| Plan Review Stops For Permit 09020082 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-05-26 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-05-26 |
Time |
20:37 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-05-26 |
Time |
20:37 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-03-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-03-27 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-03-27 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2009-03-27 08:53:24 | PROVISO: FBC 11-7: A PORTION OF THE MAIN COUNTER SHALL | | | BE A MINIMUM OF 36 INCHES IN LENGTH AND A MIXIMUM | | | HEIGHT OF 36 INCHES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-02-10 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-02-10 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-05-26 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-05-26 |
Time |
20:37 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-05-26 |
Time |
20:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-04-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-04-20 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-04-14 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2009-02-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-09 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-09 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2009-05-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-27 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-27 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2009-05-27 11:17:18 | *****REVISION, DATED 5/11/2009, APPROVED***** | | | | | | REVISED PLAN SHEETS M-1 AND E-2 (OF THE SUBMITTED 4 | | | SHEETS) WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-03-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-03-31 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-03-31 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2009-03-31 11:11:52 | RE-STAMP ONLY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2009-02-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-02-17 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-02-17 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2009-02-17 09:53:19 | LIFE SAFETY SHALL COMPLY WITH FLORIDA FIRE PREVENTION | | | CODE, 2007 EDITION TO INCLUDE NFPA 101, 2006 AND NFPA | | | 1, 2006 SINCE DECEMBER 31, 2008. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-28 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-28 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2009-04-28 15:29:20 | TO RR'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-10 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-10 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2009-03-10 08:41:57 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-02-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-17 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-05 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2009-02-05 16:35:46 | TO "BOB"#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-05-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-04 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-04 |
Time |
10:54 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-04-02 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-04-02 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2009-04-02 13:46:50 | PLAN DENIED | | | 1) PLEASE REFER TO TABLE 403.3 2007 FBC (M) FOR | | | BATHROOM EXHAUST 50 CFM PER WATER CLOSET . | | | 2) PLEASE PROVIDE DUCT SIZE FOR EXISTING SLOT DIFFUSERS | | | . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-15 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-15 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2009-02-15 11:03:47 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PAGE M-1: NOTE #15 CALLS FOR NEW DUCT PENETRATION OF | | | SHAFT ENCLOSURE WITH FIRE DAMPER FOR OUTSIDE AIR. SHAFT | | | ENCLOSURES THAT ARE PERMITTED TO BE PENETRATED BY DUCTS | | | AND AIR TRANSFER OPENINGS SHALL BE PROTECTED WITH | | | APPROVED FIRE AND SMOKE DAMPERS INSTALLED IN ACCORDANCE | | | WITH THEIR LISTING PER FBCM 607.5.5.1. | | | | | | 2. PAGE M-1: IS THE CEILING SPACE ABOVE THE EXISTING | | | BATHROOMS ISOLATED FROM THE PLENUM CEILING ON THE REST | | | OF THE FLOOR? NOTE ON THIS PAGE INDICATES THE CEILING | | | SPACE THROUGHOUT IS A RETURN AIR PLENUM.THE DUCT ON THE | | | DISCHARGE SIDE OF PROPOSED NEW EF-1 WILL BE UNDER | | | POSITIVE PRESSURE AND CANNOT BE LOCATED IN A PLENU IN | | | ACCORDANCE WITH FBCM 601.3. | | | | | | 3. M AND P PAGES: MECHANICAL DETAIL CALLS FOR AUXILIARY | | | DRAIN PAN WITH A FLOAT SWITCH AND NO SECONDARY DRAIN | | | LINE WHILE PLUMBING PLAN SHOWS SECONDARY DRAIN LINE RUN | | | FROM THE AUXILIARY DRAIN PAN TO ABOVE A SINK. WHICH IS | | | CORRECT? PLEASE COORDINATE PLANS AND SHOW COMPLIANCE | | | WITH FBCM 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-03-17 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-03-17 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-02-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-17 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-17 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2009-02-17 14:51:44 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | 1. ALL SHEETS WITH BIRSE DESIGN INC TITLE BLOCK. PER | | | FAC 61G1-16.004(2) THE FIRM ADDRESS IS REQUIRED. THE | | | ADDRESS INDICATED IN THE TITLE BLOCKS, (1511 PROSPERITY | | | FARMS ROAD LAKE PARK FLORIDA), DOES NOT REFLECT THE | | | ADDRESS OF RECORD ON THE STATE OF FLORIDA DBPR WEBSITE, | | | (10096 SEAGRAPE WAY PALM BEACH GARDENS FLORIDA). FS | | | 481.2055. PLEASE UPDATE THE TITLE BLOCKS OR THE DBPR | | | WEBSITE TO MATCH PRIOR TO RESUBMITTING FOR REVIEW. | | | | | | 2. SHT A-1 PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE | | | BREAK ROOM SINK AND THE TURNING AREA AS REQUIRED IN | | | CHAPTER 11 SECTIONS 11-4.24.5 AND 11-4.2.3. | | | | | | 3. SHT A-1 DEMO NOTE 4 INDICATES THE SANITARY/WASTE | | | LINES TO BE CAPPED OFF FLUSH WITH THE FLOOR. PER | | | SECTION 704.5 IN THE REMOVAL OF ANY PART OF A SANITARY | | | SYSTEM, DEAD ENDS ARE PROHIBITED. LINES SHALL BE CAPPED | | | OFF WITHIN 2 FEET OF A LIVE BRANCH LINE OR COMPLETLY | | | REMOVED. PLEASE INDICATE ON PLANS. | | | | | | 4. SHT A-3 DETAIL 1 NOTE INDICATES THAT A GARBAGE | | | DISPOSAL SHALL BE PROVIDED. SUBMIT A CUT DETAIL SHOWING | | | THE SINK & GARBAGE DISPOSAL AND THE REQUIRED CLEARANCES | | | PER SECTION 11-4.24.3. SUBMIT THE MANUF. SPECIFICATIONS | | | FOR THE SINK AND THE GARBAGE DISPOSAL THAT INDICATE ADA | | | APPROVAL. SECTION 106.1.2. | | | | | | 5. SHT P-2 A TRAP PRIMER IS REQUIRED FOR THE HUB DRAIN | | | PER SECTION 1002.4. | | | | | | 6. SHT P-2 THE WATER HEATER SHALL BE RAISED ABOVE THE | | | OUTLET OF THE HEATER PAN SO THAT THE HEATER DOES NOT | | | SIT IN THE WATER FROM THE EXPANSION VALVE WATTS #530C. | | | PLEASE INDICATE ON WATER HEATER DETAIL. | | | | | | 7. SHTS P-1 KEY NOTES #4 INDICATES THE WATER HEATER IS | | | A 40 GAL LOW BOY. PLEASE SUBMIT A DETAIL SHOWING HOW | | | THE WATER HEATER WILL BE HANGING ABOVE THE CEILING. THE | | | WEIGHT OF THE WATER HEATER WHEN FULL WILL BE OVER 375 | | | LBS AND PER SECTION 501.4 SHALL BE PROVIDED WITH ACCESS | | | FOR OBSERVATION, MAINTENANCE, SERVICING AND | | | REPLACEMENT. SECTION 106.1.2 (MORE INFORMATION | | | REQUIRED). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-03-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-03-13 |
Time |
08:42 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2009-03-13 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-02-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-02-11 |
Time |
08:38 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2009-02-11 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2009-02-11 08:46:26 | FAILED | | | | | | ADDITIONAL INFORMATION ON THE ROOFTOP A/C EQUIPMENT IS | | | REQUIRED. PLEASE PROVIDE THE HEIGHT OF THE EQUIPMENT | | | FROM THE LEVEL OF THE ROOF AND THE HEIGHT OF THE | | | EXISTING SCREEN WALL. IF THE A/C EQUIPMENT EXCEEDS THE | | | HEIGHT OF THE SCREEN WALL, THEN A LETTER APPROVING THE | | | A/C EQUIPMENT IS REQUIRED FROM THE NORTHPOINT | | | ARCHITECTURAL REVIEW COMMITTEE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|