Plan Review Details - Permit 09030109
Plan Review Stops For Permit 09030109
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-05-19 Cont ID  
Sent By shill Date 2009-05-19 Time 08:54 Rev Time 0.00
Received By shill Date 2009-05-19 Time 08:54 Sent To Z
Notes
2009-05-19 08:55:33PASSED W/PROVISO/REDLINE
 PER ARCHITECT
  
 1. DOOR 3 - REVERSE SWING TO MAINTAIN MANEUVERING
 CLEARANCE FBC FIG 11-25
  
 2. HANDRAIL EXTENSIONS REQUIRED FOR RAMP 18" TOP AND
 BOTTOM FBC 11-4.8.5.
  
 3. VISUAL ALARM REQUIRED IN BATHROOM FBC 11.
  
 PLANS REMOVED FROM BOB BOARD, ROUTED TO JR (THRU MC)
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-05-08 Cont ID  
Sent By shill Date 2009-05-08 Time 14:17 Rev Time 0.00
Received By shill Date 2009-05-08 Time 14:17 Sent To  
Notes
2009-05-08 14:36:20****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 COMMENTS FROM FIRST REVIEW NOT ADDRESSED:
  
 1. (PREVIOUSLY #6, FIRST REVIEW) THE APPLICATION DOES
 NOT GIVE CLEAR DESCRIPTOIN OF THE INTENDED WORK OF THE
 AREA. BOTH THE APPLICATION AND THE DRAWINGS SHALL
 CLEARLY SHOW IN DETAIL THE LOCATION AND AREA OF THE
 PROPOSED CHANGES. PROVIDE A WALL LEGEND CLEARLY
 INDICATING THE NEW WALLS AND EXISTING WALL WITH
 DESCRIPTION OF ALL MATERIALS. THE DRAWINGS SHALL ALSO
 STATE THE USE OF EACH ROOM OF THE SPACE.
  
 2ND REVIEW, NO WALL LEGEND PROVIDED. SOME WALLS ARE
 SHOWN IN GREY, SOME IN BLACK, AND SOME ARE DOUBLE
 BLACKLINE. WHICH ARE NEW, EXISTING? SCOPE IS NOT CLEAR;
 PLEASE PROVIDE WALL LEGEND.
  
 2. THE NEW CLOSET DOOR (DOOR 2) INTERFERES WITH THE
 DOOR SWING OF THE BATHROOM DOOR FBC1005, AND THE
 PROPOSED NEW (CLOSET) WALL OBSTRUCTS THE REQUIRED
 MANEUVERING CLEARANCE, PULL SIDE, FBC11 FIGURE 25. IT
 APPEARS THAT REVERSING THE BATHROOM DOOR MAY RESOLVE
 THE ISSUE, BUT ANY CODE COMPLIANT OPTION IS ACCEPTABLE.
  
 3. THE RAMP HANDRAILS LACK THE REQUIRED EXTENSION,
 FBC11-4.8.5(2).
  
 4. FBC11-4.28.2, VISUAL ALARM REQUIRED IN BATHROOM.
 (NEW COMMENT, CAN BE PROVISO/REDLINE.)
  
 5. PLEASE NOTE THAT IT IS POSSIBLE THAT THIS REVIEW CAN
 BE PASSED WITH PROVISO/REDLINE (REVISION REQUIRED),
 PLEASE CONTACT ME IF THIS APPLICATION PASSES ALL OTHER
 TRADES.
  
 6. PLEASE PROVIDE A COPY OF THE CONTRACT FOR THIS JOB.
 FBC*106.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-03-13 Cont ID  
Sent By mjacobs Date 2009-03-13 Time 16:27 Rev Time 0.00
Received By mjacobs Date 2009-03-13 Time 16:27 Sent To  
Notes
2009-03-13 16:27:07BUILDING PLAN REVIEW
 PERMIT: 09030109
 ADD: 1804 N. DIXIE HWY UNIT C
 CONT: HOLEMAN HOMES INC.
 TEL: (561)743-0687
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH THE 2009 SUPPLEMENTS. THE DESIGN UNDER
 WHICH THE PROJECT IS BASE SHALL BE STATED ON THE PLANS.
  
 4) 2007 FBC (EXISTING) 401.4 A DESIGN PROFESSIONAL OR
 AN OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 403, 404 AND 405 OF
 THIS CODE. THIS INFORMATION SHALL BE INDICATED ON THE
 PLANS.
  
 5) THE PLANS SHALL INDICATE THE TYPE OF CONSTRUCTION
 PER CHAPTER 6 AND TABLE 503, THE USE AND OCCUPANCY PER
 CHAPTER 3. THIS INFORMATION IS REQUIRED SO THAT ANY
 ADDITIONAL CONSTRUCTION IN ACCORDANCE WITH THE ORIGINAL
 BUILDING TYPE.
  
 6) THE APPLICATION DOES NOT GIVE CLEAR DESCRIPTION OF
 THE INTENDED WORK OF THE AREA. BOTH THE APPLICATION AND
 THE DRAWINGS SHALL CLEARLY SHOW IN DETAIL THE LOCATION
 AND AREA OF THE PROPOSED CHANGES. PROVIDE A WALL LEGEND
 CLEARLY INDICATING THE NEW WALLS AND THE EXISTING WALL
 WITH A DESCRIPTION OF ALL MATERIALS. THE DRAWINGS SHALL
 ALSO STATE THE USE OF EACH ROOM OF THE SPACE. THE PLANS
 SHOW A SECTION OF A MEZZANINE, PLEASE INDICATE CLEARLY
 THE LOCATION OF THE MEZZANINE ON THE DRAWINGS. THE
 DOCUMENTS SHALL CLEARLY SHOW THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED FBC 106.1.1
  
 7) SHEET 1.0A SHOWS A SECTION FOR A RAISED PLATFORM ON
 2 X 8 WITH ?? INCH PLYWOOD. THE PLATFORM SHALL BE
 CONSTRUCTED IN ACCORDANCE WITH FBC 2007 410.3 AND
 410.4. INDICATE THE USE OF THE PLATFORM ON THE
 DRAWINGS. SHOW THE ACCESSIBILITY ENTRANCE TO THE
 PLATFORM FBC 11-4.1.2 VERTICAL ACCESSIBILITY, SHALL BE
 PROVIDED TO ALL LEVELS ABOVE OR BELOW THE OCCUPIAABLE
 GRADE LEVEL. SHOW COMPLIANCE. HANDRAILS MAY BE REQUIRED
 WHEN ADDITIONAL INFORMATION SHOWN WITH THE HEIGHT AND
 USE OF THE PLATFORM.
  
 8) THERE ARE SOME SYMBOLS ON THE PLANS WITH NUMBERS
 INSIDE, IF THESE SYMBOLS ARE MAKING REFERENCE TO
 DETAILS PROVIDE THE DETAIL DRAWINGS.
  
 9) PROVIDE THE CONNECTION DETAIL OF THE 2 X 8 TO THE
 EXISTING FLOOR AND EXISTING WALLS WITH THE TYPES OF
 CONNECTION STRAPS; AND THE NAIL PATTERN FOR THE
 PLYWOOD. STATE THE TYPE OF WOOD TO BE USED AND THE TYPE
 OF EXISTING FLOOR. THE UNIFORM DISTRIBUTED LIVE LOAD
 SHALL BE GIVEN PER TABLE 1067.1, ALONG WITH THE LATERAL
 SUPPORT PER 2308.8.5 AND THE GRADE/ SPECIES AND NUMBER
 FOR THE TYPE OF WOOD USED FBC 2304.7.1.
  
 NOTE: ADDITIONAL NOTES MAY APPEAR ON SECOND REVIEW
 DEPENDING ON THE RESPONSE TO THE ABOVE NOTES.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 PHONE (561)805-6726
 FAX (561) 805-6676
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-05-08 Cont ID  
Sent By btrobaug Date 2009-05-08 Time 12:51 Rev Time 0.00
Received By btrobaug Date 2009-05-08 Time 12:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-03-17 Cont ID  
Sent By btrobaug Date 2009-03-17 Time 10:03 Rev Time 0.00
Received By btrobaug Date 2009-03-17 Time 09:08 Sent To  
Notes
2009-03-17 10:03:11 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2006, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} INDICATE CIRCUIT NUMBERS FOR DEVICES 106.3.5 FBC.
  
 2} 301.5 FBC EXISTING BUILDING CODE. THE DESIGN
 PROFESSIONAL OR OWNER MUST ELECT THE LEVEL OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF THE
 EXISTING BUILDING CODE. PLEASE DECLARE SAME ON THE
 PLAN.
  
 3} FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN
 THE FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE
 INDICATE THE CODE CYCLES UNDER WHICH THIS PLAN WAS
 DESIGNED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-05-11 Cont ID  
Sent By mawillia Date 2009-05-11 Time 14:38 Rev Time 0.00
Received By mawillia Date 2009-05-11 Time 13:48 Sent To  
Notes
2009-05-11 14:23:37*****APPROVED W/PROVISO****
  
 THE COMMENTS FORM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED AND/OR RED-LINED; PLAN SHEETS 1.0A AND
 2.0E WERE STAMPED, INITIALED, AND DATED.
  
 ATTENTION: IN THE EVENT THAT SHEET 1.0A IS TO BE
 REVIEWED AGAIN FOR CORRECTION(S) AND/OR REVISED, AMEND
 GENERAL NOTE #1 AS RED-LINED BY THIS WRITER
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-03-31 Cont ID  
Sent By mawillia Date 2009-03-31 Time 12:36 Rev Time 0.00
Received By mawillia Date 2009-03-31 Time 12:03 Sent To  
Notes
2009-03-31 12:36:40*****DENIED*****
  
  
 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2. FLORIDA FIRE PREVENTION CODE 2007 WHICH IS BASED
 UPON THE 2006 EDITION OF NFPA 101 AND THE 2006 EDITION
 OF NFPA 1 SHALL BE REFERENCED
  
 3. PLEASE INDICATE PERTINENT DATA / INFORMATION FOR
 THIS PROJECT SITE SUCH AS CONSTRUCTION TYPE, TYPE OF
 OCCUPANCY, BUILDING USE, OCCUPANT LOAD, LIFE SAFETY
 SYSTEMS, ETC.
  
 4. THE SUITE DESIGNATION SHALL BE INCLUDED WITH THE
 ADDRESS AS SHOWN IN THE TITLE BLOCK OF EACH SUBMITTED
 PLAN SHEET.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-05-01 Cont ID  
Sent By lmartine Date 2009-05-01 Time 16:47 Rev Time 0.00
Received By shill Date 2009-05-01 Time 16:46 Sent To  
Notes
2009-05-06 13:05:05TO BOB BOARD #19
  
2009-05-01 16:47:29 
  
 C-6

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-03-31 Cont ID  
Sent By mawillia Date 2009-03-31 Time 12:11 Rev Time 0.00
Received By mawillia Date 2009-03-06 Time 10:50 Sent To  
Notes
2009-03-06 10:50:21TO "BOB"#10

Review Stop Z ZONING
Rev No 2 Status F Date 2009-05-21 Cont ID  
Sent By jroach Date 2009-05-21 Time 16:51 Rev Time 0.00
Received By jroach Date 2009-05-21 Time 16:51 Sent To  
Notes
2009-05-21 16:51:33ZONING PLAN REVIEW
  
 PERMIT NO.: 09030109
 ADDRESS: 1804 NORTH DIXIE HIGHWAY
 CONTRACTOR/CONTACT: MICHAEL HOLEMAN
 TELEPHONE NO.: 561.743.0687
 SCOPE OF REVIEW: INTERIOR BUILD-OUT
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) PLEASE PROVIDE ADDITIONAL DETAIL REGARDING THE
 PROPOSED USE OF THE SUITE.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-03-16 Cont ID  
Sent By jroach Date 2009-03-16 Time 13:41 Rev Time 0.00
Received By jroach Date 2009-03-16 Time 13:41 Sent To  
Notes
2009-03-16 13:53:33ZONING PLAN REVIEW
  
 PERMIT NO.: 09030109
 ADDRESS: 1804 NORTH DIXIE HIGHWAY
 CONTRACTOR/CONTACT: MICHAEL HOLEMAN
 TELEPHONE NO.: 561.743.0687
 SCOPE OF REVIEW: INTERIOR BUILD-OUT
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) PLEASE PROVIDE ADDITIONAL DETAIL REGARDING THE
 PROPOSED USE OF THE SUITE.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.
  