Plan Review Details - Permit 09040009
Plan Review Stops For Permit 09040009
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-05-15 Cont ID  
Sent By jwitmer Date 2009-05-15 Time 14:00 Rev Time 1.11
Received By jwitmer Date 2009-05-15 Time 13:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-02 Cont ID  
Sent By jwitmer Date 2009-04-02 Time 10:43 Rev Time 1.25
Received By jwitmer Date 2009-04-02 Time 10:43 Sent To PC
Notes
2009-04-02 10:45:33BUILDING PLAN REVIEW
 PERMIT: 09040009
 ADD: 900 BRANDYWINE RD.
 CONT: SOUTHERN COAST ENTERPRIZE INC.
 TEL: (954)426-3312
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 ROOFING PRODUCT APPROVALS WHICH WERE SUBMITTED UNDER
 THE MAIN BUILDING PERMIT AND REVIEWED:
 07110731 MAIN BUILDING PERMIT
 BUILDING PROVISO: FOR ROOF PERMIT A LAYOUT SHEET
 SHOWING STEPPED INSULATION WITH R-VALUES MATCHING THE
 ENERGY CALCULATIONS
 1056 MTL BLDG ROOF/ R-19 BATT RVALUE 20.3
  
 ROOF TILE SANTAFE TILE CORP MISSION BARREL ROOF TILE
 NOA 07-0626.04
 POLYFOAM - POLYPRO AH160 NOA 06-0201.02 REPLACES
 EXPIRED 01-0521.02
 INFORMAL INTERPRETATION# 5438 MINIMUM R-VALUES AT ROOF
 DRAIN
 JOHN MANVILLE MODIFIED BIT OVER STEEL DECK NOA
 07-0228.04
 SYSTEM TYPE: B(2) PAGES 9&10
 ON TARGET ENHANCED FASTENING REPORT
 END OF ROOF SUBMITTALS 12-09-08 J. WITMER
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) AS REQUESTED IN THE ORIGINAL BUILDING PROVISO, A
 ROOFING SHOP DRAWING INDICATING THE STEPPED INSULATION
 LAYOUT, TO BE REVIEWED BY THE DESIGNER OF RECORD AND
 REVIEWED WITH AFFIXED SHOP DRAWING STAMP OF APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC...
 106.3* PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 3) THE SECOND ISSUE WITH THE LINSULATION LAYOUT SHEET
 IS TAKING AN AVERAGE FOR THE R-19 VALUE. PLEASE REVIEW
 BOAF INFORMAL INTERPRETATION# 5438 THE MINIMUM OF R-19
 WOULD BE AT THE ROOF DRAINS. PLEASE SEE ATTACHMENT.
  
 4) THE M-2.3.0 IS A COPIED AND MINITURIZED OF A
 ORIGINAL SIGNED AND SEALED PLAN, PLEASE REVIEW PLANS
 FOR BUBLIC RECORD. 61G1-16.004 FL. ADMIN. CODE. PLANS
 PREPARED BY A REGISTERED ARCHITECT SHALL INCLUDE A
 TITLE BLOCK WHICH MUST:
 - STATE THE FIRM NAME, ADDRESS AND TELEPHONE NUMBER
 - STATE THE FIRM LICENSE NUMBER
 - STATE PROJECT NAME OR IDENTIFICATION
 - STATE DATE PREPARED
 - INCLUDE AN ORIGINAL SIGNATURE AND DATED SEALED
 INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING THE
 PLANS
  
 5) SUBMITTED ARE THE FLORIDA COVERSHEETS, SOME ARE FROM
 2001, 2004 & 2007. THIS PROJECT IS REVIEWED UNDER THE
 2004 CODE, PLEASE HAVE ALL PRODUCT APPROVALS TO BE
 SUBMITTED UNDER THE 2004 FBC. ALSO PROVIDE THE BACK UP
 REPORT WHICH ACCOMPANIES THE COVER SHEET.
 5A) MODIFIED BITUMEN- PLEASE INDICATE WHICH SUBSYSTEM
 WILL BE INSTALLED ON THIS PROJECT, ALSO IF ENHANCED
 FASTENING WILL BE REQUIRED PLEASE PROVIDE THE RAS 117
 CALCULATION.
 WITH NOT HAVING THE BACK UP REPORT, THE RAS 117
 CALCULATION MAY OR MAY NOT NEED TO BE COMPLETED BY A
 DESIGN PROFESSIONAL.
 5B) FL 1744 TAMKO UNDERLAYMENT PLEASE INDICATE FOR
 WHICH SYSTEM THIS WILL BE INSTALLEDHIGHLIGHTED USE
 INDICATES NOT TO BE USED ON APPLICATIONS LESS THAN
 2:12.
 5C) FL 9767 METAL ROOFING COVERSHEET ONLY SUBMITTED,
 MISSING THE BACK UP REPORT. PLEASE PROVIDE WHERE THIS
 MATERIAL WILL BE INSTALLED?
 5D) FL 738 ALTUSA TILE A 2001 REPORT, UPDATE TO THE
 2004 FBC REPORT WITH BACK UP REPORT. PROVIDE
 ATTAACHMENT METHOD, IT APPEARS TO BE FOAM PATTIES
 CIRCLE PATTY SIZE FOR UPLIFT CAPABILITIES.
 5E) FL 830 POLYFOAM A 2001 REPORT, UPDATE TO A 2004 FBC
 REPORT, CIRCLE PATTY SIZE FOR UPLIFT CAPABILITES.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-16 Cont ID  
Sent By rmcdouga Date 2009-07-16 Time 11:12 Rev Time 0.00
Received By rmcdouga Date 2009-07-15 Time 11:12 Sent To  
Notes
2009-07-16 11:13:00TO JWITMER'S DESK