|
 |
 |
 |
 |
 |
Plan Review Details - Permit 09020303
| Plan Review Stops For Permit 09020303 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-02-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-02-19 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-02-19 |
Time |
13:56 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-26 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-26 |
Time |
13:02 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-02-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-18 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-18 |
Time |
10:32 |
Sent To |
P |
|
| Notes |
| 2009-02-18 10:56:12 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} SHEET D-1 SHOWS A JUNCTION BOX BEING REMOVED. THIS | | | IS IN THE AREA OF A REQUIRED LIGHTING OUTLET, SHOW | | | COMPLIANCE WITH NEC ARTICLE 210.70(A)(1) HABITABLE | | | ROOMS AT LEAST ONE WALL SWITCH-CONTROLLED LIGHTING | | | OUTLET SHALL BE INSTALLED IN EVERY HABITABLE ROOM AND | | | BATHROOM. | | | EXCEPTION NO. 1: IN OTHER THAN KITCHENS AND BATHROOMS, | | | ONE OR MORE RECEPTACLES CONTROLLED BY A WALL SWITCH | | | SHALL BE PERMITTED IN LIEU OF LIGHTING OUTLETS. | | | | | | 2} PROVIDE A LOAD CALCULATION PER 220.83 TO SHOW THE | | | EXISTING SERVICE RATING WILL SUPPORT THE NEW TANKLESS | | | SHOWN ON SHEET A-1. PROVIDE SPECIFICATIONS FOR THE | | | WATER HEATER. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-26 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-26 |
Time |
12:30 |
Sent To |
E |
|
| Notes |
| 2009-02-26 12:30:40 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-23 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-17 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2009-02-17 10:05:41 | TO "SFR" "E" |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-23 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-23 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |