Plan Review Details - Permit 09020611
Plan Review Stops For Permit 09020611
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2010-02-08 Cont ID  
Sent By shill Date 2010-02-08 Time 11:55 Rev Time 0.00
Received By shill Date 2010-02-08 Time 11:55 Sent To  
Notes
2010-02-08 11:58:57****PROVISO****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 DEMO OF KITCHEN, A/C UNIT (NOT CONNECTED), REMOVE
 BATHROOM, PATCH EXTERIOR STUCCO
 PROVISO - DETAIL FOR STUCCO REPAIR SUBJECT TO
 INSPECTOR'S DISCRETION
  
 SEPARATE PLANS AND PERMITS REQUIRED FOR SHUTTERS,
 WINDOWS, ELECTRIC, PLUMBING
  
 (SEE BUILDING COMMENTS FOR WINDOW AND SHUTTER PERMIT
 REQUIREMENTS)
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2010-02-08 Cont ID  
Sent By shill Date 2010-02-08 Time 11:44 Rev Time 0.00
Received By shill Date 2010-02-08 Time 11:44 Sent To  
Notes
2010-02-08 11:55:22****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE PROVIDE COMPLETE, LEGIBLE PRODUCT APPROVALS.
  
 2ND REVIEW, PRODUCT APPROVALS NOT LEGIBLE. FLORIDA
 STATE OR LOCAL PRODUCT APPROVAL REQUIRED. EASTERN METAL
 SUPPLY HAS 4 DIFFERENT STORM PANEL PRODUCT APPROVALS,
 AND I WAS UNABLE TO FIND THE EVALUATION REPORT
 SUBMITTED. THE CURRENT APPROVAL FOR .040" IS 2.25"
 DEEP, SEE FL #11968.1. PLEASE PROVIDE TWO COMPLETE,
 COLLATED, LEGIBLE SETS OF PRODUCT APPROVALS.
  
 2. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2ND REVIEW, TAPCONS WERE SPECIFIED ON THE INSTALLATION
 SCHEDULE, CONFLICTS WITH DETAIL CIRCLED ON PRODUCT
 APPROVAL WHICH SPECIFIES WOOD SCREWS. PLEASE INDICATE
 DETAIL ON THE PRODUCT APPROVAL WHICH ALLOWS TAPCONS AS
 AN ALTERNATE.
  
 3. PROVIDE A FLOOR PLAN SHOWING PROPOSED SHUTTER
 LOCATIONS TO CORRELATE WITH THE INSTALLATION SCHEDULE.
  
 4 PROVIDE TWO COMPLETE COLLATED SETS FOR PERMIT
 ISSUANCE.
  
 2ND REVIEW, NOT ADDRESSED. LOOSE ILLEGIBLE SHEETS WERE
 SUBMITTED. THE PRODUCT APPROVAL IS TO BE LEGIBLE,
 COLLATED, AND COMPLETE. THE PRODUCT APPROVAL IS TO
 INCLUDE THE COVER SHEET FROM WWW.FLORIDABUILDING.ORG.
 SEE OTHER COMMENTS, I WAS UNABLE TO LOCATE THE FLORIDA
 STATE PRODUCT APPROVAL FOR THE DOCUMENTS SUBMITTED.
  
 5. THIS PERMIT WILL BE ISSUED AS DEMO AND STUCCO REPAIR
 ONLY. THE SCOPE WAS WRITTEN ON THE RESUB SHEET AND
 INCLUDES SHUTTERS AND WINDOWS. NO WINDOW PRODUCT
 APPROVALS WERE SUBMITTED AND THE FIRST SUBMITTAL DID
 NOT INCLUDE WINDOWS. FOR A WINDOW PERMIT, PRODUCT
 APPROVALS, A FLOOR PLAN INCLUDING ROOM DESIGNATIONS,
 WINDOW SIZES AND LOCATIONS IS REQUIRED. PLEASE SUBMIT
 FOR SHUTTERS AND WINDOWS ON A SEPARATE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-12-15 Cont ID  
Sent By shill Date 2009-12-15 Time 16:26 Rev Time 0.00
Received By shill Date 2009-12-15 Time 16:26 Sent To  
Notes
2009-12-15 16:29:31****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE PROVIDE COMPLETE, LEGIBLE PRODUCT APPROVALS.
  
 2. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 3. PROVIDE A FLOOR PLAN SHOWING PROPOSED SHUTTER
 LOCATIONS TO CORRELATE WITH THE INSTALLATION SCHEDULE.
  
 4 PROVIDE TWO COMPLETE COLLATED SETS FOR PERMIT
 ISSUANCE.
  
 5. PROVIDE A REASONABLE VALUE FOR THIS JOB.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-10-15 Cont ID  
Sent By kconrad Date 2009-10-15 Time 07:54 Rev Time 0.00
Received By kconrad Date 2009-10-15 Time 07:54 Sent To  
Notes
2009-10-15 08:01:34MET WITH JONATHAN (TREMBLAY BUILDERS). REQUIRE THE
 FOLLOWING:
  
 1) PRODUCT APPROVALS FOR WINDOWS AND SHUTTERS.
  
 2) REQUIRE ELECTRICAL PLAN/ELECTRICAL CERTIFICATION.
  
 3) REQUIRE THE REMOVAL OF THE HVAC SYSTEM, KITCHEN AND
 BATHROOM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-03-02 Cont ID  
Sent By kconrad Date 2009-03-02 Time 14:30 Rev Time 0.00
Received By kconrad Date 2009-03-02 Time 14:30 Sent To  
Notes
2009-03-02 14:32:07PREINSPECT PERFORMED BY BT. REQUIRE PLANS FOR
 ELECTRICAL AND SHUTTER ISTALLATION. PAY 4X FEE. DENIED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-02-02 Cont ID  
Sent By shill Date 2010-02-02 Time 08:25 Rev Time 0.00
Received By shill Date 2010-02-02 Time 08:25 Sent To  
Notes
2010-02-02 08:25:25TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-07 Cont ID  
Sent By jgomez Date 2009-12-07 Time 08:37 Rev Time 0.00
Received By jgomez Date 2009-12-07 Time 08:37 Sent To B
Notes
2009-12-07 08:38:39SENT TO MISC. BOX #1.