFORM TO SERVICE | | | EQUIPMENT PER NFPA-110 2002 AND FBC. | | | THERE WILL BE COMMENTS WITH RESPECT TO MOUNTING, AND | | | THE ACTUAL FUEL TANK PLANS NEEDING THE DERM STAMPS. | | | ** THIS IS NOTED SO THAT DESIGN TEAM AND CONTRACTOR | | | WILL BE AWARE TO SEE OTHER COMMENTS BEFORE MAKING | | | DESIGN CHANGES. | | | | | | 3) NOTE: REPEAT COMMENT: PLEASE SUBMIT THE MANUFACTURES | | | SPECS/CUT SHEETS FOR ALL EQUIPMENT. THIS SHALL INCLUDE | | | ATS EQUIPMENT, GENERATOR, AND FUEL TANK. (TANK REVIEWED | | | BY OTHER TRADES). | | | NEC 90.7,110.3, 702.6 | | | | | | 4) NOTE: SAME NOTE, THE ATS IS STILL SHOWN AS 3-POLE. | | | THERE WILL BE A LACK OF COORDINATION OF EQUIPMENT AND | | | WHEN POWER TRANSFER BACK TO NORMAL POWER. | | | | | | **PREVIOUS NOTE: | | | PLEASE SEE ORIGINAL NOTES FOR BUILDING. THE CODE | | | REQUIRES GROUND FAULT PROTECTION ON MAIN. THIS IS GIVEN | | | FOR INFORMATION AS THIS IS ONLY A NEC 702 SYSTEM. | | | AS THERE IS GROUND FAULT PROTECTION ON THE MAIN AND THE | | | USE OF A THREE POLE TRANSFER SWITCH THIS MAY CREATE A | | | LACK OF COORDINATION OR TRIPPING OF MAIN WITHOUT THE | | | USE OF A FOUR POLE TRANSFER SWITCH. IF THIS WAS A 700 | | | OR 701 SYSTEM THERE ARE SPECIFIC CODE SECTIONS WHICH | | | REQUIRE GROUND FAULT SENSING ON THE BACK UP SYSTEM. | | | PLEASE SEE NFPA-110 6.2.15 WHEN GROUND FAULT SENSING IS | | | REQUIRED OR PROVIDED THIS WOULD REQUIRE THE ISOLATION | | | OF NEUTRALS THUS A FOUR POLE TRANSFER SWITCH. | | | *** PLEASE BE AWARE OF THIS AS THIS MAY BE AN | | | OPERATIONAL ITEM WHICH DEPENDING ON EQUIPMENT ORDERED | | | MAY CREATE A LOSS OF COORDINATION OR NO OPERATION AT | | | ALL. | | | ** PLEASE SEE WHITE PAPERS BY CATERPILLAR, ASCO AND | | | MANY OTHER TRANSFER SWITCH MANUFACTURES ON THIS TOPIC. | | | ** THIS COMMENT IS ONLY MADE TO HELP IN THE DESIGN AS | | | THIS IS A 702 SYSTEM NO BACK UP OF POWER IS REQUIRED | | | FOR ANY 701 AND 702 SYSTEMS IN BUILDING. | | | | | | 5) NOTE: NEW SITE PLANS ARE IN FACT PHOTO-COPIES OF | | | SIGNED, DATED AND SEALED PLANS BY A DESIGN PROFESSIONAL | | | WHICH IS NOT PERMITTED. | | | FS 481.221, 471.025 | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-12 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-12 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2009-04-12 10:15:02 | ** DENIED** | | | | | | 1) NOTE: PLANS ARE STATING ALL DESIGNS PER 2004 FBC. | | | ANY PLANS SUBMITTED FOR PER AFTER MARCH 1ST, 2009 MUST | | | BE UNDER THE NEW 2007 FBC WITH 2009 AMENDMENTS. | | | THE FAC 69A-60.003 AND 004 HAS ALSO REVISED ADOPTING | | | THE NEW NFPA-1 AND NFPA-101 | | | | | | PLEASE BE SURE THE FOLLOWING CODES ARE STATED ON PLANS | | | AT A MINIMUM. | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2007 FBC W/ 2009 REVISIONS. | | | 2006 NFPA-101 | | | 2006 NFPA-1 | | | | | | 2) NOTE: PERMIT APPLICATION VALUE SHALL INCLUDE: ALL | | | LABOR, MATERIALS, EQUIPMENT, DESIGN COST ETC. AN | | | APPLIED VALUE OF $12K DOES NOT COVER THE GENERATOR LET | | | ALONE THE TRANSFER EQUIPMENT, SLAB WORK, ELECTRICAL, | | | UNDERGROUND OR FUEL TANK. | | | IF AN APPROPRIATE VALUE IS NOT STATED FOR COMPLETE | | | SCOPE ONE WILL BE ASSESSED USING THE ADOPTED GUIDES FOR | | | VALUE AND INCLUDING PRICING PROVIDED FROM MANUFACTURES. | | | FBC 108.3 | | | | | | 3) NOTE: PLEASE BE SURE TO SEE ALL COMMENTS FROM OTHER | | | TRADES AS THERE WILL BE COMMENTS WITH RESPECT TO FUEL | | | SIZE AND THE REQUIREMENT FOR AN ACCESS PLATFORM TO | | | SERVICE EQUIPMENT PER NFPA-110 2002 AND FBC. | | | THERE WILL BE COMMENTS WITH RESPECT TO MOUNTING, AND | | | THE ACTUAL FUEL TANK PLANS NEEDING THE DERM STAMPS. | | | ** THIS IS NOTED SO THAT DESIGN TEAM AND CONTRACTOR | | | WILL BE AWARE TO SEE OTHER COMMENTS BEFORE MAKING | | | DESIGN CHANGES. | | | | | | 4) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS FOR ALL EQUIPMENT. THIS SHALL INCLUDE ATS | | | EQUIPMENT, GENERATOR, AND FUEL TANK. (TANK REVIEWED BY | | | OTHER TRADES). | | | NEC 90.7,110.3, 702.6 | | | | | | 5) NOTE: PLEASE SEE ORIGINAL NOTES FOR BUILDING. THE | | | CODE REQUIRES GROUND FAULT PROTECTION ON MAIN. THIS IS | | | GIVEN FOR INFORMATION AS THIS IS ONLY A NEC 702 SYSTEM. | | | AS THERE IS GROUND FAULT PROTECTION ON THE MAIN AND THE | | | USE OF A THREE POLE TRANSFER SWITCH THIS MAY CREATE A | | | LACK OF COORDINATION OR TRIPPING OF MAIN WITHOUT THE | | | USE OF A FOUR POLE TRANSFER SWITCH. IF THIS WAS A 700 | | | OR 701 SYSTEM THERE ARE SPECIFIC CODE SECTIONS WHICH | | | REQUIRE GROUND FAULT SENSING ON THE BACK UP SYSTEM. | | | PLEASE SEE NFPA-110 6.2.15 WHEN GROUND FAULT SENSING IS | | | REQUIRED OR PROVIDED THIS WOULD REQUIRE THE ISOLATION | | | OF NEUTRALS THUS A FOUR POLE TRANSFER SWITCH. | | | *** PLEASE BE AWARE OF THIS AS THIS MAY BE AN | | | OPERATIONAL ITEM WHICH DEPENDING ON EQUIPMENT ORDERED | | | MAY CREATE A LOSS OF COORDINATION OR NO OPERATION AT | | | ALL. | | | ** PLEASE SEE WHITE PAPERS BY CATERPILLAR, ASCO AND | | | MANY OTHER TRANSFER SWITCH MANUFACTURES ON THIS TOPIC. | | | ** THIS COMMENT IS ONLY MADE TO HELP IN THE DESIGN AS | | | THIS IS A 702 SYSTEM NO BACK UP OF POWER IS REQUIRED | | | FOR ANY 701 AND 702 SYSTEMS IN BUILDING. | | | | | | 6) NOTE: PLEASE SEE 225.31-225.39 FOR THE REQUIRED | | | DISCONNECTING MEANS FOR FEEDERS AT THE BUILDING. THIS | | | WAS NOTED ON THE ORIGINAL PLANS HOWEVER THE GENERATOR | | | WAS REMOVED FORM PLANS. THIS REVIEWER STATED TO BE | | | AWARE OF THIS CODE SECTION ON FUTURE PLANS. NEC | | | 700.12B6, 701.11B5 AND 702.11 ALL STATE THAT WHEN | | | DISCONNECTING MEANS FROM THE GENERATOR IS LOCATED | | | WITHIN SIGHT AND READILY ACCESSIBLE THEN AN ADDITIONAL | | | DISCONNECTING MEANS IS NOT REQUIRED AT THE BUILDING IN | | | WHICH THE FEEDERS SERVE. THE GENERATOR IS LOCATED | | | WITHIN SIGHT PER DEFINITIONS HOWEVER THE DISCONNECTING | | | MEANS AT GENERATOR MAY NOT BE READILY ACCESSIBLE. IN A | | | LOCKED ENCLOSURE OR BEHIND A WALL/GATES LOCKED DOES NOT | | | PERMIT READY ACCESS FOR FIRE DEPARTMENT OR ANY OTHER | | | PERSONNEL. SEE ZONING COMMENTS AS THE GENERATOR WILL BE | | | REQUIRED TO CONTAIN A WALL OR FENCE IN ETC. THE | | | ENCLOSURE OF THE GENERATOR ALONE DOES NOT PERMIT READY | | | ACCESS WITH THE BREAKER LOCKED INSIDE. | | | PLEASE KNOW THAT A DISCONNECTING MEANS DOES NOT REQUIRE | | | OVER CURRENT PROTECTION WHEN THE OCP IS ALREADY | | | PROVIDED BY THE GENERATOR. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
ENG-F |
ENGINEERING FINAL DRAWING REV |
| Rev No |
1 |
Status |
P |
Date |
2009-07-17 |
|
|
Cont ID |
|
| Sent By |
efabian |
Date |
2009-07-17 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
efabian |
Date |
2009-07-17 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2009-07-17 11:41:22 | PASSED | | | | | | CIVIL PLANS SETS RESUBMITTED 7-14-09 CONSISTING OF NEW | | | POTABLE 4 INCH WATER SERVICES AND CROSS CONNECTIONS | | | ACCEPTABLE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-08-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-08-10 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-08-10 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2009-08-10 11:09:37 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A010 AND RP 1 WERE STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-04-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-04-16 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-04-16 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2009-04-16 12:36:52 | *****DENIED***** | | | | | | 1. THE PROJECT SITE ADDRESS SHALL BE IN THE TITLE BLOCK | | | OF EACH SUBMITTED PLAN SHEET. NO ADDRESS LISTED ON | | | SHEETS E-1, E-2, AND E-3. | | | | | | 2. UPDATE CODE INFORMATION ON SHEET E-1 TO REFLECT | | | CURRENT EDITIONS OF NFPA 101 (2006) AND NFPA 110 (2005) | | | WHICH ARE TO BE REFERENCED. | | | | | | 3. ARE ANY DEVICES PLANNED TO PREVENT THE GENERATOR | | | FROM RECEIVING MECHANICAL DAMAGE FROM VEHICLES. | | | | | | 4. SHOW/ILLUSTRATE DISTANCE FROM THE GENERATOR/SLAB | | | SETUP TO THE EDGE OF THE ONE WAY ASPHALT DRIVE. | | | | | | 5. SHOW/ILLUSTRATE DISTANCES TO THE NEAREST BUILDING(S) | | | OPENINGS SUCH AS WINDOWS AND DOORS. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET | | | EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
2 |
Status |
P |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-07 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-07 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
F |
Date |
2009-07-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-20 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-20 |
Time |
15:42 |
Sent To |
M |
|
| Notes |
| 2009-07-20 15:43:29 | PROVIDE TWO SETS OF PBC DERM APPROVED PLANS, ONE OFR | | | FILE SET AND ONE FOR FIELD SET. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-08-03 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-03 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-07-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-24 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-24 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2009-07-24 17:30:22 | TO C10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-06-19 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-06-19 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-04-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-09 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2009-04-09 10:41:02 | TO "C3" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-08-18 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-18 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-18 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-08-18 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-06 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-06 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2009-08-06 16:54:44 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE ADDRESS THE ZONING COMMENTS MADE ON 7/29/09. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-08-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-06 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-06 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2009-08-06 11:54:31 | MISSING PAGES SUPPLIED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2009-08-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-05 |
Time |
20:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-05 |
Time |
20:12 |
Sent To |
|
|
| Notes |
| 2009-08-05 20:38:34 | REVIEW COMPLETE. ONE SET OF PLANS IS COMPLIANT AND | | | CONTAINS REVISED PAGE SP-1 WITH DERM APPROVAL AND PAGE | | | RP-1. THIS WOULD BE ADEQUATE FOR A PASSED MECHANICAL | | | REVIEW. HOWEVER, THE 2ND SET OF PLANS IS MISSING THESE | | | TWO PAGES. REVIEW CANNOT BE PASSED UNTIL TWO COMPLETE | | | AND MATCHING SETS OF PLANS ARE SUBMITTED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2009-07-27 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-27 |
Time |
20:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-27 |
Time |
20:23 |
Sent To |
|
|
| Notes |
| 2009-07-27 20:38:17 | DENIED | | | | | | WRITTEN RESPONSE FROM ARCHITECT INDICATES PBC DERM | | | APPROVED PLANS WERE INCLUDED. PAGE SP-1 WHICH WAS | | | PREVIOUSLY APPROVED BY DERM HAS BEEN REVISED AND MUST | | | BE RE-SUBMITTED TO DERM FOR APPROVAL PRIOR TO PERMIT | | | ISSUANCE. PLEASE PROVIDE TWO COPIES OF DERM APPROVED | | | PLANS (PAGE SP-1 AND TANK SUBMITTAL) UPON RESUBMISSION. | | | | | | NOTE: GENERATOR EXHAUST SHALL BE MINIMUM 10' (MEASURED | | | HORIZONTALLY) FROM OUTSIDE AIR INTAKES AND OPENINGS | | | INTO THE BUILDING INACCORDANCE WITH FBC-M 401.5. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-07-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-20 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-20 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2009-07-20 15:44:11 | PREVIOUS REVIEW COMMENTS NOT ADDRESSED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-14 |
Time |
19:19 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-14 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2009-04-14 19:19:09 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PLEASE ADJUST THE PROVIDED PERMIT VALUATION TO | | | INCLUDE ALL EQUIPMENT, MATERIALS, LABOR AND DESIGN | | | COSTS ASSOCIATED WITH THIS SCOPE OF WORK, INCLUDING THE | | | GENERATOR, FUEL TANK, TRANSFER SWITCHES, ELECTRICAL | | | WORK, ETC. | | | | | | 2. PLEASE PROVIDE MANUFACTURER'S SUBMITTAL DATA FOR THE | | | SUB BASE FUEL TANK SHOWING LISTINGS AND RATINGS AS | | | REQUIRED IN ACCORDANCE WITH FBC-M 915. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-08-17 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-08-17 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-08-17 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2009-08-17 09:30:31 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 09040174 | | | ADDRESS: 1590 FLORIDA MANGO ROAD | | | CONTRACTOR/CONTACT: NAT HEALY | | | TELEPHONE NO.: 635.6935 | | | SCOPE OF REVIEW: EMERGENCY GENERATOR | | | | | | REVIEW STATUS: PASSED WITH PROVISO | | | | | | THE PERMIT IS ISSUED SUBJECT TO THE FOLLOWING: | | | | | | 1) THE SITE PLAN AND LANDSCAPE PLANS SUBMITTED AND | | | APPROVED AS PART OF BLDG. PERMIT NO. 08090611 SHALL BE | | | REVISED TO SHOW THE ACCURATE LOCATION OF THE GENERATOR, | | | ALLOWING ALL PERMITS/PLANS TO BE CONSISTENT. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1459 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-07-30 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-07-30 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-07-30 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2009-07-30 17:32:43 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 09040174 | | | ADDRESS: 1590 FLORIDA MANGO ROAD | | | CONTRACTOR/CONTACT: NAT HEALY | | | TELEPHONE NO.: 635.6935 | | | SCOPE OF REVIEW: EMERGENCY GENERATOR | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | THE COMMENT BELOW IS A REPEAT COMMENT... | | | | | | 1) THE SITE PLAN SUBMITTED WITH THIS PERMIT DOES NOT | | | MATCH THAT SUBMITTED AND APPROVED AS PART OF BLDG. | | | PERMIT NO. 08090611. BLDG. PERMIT NO. 08090611 WILL | | | NEED TO BE REVISED TO PROVIDE FOR THE REVISED LOCATION | | | OF THE GENERATOR (THIS WILL INCLUDE THE SITE AND | | | LANDSCAPE PLANS). | | | | | | A PROVISO WAS NOT ISSUED AS THIS APPLICATION HAS FAILED | | | OTHER TRADES. PLEASE TRY TO ADDRESS THE COMMENT | | | PROVIDED ABOVE SO AS TO AVOID HAVING A PROVISO. IF ALL | | | OTHER TRADES HAVE PASSED THE APPLICATION AND THE ABOVE | | | COMMENT REMAINS, A PROVISO WILL BE CONSIDERED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1459 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-06-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-06-24 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-06-24 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2009-06-24 14:55:35 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 09040174 | | | ADDRESS: 1590 FLORIDA MANGO ROAD | | | CONTRACTOR/CONTACT: NAT HEALY | | | TELEPHONE NO.: 635.6935 | | | SCOPE OF REVIEW: EMERGENCY GENERATOR | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | THE COMMENT BELOW IS A REPEAT COMMENT....ADDITIONAL | | | INFORMATION IS PROVIDED IN ALL CAPS. | | | | | | 1) PURUSANT TO SECTION 94-444(B) OF THE CITY'S ZONING | | | AND LAND DEVELOPMENT REGULATIONS, GENERATORS SHALL BE | | | SCREENED. SCREENING SHALL CONSIST OF BRICK, DECORATIVE | | | CONCRETE, OTHER DECORATIVE MASONRY, OR COMPARABLY | | | DURABLE WOOD AND STEEL. THE SCREENING SHALL COMPLETELY | | | OBSCURE THE PROPOSED GENERATOR. IN ADDITION, THE | | | SCREENING SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES | | | PLANTED AT TWO-FOOT INTERVALS. THE SITE PLAN SUBMITTED | | | WITH THIS PERMIT DOES NOT MATCH THAT SUBMITTED AND | | | APPROVED AS PART OF BLDG. PERMIT NO. 08090611. BLDG. | | | PERMIT NO. 08090611 WILL NEED TO BE REVISED TO PROVIDE | | | FOR THE REVISED LOCATION OF THE GENERATOR (THIS WILL | | | INCLUDE THE SITE AND LANDSCAPE PLANS). ADDITIONALLY, | | | DETAILS WILL NEED TO BE PROVIDED REGARDING THE PROPOSED | | | SCREENING. THE PLANS SHOW A CONCRETE WALL, BUT NO | | | STRUCTURAL DETAILS HAVE BEEN PROVIDED (I.E. HEIGHT, | | | ETC.). PLEASE PROVIDE THIS INFORMATION. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1459 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-04-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-04-15 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-04-15 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2009-04-15 10:40:55 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 09040174 | | | ADDRESS: 1590 FLORIDA MANGO ROAD | | | CONTRACTOR/CONTACT: NAT HEALY | | | TELEPHONE NO.: 635.6935 | | | SCOPE OF REVIEW: EMERGENCY GENERATOR | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1) PURUSANT TO SECTION 94-444(B) OF THE CITY'S ZONING | | | AND LAND DEVELOPMENT REGULATIONS, GENERATORS SHALL BE | | | SCREENED. SCREENING SHALL CONSIST OF BRICK, DECORATIVE | | | CONCRETE, OTHER DECORATIVE MASONRY, OR COMPARABLY | | | DURABLE WOOD AND STEEL. THE SCREENING SHALL COMPLETELY | | | OBSCURE THE PROPOSED GENERATOR. IN ADDITION, THE | | | SCREENING SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES | | | PLANTED AT TWO-FOOT INTERVALS. | | | | | | 2) SETBACKS SHALL BE PROVIDED ON THE SITE PLAN SHOWING | | | THE DISTANCE BETWEEN THE GENERATOR AND THE PROPERTY | | | LINE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. | | | |
|
|
|