| Plan Review Stops For Permit 09020294 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
jnguyen |
Date |
2009-05-18 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
jnguyen |
Date |
2009-05-15 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2009-05-18 10:25:30 | I HAVE TAKEN A LOOK AT THE SITE PLAN & NOTICED THAT THE | | | PROSPECTIVE WORK AREA DOES NOT OCCUR WITHIN THE | | | BOUNDARIES OF PCN# 74424311010190000 AT 4325 N | | | HAVERHILL RD (WPB WASTEWATER TREATMENT PLANT). THERE IS | | | AN ADDRESSING ISSUE FOR THE WPB WASTEWATER TREATMENT | | | PLANT BECAUSE ACCESS DOES NOT OCCUR OFF N HAVERHILL RD, | | | BUT INSTEAD EASLEY DR (THERE WILL BE AN ATTEMPT MADE BY | | | ME TO EVENTUALLY TRY TO RESOLVE THIS ISSUE WITH OUR | | | CITY'S WASTEWATER DEPARTMENT.). HOWEVER, THAT ISSUE | | | WILL BE A WORK IN PROGRESS THAT DOES NOT PARTICULARLY | | | APPLY TO THIS PERMIT. FROM MY OBSERVATION OF THE SITE | | | PLANS, THE AREA OF ALTERATION ACTUALLY TAKES PLACE ON | | | THE PARCEL TO THE SOUTH, PCN# 74424311010350000 WITH A | | | GENERAL PRIMARY ADDRESS OF 4335 EASLEY DR (WHICH MY | | | PREDECESSOR, LILI ISSUED BACK ON 8-25-2006). FOR THE | | | RECORD, I NEVER ISSUED ANY ADDRESSES BACK IN EARLY | | | APRIL, I SIMPLY "VERIFIED" EXISTING ADDRESSES & PARCELS | | | THAT WE CURRENTLY HAD ON FILE IN OUR DATABASES FOR A | | | CITIZEN, PETER GILSTAD. IT JUST TURNED OUT THAT 4335 | | | EASLEY DR ON 74424311010350000 WAS APPROPRIATELY VALID | | | TO BE USED FOR THIS PARTICULAR PERMIT. IN | | | COMMUNITYPLUS, PLEASE MOVE THIS PERMIT RECORD FROM PCN# | | | 74424311010190000 AT 4325 N HAVERHILL RD TO BE | | | CORRECTLY APPLIED INSTEAD TO PCN# 4424311010350000 AT | | | 4335 EASLEY DR (AS I DO NOT HAVE AUTHORIZATION TO | | | IMPLEMENT THIS PROCEDURE). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-06-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-06-11 |
Time |
1:55 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2009-06-11 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2009-06-11 12:56:50 | PLANS OK TO ISSUE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-05-14 |
Time |
10:17 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2009-05-14 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2009-05-14 10:21:56 | BUILDING PLAN REVIEW | | | PERMIT: 09020294 | | | ADD: 4325 N HAVERHILL RD. | | | CONT: MAJOR WORKING DRAWING REVIEW | | | TEL: (561)632-5317 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | MAY 14TH, 2009 | | | 2ND REVIEW | | | ACTION: DENIED | | | 1A) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | NOTE: PLANS THAT ARE SUBMITTED FIRST TIME UNDER A | | | PERMIT APPLICATION STARTING MARCH 1, 2009 WILL BE | | | REVIEWED TO THE 2007 FBC, WITH THE 2009 SUPPLEMENTS | | | THIS START DATE IS A MANDATED IMPLEMENTION DATE STATE | | | WIDE. | | | SINCE TO DATE NO CONTRACTOR HAS MADE APPLICATION TO | | | CHANGE THIS MAJOR WORKING DRAWING REVIEW INTO A PERMIT | | | APPLICATION THIS REVIEW WILL BE COMPLETED UNDER THE | | | 2007FBC WITH 2009 SUPPLEMENTS, PLEASE UPDATE ALL PLANS | | | TO REFECT AS SUCH!. SHEET S0.1. | | | | | | CALLED RCT ENGINEERING TO SPEAK TO MR WILLIAM KIAHON P. | | | E. ABOUT A NEW S0.1, 2007 FBC W/ 2009 SUPPLEMENTS. THE | | | RECEPTIONIST INDICATED MR KIAHON IS OUT OF THE COUNTRY | | | UNTIL NEXT WEEK. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-03-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-03-11 |
Time |
09:43 |
Rev Time |
7.55 |
| Received By |
jwitmer |
Date |
2009-03-11 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2009-03-11 10:06:12 | BUILDING PLAN REVIEW | | | PERMIT: 09020294 | | | ADD: 4325 N HAVERHILL RD. | | | CONT: MAJOR WORKING DRAWING REVIEW | | | TEL: (561)632-5317 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOROR | | | RESIDENT INSPECTOR, THEN (3) THREE SETS OF ALL SAID | | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | | /2004 SUBMITTAL DOCUMENTS WEST PALM BEACH | | | ADMINISTRATIVE CODE. | | | | | | 1C) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1E) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | NOTE: PLANS THAT ARE SUBMITTED FIRST TIME UNDER A | | | PERMIT APPLICATION STARTING MARCH 1, 2009 WILL BE | | | REVIEWED TO THE 2007 FBC, WITH THE 2009 SUPPLEMENTS | | | THIS START DATE IS A MANDATED IMPLEMENTION DATE STATE | | | WIDE. | | | SINCE TO DATE NO CONTRACTOR HAS MADE APPLICATION TO | | | CHANGE THIS MAJOR WORKING DRAWING REVIEW INTO A PERMIT | | | APPLICATION THIS REVIEW WILL BE COMPLETED UNDER THE | | | 2007FBC WITH 2009 SUPPLEMENTS, PLEASE UPDATE ALL PLANS | | | TO REFECT AS SUCH!. SHEET A9.0 & S0.1. | | | | | | 2) SHEET A9.0 INDICATES FIRE SPRINKLERS NOT REQUIRED | | | AND NOTED PER THE REQUIREMENT OF PBC AMENDMENT TO THE | | | FIRE PREVENTION CODE SECTION 13.3.2.1.1.4. THIS | | | FACILITY IS LOCATED WITHIN THE | | | CITY OF WEST PALM BEACH, NOT THE COUNTY. ALSO NOTE | | | SINCE THE 2004 FBC THERE ARE NO LONGER LOCAL AMENDMENT | | | TO THE FBC EXCEPT FOR CHAPTER 1. | | | | | | 3) SHEET A9.0 WILL NEED TO PROVIDE THE TYPES OF | | | MATERIALS TO BE STORED AND THE AMOUNTS TO DETERMINE THE | | | TYPE OF OCCUPANCY. WITHOUT THIS INFORMATION WE CAN NOT | | | CLASSIFY THIS BUILDING.THE PLANS INDICATE STORAGE OF | | | SODIUM HYPOCHLORITE. SECTION 307.2 UNDER THE DEFINITION | | | OF OXIDIZER THERE ARE FOUR CLASSIFICATIONS. PLEASE | | | IDENTIFY WHICH OF THESE CATEGORIES WE WILL BE DEALING | | | WITH AND THE AMOUNT TO BE STORED, STATE OF COMPOUND | | | (GAS, LIQUID OR SOLID) AND WHAT TYPE OF STORAGE | | | CONTAINER. ALSO PROVIDE THE MSDS SHEETS FOR THIS | | | COMPOUND AND OTHER CHEMICALS TO BE STORED WITHIN THIS | | | BUILDING. | | | | | | 4) THE COVERSHEET C1.1 INDICATES THE USE OF A 3MG | | | CHLORINE CONTACT STORAGE TANK, PLEASE PROVIDE | | | ADDITIONAL INFORMATION, IS THIS 3 MILLION GALLONS OF | | | CHLORINE, OR A MIXING TANK? IS THIS NEW CONSTRUCTION OR | | | JUST A TIE IN ASA INDICATED ON SHEET S99.1. | | | | | | 5) SHEET A9.0 INDICATES THIS BUILDING TO BE A TYPE II-B | | | CONSTRUCTION. WEST PALM BEACH ADMINISTRATIVE CODE | | | 109.3.7 (1) FOR BUILDINGS OF TYPE I OR II CONSTRUCTION | | | SHALL REQUIRE A RESIDENT INSPECTOR . A COPY OF THE | | | PAPERWORK SHALL BE ATTACHED. | | | | | | 6) 1802.2.1 QUESTIONABLE SOIL. WHERE THE | | | SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE | | | A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS | | | CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE | | | THAT THE NECESSARY INVESTIGATION BE MADE. SUCH | | | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 7) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT INSPECTOR | | | OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS | | | FOLLOWS: | | | 7A) EXTERIOR METAL DOORS SINGLE & DOUBLE DOORS | | | 7B) WALL LOUVERS | | | 7C) ROOFING ASSEMBLIES INCLUDING INSULATION | | | 7D) ROLL UP DOOR | | | | | | 8) NO ENERGY CALCULATIONS WERE SUBMITTED, SHALL COMPLY | | | WITH 13-101.1.1. METHOD A,B OR C. PLEASE PROVIDE THE | | | INPUT DATA REPORT WITH THE ENRGY CALCULATIONS, PLEASE | | | NOTE THE 2007 BUILDING CODE HAS UPDATED CHAPTER 13 BUT | | | THE 2009 SUPPLEMENTS ARE NOT AVAILABLE AS OF YET. | | | | | | 9) NOTE THAT SHEET A9.7 DETAIL 04 ROOF INSULATION THIS | | | AREA BY THE SCUPPER IS THE LOWEST LEVEL OF ROOF | | | INSULATION AND THIS AREA WOULD NEED TO MEET AS THE | | | MINIMUM R-VALUE LISSTED IN THE INPUT DATA REPORT. | | | 13-404.ABC.1. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-05-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-29 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-29 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-18 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-15 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2009-05-18 10:47:34 | **DENIED REVIEW ** | | | | | | 1) NOTE: REVIEW SHALL REMAIN IN FAILED STATUS UNTIL | | | SUCH TIME PERMIT APPLICATION HAS BEEN MADE WITH A | | | LICENSED CONTRACTOR. THIS WAS NOTED ON PREVIOUS REVIEW. | | | | | | ** ELECTRICAL PLANS CONTAIN STAMPS; PLEASE DO NOT | | | REVISE ANY PLANS UNTIL AFTER PERMIT ISSUANCE. IF SHEETS | | | ARE REVISED THEN THIS WILL REQUIRE A RE-REVIEW OF SAID | | | PROJECT. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-03 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-03 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2009-03-03 08:56:57 | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLANS HAVE ONLY BEEN SUBMITTED FOR PLAN REVIEW | | | UNDER THE 2004 CODE AND OTHER ADOPTED STANDARDS. THERE | | | WILL BE A CODE CHANGE AS OF MARCH 1ST, 2009 WHICH WILL | | | REQUIRE ALL PLANS TO BE REVISED TO THE NEW CODES. | | | PLEASE BE AWARE THE SUBMISSION OF PLANS FOR PLAN REVIEW | | | ONLY DOES NOT LOCK THE PROJECT IN UNDER THE CURRENT | | | CODES IN EFFECT. ONLY PERMIT APPLICATIONS UNDER A | | | LICENSED CONTRACTOR WITH REQUIRED MINIMUM FEES APPLIED | | | FOR BEFORE THAT DATE WILL *LOCK* THE PROJECT UNDER THE | | | CURRENT CODE EDITIONS. THIS WILL AFFECT THE DESIGNS ON | | | THE PROJECT FOR MANY ASPECTS HOWEVER THE ELECTRICAL | | | CODE IS NOT SCHEDULED TO BE CHANGED UNTIL JULY 1ST, | | | 2009. | | | | | | ** ANY REFERENCES BELOW TO FBC CHAPTER 1 IS BASED ON | | | AMENDMENTS AS ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 2) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE STATED | | | ON THE PLANS. THE PLANS MUST LIST THE ACTUAL DESIGN | | | DOCUMENTS. | | | THERE ARE SEVERAL SHEETS WITH REFERENCES TO CODES WHICH | | | ARE NO LONGER IN EFFECT. | | | FOR EXAMPLE: THE STATE FAC RULE 69A-60.003 AND .004 | | | ADOPTED THE 2006 NFPA-1 AND 2006 NFPA-101 BEFORE THE | | | ACTUAL ADOPTION OF THE NEW CODES. THE PLANS FOR EXAMPLE | | | ON SHEET A9.0 DOES LIST THE PREVIOUS CODES AS WELL THE | | | PREVIOUS ADOPTED RULE WHICH NO LONGER CONTAINS THESE | | | CODES REFERENCES. IF THE FAC RULE IS GOING TO BE PLACED | | | ON PLANS PLEASE REVISE TO THE SECTIONS AS NOTED ABOVE. | | | PLEASE ALSO SEE OTHER EXAMPLES SUCH AS REFERENCE TO THE | | | 2002 NFPA-70 ( NATIONAL ELECTRICAL CODE). THE FOLLOWING | | | CODES WILL BE STATED AND NEEDED ON BOTH THE | | | ARCHITECTURAL COVER SHEET AND ELECTRICAL PLANS. IT IS | | | NOTICED THAT SOME CODES ARE OK ON ELECTRICAL PLANS | | | HOWEVER NOT ALL. | | | PLEASE BE AWARE THAT SHEETS SUCH AS FIRE ALARM AND | | | STRUCTURAL SHEETS MAY NEED TO BE REVISED FOR CURRENT | | | CODES. | | | *** KEEP IN MIND IF THIS PROJECT HAS NOT APPLIED FOR | | | PERMIT BEFORE THE MARCH 1ST, 2009 DEADLINE ALL CODES | | | STATED BELOW MAY NOT BE ACCURATE. | | | *** MANY SHEETS IN THE SETS OF PLANS SUBMITTED ALSO | | | STATE * PALM BEACH COUNTY* AS THE AMENDED LOCAL | | | AUTHORITY. AS THIS PROJECT IS IN THE CITY OF WEST PALM | | | BEACH PLEASE ADJUST NOTES ACCORDINGLY. THIS IS STATED | | | ON NUMEROUS SHEETS AND PLANS. | | | PLEASE LIST AS FOLLOWS BASED ON CURRENT CODES. IF | | | APPLICATION IS NOT MADE SOME OTHER CODES WILL CHANGE. | | | 2004 FBC W/2007 REVISIONS | | | 2005 NFPA-70 | | | 2006 NFPA-101 | | | 2006 NFPA-1 | | | 2002 NFPA-72 | | | | | | ** NOTES UPDATED: AS PERMIT HAS NOT BEEN APPLIED FOR | | | BEFORE MARCH 1ST, THE NEW CODES SHALL BE BASED ON THE | | | 2007 FBC. | | | | | | | | | 3) NOTE: IN THE SET OF PLANS REVIEWED THERE ARE SEVERAL | | | SHEETS WHICH WERE SIGNED AND DATED HOWEVER THEY ARE | | | MISSING THE REQUIRED RAISED SEAL PER FS 471.025 AND FAC | | | 61G15-23.002. | | | MANY OF THESE SHEETS ARE NOT ELECTRICAL IN NATURE | | | HOWEVER THIS IS GIVEN AS A BENEFIT FOR INFORMATION. | | | SHEETS: CU1.1,1.3,1.4,1.5 , CP 1.1,1.2, 1.4 AND 1.6 | | | THROUGH C9.18. | | | THIS IS NOTED FOR DESIGN TEAM ONLY BY THIS REVIEWER. IF | | | COMMENT IS NOT MADE BY OTHER TRADE(S) THIS IS STILL | | | REQUIRED. | | | FS 481.221, 471.025 | | | | | | 4) NOTE: ANY * LOCK OFF* TYPE OF BREAKERS ON THIS | | | PROJECT SHALL HAVE THE LOCK OFF DEVICE BE AN INTEGRAL | | | PART OF THE BREAKER. MOST OF THE CLIP ON OR SNAP ON | | | TYPE DEVICES ARE NOT LISTED FOR PERMANENT INSTALLATION. | | | PLEASE MAKE NOTE ON PLANS FOR THE TYPE OF BREAKERS | | | REQUIRED. THE DIVISION SPECIFICATIONS WERE NOT CLEAR TO | | | THE ACTUAL TYPE OF DEVICE INTENDED. | | | 110.3 | | | FBC 106.1.1, 106.1.2 FOR ADDITIONAL INFORMATION AND | | | CLARITY. | | | | | | 5) NOTE: THE RISER CLEARLY INDICATES A CONNECTION OF A | | | PORTABLE GENERATOR WITHOUT ANY FAIL SAFE OPERATION OF A | | | TRANSFER SWITCH OF DEVICE OF SOME SORT. THIS | | | INSTALLATION DOES NOT MEET 702.6. THE PROPOSED KIRK KEY | | | INTERLOCK IS NOT A LISTED TRANSFER SWITCH OR DEVICE. IT | | | ALSO DOES NOT PROVIDE FAIL SAFE OPERATION. PLEASE BE | | | AWARE THAT INSTALLATION OF THIS TYPE OF DEVICE MAY ALSO | | | VOID LISTING AND OR WARRANTY OF EQUIPMENT. | | | 110.3 | | | THIS COMMENT IS WITH RESPECT TO ALL PANELS AND ALL | | | EQUIPMENT ON RISER WHICH INDICATE THIS SAME KIRK KEY | | | INTERLOCK SYSTEM. | | | THE INSTALLATION OF A PORTABLE GENERATOR WITH OUT THE | | | USE OF TRANSFER EQUIPMENT MAY BE PART OF THE EXCEPTION. | | | PLEASE PROVIDE AN ORIGINAL NOTARIZED LETTER FROM THE | | | RESPONSIBLE AUTHORITY WHICH STATES THIS ENTIRE SCOPE OF | | | WORK WILL ONLY BE DONE BY *QUALIFIED PERSONNEL* PER THE | | | DEFINITIONS IN THE NATIONAL ELECTRICAL CODE ARTICLE | | | 100. THIS DOES NOT NEGATE THE FIRST PART OF THIS NOTE | | | WITH RESPECT TO THE KIRK KEY BEING LISTED OR VOID | | | LISTING OF EQUIPMENT. | | | SEE OTHER NOTES BELOW WITH RESPECT TO ARC FLASH AND | | | OTHER HAZARDS. | | | | | | 6) NOTE: PLEASE PROVIDE INFORMATION ON THE REQUIRED | | | GROUND FAULT PROTECTION OF MAINS PER 240.13 AND 230.95. | | | | | | 7) NOTE: PLEASE ALSO PROVIDE NOTES OR INFORMATION ON | | | ALL MAINS. THE RISER LENDS TO THE FACT BOTH OF THESE | | | ARE SHUNT TRIP HOWEVER DO BOTH OF THESE STILL CONTAIN | | | THE REQUIRED MANUAL MEANS OF DISCONNECT RATED FOR THE | | | LOAD SERVED PER 230.76 AND 230.79? | | | IF ACTUAL LISTING IS PROVIDED THIS MAY ALSO HELP ANSWER | | | QUESTION. | | | | | | 8) NOTE: PLEASE PROVIDE INFORMATION ON TRANSFORMERS AS | | | THE OVER CURRENT PROTECTION IS EXCEEDING THE MAXIMUM | | | 125% BASED ON 450.3. | | | IF MEETING NOTES IN TABLES, TYPE OF UNIT NEEDS TO BE | | | VERIFIED AND STATED ON PLANS. IF NOT MEETING NOTES ON | | | TABLE 450.3 THE MAXIMUM OVER CURRENT PROTECTION SHALL | | | BE 125%. | | | | | | 9) NOTE: PLEASE VERIFY ALL TRANSFORMER LOCATIONS FOR | | | LENGTH OF TAPPED CONDUCTORS PER 240.21. THE TAP RULES | | | ARE BASED ON THE LENGTH OF CONDUCTORS AND AS SOME SEEM | | | TO PERHAPS BE LOCATED SO THE LENGTHS ARE OVER THE | | | ALLOWANCES IN THE SECTION NOTED, THIS NEEDS TO BE | | | VERIFIED AT THIS TIME. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | 2009-02-25 16:54:43 | REVIEW HAS COMMENCED. ONCE REVIEW IS COMPLETED REVIEW | | | WILL PROCEED INTO A FAILED STATUS. | | | REVIEW WILL CONTINUE ON 3/2 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
efabian |
Date |
2009-05-13 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
efabian |
Date |
2009-05-12 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2009-06-03 11:41:24 | PASSED | | | | | | PLAN REVIEW FEE RECEIVED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2009-03-17 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
dlauderm |
Date |
2009-03-17 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG-A |
ENGINEERING FORMAL REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
efabian |
Date |
2009-04-08 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
efabian |
Date |
2009-04-02 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2009-06-03 11:16:10 | PASSED WITH PROVISO | | | | | | ALL DOCUMENTS/PLANS ARE RECIEVED AND ARE SATISFACTORY | | | | | | APPROVAL IS PENDING PAYMENT OF PLAN REVIEW FEE |
|
|
| Review Stop |
ENG-F |
ENGINEERING FINAL DRAWING REV |
| Rev No |
2 |
Status |
P |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
efabian |
Date |
2009-05-29 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
efabian |
Date |
2009-05-29 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2009-06-03 11:45:14 | INFRASTUCTURE REPORTS PART I AND II | | | RECEIVED |
|
|
| Review Stop |
ENG-F |
ENGINEERING FINAL DRAWING REV |
| Rev No |
1 |
Status |
P |
Date |
2009-05-29 |
|
|
Cont ID |
|
| Sent By |
efabian |
Date |
2009-05-28 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
efabian |
Date |
2009-05-28 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2009-06-03 11:36:50 | PASSED | | | | | | CONSTRUCTION ADMINISTRTION FEE RECIEVED | | | | | | REQUESTED APPROVED PRODUCTS LIST | | | BE SUBMITTED PRIOR TO A PRE-CONSTRUCTION MEETING |
|
|
| Review Stop |
ENG-M |
ENGINEERING MODIFICATION REV |
| Rev No |
1 |
Status |
P |
Date |
2009-06-02 |
|
|
Cont ID |
|
| Sent By |
efabian |
Date |
2009-03-30 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
efabian |
Date |
2009-03-24 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2009-06-02 15:10:07 | STATUS - PASSED WITH PROVISOS | | | | | | NOTE: LAST (THIS PAST MARCH 2009) PLANS ARE PASSED WITH | | | A FEW MINOR PROVISOS | | | WHICH INCLUDED | | | | | | LIFT STATION PLAN/DETAILS AND SOME ADDITIONAL REVISIONS | | | NOTED ON PLANS. | | | | | | CERTIFIED COST ESTIMATE & PLAN REVIEW FEE | | | | | | | | | PRIOR TO THE MARCH 2009 PLANS SUBMITTALS, BOTH 60% AND | | | 90% PLANS WERE REVIEWED AND REVISED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2009-06-12 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2009-06-12 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2009-06-12 09:49:35 | DISCUSSED WITH CAPT. MIKE WENNERGREN ON 6/11/09. PLANS | | | ALREADY STAMPED BY CAPT. MIKE WILLIAMS (SEE FIRE REVIEW | | | COMMENTS ON 5/18/09 REVIEW). CONTRACTOR PERMIT | | | APPLICATION FORM HAS SINCE BEEN SUBMITTED AND FEES | | | PAID, SO CAPT. WILLIAMS REQUIREMENTS HAVE BEEN MET. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2009-05-18 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-18 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-18 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2009-05-18 12:29:39 | *****PROVISO***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED; PLAN SHEETS C91.6, A9.0, A9.1, A9.2, | | | A9.4, F0.1,F0.2, F0.3, F9.1, AND E9.2 WERE STAMPED, | | | INITIALED, AND DATED. PLEASE BE ADVISED, HOWEVER THE | | | REVIEW SHALL REMAIN IN FAILED STATUS UNTIL SUCH TIME | | | PERMIT APPLICATION HAS BEEN MADE WITH A LICENSED | | | CONTRACTOR. | | | | | | | | | | | | CAPT. MICHAEL A.WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-03-31 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-03-31 |
Time |
21:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-03-31 |
Time |
20:02 |
Sent To |
B |
|
| Notes |
| 2009-04-01 10:30:23 | *****DENIED***** | | | | | | | | | 01. THE PROJECT SITE ADDRESS SHALL BE IN THE TITLE | | | BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 02. FIRE DEPARTMENT ACCESS ROADS SHALL BE DESIGNED AND | | | MAINTAINED TO SUPPORT THE IMPOSED LOADS OF FIRE | | | APPARATUS AND SHALL BE PROVIDED WITH AN ALL-WEATHER | | | DRIVING SURFACE. | | | | | | 03. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | | EDITION. | | | | | | 04. ON SHEET C91.6 INCLUDE IN NOTES AND/OR SHOW ON | | | DIAGRAM THAT IN ADDITION TO THE ELECTRONIC SWITCH, THE | | | OS&Y VALVE SHALL BE REQUIRED TO BE CHAINED AND LOCKED. | | | | | | 05. THE 2007 EDITION FLORIDA FIRE PREVENTION CODE | | | (BASED ON NFPA 1- UNIFORM FIRE CODE - 2006 EDITION AND | | | NFPA 101 - LIFE SAFETY CODE - 2006 EDITION) SHALL BE | | | REFERENCED. | | | | | | 06. ON SHEET A9.0, THE DEAD END CORRIDOR IN A | | | NON-SPRINKLERED BUILDING SHALL BE 20' INSTEAD OF 50' AS | | | LISTED IN THE CODE REQUIREMENT SECTION. | | | | | | 07. ON SHEET A9.0, THE COMMON PATH REQUIREMENT FOR A | | | NON-SPRINKLERED BUILDING SHALL BE 50' INSTEAD 100' AS | | | LISTED IN THE CODE REQUIREMNT SECTION. | | | | | | 08. ON SHEET A9.0, REFERENCE IS MADE TO AUTOMATIC FIRE | | | SPRINKLER SYSTEM - NOT REQUIRED - PER THE REQUIREMENT | | | OF PBC AMENDMENT TO THE FLORIDA FIRE PREVENTION CODE | | | 13.3.2.1.1.4; HAS THIS AMENDMENT BEEN ADOPTED BY THE | | | JURISDICTION OF THE CITY OF WEST PALM BEACH? | | | | | | 09. ON SHEET A9.0, ELIMINATE/AMEND NOTE #9 UNDER | | | APPLICABLE CODES. | | | | | | 10. IF ANY, WHAT TYPE OF CHEMICALS WILL BE STORED AT | | | THE FACILITY AND IN WHAT QUANTITIES? | | | | | | 11. WILL THERE BE ANY MARKING, IDENTIFICATION, | | | PLACARDING, ETC TO BE UTILIZED AT THE FACILITY? AND IF | | | SO, PLEASE SHOW ON THE APPROPIATE PLAN SHEET. | | | | | | 12. SHOW/DISPLAY THE NUMERICAL ADDRESS ON THE | | | APPROPIATE EXTERIOR ELEVATION FRONTING OR FACING THE | | | STREET OR PRINCIPAL VEHICULAR ACCESS TO THE PREMISES. | | | AS PER WEST PALM BEACH CODE, THE NUMBERS SHALL BE NO | | | LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN | | | WIDTH/STROKE. | | | | | | 13. ON SHEET F0.1 UPDATE REFERENCES TO NFPA 101 TO THE | | | 2006 EDITION AND ELIMINATE REFERERENCE(S) TO PALM BEACH | | | COUNTY CODES. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCEESS, INCLUDE A | | | RESPONSE LETTER INDICATING HOW/WHERE ON THE APPROPIATE | | | PLAN SHEET EACH COMMENT WERE ADDRESSED | | | | | | | | | | | | CAPT. MICHAEL A.WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-02-24 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-06-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-06-11 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2009-06-11 09:44:28 | IN C34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-04-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-30 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-30 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-03-31 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-03-31 |
Time |
20:02 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-02-13 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2009-02-13 15:35:26 | TO "COMM" BD#23/PLANS ON RACK--2 ROLLS AND PAPERWORK |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-05-22 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-05-22 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-05-22 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2009-05-22 11:47:08 | ***LANDSCAPE REVIEW PASSED WITH PROVISO*** | | | | | | SUBMIT NEW TREE ALTERATION APPLICATION AND TWO (2) | | | COPIES OF THE MOST CURRENT APPROVED LANDSCAPE PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-12 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-12 |
Time |
10:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-05-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-14 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-14 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2009-05-14 15:34:21 | **PLAN CHECK ONLY** | | | | | | PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE AND | | | PASSED. HOWEVER, REVIEW WILL REMAIN IN FAIL STATUS | | | PENDING RECEIPT OF AN APPLICATION FOR PERMIT. ONCE | | | PERMIT IS READY TO ISSUE, A PROVISO WILL BE ADDED TO | | | PLANS REQUIRING ADEQUATE SUPPORTING DOCUMENTATION | | | REGARDING THE WIND RESISTANCE CAPABILITIES OF THE | | | OUTDOOR MECHANICAL APPLIANCES. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-21 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-21 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2009-02-21 14:27:41 | REVIEW #: 1ST **PLAN CHECK ONLY** | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. F-901 AND F-903 ARE SHOWN AS SUPPLY FANS WITH A | | | DESIGN CAPACITY EXCEEDING 2000 CFM. SMOKE DETECTORS | | | SHALL BE INSTALLED IN SUPPLY AIR SYSTEMS WITH A DESIGN | | | CAPACITY GREATER THAN 2,000 CFM IN THE SUPPLY AIR DUCT | | | IN ACCORDANCE WITH FBC-M 606.2.1. DUCT SMOKE DETECTORS | | | SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM IN | | | ACCORDANCE WITH BFC-M 606.4. | | | | | | 2. THE MOTORIZED DAMPER SCHEDULE CALLS FOR MOTORIZED | | | DAMPER MD-902 RO BE INTERCONNECTED WITH AHU-901. IT IS | | | NOT CLEAR WHY IT WOULD BE INTERCONNECTED WITH SHU-901 | | | WHEN IT SERVES AHU-902. PLEASE CLARIFY THE DESIGN | | | INTENT IN ACCORDANCE WITH FBC-M 603.1 AND FBC-B | | | 106.1.1. | | | | | | 3. THEFAN SCHEDULE CALLS FOR F-901 AND F-902 TO BE | | | EQUIPPED WITH EXPLOSION-PROOF MOTORS. DOES THIS | | | REQUIREMENT APPLY TO ALL MOTORS AT THIS LOCATION? IS | | | THIS A CLASS LOCATION PER NEC REQUIREMENTS? PLEASE | | | CLARIFY WHETHER THE MOTORIZED DAMPER MOTORS ARE | | | REQUIRED TO BE DESIGNED FOR A CLASS LOCATION IN | | | CONJUNCTION WITH THE FANS THEMSELVES. | | | | | | 4. NO STRUCTURAL DETAIL COULD BE FOUND FOR ANCHORING OF | | | THE OUTDOOR CONDENSING UNITS FOR WIND RESISTANCE. ALSO, | | | NO SUPPORTING DOCUMENTATION WAS PROVIDED SHOWING THESE | | | OUTDOOR APPLIANCES ARE DESIGNED FOR WIND RESISTANCE. | | | MECHANICAL APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES AS DETERMINED IN ACCORDANCE WITH FBCM 301.13. | | | PROVIDE STRUCTURAL DETAIL FOR ATTACHMENT OF THE | | | APPLIANCES FOR WIND RESISTANCE AS WELL AS SUPPORTING | | | DOCUMENTATION SHOWING THE APPLIANCES THEMSELVES ARE | | | DESIGNED TO RESIST THE ANTICIPATED WIND PRESSURES IN | | | ACCORDANCE WITH THIS SECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-08 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-08 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2009-05-08 14:19:56 | ATTACHMENT "J" FRESH AIR INLET COVER NOT APPROVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-26 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-26 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2009-02-26 11:03:00 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHTS IR1.3, IR1.4 & IR99.1 THE FOLLOWING INFORMATION | | | IS MISSING FROM THE TITLE BLOCKS OF EACH SHEET. THE | | | FIRM LICENSE NUMBER, (CERTIFICATE OF AUTHROIZATION), | | | AND THE PRINTED NAME OF THE PERSON SEALING THE | | | DOCUMENT. FAC 61G1-16.004(2)(6) & FS 481.306. | | | | | | 2. SHTS A9.1 THRU A9.8 THE FOLLOWING INFORMATION IS | | | MISSING FROM THE TITLE BLOCKS OF EACH SHEET. THE | | | PRINTED NAME OF THE PERSON SEALING THE DOCUMENT. FAC | | | 61G1-16.004(6) & FS 481.2055. | | | | | | 3. SHT A9.1 PER TABLE 403.1 A DRINKING FOUNTAIN AND A | | | SERVICE SINK ARE REQUIRED FOR THE "F" OCCUPANCY. PLEASE | | | INDICATE THE LOCATION OF EACH REQUIRED FIXTURE. | | | | | | 4. SHTS A9.1 & A9.2 SHOW COMPLIANCE WITH THE FOLLOWING: | | | ___W/C: | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | ___LAV: | | | A. 11-4.19.3 CLEAR FLOOR SPACE | | | B. 11-4.19.5 FAUCETS | | | ___FOR TOILET ROOM: | | | A. 11-4.22.3 TURNING AREA | | | | | | 5. SUBMIT A DETAIL FOR THE REQUIRED DRINKING FOUNTAIN | | | SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH ALL | | | SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A) | | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | | | | 6. SHTS M0.1 THRU M9.3 THE FOLLOWING INFORMATION IS | | | MISSING FROM THE TITLE BLOCKS OF EACH SHEET. THE | | | PRINTED NAME AND LICENSE NUMBER OF THE PERSON SEALING | | | THE DOCUMENT. FAC 61G15-23.002(2) & FS 471.025. | | | | | | 7. SHTS M9.2 & M9.3 INDICATES THE VENT FOR THE SANITARY | | | PIPING AS A FRESH AIR INTAKE. THIS IS NOT CORRECT AS IT | | | IS NOT A FRESH AIR INTAKE. PLEASE CLARIFY. SECTIONS | | | 106.1.1 | | | | | | 8. SHTS M9.2 PLUMBING PLAN & M9.3 SANITARY RISER | | | DIAGRAM. THE VENT OFFSET BELOW THE FLOOR IS NOT | | | APPROVED AT THE WATER CLOSET, NOR AT THE FLOOR DRAIN IN | | | THE GENERATOR ROOM. SECTION 905.4. EVERY DRY VENT SHALL | | | RISE VERTICALLY TO A MINIMUM OF 6 INCHES ABOVE THE | | | FLOOD LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE | | | SERVED. | | | | | | 9. SUBMIT A SANITARY RISER DIAGRAM FOR THE FLOOR DRAINS | | | IN THE GENERATOR ROOM AND THE PUMP ROOM. SHOW ALL PIPE | | | SIZES, TRAPS AND VENTS. SECTION 106.3.5.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-05-21 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-05-21 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-05-21 |
Time |
18:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-02-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-02-24 |
Time |
19:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-02-24 |
Time |
19:07 |
Sent To |
|
|
| Notes |
| 2009-02-24 19:15:37 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 09020294 | | | ADDRESS: 4325 HAVERHILL ROAD | | | CONTRACTOR/CONTACT: GREG SHAW | | | TELEPHONE NO.: (561) 632-8715 | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1) AS SUBMITTED AND APPROVED AS PART OF THE CLASS A | | | SPECIAL USE PERMIT, PLEASE PROVIDE A DETAILED SITE PLAN | | | IDENTIFYING ALL IMPROVEMENTS, DIMENSIONS, SETBACKS, AS | | | WELL AS TABULAR DATA INDICATING LANDSCAPE AREA, | | | STRUCTURE HEIGHT, ETC. PLEASE REFER TO THE ATTACHED | | | COPY OF THE APPROVED SITE PLAN. | | | | | | 2) THE PAVING/GRADING/DRAINAGE PLANS, AS WELL AS THE | | | LANDSCAPE PLANS, DO NOT MATCH WHAT WAS APPROVED BY THE | | | CITY COMMISSION AS PART OF THE CLASS A SPECIAL USE | | | PERMIT. PLEASE CONTACT ME REGARDING THIS COMMENT IF | | | MODIFICATIONS ARE BEING MADE FROM WHAT WAS APPROVED. | | | | | | 3) PLEASE PROVIDE A COPY OF THE APPROVED TREE | | | ALTERATION PERMIT. CONTACT ROBERT KUSSNER, LANDSCAPE | | | PLANNER, AT (561) 822-1462 TO OBTAIN A COPY. | | | | | | 4) PLEASE IDENTIFY ALL IMPROVEMENTS ON THE SITE PLAN | | | (I.E. WHAT ARE THE "INDIVIDUAL BLACK DOTS" SHOWN ON THE | | | PAVING/GRADING/DRAINAGE PLANS SURROUNDING THE RECLAIMED | | | WATER PUMP STATION?...ARE THESE BOLLARDS?). | | | | | | 5) PLEASE PROVIDE THE OVERALL HEIGHT OF ALL | | | FACILITIES/STRUCTURES, AS WELL AS LABEL AND NOTE THE | | | HEIGHT OF ALL APPURTENANCES ON TOP OF ALL OF THE | | | FACILITIES. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. | | | |
|
|