| Plan Review Stops For Permit 09030575 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-05-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-05-20 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-05-20 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2009-05-20 09:08:52 | BUILDING PROVISO | | | | | | NOTE: ADDITIONAL ENGINEERED DETAILS MAY BE REQUESTED BY | | | THE BUILDING INSPECTOR TO ADDRESS SPECIFIC FIELD | | | CONDITION REPAIRS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-04-08 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-04-08 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2009-04-08 09:24:39 | 2007 FBC | | | LEVEL II ALTERATION | | | | | | DENIED BY BUILDING | | | | | | 1) UPDATE THE REFERENCES TO THE 2004 FBC IN THE GENERAL | | | NOTES AND STRUCTURAL NOTES ON SHEET CVR-1 TO THE 2007 | | | FBC WHICH IS THE APPLICABLE CODE. SEE REDLINED PLAN. | | | | | | 2) SUBMIT TWO (2) COPIES OF PRODUCT APPROVALS FOR THE | | | ASPHALT ROOF SHINGLES. DCA RULE 9B-72 | | | | | | NOTE: ADDITIONAL ENGINEERED DETAILS MAY BE REQUESTED BY | | | THE BUILDING INSPECTOR TO ADDRESS SPECIFIC FIELD | | | CONDITION REPAIRS. | | | | | | NOTE: A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | WILL BE REQUIRED.FS 713 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-04-07 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-04-07 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-11-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-11-03 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-11-03 |
Time |
06:49 |
Sent To |
Z |
|
| Notes |
| 2009-11-03 06:50:32 | TO ZONING./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-10-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-10-27 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-10-27 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2009-10-27 09:52:03 | MECHANICAL REVISION TO RM DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-10-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-22 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-22 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2009-10-22 11:18:38 | SENT TO ZONING/LANDSCAPE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-09-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-16 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-16 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2009-09-16 08:15:38 | SENT TO RMCDOUGAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-04-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-04-30 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-03-31 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2009-03-31 11:16:36 | TO "R8" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2009-11-03 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-11-03 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-11-03 |
Time |
17:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2009-10-22 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-10-22 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-10-22 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2009-10-22 16:13:19 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. FOR SINGLE FAMILY HOMES, ONE TREE IS REQUIRED FOR | | | 1200 SQUARE FEET OF OPEN SPACE--NOT 1600 SQUARE FEET. | | | FOUR (4) TREES ARE REQUIRED. THE EXISTING FICUS TREE | | | CAN COUNT TOWARD MEETING THIS REQUIREMENT . | | | | | | 2. PLEASE PROVIDE THE XERISCAPE DESIGN TABULATIONS. | | | | | | 3. PLACE A NOTE ON THE PLAN THAT IRRIGATION WILL BE | | | PROVIDED IN THE RIGHT-OF-WAY. | | | | | | 4. TYPICALLY, A THREE (3) INCH LAYER OF MULCH IS | | | APPLIED--NOT TWO (2) INCH. THE TREES AND SHRUBS SHALL | | | BE PLANTED SLIGHTLY ABOVE GRADE AND THE THREE (3) INCH | | | LAYER OF MULCH IS APPLIED OUTSIDE OF THE ROOTBALL. NO | | | MORE THAN A ONE INCH LAYER OF MULCH SHALL BE APPLIED | | | OVER THE ROOTBALL AND IT SHALL BE PULLED BACK FROM THE | | | TRUNK. | | | | | | 5. ALL EXISTING TREES AND SHRUBS TO REMAIN SHALL BE | | | FLORIDA #1 GRADE OR THEY SHALL BE REPLACED. IF THE | | | TREES DO NOT MEET THIS REQUIREMENT BUT COULD BE BROUGHT | | | UP TO THIS STANDARD BY CORRECTIVE PRUNING BY A | | | CERTIFIED ARBORIST, THEN THEY CAN REMAIN AND BE COUNTED | | | TOWARD MEETING THE REQUIREMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-05-28 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-05-22 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-05-22 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2009-05-22 14:58:38 | ***LANDSCAPE REVIEW PASSED WITH 'PROVISO'** | | | | | | LANDSCAPE PLAN THAT MEETS ALL MINIMUM REQUIREMENTS | | | PURSUANT TO ARTICLE XIV OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS SHALL BE SUBMITTED AND APPROVED | | | PRIOR TO C/O. IT SHALL CONTAIN ALL OF THE FOLLOWING: | | | | | | 1. PUSUANT TO SECTION 94-442 (D), PRIVATE LAND AND | | | PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK | | | SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN | | | SPACE AREAS SHALL BE PLANTED WITH GRASS. THIS INCLUDES | | | THE ENTIRE SITE AND RIGHTS-OF-WAY. | | | | | | 2. PURSUANT TO SECTION 94-445 (4)(G)(3), AUTOMATIC | | | IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED | | | LANDSCAPE AREAS FOR ALL PROPERTIES. THIS INCLUDES THE | | | RIGHTS-OF-WAY. | | | | | | 3. THE LANDSCAPE PLAN SHALL INCLUDE ALL ITEMS FOUND IN | | | SECTION 94-448 (D)(2), INCLUDING THE TABULATION CLEARLY | | | DISPLAYING THE RELEVATNT STATISTICAL INFORMATION | | | NECESSARY FOR THE EVALUATION OF COMPLIANCE WITH THE | | | PROVISIONS OF THIS ARTICLE. THE PLANT LIST SHALL | | | INCLUDE THE PLANT NAME, QUANTITY, SIZE AND SPACING OF | | | ALL ESISTING AND PROPOSED PLANT MATERIAL. ALL OVERHEAD | | | LINES, EASEMENTS, UTILITIES AND ANYTHING ELSE THAT | | | COULD INTERFERE WITH PROPOSED LANDSCAPING. | | | | | | 4. ALL TREES AND PLANT MATERIAL THAT WILL REMAIN SHALL | | | BE FLORIDA NUMBER 1 GRADE OR BETTER. EXISTING TREES | | | WILL NEED CORRECTIVE PRUNING BY A CERTIFIED ARBORIST IF | | | THEY ARE NOT IN GOOD CONDITION. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-10-27 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-10-27 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2009-10-28 07:25:25 | MECHANICAL REVISION REVIEWED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2009-09-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-09-17 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-09-17 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2009-09-17 10:19:21 | MECHANICAL REVISIONS TO SHEET M-1 ARE DENIED. | | | | | | 1) THE MECHANICAL REVISIONS ARE REQUIRED TO BE SIGNED | | | AND SEALED BY THE ARCHITECT THAT SEALED THE ORIGINAL | | | MECHANICAL DRAWINGS. FS 481. | | | | | | 2) THE PLANS ARE NOT CLEAR AND LEGIBLE. THE PLANS HAVE | | | "DEMO LICENSE NOT FOR RESALE" PRINTED ALL OVER THEM. | | | SUBMIT CLEAR LEGIBLE DRAWINGS. FBC 106.1.1 | | | | | | 3) THE REVISIONS ARE NOT CLEARLY IDENTIFIED ON THE | | | DRAWING. ITEMS THAT APPEAR TO BE ELIMINATED OR MOVED | | | ARE STILL SHOWN ON THE PLANS IN THE ORIGINAL LOCATIONS. | | | PLEASE CORRECT. FBC 106.1.1 | | | | | | 4) HAND WRITTEN CHANGES AND NOTATIONS ON THE PLANS CAN | | | ONLY BE DONE BY THE DESIGNER OF RECORD. FS 481 | | | | | | 5) THE REVISION NOTES THAT THE CONDENSING UNIT ON THE | | | EXTERIOR IS TO BE RELOCATED. INDICATE THE NEW LOCATION | | | OF THE CONDENSING UNIT ON THE PLANS. FBC 106.1.1 THE | | | NEW LOCATION WILL REQUIRE THE APPROVAL OF THE ZONING | | | DEPARTMENT. PROVIDE SURVEY OR SITE PLAN INDICATING THE | | | NEW LOCATION AND THE DISTANCES FROM PROPERTY LINES. | | | CONTACT THE ZONING DEPARTMENT FOR THEIR REQUIREMENTS AT | | | 561-822-1435. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-05-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-05-20 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-05-20 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2009-05-20 09:14:04 | MECHANICAL PROVISO: | | | | | | M1305.1.3 APPLIANCES IN ATTICS. ATTICS CONTAINING | | | APPLIANCES REQUIRING ACCESS SHALL BE PROVIDED WITH AN | | | OPENING AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO | | | ALLOW REMOVAL OF THE LARGEST APPLIANCE. THE PASSAGEWAY | | | SHALL NOT BE LESS THAN 30 INCHES (762 MM) HIGH AND 22 | | | INCHES (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) | | | IN LENGTH MEASURED ALONG THE CENTERLINE OF THE | | | PASSAGEWAY FROM THE ATTIC ACCESS OPENING TO THE | | | APPLIANCE'S SERVICE PANEL. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING NOT LESS THAN 24 INCHES (610 | | | MM) WIDE. A LEVEL SERVICE SPACE NOT LESS THAN 30 INCHES | | | (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL BE | | | PRESENT AT THE FRONT OR SERVICE SIDE OF THE APPLIANCE. | | | THE CLEAR ACCESS OPENING DIMENSIONS SHALL BE A MINIMUM | | | OF 20 INCHES BY 30 INCHES (508 MM BY 762 MM), WHERE | | | SUCH DIMENSIONS ARE LARGE ENOUGH TO ALLOW REMOVAL OF | | | THE LARGEST APPLIANCE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-04-08 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-04-08 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2009-04-08 09:08:40 | 2007 FBC | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO (2) COPIES OF ENERGY CALCULATIONS AND | | | MANUAL J CALCULATIONS AS REQUIRED AS REQUIRED BY 2007 | | | FBC R N1100. | | | | | | 2) REVISE PLANS TO COMPLY WITH 2007 FBC R M1602.4 | | | BALANCED RETURN AIR. | | | | | | 3) UPDATE REFERENCES TO FMC CODE SECTIONS TO THE 2007 | | | FMC AS SOME HAVE BEEN CHANGED. SEE REDLINED PLAN. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-04-07 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-04-07 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2009-04-07 07:39:43 | FIXTURE CHANGEOUT ONLY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-11-05 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2009-11-05 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2009-11-05 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2009-11-05 17:56:22 | PROVISO: | | | SEC. 94-305. SETBACKS. | | | | | | (4) MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN FOUR FEET INTO A SETBACK. WINDOW | | | AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN 18 | | | INCHES INTO A REQUIRED SIDE SETBACK. | | | | | | AMY F. STELLY | | | PLANNING AND ZONING | | | 561.822-1442 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-05-29 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-05-29 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-05-27 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2009-05-29 08:39:59 | PASSED WITH PROVISOS: | | | 1. THE A/C EQUIPMENT SHALL BE AT LEAST 4 FEET FROM WEST | | | PROPERTY LINE. | | | 2. THE LANDSCAPE/IRRIGATION PLANS SHALL BE APPROVED | | | PRIOR TO FINAL C.O. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-04-15 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-04-15 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-04-14 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2009-04-15 12:56:41 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK | | | EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS | | | "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | 3. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | | | 4. INDICATE SETBACK DIMENSIONS FROM PROPOSED OR | | | RELOCATED A/C EQUIPMENT TO ALL PROPERTY LINES. PURSUANT | | | THE ZLDR, SECTION 94-305(B)(4): MECHANICAL EQUIPMENT | | | MAY NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED | | | SETBACK. | | | | | | PURSUANT TO THE ZLDR, SECTION 94-74: SINGLE FAMILY HIGH | | | DENSITY (SF14) RESIDENTIAL DISTRICT - MINIMUM SETBACKS | | | FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | | | A. FRONT: 25 FEET; | | | | | | B. CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60 | | | FEET WIDE; | | | | | | C. REAR: 15 FEET OR TEN PERCENT OF DEPTH, WHICHEVER IS | | | LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|