| 2009-02-19 12:04:47 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. SEE OPENING 8. CONNECTION TYPE A AND I REQUIRE A |
| | CONCRETE SUBSTRATE, SEE PAGE 13. PLEASE CHECK ALL. IF |
| | CONCRETE IS SPECIFIED AS A SUBSTRATE, EVIDENCE SHOWING |
| | THAT THE EXISTING CONCRETE MEETS THE MINIMUM DESIGN |
| | STRENGTH REQUIRED ON THE PRODUCT APPROVAL WILL BE |
| | REQUIRED. |
| | |
| | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, |
| | FAC9B72. EVALUATION REPORTS WERE SUBMITTED WITHOUT THE |
| | FLORIDA STATE PRODUCT APPROVAL COVER SHEETS. PLEASE |
| | PROVIDE THIS TO SHOW COMPLIANCE WITH FAC9B72. THEY MAY |
| | BE AVAILABLE AT WWW.FLORIDABUILDING.ORG. |
| | |
| | 3. SEE OPENING 9. SPECIFIC ANCHOR TYPE, ITW TAPCON |
| | PROPOSED. SEE SHEET 10 OF THE PRODUCT APPROVAL, |
| | MOUNTING TYPE 1 , TAPCON REQUIRES 7" SPACING FOR 3 1/2" |
| | EDGE DISTANCE, REQUIRES A FACTOR. THE PRODUCT APPROVALS |
| | ARE NOT LEGIBLE SO I CANNOT DETERMINE THE FACTOR |
| | REQUIRED. |
| | |
| | 4. PLEASE PROVIDE LEGIBLE PRODUCT APPROVALS. FOR |
| | INSTANCE, PAGE 10 HAS A PORTION OF THE SHEET CUT OFF. |
| | THE FACTOR REQUIRED IS ILLEGIBLE, AND THE SPACING FOR |
| | 12" CONNECTION TYPE 1 TO MASONRY IS DIFFICULT TO READ |
| | AS IT APPEARS TO BE A PHOTOCOPY OF SOMETHING THAT HAD |
| | BEEN OBSCURED BY HIGHLIGHTER. |
| | |
| | 5. SOME INFORMATION NOT PERTINENT TO THIS JOB HAS BEEN |
| | HIGHLIGHTED. FOR INSTANCE, SHEET 10, 9" SPACING (TO |
| | CONCRETE) HIGHLIGHTED. ALL INFORMATION WHICH IS EITHER |
| | HIGHLIGHTED OR CIRCLED IS HELPFUL FOR INSPECTIONS BUT |
| | SHOULD CORRELATE WITH THE INSTALLATION SCHEDULE AND |
| | WITH THE JOB. |
| | |
| | 6. PLEASE CHECK ALL ANCHOR SPACING, CONNECTIONS, ETC. |
| | ON THE PLAN. SOME COMMENTS MAY APPLY TO OTHER OPENINGS; |
| | THE OPENING NUMBER IN THE COMMENT LIST MAY BE AN |
| | EXAMPLE OF A NON COMPLIANT ITEM WHICH MAY APPLY TO |
| | OTHER OPENINGS. |
| | |
| | |
| | |