Plan Review Details - Permit 09020590
Plan Review Stops For Permit 09020590
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2010-04-20 Cont ID  
Sent By jgomez Date 2010-04-20 Time 16:52 Rev Time 0.00
Received By jgomez Date 2010-04-20 Time 16:37 Sent To  
Notes
2010-04-20 16:52:59SEE NOTES ON REVISION #10040323.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2009-11-18 Cont ID  
Sent By jgomez Date 2009-11-18 Time 09:59 Rev Time 0.00
Received By jgomez Date 2009-11-18 Time 09:59 Sent To PC
Notes
2009-11-18 10:00:07REVISED FLOOR FRAMING PLANS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2009-08-18 Cont ID  
Sent By shill Date 2009-08-18 Time 14:30 Rev Time 0.00
Received By shill Date 2009-08-18 Time 14:30 Sent To  
Notes
2009-08-18 14:30:26RAS117 CALCULATIONS AND NOA
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-08-05 Cont ID  
Sent By shill Date 2009-08-05 Time 14:42 Rev Time 0.00
Received By shill Date 2009-08-05 Time 14:42 Sent To  
Notes
2009-08-05 14:42:45ADDED TO SCOPE, DOORS & WINDOWS
 REMINDED CONTRACTOR ABOUT PROVISO ITEM
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-08-05 Cont ID  
Sent By shill Date 2009-08-05 Time 11:49 Rev Time 0.00
Received By shill Date 2009-08-05 Time 11:49 Sent To  
Notes
2009-08-05 11:51:04****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. PROVIDE AN UPDATED VALUE FOR INCREASED SCOPE OF
 WORK. FBC*106
  
 2. PROVIDE STATUS OF PROVISO ITEM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-05-15 Cont ID  
Sent By jgomez Date 2009-05-05 Time 16:55 Rev Time 0.00
Received By shill Date 2009-05-05 Time 16:55 Sent To  
Notes
2009-05-15 10:25:47CONFIRMED THAT EN CALCS SIGNED AND DATED (JG NOT IN
 OFFICE)
  
2009-05-05 16:59:24BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- A) REVISE RAS 117 CALCULATIONS FOR FLAT ROOF
 ASSEMBLY. SELECTED ASSEMBLY IS ON SHEET 6 OF 18, NOT
 16, OF 18. SELECTED ASSEMBLY IS AN INSULATED SYSTEM.
 B) REVISE FASTENER SPACING FOR ROOF ZONE 1. SEE NOA
 SUBMITTED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-03-31 Cont ID  
Sent By jgomez Date 2009-03-31 Time 17:04 Rev Time 0.00
Received By jgomez Date 2009-03-31 Time 17:04 Sent To PC
Notes
2009-03-31 17:12:50RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 1- A) ACCORDING TO SOIL TEST REPORT PROVIDED THE SOIL
 BEARING CAPACITY REQUIRED FOR THE PROPOSED ADDITION IS
 3,500PSF. SHEET S-7 OF STRUCTURAL DRAWINGS SUBMITTED
 SPECIFIED SOIL BEARING CAPACITY OF 2,500PSF. AND,
 EXISTING FOUNDATION PLAN SHEET S-1 SPECIFIES THAT
 FOOTING HAVE BEEN DESIGNED FOR 2,000PSF SOIL BEARING
 CAPACITY. ALL THIS INFORMATION NEEDS TO BE CLARIFIED,
 REVISED AND COORDINATED AS REQUIRED.
  
 B) SOIL TEST REPORT NEEDS TO HAVE ENGINEERS' ORIGINAL
 SIGNATURE AS REQUIRED BY SEC. 61G15-23.002 FLORIDA
 ADMINISTRATIVE CODE AND CHAPTER 471 FLORIDA STATUTE.
  
 2- OWES $5.88 FOR RADON FEES.
  
 3- DESIGNER TO SPECIFY HOW IS ROOF TILE GOING TO BE
 INSTALLED AS REQUIRED BY SEC. 106.1.1.2 CITY AMENDMENTS
 TO FBC 2004. IF USING ADHESIVE, THEN PROVIDE PRODUCT
 APPROVAL FOR IT. CHECK ROOF TILE PRODUCT APPROVAL FOR
 LISTED ADHESIVES.
  
 4- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) ROOF TILE TO BE INSTALLED. NONE SUBMITTED AT THIS
 TIME.
  
 B) FLAT ROOF ASSEMBLY TO BE USED. NOA 07-0111.03
 SUBMITTED WAS SUPERSEDED BY MIAMI-DADE COUNTY. SEE
 ATTACHED COPY FROM WEBSITE. NEED TO PROVIDE CURRENT
 PRODUCT APPROVAL. ALSO, PROVIDE RAS 117 CALCULATIONS
 FOR NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7. AND, CLEARLY
 IDENTIFY WHICH ANCHOR SHEET FASTENING OPTION IS GOING
 TO BE USED. OPTION ONE OR OPTION TWO.
 ***NOTE: COORDINATE INFORMATION WITH ITEM #6A BELOW.
  
 C) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE WHERE CONNECTOR IS SHOWN. NO NEED
 TO SUBMIT COMPLETE REPORT. THIS APPLIES TO STRUCTURAL
 CONNECTORS ONLY. OTHER PRODUCT APPROVALS REQUIRE
 COMPLETE REPORT.
  
 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 6- ENERGY CALCULATIONS:
 A) REVISE CEILING TYPE AND INSULATION ON ITEM #10A. NEW
 ADDITION HAS UNDER ATTIC AREA, NOT SINGLE ASSEMBLY.
 REVISE AS REQUIRED. ALSO, COORDINATE WITH INFORMATION
 SHOWN ON ARCHITECTURAL PLANS AND FLAT ROOF PRODUCT
 APPROVAL.
  
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 7- A) SPECIFY DOUBLE LAYER OF VAPOR BARRIER ON NEW WALL
 CONSTRUCTION AS REQUIRED BY SEC. R703.6.3 OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 B) SPECIFY STUCCO THICKNESS AS REQUIRED BY SEC.
 R703.6.4.3 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-03-09 Cont ID  
Sent By btrobaug Date 2009-03-09 Time 09:35 Rev Time 0.00
Received By btrobaug Date 2009-03-09 Time 09:16 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-11-18 Cont ID  
Sent By jgomez Date 2009-11-18 Time 08:14 Rev Time 0.00
Received By jgomez Date 2009-11-18 Time 08:14 Sent To  
Notes
2009-11-18 08:17:22THIS PLANS WERE DROPPED ON ON MY DESK ON 11/17/09 NOT
 11/5/09.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-11-05 Cont ID  
Sent By kstevens Date 2009-11-05 Time 10:17 Rev Time 0.00
Received By shill Date 2009-11-05 Time 10:17 Sent To  
Notes
2009-11-17 11:00:32SENT TO JG
  
2009-11-05 10:17:32SENT TO SHILL.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-09-29 Cont ID  
Sent By shill Date 2009-09-29 Time 10:26 Rev Time  
Received By shill Date 2009-09-29 Time 10:25 Sent To  
Notes
2009-09-29 10:26:29ROOF PERMIT 09090566 ROUTED TO SMH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-07-30 Cont ID  
Sent By jwitmer Date 2009-07-30 Time 08:14 Rev Time 0.00
Received By jwitmer Date 2009-07-30 Time 08:13 Sent To  
Notes
2009-07-30 08:14:53TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-04-28 Cont ID  
Sent By dpalmer Date 2009-04-28 Time 16:14 Rev Time 0.00
Received By dpalmer Date 2009-04-28 Time 16:14 Sent To  
Notes
2009-04-28 16:14:17R-24

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-03-31 Cont ID  
Sent By jgomez Date 2009-03-31 Time 17:12 Rev Time 0.00
Received By jgomez Date 2009-03-02 Time 10:29 Sent To  
Notes
2009-03-02 10:30:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-04-20 Cont ID  
Sent By jgomez Date 2010-04-20 Time 16:35 Rev Time 0.00
Received By jgomez Date 2010-04-20 Time 16:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-03-27 Cont ID  
Sent By hmoser Date 2009-03-27 Time 10:02 Rev Time 0.00
Received By hmoser Date 2009-03-27 Time 09:51 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2009-03-27 Cont ID  
Sent By kstevens Date 2009-03-27 Time 16:56 Rev Time 0.00
Received By kstevens Date 2009-03-27 Time 16:56 Sent To B
Notes
2009-03-27 16:57:00NO PLUMBING PLANS SUBMITTED OR PLUMBING WORK SHOWN.

Review Stop Z ZONING
Rev No 2 Status P Date 2009-05-14 Cont ID  
Sent By mcruz Date 2009-05-14 Time 11:03 Rev Time 0.00
Received By mcruz Date 2009-05-14 Time 10:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2009-03-06 Cont ID  
Sent By mcruz Date 2009-03-06 Time 13:25 Rev Time 0.00
Received By mcruz Date 2009-03-06 Time 12:35 Sent To E
Notes
2009-03-06 13:25:44PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PLEASE SUBMIT A WRITTEN APPROVAL FROM THE BEAR LAKES
 ESTATE NORTH ARCHITECTURAL REVIEW BOARD (A.R.B.).
  
 PURSUANT TO THE BEAR LAKES ESTATE NORTH DECLARATION OF
 COVENANTS AND RESTRICTIONS, SECTION VII, ARCHITECTURAL
 CONTROLS, SUBSECTION P - IMPROVEMENTS AND ADDITIONS.
 EACH IMPROVEMENT OR ADDITION TO A RESIDENCE MUST
 CONFORM IN ARCHITECTURAL STYLE, AND TO EXTERIOR
 CONSTRUCTION MATERIALS, USED IN THE PRINCIPAL RESIDENCE
 ON THE LOT ANF IS SUBJECT TO THE REVIEW AND APPROVAL OF
 THE A.R.B. (SEE ATTACHED COPY)
  
 3. INDICATE OVERHANG DIMENSIONS OF THE PROPOSED
 ADDITION. PURSUANT TO THE CITY OF WEST PALM BEACH
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-305(B): OVERHANGS SHALL NOT PROJECT MORE THAN THREE
 (3) FEET INTO A REQUIRED SETBACK. SETBACK DIMENSIONS
 ARE SHOWN ON THE ATTACHED BEAR LAKES ESTATE NORTH
 DECLARATION OF COVENANTS AND RESTRICTIONS, SECTION VI,
 SUBSECTION C.1-5.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy