Plan Review Details - Permit 09030554
Plan Review Stops For Permit 09030554
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-04-13 Cont ID  
Sent By jwitmer Date 2009-04-13 Time 15:10 Rev Time 0.78
Received By jwitmer Date 2009-04-13 Time 15:10 Sent To  
Notes
2009-04-13 15:15:05BUILDING PLAN REVIEW
 PERMIT: 09030554
 ADD: 956 BEAR ISLAND CIRCLE
 CONT: RHODES REMODELING LLC
 TEL: (561)578-9223
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING REVIEW
 ACTION: PROVISO
  
 R308.4 HAZARDOUS LOCATIONS EXCEPTION# 10. GLASS BLOCK
 PANELS COMPLYING WITH SECTION R610.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL
 OFFICIALS REGARDING CITY BUSINESS ARE PUBLIC RECORD,
 AVAILABLE TO THE PUBLIC UPON REQUEST. YOUR E-MAIL
 COMMUNICATIONS ARE THEREFORE SUBJECT TO PUBLIC
 DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-04-10 Cont ID  
Sent By dpalmer Date 2009-04-10 Time 13:25 Rev Time 0.00
Received By dpalmer Date 2009-04-10 Time 13:25 Sent To  
Notes
2009-04-10 13:25:48REDLINED GFI'S TO BE VERIFIED. 210.52D, 210.11C3,
 210.8A1, MUST BE 20AMP #12
  
 HOUSE SMOKE ALARMS EXISTING MEETING CURRENT NFPA-72
 VERIFY IN FIELD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-13 Cont ID  
Sent By jwitmer Date 2009-04-13 Time 16:06 Rev Time 0.00
Received By jwitmer Date 2009-03-30 Time 16:47 Sent To  
Notes
2009-03-30 16:47:16TO "R6"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-04-13 Cont ID  
Sent By jwitmer Date 2009-04-13 Time 15:54 Rev Time 0.77
Received By jwitmer Date 2009-04-13 Time 15:54 Sent To PC
Notes
2009-04-13 15:59:14BUILDING PLAN REVIEW
 PERMIT: 09030554
 ADD: 956 BEAR ISLAND CIRCLE
 CONT: RHODES REMODELING LLC
 TEL: (561)578-9223
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 MECHANICAL REVIEW
 ACTION: PROVISO
  
 MECHANICAL PERMIT REQUIRED! M1507.2 RECIRCULATION OF
 AIR. EXHAUST FANS FROM BATHROOMS AND TOILET ROOMS
 SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO
 ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY
 TO
 THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET
 ROOMS SHALL NOT DISCHARGE IN TO THE ATTIC, CRAWL SPACE
 OR OTHER AREAS INSIDE THE BUILDING.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL
 OFFICIALS REGARDING CITY BUSINESS ARE PUBLIC RECORD,
 AVAILABLE TO THE PUBLIC UPON REQUEST. YOUR E-MAIL
 COMMUNICATIONS ARE THEREFORE SUBJECT TO PUBLIC
 DISCLOSURE.

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-04-08 Cont ID  
Sent By kstevens Date 2009-04-08 Time 16:23 Rev Time 0.00
Received By jwitmer Date 2009-04-13 Time 15:10 Sent To  
Notes
***NONE***