Plan Review Details - Permit 09030108
Plan Review Stops For Permit 09030108
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-05-04 Cont ID  
Sent By dwise Date 2009-05-04 Time 17:45 Rev Time 0.00
Received By dwise Date 2009-05-04 Time 17:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-04-23 Cont ID  
Sent By dwise Date 2009-04-23 Time 08:46 Rev Time 0.00
Received By dwise Date 2009-04-23 Time 08:45 Sent To  
Notes
2009-04-23 08:46:44NEED REVISED PLAN FOR ZONING.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-05-04 Cont ID  
Sent By dwise Date 2009-05-04 Time 17:46 Rev Time 0.00
Received By dwise Date 2009-05-04 Time 17:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-03-25 Cont ID  
Sent By btrobaug Date 2009-03-25 Time 14:44 Rev Time 0.00
Received By btrobaug Date 2009-03-25 Time 14:34 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2009-04-23 Cont ID  
Sent By dwise Date 2009-04-23 Time 08:48 Rev Time 0.00
Received By dwise Date 2009-04-23 Time 08:48 Sent To  
Notes
2009-04-23 08:49:09SEPERATE GAS PERMIT AND PLANS REQUIRED FOR GAS SUPPLY
 TO 250K BTUH HEATER.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-03-18 Cont ID  
Sent By adarroug Date 2009-03-18 Time 09:22 Rev Time 0.00
Received By adarroug Date 2009-03-18 Time 09:22 Sent To E
Notes
2009-03-18 09:23:01TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-23 Cont ID  
Sent By dwise Date 2009-04-22 Time 08:45 Rev Time 0.00
Received By dwise Date 2009-03-11 Time 08:29 Sent To  
Notes
2009-03-11 08:29:23TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-05-04 Cont ID  
Sent By dwise Date 2009-05-04 Time 17:46 Rev Time 0.00
Received By dwise Date 2009-05-04 Time 17:46 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-04-23 Cont ID  
Sent By dwise Date 2009-04-23 Time 08:47 Rev Time 0.00
Received By dwise Date 2009-04-23 Time 08:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2009-05-13 Cont ID  
Sent By mcruz Date 2009-05-13 Time 12:06 Rev Time 0.00
Received By mcruz Date 2009-05-13 Time 12:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2009-03-18 Cont ID  
Sent By mcruz Date 2009-03-18 Time 08:29 Rev Time 0.00
Received By mcruz Date 2009-03-18 Time 08:16 Sent To I
Notes
2009-03-18 08:27:52PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. THE POOL LAYOUT AND DIMENSION PLAN INDICATES THAT
 THE POOL EQUIPMENT WILL BE LOCATED TO THE WEST SIDE OF
 THE POOL, PLEASE SHOW LOCATION OF POOL EQIPMENT ON THE
 SURVEY AND INDICATE THE SETBACK DIMENSIONS TO ALL
 ADJACENT PROPERTY LINES. PURSUANT TO THE CITY OF WEST
 PALM BEACH ZONING AND LAND DEVELOPMENT REGULATIONS
 (ZLDR), SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY
 NOT PROJECT MORE THAN 4 FEET INTO AN REQUIRED SETBACK.
  
 3. AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT
 FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT
 SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO
 THE MINIMUM STANDARDS PROVIDED BELOW:
  
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) THRU
 (D):
 .....
 B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT
 LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN
 ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH
 AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL
 BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
 D. IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT TO OR
 SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN AWAY
 FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved