| Plan Review Stops For Permit 09020115 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-07-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-07-17 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-07-17 |
Time |
17:20 |
Sent To |
PC |
|
| Notes |
| 2009-07-17 17:21:22 | BUILDING REVISIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-03-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-03-04 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-03-04 |
Time |
13:42 |
Sent To |
PC |
|
| Notes |
| 2009-03-04 13:53:29 | BUILDING REVIEW APPROVED WITH PROVISO (PROVIDE | | | INFORMATION PRIOR TO INSPECTION TO AVOID ANY CONFLICTS | | | OR DELAYS): | | | | | | 1- REVISE CONSTRUCTION TYPE SPECIFIED ON SHEET TS-1. | | | SPECIFY CONSTRUCTION TYPE OF EXISTING OVERALL BUILDING, | | | NOT JUST THE PHARMACY AREA. | | | | | | 2- CLARIFY WHY PROVIDING 2 DIFFERENT WIND LOAD | | | CALCULATIONS. ONE FROM THE ARCHITECT AND THE OTHER ONE | | | FROM THE ENGINEER. CALCULATIONS DON'T MATCH EACH OTHER. | | | ENGINEER TO SIGN AND SEAL AND PROVIDE HIS INFORMATION | | | IN ALL SHEETS WITH ORIGINAL SIGNATURE AS REQUIRED BY | | | CHAPTER 471 FLORIDA STATUTE. ARCHITECT TO SIGN AND SEAL | | | AND PROVIDE HIS INFORMATION IN ALL SHEETS AS REQUIRED | | | BY CHAPTER 481 FLORIDA STATUTE. | | | ***NOTE: ONLY NEED TO PROVIDE CALCULATIONS DONE BY ONE | | | DESIGN PROFESSIONAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
2009-02-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-02-22 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-02-22 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2009-02-22 18:25:42 | COMMERCIAL BUILDING (MERCANTILE), BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | | UP. | | | | | | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | | (561)233-5120) TO VERIFY IF IMPACT FEES ARE DUE FOR | | | CHANGE OF USE. BRING BACK STAMPED PLANS AND COPY OF | | | PAID RECEIPT IF FEES ARE DUE. (REPEAT COMMENT). | | | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW TO COVER ALL WORK SHOWN ON PLANS. SEC. 108.3 CITY | | | AMENDMENTS TO FBC 2004. REVISE VALUATION TO INCLUDE | | | DEMOLITION FEES, PROFESSIONAL DESIGN FEES AND COMPLETE | | | SCOPE OF WORK TO BE PERFORMED. (REPEAT COMMENT). | | | | | | 4- SHEET TS-1: | | | A) REVISE CONSTRUCTION TYPE. THIS BUILDING CAN'T BE | | | TYPE VB UNPROTECTED. AREA OF WORK IS ONLY FOR ONE | | | TENANT. THERE ARE MORE TENANTS ON THIS BUILDING. THIS | | | CONSTRUCTION TYPE DOESN'T APPLY TO THE SIZE OF | | | BUILDING. REVISE CONSTRUCTION TYPE AS REQUIRED. (NEED | | | TO VERIFY CONSTRUCTION TYPE). | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-02-07 |
Time |
19:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-02-07 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2009-02-06 19:31:12 | COMMERCIAL BUILDING (MERCANTILE), BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | | UP. | | | | | | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | | (561)233-5120) TO VERIFY IF IMPACT FEES ARE DUE FOR | | | CHANGE OF USE. BRING BACK STAMPED PLANS AND COPY OF | | | PAID RECEIPT IF FEES ARE DUE. | | | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW TO COVER ALL WORK SHOWN ON PLANS. SEC. 108.3 CITY | | | AMENDMENTS TO FBC 2004. REVISE VALUATION TO INCLUDE | | | DEMOLITION FEES, PROFESSIONAL DESIGN FEES AND COMPLETE | | | SCOPE OF WORK TO BE PERFORMED. | | | | | | 4- SHEET TS-1: | | | A) REVISE CONSTRUCTION TYPE. THIS BUILDING CAN'T BE | | | TYPE VB UNPROTECTED. AREA OF WORK IS ONLY FOR ONE | | | TENANT. THERE ARE MORE TENANTS ON THIS BUILDING. THIS | | | CONSTRUCTION TYPE DOESN'T APPLY TO THE SIZE OF | | | BUILDING. REVISE CONSTRUCTION TYPE AS REQUIRED. | | | | | | B) SPECIFY IF BUILDING IS SPRINKLERED OR NOT. | | | | | | C) PROVIDE ONLY ONE TS-1 SHEET. THERE WERE TWO | | | SUBMITTED. | | | | | | D) UPDATE CODE INFORMATION. REFER TO 2007 REVISIONS, | | | NOT 2006. | | | | | | E) SPECIFY IF STRUCTURAL COLUMNS ARE REQUIRED TO BE | | | FIRE RATED. COORDINATE WITH ITEM #4A ABOVE AND TABLE | | | 601 FBC 2004. | | | | | | 5- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. 13-4 | | | OF FBC 2004. | | | | | | 6- WIND RESISTANCE CALCULATIONS FOR ROOF TOP A/C | | | EQUIPMENT: | | | A) UPDATE HVAC EQUIPMENT ROOF CURB DETAIL. REVISE | | | FLORIDA BUILDING CODE EDITION AND SECTION REFERENCED. | | | SEE FBC 2004. | | | | | | B) UPDATE AMENDMENTS REFERENCED ON COVER PAGE. REFER TO | | | 2007 REVISIONS, NOT 2006. | | | | | | 7- SHEET A-1.2: UPDATE GENERAL DESIGN CRITERIA: | | | * REFER TO 2007 REVISIONS, NOT 2006. | | | ** REVISE TABLES REFERENCED FOR LIVE LOADS. SEE FBC | | | 2004 FOR CORRECT TABLES AND REVISE AS REQUIRED. | | | | | | 8- SHEET A-2.2: | | | A) DOOR SCHEDULE IS MISSING SPECIFICATIONS FOR DOOR | | | "D". | | | | | | B) PROVIDE LAYOUTS, DETAILS AND SPECIFICATIONS FOR | | | GENERAL SALES AREA, FITTING ROOM AND LOUNGE AREA TO | | | SHOW COMPLIANCE WITH CHAPTER 11 REQUIREMENTS SEC. 11-7. | | | | | | C) CLEAN ROOM: PROVIDE COMPLETE WRITTEN DIMENSIONS AND | | | SIZES OF DOORS TO VERIFY COMPLIANCE WITH CHAPTER 11 FBC | | | 2004. | | | | | | D) PROVIDE COMPLETE SHOP DRAWINGS FOR CLEAN ROOM. SHOP | | | DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | E) SPECIFY WHAT'S THE PROPOSED USE OF SPACE BETWEEN | | | FRONT STOREFRONT AND CLEAN ROOM? | | | | | | 9- SHEET A-2.3: TENANT SEPARATION WT-5 IS ONLY FOR ONE | | | HOUR FIRE SEPARATION. NEED TO PROVIDE TENANT SEPARATION | | | AS REQUIRED BY TABLE 302.3.2 OF FBC 2004. REVISE AS | | | REQUIRED. ALSO, IDENTIFY OCCUPANCY USE OF TENANTS ON | | | BOTH SIDES OF STORE TO PROPERLY USE TABLE 302.3.2 | | | | | | 10- SHEET A-4.0 : | | | A) WAS NOT SIGNED, SEALED AND DATED AS REQUIRED BY | | | CHAPTER 481 FLORIDA STATUTE. | | | | | | B) UPDATE BUILDING CODE YEAR AND CODE SECTION CITED ON | | | HVAC EQUIPMENT ROOF CURB DETAIL. SEE FBC 2004 AND | | | REVISE AS REQUIRED. | | | | | | 11- SHEET A-4.1: | | | A) NAILING SCHEDULE DOESN'T APPLY TO THIS JOB. | | | | | | B) PROVIDE COMPLETE DETAILS AND DIMENSIONS FOR DETAILS | | | "C" AND "D" TO SHOW THE 16" HIGH VOID ON LEXAN WINDOWS | | | AND SHOWING COMPLIANCE WITH CHAPTER 11 FBC 2004 SEC. | | | 11-7. | | | | | | C) DETAIL "E" TO BE COORDINATED WITH ITEM #9 ABOVE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-07-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-07 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-07 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-05-26 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-05-26 |
Time |
13:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-20 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-20 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-02-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-09 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-09 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2009-02-09 07:19:19 | | | | | | | | | | APPLICATION #009020115 ELECTRICAL PLAN REVIEW | | | 2100 45TH STREET 2/6/09 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} INDICATE COMPLIANCE WITH 13-415.2ABC.1, PERFORMANCE | | | CALCULATION PROCEDURES. THIS CAN BE DEMONSTRATED ON THE | | | PLANS INDICATING THE WATTAGES OF THE LUMINAIRES CHOSEN | | | FOR THE PROJECT CONFORM TO THE DENSITY REQUIREMENTS. | | | INDICATE WATTAGES ON THE FIXTURE SCHEDULE TO CORRELATE | | | WITH THE ONES IN THE CALCULATIONS. SEE TABLE 13-415.2.B | | | | | | 2} SUBMIT A LEGEND OF FIXTURE TYPES AND WATTAGES ON THE | | | PLAN TO CORRELATE WITH THE ONES IN THE CALCULATIONS. | | | | | | 3} LOCATE SPACE CONTROL DEVICE TYPES AND LOCATIONS ON | | | THE PLAN PER 13-415.1.ABC.1.2 SPACE CONTROL. | | | | | | 4} FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN | | | THE FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE | | | INDICATE THE CODE CYCLES UNDER WHICH THIS PLAN WAS | | | DESIGNED. SEE ABOVE REFERENCES. SHEET TS-1 INCORRECTLY | | | REFERENCES THE 2001 & 2006 NEC . | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-02-23 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-02-23 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2009-02-23 10:43:46 | *****APPROVED W/PROVISO***** | | | | | | | | | PLAN SHEETS L-S.1, A-4.0, AND E-2.0 WERE STAMPED, | | | INITIALED, AND STAMPED; HOWEVER THE FOLLOWING COMMENT | | | WAS ADDED TO SHEET E-2.0: COORDINATE THE DISCREPANCY IN | | | THE LOCATION OF THE EMERGENCY LIGHT AS SHOWN ON BOTTOM | | | RIGHT HAND SECTION OF THE FLOOR LAYOUT ON L-S.1 AND | | | A-4.0, BUT IS NOT DISPLAYED ON E-2.0 SHEET. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-02-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-02-09 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-02-09 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2009-02-09 13:00:11 | *****DENIED***** | | | | | | | | | 1. ON SHEET THE COVER SHEET (TS-1), AMEND EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE FROM 2004 TO 2007 | | | WHICH SHALL BE REFERENCED. THE 2007 EDITION IS BASED | | | UPON NFPA 101, LIFE SAFETY CODE, 2006 EDITION AND NFPA | | | 1, UNIFORM FIRE CODE, 2006 EDITION. | | | | | | 2. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3. EXPLAIN AND/OR COORDINATE THE DISCREPANCY WITH THE | | | NUMBER AND LOCATION OF EXIT AND EMERGENCY LIGHTS AS | | | SHOWN ON L-S.1, A-4.0, AND E-2.0 SHEETS. | | | | | | 4. PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR | | | THIS TENANT SPACE IF SO EQUIPPED. SPRINKLER HEADS MAY | | | BE SHOWN ON THE REFLECTED CEILING SHEET (A-4.0). | | | | | | 5. PROVIDE A LAYOUT OF THE FIRE ALARM DEVICES FOR THIS | | | TENANT SPACE IF SO EQUIPPED. FIRE ALARM DEVICES MAY BE | | | SHOWN ON THE LIFE SAFETY SHEET (L-S.1). | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE/HOW EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-07-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-07 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-06 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2009-07-06 09:10:39 | TO C-4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-05-26 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-05-15 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2009-05-15 15:47:55 | ELECT REV TO B TROBAUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-03 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-03 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2009-03-03 11:13:18 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-20 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-20 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2009-02-20 15:58:27 | TO "COMM" BD#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-02-09 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-02-07 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2009-02-07 14:50:30 | 2-9-09 ALL TRADES COMPLETED REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-07-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-10 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-10 |
Time |
15:27 |
Sent To |
PC |
|
| Notes |
| 2009-07-10 15:27:52 | REVISED M-1.0 DELTA 3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-02-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-21 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-21 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2009-02-21 10:09:07 | ******PROVISO****** | | | PROVIDE MANUFACTURER'S SUBMITTAL DATA OR STRUCTURAL | | | ANALYSIS SHOWING NEW RTU AND VENT CAPS ARE DESIGNED FOR | | | WIND RESISTANCE IN ACCORDANCE WITH FBC-M 301.13. | | | SUPPORTING DOCUMENTATION SHALL BE SUBMITTED FOR PLAN | | | REVIEW PRIOR TO FINAL INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-06 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-06 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2009-02-09 07:48:05 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PG A-4.0: THE CRUB/RTU ATTACHMENT DETAIL REFERENCES | | | THE 2001 FBC AND SECTION 1511.7. THIS PROJECT WAS | | | SUBMITTED UNDER THE 2004 FBC WITH 2007 SUPPLEMENTS. | | | ALSO, THE CORRECT CODE SECTION FOR CURB HEIGHTS IS | | | 1509.7. PLEASE REFERENCE THE CORRECT CODE EDITION AND | | | SECTIONS ON ALL AREAS OF PLANS. | | | | | | 2. PG A-4.0 & M-2.0: THE CURB AND RTU INSTALLATION | | | DETAILS SHOWN ON THESE PAGES (AND ATTACHED | | | CALCULATIONS) ARE IN CONFLICT. WHICH IS CORRECT? PLEASE | | | CLARIFY AND DEMONSTRATE COMPLIANCE WITH FBCM 301.13. | | | | | | 3. PG M-2.0: DIFFUSER DETAIL ON THIS PAGE CALLS FOR 1" | | | WIDE STRAP AS SUPPORT FOR THE FLEX DUCT. N NO CASE | | | SHALL THE MATERIAL SUPPORTING FLEXIBLE DUCT THAT IS IN | | | DIRECT CONTACT WITH IT BE LESS THAN 1 1/2 INCHES WIDE | | | IN ACCORDANCE WITH FBCM 603.5.6.6(6). | | | | | | 4. PG M-2.0: DUCT DETECTOR DETAIL CALLS FOR AUDIBLE - | | | VISIBLE NOTIFICATION TO BE IN A "NORMALLY OCCUPIED" | | | LOCATION. THE SIGNALS ARE ACTUALLY REQUIRED TO BE IN AN | | | APPROVED LOCATION IN ACCORDANCE WITH FBCM 606.4.1. | | | CONSULT FIELD INSPECTOR TO DISCUSS AN APPROVED | | | LOCATION. | | | | | | 5. PG M-2.0: RTU DETAIL SAYS "SEE MECHANICAL PLAN" FOR | | | CONTINUATION OF CONDENSATE DRAIN LINE. NO CONTINUATION | | | COULD BE FOUND ON PLANS. CONDENSATE SHALL BE CONVEYED | | | FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF | | | DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO A STREET, | | | ALLEY OR OTHER AREAS SO AS TO CAUSE A NUISANCE IN | | | ACCORDANCE WITH FBCM 307.2.1. SHOW ON PLANS THE MEANS | | | AND LOCATION OF CONDENSATE DISPOSAL FOR NEW RTU. | | | | | | 6. WIND RESISTANCE: DETAILS AND CALCULATIONS FOR RTU | | | CAND RTU CURB ATTACHMENT WERE PROVIDED (SEE COMMENT #2 | | | ABOVE), BUT NO DETAIL WAS PROVIDED FOR VENT CAPS OR | | | VENT CAP CURBS. ALSO, NO INFORMATION WAS PROVIDED | | | REGARDING THE WIND RESISTANCE CAPABILITIES OF THE RTU | | | AND VENT CAPS THEMSELVES. EQUIPMENT AND APPLIANCES THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO | | | RESIST WIND PRESSURES AS DETERMINED IN ACCORDANCE WITH | | | FBCM 301.13. | | | | | | NOTE: PLEASE RESPOND TO EACH COMMENT IN WRITING, WITH | | | AN EXPLANATION OF HOW EACH COMMENT WAS ADDRESSED AND A | | | DESCRIPTION OF WHERE THE RELEVANT INFORMATION CAN BE | | | FOUND. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-07-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-10 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-10 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2009-07-10 13:58:49 | REVISION OK -- SHT P-1.0. -- THERMAL EXPANSION CONTROL | | | IS REQUIRED PER SECTION 607.3.2 & A PAN DRAIN IS | | | REQUIRED PER SECTION 507.4. -- A REVISION IS REQUIRED | | | FOR SHT A-2.2 TO REFLECT THE CHANGE TO THE SINK FROM | | | ACCESSIBLE TO NON-ACCESSIBLE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-20 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-20 |
Time |
18:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2009-02-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-07 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-07 |
Time |
18:23 |
Sent To |
|
|
| Notes |
|
|