Plan Review Details - Permit 09030047
Plan Review Stops For Permit 09030047
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-05-11 Cont ID  
Sent By dwise Date 2009-05-11 Time 07:24 Rev Time 0.00
Received By dwise Date 2009-05-11 Time 07:24 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-04-06 Cont ID  
Sent By shill Date 2009-04-06 Time 13:53 Rev Time 0.00
Received By shill Date 2009-04-06 Time 13:53 Sent To  
Notes
2009-04-06 14:03:22****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PLEASE REVISE GOVERNING CODE TO REFLECT CURRENT
 CODE, INCLUDING 2008 SUPPLEMENTS.
  
 2. PLEASE HAVE ENGINEER EXPLAIN RATIONALE FOR EXPOSURE
 B. IT APPEARS THAT THIS IS IN EXPOSURE C.
  
 3. PLEASE CLARIFY THE STATEMENT ON THE PLAN WHICH
 STATES THAT WEST OF THE TURNPIKE IS 130MPH. ALL OF THE
 CITY OF WEST PALM BEACH IS LOCATED IN THE 140MPH WIND
 ZONE, FBC R301.
  
 4. THERE ARE REFERENCES TO PALM BEACH COUNTY
 REQUIREMENTS AND BUILDING FORMS. THIS JOB IS LOCATED IN
 THE JURISDICTION OF THE CITY OF WEST PALM BEACH.
  
 5. PROVIDE EVIDENCE OF THE "EXISTING SHUTTERS," SUCH AS
 A PERMIT NUMBER. I WAS UNABLE TO LOCATE A PERMIT FOR
 THIS WORK. FBC R301.2.1.
  
 6. PROVIDE THE PRODUCT APPROVAL FOR THE DOOR, FAC9B72.
  
 7. A SET OF PLANS HAS BEEN RETAINED. WHEN RESUBMITTING,
 PLEASE SUBMIT TWO COMPLETE SETS OF PERMIT DOCUMENTS.
 NOTE THAT ONLY ONE SET OF PRODUCT APPROVALS WAS
 SUBMITTED; TWO REQUIRED.
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-03-09 Cont ID  
Sent By btrobaug Date 2009-03-09 Time 11:15 Rev Time 0.00
Received By btrobaug Date 2009-03-09 Time 10:59 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-05-05 Cont ID  
Sent By rregueir Date 2009-05-05 Time 08:34 Rev Time 0.00
Received By rregueir Date 2009-05-05 Time 08:34 Sent To B
Notes
2009-05-05 08:35:12ROUTED TO DOUG WISE DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-04-06 Cont ID  
Sent By shill Date 2009-04-06 Time 14:03 Rev Time 0.00
Received By shill Date 2009-03-04 Time 10:54 Sent To  
Notes
2009-03-04 10:55:58TO "SFR" "E"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2009-03-27 Cont ID  
Sent By hmoser Date 2009-03-27 Time 10:44 Rev Time 0.00
Received By hmoser Date 2009-03-27 Time 10:21 Sent To P
Notes
2009-03-27 10:59:40NO MECHANICAL WORK SHOWEN ON PLANS . IF AIR
 CONDITIONING WORK IS REQUIRED MUST SUBMIT PLANS FOR
 PERMIT .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-07-20 Cont ID  
Sent By kstevens Date 2009-07-20 Time 12:20 Rev Time 0.00
Received By kstevens Date 2009-07-20 Time 12:20 Sent To  
Notes
2009-07-20 12:21:06REVISION OK -- SHT RP-101.

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-03-31 Cont ID  
Sent By lwagner Date 2009-03-31 Time 10:07 Rev Time 0.00
Received By lwagner Date 2009-03-30 Time 10:53 Sent To B
Notes
2009-03-31 10:22:04PUT IN MISC. 3 CUBBY