Plan Review Details - Permit 09030201
Plan Review Stops For Permit 09030201
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2010-12-08 Cont ID  
Sent By jgomez Date 2010-12-08 Time 08:45 Rev Time 0.00
Received By jgomez Date 2010-12-08 Time 08:45 Sent To  
Notes
2010-12-08 08:50:50MET WITH OWNER TO GO OVER PRODUCT APPROVALS:
  
 1- NEED 2 COPIES OF PRODUCT APPROVALS. ONLY ONE
 SUBMITTED.
  
 2- NEED THE ENGINEER OF RECORD TO REVIEW AND APPROVE IN
 WRITING ALL PRODUCT APPROVALS. SEC. 106.3.3 CITY
 AMENDMENTS TO FBC.
  
 3- SOME PRODUCT APPROVALS ARE EXPIRED. NEED CURRENT
 ONES. TOLD OWNER OF EXPIRED ONES.
  
 4- TOLD OWNER TO PROVIDE THE REST OF THE ITEMS
 REQUESTED ON THE PROVISO.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-20 Cont ID  
Sent By jgomez Date 2009-07-20 Time 15:46 Rev Time 0.00
Received By jgomez Date 2009-07-20 Time 15:46 Sent To P
Notes
2009-07-20 15:57:44BUILDING REVIEW APPROVED WITH PROVISO: (PROVIDE
 INFORMATION FOR REVIEW PRIOR TO INSPECTION):
  
 1- REVISE GABLE END DETAIL TO COMPLY WITH SECTIONS
 R609.4 THRU R609.4.4 OF 2007 FL. RESIDENTIAL CODE.
 2- PROVIDE 2 COPIES OF PRODUCT APPROVALS (RULE 9B-72)
 FOR: A) SHINGLES. B) SINGLE HUNG WINDOWS. C) ALL
 EXTERIOR DOORS. D) ALL SIMPSON STRUCTURAL CONNECTORS.
 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS. SEC. 106.3.3 CITY AMENDMENTS TO
 FBC.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-15 Cont ID  
Sent By btrobaug Date 2009-04-15 Time 08:49 Rev Time 0.00
Received By jgomez Date 2009-04-15 Time 09:39 Sent To  
Notes
2009-04-15 10:19:47RESIDENTIAL (R3) NEW SINGLE FAMILY RESIDENCE, BUILDING
 REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE.
  
 1- SHEET 3:
 A) REVISE ROOF SHEATHING SPECIFICATIONS. NEED TO REVISE
 TYPE OF NAIL AND NAIL SPACING. NEED MIN. 8D RING SHANK
 NAILS AND NAIL SPACING TO BE MIN. 4"O.C. FOR ZONE 3.
 SEE SEC. R803.2.3.1 AND FIGURE R803.2.3.1 OF 2007
 FLORIDA RESIDENTIAL CODE. NOTE THAT GABLE ENDS ARE ZONE
 3 FOR THE FIRST 5'. REVISE AND IDENTIFY ROOF ZONES AS
 REQUIRED.
  
 B) GABLE END DETAIL NEEDS TO COMPLY WITH THE
 REQUIREMENTS OF SECTIONS R609.4 THRU R609.4.4 OF 2007
 FLORIDA RESIDENTIAL CODE. SEE REFERENCED FIGURES AND
 REVISE AS REQUIRED.
  
 C) SPECIFY FIREBLOCKING MATERIAL AND LOCATION ON GABLE
 END DETAIL AS REQUIRED BY SEC. R602.1.2 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 D) SPECIFY 2 LAYERS OF VAPOR BARRIER WHEN APPLYING
 STUCCO AS REQUIRED BY SEC. R703.6.3 OF 2007 FLORIDA
 RESIDENTIAL CODE. REVISE NOTE #2 AS REQUIRED.
  
 2- SHEET 4:
  
 A) PROVIDE MANUFACTURER CUT SHEETS FOR WINDOW #4 IN
 MASTER BEDROOM TO VERIFY COMPLIANCE WITH MIN. SIZE
 REQUIRED BY SEC. R310 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 B) REVISE SIZE OF DOOR BUCK AS REQUIRED TO COMPLY WITH
 SEC. R613.6. SIZE OF BUCK NEED TO PROVIDE FULL SUPPORT
 TO THE DOOR FRAME. SEE SIZE OF DOOR FRAME ON PRODUCT
 APPROVAL AND REVISE AS REQUIRED.
  
 C) DESIGN PARAMETERS: SPECIFY ALL LOADS AS REQUIRED BY
 SEC. R301.1 AND TABLE R301.5 OF 2004 FLORIDA
 RESIDENTIAL CODE. NEED TO SPECIFY THE ATTIC LIVE LOAD
 AS REQUIRED BY TABLE R301.5.
  
 D) UPDATE THE CODE EDITION SPECIFIED ON WIND LOADS.
 NEED TO SPECIFY 2007 FLORIDA RESIDENTIAL CODE, NOT
 2004.
  
 E) COMPONENTS AND CLADDING WIND PRESSURES SHOWN ON WIND
 LOADS DON'T MATCH COMPONENTS AND CLADDING WIND
 PRESSURES SPECIFIED ON DOOR AND WINDOW SCHEDULE. REVISE
 AS REQUIRED.
  
 F) SPECIFY SAFETY GLASS ON FOR WINDOW #5 ON MASTER
 BATHROOM AS REQUIRED BY SEC. R308.4 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 3- SURVEY TO HAVE ORIGINAL SIGNATURE (NOT RUBBER STAMP)
 AS REQUIRED BY CHAPTER 472 FLORIDA STATUTE.
  
 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL SITE PREPARATION, LABOR
 AND MATERIALS, PROFESSIONAL FEES AS REQUIRED BY SEC.
 108.3 CITY AMENDMENTS TO FBC. OWES $3066.98 FOR UPDATED
 VALUATION AND RADON FEES.
  
 5- CLARIFY TYPE OF WINDOW TO BE USED IN MASTER
 BATHROOM. WINDOW SCHEDULE CALLS FOR SINGLE HUNG WINDOW,
 WHILE EXTERIOR ELEVATION SHOWS FIXED WINDOW. REVISE AS
 REQUIRED. IF USING FIXED WINDOW, THEN PROVIDE
 CORRESPONDING PRODUCT APPROVAL.
  
 6- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) ROOF SHINGLES. PRODUCT APPROVAL FL10674-R1 SUBMITTED
 IS MISSING THE DRAWINGS THAT WERE SUBMITTED TO GET THE
 PRODUCT APPROVAL.
  
 B) SINGLE HUNG/DOUBLE HUNG WINDOWS. PRODUCT APPROVAL
 FL5043 SUBMITTED IS FOR 2004 CODE VERSION. CURRENT CODE
 IN EFFECT IS THE 2007 CODE VERSION.
 ALSO, PROVIDE DRAWINGS THAT WERE SUBMITTED FOR APPROVAL
 ALONG WITH THE TECHNICAL INFORMATION SHOWING THE DESIGN
 PRESSURES FOR SELECTED WINDOWS TO VERIFY COMPLIANCE
 WITH ENGINEER'S CALCULATED DESIGN PRESSURES.
  
 C) EXTERIOR SWING DOORS. PRODUCT APPROVAL FL7551
 SUBMITTED IS FOR 2004 CODE VERSION. NEED 2007 CODE
 VERSION.
 ALSO, PROVIDE INFORMATION SHOWING THE DESIGN PRESSURES
 FOR SELECTED DOORS.
  
 D) SLIDING GLASS DOORS. PRODUCT APPROVAL FL1824-R0
 SUBMITTED IS FOR 2001 CODE VERSION. NEED TO PROVIDE
 2007 CODE VERSION.
 ALSO, PROVIDE DRAWINGS SHOWING THE DESIGN PRESSURES FOR
 SELECTED DOORS.
  
 E) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SELECTED ANCHOR. THIS
 APPLIES TO STRUCTURAL CONNECTORS ONLY. COMPLETE PRODUCT
 APPROVAL REPORT IS REQUIRED FOR ALL OTHER PRODUCT
 APPROVALS.
  
 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 8- ENERGY CALCULATIONS:
 A) PAGE 1 OF 5 STATES THAT THIS IS NOT A WORST CASE
 SCENARIO. ORIENTATION OF WINDOWS SHOWN ON PAGE 3 OF 5
 DOESN'T MATCH ORIENTATION OF BUILDING. SEE SURVEY AND
 REVISE AS REQUIRED.
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER NAME AND PERMIT OFFICE.
  
 C) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 D) PROVIDE INFORMATION FOR WINDOWS SHOWING COMPLIANCE
 WITH THE U-FACTOR AND SHGC FACTOR SHOWN ON ITEM #7.
 NOTE: THIS IS REQUIRED WHEN CALCULATIONS ARE DONE USING
 SPECIFIC FACTORS AND NOT THE DEFAULT FACTOR OF THE
 PROGRAM USED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-08 Cont ID  
Sent By btrobaug Date 2009-07-08 Time 08:33 Rev Time 0.00
Received By btrobaug Date 2009-07-07 Time 15:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-03-26 Cont ID  
Sent By btrobaug Date 2009-03-26 Time 08:43 Rev Time 0.00
Received By btrobaug Date 2009-03-25 Time 15:02 Sent To M
Notes
2009-03-26 08:43:31 
  
 APPLICATION #09030201 ELECTRICAL PLAN REVIEW
 5514 WESTERN AVENUE 3/25/09
 WEST PALM BEACH, FL.
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.2. FBC.
  
 2} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN,
 METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT
 COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED.
  
 3} CIRCUIT NUMBER 6,8 FOR THE AHU OCP IS INADEQUATE PER
 424.3(B), NEC (125%).
  
 4} PER 210.8(A) (6) GFI PROTECTION IS REQUIRED IN
 KITCHENS ??? WHERE THE RECEPTACLES ARE INSTALLED TO
 SERVE THE COUNTERTOP SURFACES, THIS INCLUDES THE
 COUNTERTOP SURFACES AT THE RANGE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-08-31 Cont ID  
Sent By lmartine Date 2010-08-31 Time 14:50 Rev Time 0.00
Received By lmartine Date 2010-08-31 Time 14:50 Sent To  
Notes
2010-08-31 14:50:54GAVE TO JULIO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2009-06-25 Time   Rev Time 0.00
Received By jwitmer Date 2009-06-25 Time 11:29 Sent To  
Notes
2009-06-25 11:30:41INCOMING TO R-2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-27 Cont ID  
Sent By rmcdouga Date 2009-04-27 Time 14:41 Rev Time 0.00
Received By rmcdouga Date 2009-03-11 Time 10:45 Sent To  
Notes
2009-03-11 10:46:10TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2009-07-23 Cont ID  
Sent By rkussner Date 2009-07-23 Time 16:32 Rev Time 0.00
Received By rkussner Date 2009-07-23 Time 16:32 Sent To  
Notes
2009-07-23 16:35:40***LANDSCAPE REVIEW PASSED WITH 'PROVISO'***
  
 A COMPLETE LANDSCAPE PLAN AND CALCULATIONS THAT MEET
 ALL OF THE REQUIREMENTS SET FORTH IN ARTICLE XIV OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS SHALL BE
 SUBMITTED AND APPROVED PRIOR TO C/O.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-07-06 Cont ID  
Sent By rkussner Date 2009-07-06 Time 14:49 Rev Time 0.00
Received By rkussner Date 2009-07-06 Time 14:49 Sent To  
Notes
2009-07-06 15:07:10***LANDSCAPE REVIEW FAILED***
  
 1, PURSUANT TO SECTION 94-442 (G), PLEASE PROVIDE THE
 REQUIRED XERISCAPE TABULATION.
  
 2. PURSUANT TO SECTION 94-442(D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED.
  
 3. PURSUANT TO SECTION 94-445(4)(G)(3), AUTOMATIC
 IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED
 LANDSCAPE AREAS FOR ALL PROPERTIES, INCLUDING THE
 RIGHTS-OF-WAY. AN IRRIGATION PERMIT IS REQUIRED.
  
 4. SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST
 OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO
 UNIT COST.
  
 5. NOTES REGARDING DEPTH OF MULCH, IRRIGATION
 REQUIREMENTS AND THE PLANT GRADING SYSTEM REQUIREMENTS
 SHALL APPEAR ON THE PLAN.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2009-07-20 Cont ID  
Sent By jgomez Date 2009-07-20 Time 16:11 Rev Time 0.00
Received By jgomez Date 2009-07-20 Time 16:10 Sent To  
Notes
2009-07-20 16:11:49TALKED TO THE OWNER TO PROVIDE COMPLETE PLANS AND
 INFORMATION FOR MECHANICAL WORK UNDER A SEPARATE
 PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2009-07-14 Cont ID  
Sent By rregueir Date 2009-07-14 Time 16:13 Rev Time 0.00
Received By rregueir Date 2009-07-14 Time 16:13 Sent To  
Notes
2009-07-14 16:13:26A MECHANICAL PERMIT HAS BEEN APPLIED FOR. NO PLANS 2ND
 TIME. PROVIDE PLANS WITH DETAIL OF SPECIFIC MECHANICAL
 SCOPE OF WORK OR APPLY FOR SEPARATE PERMIT WITH
 SEPARATE PLANS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-04-03 Cont ID  
Sent By hmoser Date 2009-04-03 Time 12:47 Rev Time 0.00
Received By hmoser Date 2009-04-03 Time 12:47 Sent To P
Notes
2009-04-03 12:47:55NO PLANS

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-07-21 Cont ID  
Sent By rmcdouga Date 2009-07-21 Time 11:56 Rev Time 0.00
Received By rmcdouga Date 2009-07-21 Time 11:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-04-27 Cont ID  
Sent By btrobaug Date 2009-04-27 Time 14:31 Rev Time 0.00
Received By rmcdouga Date 2009-04-27 Time 14:31 Sent To  
Notes
2009-04-27 14:40:542007 FBC
 NSFR
 DENIED BY PLUMBING
  
 1) SUBMIT TWO COPIES OF A SANITARY ISOMETRIC RISER
 DIAGRAM. FBC 106.3.5.4* CITY AMENDMENTS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2009-07-27 Cont ID  
Sent By mcruz Date 2009-07-07 Time 11:47 Rev Time 0.00
Received By mcruz Date 2009-07-06 Time 12:19 Sent To  
Notes
2009-07-07 11:47:28PASSED WITH PROVISOS:
 THE LANDSCAPE/IRRIGATION PLANS SHALL BE APPROVED PRIOR
 TO FINAL C.O.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-03-18 Cont ID  
Sent By mcruz Date 2009-03-18 Time 19:56 Rev Time 0.00
Received By mcruz Date 2009-03-18 Time 19:45 Sent To I
Notes
2009-03-18 19:55:38PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE A LANDSCAPE PLAN IN COMPLIANCE WITH THE
 FOLLOWING PROVISIONS: PURSUANT TO THE CITY OF WEST PALM
 BEACH ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR),
 SECTION 94-442(2)(A): GENERAL LANDSCAPING STANDARDS FOR
 SINGLE-FAMILY DWELLING UNITS SHALL BE AS FALLOWS:
  
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
  
 YOU WILL NEED TO PROVIDE THE CALCULATIONS OF YOUR TOTAL
 OPEN SPACE. TO CALCULATE YOUR OPEN SPACE AREA, YOU WILL
 NEED TO FIRST FIGURE OUT YOUR TOTAL LOT AREA (LENGTH X
 WIDTH OF THE LOT) AND SUBTRACT THE SQUARE FOOTAGE OF
 THE BUILDING'S FOOTPRINT. THIS WILL GIVE YOU YOUR OPEN
 SPACE CALCULATION, WHICH YOU CAN THEN DIVIDE BY 1,200
 TO GET THE NUMBER OF REQUIRED SHADE TREES, AND DIVIDE
 BY 500 TO GET YOUR TOTAL NUMBER OF REQUIRED SHRUBS.
 PLEASE NOTE THE FOLLOWING:
 -- IF YOUR EXISTING LANDSCAPING FALLS SHORT OF THESE
 CALCULATED NUMBERS, ADDITIONAL TREES/SHRUBS WILL NEED
 TO BE INSTALLED. **NOTE: PALM TREES DO NOT COUNT AS
 SHADE TREES.
 -- SHOW ON SITE PLAN OR SURVEY: THE LOCATION, TYPE, AND
 SIZE OF THE REQUIRED LANDSCAPING.
 -- SHRUBS NEED TO BE A MINIMUM TWO (2) GALLON CONTAINER
 SIZE. TREES NEED TO BE A MINIMUM OF 8 FEET IN HEIGHT
 WITH A CLEAR TRUNK SPACE OF AT LEASE FIVE (5) FEET.
 -- PURSUANT TO THE ZLDR, SECTION 94-445(4)(G)(3), ALL
 YARD/LANDSCAPE AREAS ARE REQUIRED TO BE IRRIGATED.
  
 3. HAS THE EXISTING POOL EQUIMENT BEEN RELOCATED AS A
 RESULT OF THIS PROJECT? IF YES, PLEASE INDICATE THE
 SETBACK DIMENSIONS FROM THE POOL EQUIPMENT TO ALL
 ADJACENT PROPERTY LINES. NOTE: PURSUANT TO THE ZLDR,
 SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO AN REQUIRED SETBACK.
  
 4. DRIVEWAY SHALL BE SUBMITTED UNDER SEPERATE PERMIT.
 NOTE: PURSUANT TO THE ZLDR, SECTION 94-482: REQUIRED
 OFF-STREET PARKING SPACES FOR LESS THAN FOUR
 RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE
 PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN
 THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH,
 NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION
 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO
 PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE.
  
 PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE
 FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT
 BUILDING FACADE).
  
 IS THE DRIVEWAY APPROACH BEING WIDENED? IF YES, A
 RIGHT-OF-WAY PERMIT WILL NEED TO BE ACQUIRED FROM THE
 CITY'S ENGINEERING DEPARTMENT (561.494.1040), FOR THE
 PROPOSED WIDENING OF THE APPROACH EXTENSION.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  