| Plan Review Stops For Permit 09020075 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2009-09-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-09-23 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-09-23 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2009-09-23 09:02:48 | ENGINEERING PERMIT REQUIRED FOR APPROACH IN THE ROW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
N |
Date |
2009-08-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-08-18 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-08-18 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2009-08-18 14:37:30 | LANDSCAPE PLAN |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2009-08-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-08-13 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-08-13 |
Time |
09:17 |
Sent To |
Z |
|
| Notes |
| 2009-08-13 09:18:32 | REVISION, SHEET 1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2009-07-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-07-29 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-07-29 |
Time |
09:17 |
Sent To |
Z |
|
| Notes |
| 2009-07-29 09:18:16 | ****CORRECTIONS**** | | | ****REVISION, SHEET 1 OF 1**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. THE DETAIL SECTION D-D DOES NOT SPECIFY | | | HAND/GUARDRAIL HEIGHT. AS THE HEIGHT OF FINISHED FLOOR | | | IS OVER 30", A GUARDRAIL IS REQUIRED. PLEASE SPECIFY | | | HEIGHT, FBC R 311.5.1, FBC R 312.1. | | | | | | 2ND REVIEW, I WAS UNABLE TO FIND THE HEIGHT ON THE | | | PLAN. PLEASE ADVISE AS TO WHERE THIS INFORMATION CAN BE | | | FOUND OR REVISE PLAN TO INCLUDE HEIGHT AS REQUESTED. | | | | | | 2. FBC R 311.5.3.3, NOSING OF APPROXIMATELY 1" IS | | | REQUIRED. THE PLAN STATES THAT THERE IS A 1 1/2" NOSE, | | | BUT A NOSING SHOWN ON THE DETAIL SECTION D-D. PLEASE | | | INCORPORATE THE NOSING INTO THE DETAIL. PLEASE ALSO | | | PROVIDE JUSTIFICATION AS TO WHY THIS IS SPECIFIED AS 1 | | | 1/2" RATHER THAN 1". 1/2" IS 50% MORE THAN THE | | | DIMENSION SPECIFIED IN THE CODE. | | | | | | AS DISCUSSED, 1 1/2" IS NOT THE SAME AS 1" (50% | | | GREATER). ARCHITECT INCLUDED A REFERENCE ON THE PLAN | | | FBC 11 FIGURE 18. THIS IS THE ACCESSIBILITY CODE, AND | | | THE REQUIREMENT IS FOR 11" TREAD. THIS PLAN IS | | | RESIDENTIAL, 9 1/2" TREAD. IF THE TREAD SIZE IS CHANGED | | | TO 11", A 1 1/2" NOSING CAN BE CONSIDERED. WITH A 9 | | | 1/2" TREAD, THE CODE IS CLEAR THAT A 1 1/2" NOSING IS | | | NOT ACCEPTABLE. PLEASE ALSO SEE FBC 1009.3, EXCEPTION | | | 5, RESIDENTIAL STAIR NOSING TO BE NOT LESS THAN .75" | | | BUT NOT MORE THAN 1.25". PLEASE REVISE STAIR DETAIL. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2009-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-07-06 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-07-06 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2009-07-06 16:48:56 | ****CORRECTIONS**** | | | ****SUBMITTAL**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. IT IS NOT CLEAR WHY THIS WAS SUBMITTED. THE RESUB | | | SHEET STATES THAT "THE FIRST SET WAS MISPLACED BY THE | | | CITY." THE FIRST SET WAS NOT MISPLACED, IT IS IN THE | | | REVIEW PROCESS. PLEASE DO NOT SUBMIT UNNECESSARY | | | DOCUMENTS OR CLARIFY PURPOSE OF THIS "SUBMITTAL." |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2009-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-07-06 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-07-06 |
Time |
15:32 |
Sent To |
Z |
|
| Notes |
| 2009-07-06 16:30:14 | ****CORRECTIONS**** | | | ****REVISION, SHEET 1**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. THE DETAIL SECTION D-D DOES NOT SPECIFY | | | HAND/GUARDRAIL HEIGHT. AS THE HEIGHT OF FINISHED FLOOR | | | IS OVER 30", A GUARDRAIL IS REQUIRED. PLEASE SPECIFY | | | HEIGHT, FBC R 311.5.1, FBC R 312.1. | | | | | | 2. FBC R 311.5.3.3, NOSING OF APPROXIMATELY 1" IS | | | REQUIRED. THE PLAN STATES THAT THERE IS A 1 1/2" NOSE, | | | BUT A NOSING SHOWN ON THE DETAIL SECTION D-D. PLEASE | | | INCORPORATE THE NOSING INTO THE DETAIL. PLEASE ALSO | | | PROVIDE JUSTIFICATION AS TO WHY THIS IS SPECIFIED AS 1 | | | 1/2" RATHER THAN 1". 1/2" IS 50% MORE THAN THE | | | DIMENSION SPECIFIED IN THE CODE. | | | | | | 3. A HANDRAIL/GUARDRAIL IS REQUIRED AT BOTH STAIRS, BUT | | | IS SHOWN AT ONLY ONE STAIR. PLEASE PROVIDE A DETAIL FOR | | | THE SECOND STAIR. FBC R 311.5, 312.1. | | | | | | 4. THE VENTILATION REQUIREMENT WAS NOT ADDRESSED | | | (COMMENT FROM FIRST PLAN REVIEW) AND WAS THEREFORE | | | REDLINED, FBC R 408.1. AS THIS SHEET IS TO BE REVISED, | | | PLEASE INCORPORATE THIS CHANGE (VENTILATION TO BE | | | WITHIN 3' OF THE CORNERS) INTO THE PLAN. | | | | | | 5. THIS PERMIT WAS ISSUED WITH PROVISO, ACCESS REQUIRED | | | FOR UNDER-FLOOR SPACE FBC R408.3. PLEASE INDICATE | | | LOCATION. | | | | | | 6. PLEASE PROVIDE A REVISED SITE PLAN SHOWING FINAL | | | STAIR LOCATION IN RELATION TO THE HOUSE. FBC*106. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2009-05-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-05-06 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-05-06 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2009-05-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-05-01 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-05-01 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2009-05-01 16:27:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. ON "HOLD" PENDING RESPONSE FROM ARCHITECT REGARDING | | | FOUNDATION. PLEASE HAVE THE ARCHITECT CONTACT ROBERT | | | BROWN, 561-805-6652. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-04-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-04-29 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-04-29 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2009-04-29 08:59:59 | ***PROVISO*** | | | 1. FBC R 408.1 ONE VENTILATED OPENING REQUIRED WITHIN | | | 3' OF EACH CORNER | | | 2. ACCESS REQUIRED FBC R 408.3. | | | 3. SEPARATE PERMIT SHUTTERS | | | 4. TO BE COMPLIANT WITH FBC 109.3.10, IMPACT OF | | | CONSTRUCTION | | | 5. HYDROVENTS TO COMPLY WITH CITY OF WPB MUNICIPAL CODE | | | 94-546. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-04-09 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-04-09 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2009-04-09 14:41:46 | ***PROVISO*** | | | 1. FBC R 408.1 ONE VENTILATED OPENING REQUIRED WITHIN | | | 3' OF EACH CORNER | | | 2. ACCESS REQUIRED FBC R 408.3. | | | 3. SEPARATE PERMIT SHUTTERS | | | 4. TO BE COMPLIANT WITH FBC 109.3.10, IMPACT OF | | | CONSTRUCTION | | | 5. HYDROVENTS TO COMPLY WITH CITY OF WPB MUNICIPAL CODE | | | 94-546. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-10 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-03-10 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2009-03-10 13:45:55 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. VALUE HAS BEEN ADJUSTED PER ICC VALUATION TABLES, | | | PLEASE PAY FEES. FEES ARE DUE PRIOR TO REVIEWS BEING | | | COMPLETED. THE VALUE OF THE FOUNDATION ($6000) HAS BEEN | | | DEDUCTED FROM THE TOTAL (PAID ON 08120208). | | | | | | 2. PROVIDE TWO ORIGINAL SOILS INVESTIGATION REPORTS. | | | | | | 3. THE SURVEY STATES THAT THIS PROPERTY IS FLOOD ZONE | | | B. PLEASE REVISE; SURVEYOR HAS DETERMINED THAT A | | | PORTION OF THE PROPOSED STRUCTURE FALLS WITHIN FLOOD | | | ZONE A. PLEASE SEE CITY OF WEST PALM BEACH MUNICIPAL | | | CODE 94-541. AN ELEVATION CERTIFICATE INDICATING | | | PROPOSED ELEVATION IS REQUIRED. PLEASE NOTE THAT TWO | | | ADDITIONAL ELEVATION CERTIFICATES WILL BE REQUIRED | | | DURING CONSTRUCTION. THIS FORM MAY BE AVAILABLE ONLINE | | | AT HTTP://WWW.FEMA.GOV/PDF/NFIP/ELVCERT.PDF. | | | | | | 4. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS471 (ENERGY CALCS). TWO ORIGINAL SETS REQUIRED. | | | | | | 5. PLEASE PROVIDE A COPY OF THE DCA APPROVED PLAN FOR | | | THIS MODULAR BUILDING. THE PLANS SUBMITTED ARE BLANK IN | | | THE AREA INDICATED FOR STATE APPROVAL STAMPS. DCA | | | APPROVED MODULAR BUILDINGS INCLUDE A PLAN REVIEW STAMP | | | WITH THE APPROVAL NUMBER AND SIGNATURE OF THE PLAN | | | REVIEWER; A COPY OF THE ORIGINAL ENGINEERING KEPT ON | | | FILE WITH THE STATE. THIS MAY BE AVAILABLE ON THE | | | INTERNET, WWW.FLORIDABUILDING.ORG. TWO SETS REQUIRED. | | | | | | 6. IMPACT PROTECTION REQUIRED FBC R301. IF REMOVABLE | | | SHUTTERS ARE USED, PLEASE PROVIDE PRODUCT APPROVALS AND | | | COMPLETE THE SAMPLE INSTALLATION SCHEDULE (AVAILABLE IN | | | THE LOBBY OR AT HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/P | | | DF/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 7. PROVIDE FOUNDATION VENTING SPECIFICATION FBC R408.1. | | | | | | 8. APPLICATION STATES THAT THE TOTAL SQUARE FOOT AREA | | | IS 122 SF. PLEASE REVISE. | | | | | | 9. CITY OF WEST PALM BEACH MUNICIPAL CODE 94-546(E), | | | SHOW COMPLIANCE WITH ALL REQUIREMENTS. THIS SECTION IS | | | AVAILABLE ON THEI NTERNET AT WWW.MUNICODE.COM. | | | | | | 10. PLEASE SEE SHEET 1, SITE INSTALLED ITEMS AND | | | PROVIDE THE FOLLOWING: | | | | | | A. FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR THE | | | COMPONENTS & CLADDING PROVIDED BY CONTRACTOR TO JOIN | | | THE TWO SECTIONS (ROOF, SIDING). | | | | | | B. INFORMATION REGARDING THE ROOF; ITEM 17 STATES THAT | | | THE ROOF (COVERING, DRYIN AND COMPLETION) IS INSTALLED | | | AT SITE. PLEASE CONFIRM SCOPE (LETTER FROM CONTRACTOR); | | | A ROOF PERMIT WILL BE REQUIRED. | | | | | | C. EXTERIOR WALL FINISH AND SOFFIT MATERIALS; CLARIFY | | | SCOPE. (MAY BE DONE WITH A LETTER FROM CONTRACTOR) | | | | | | G CLARIFY ITEM 13 WHICH STATES THAT INSULATION UNDER | | | FLOOR IS TO BE INSTALLED ON SITE AND TO BE INDICATED ON | | | THE PLAN. THIS DOES NOT APPEAR TO BE ON THE DCA PLAN; | | | WHERE WILL THIS ITEM BE FOUND? | | | | | | E. STRUCTURAL INTERCONNECTION BETWEEN STRUCTURES; | | | PROVIDE A SPECIFICATION. | | | | | | 11. PLEASE SHOW MECHANICAL EQUIPEMENT AND PROPOSED | | | ELEVATION ON THE SITE PLAN. | | | | | | 12. PLEASE SEE FBC*109.3.10, IMPACT OF CONSTRUCTION. | | | PLEASE SHOW COMPLIANCE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU NEED ASSISTANCE | | | WITH ANY OF THE ABOVE ITEMS. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-03-27 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-03-27 |
Time |
13:00 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-10 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-10 |
Time |
08:55 |
Sent To |
Z |
|
| Notes |
| 2009-02-10 09:20:59 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} AN ELECTRICAL PERMIT IS REQUIRED FOR THE SCOPE OF | | | WORK PURPOSED. 105.1 FBC AS AMENDED. | | | | | | 2} PLEASE SUBMIT A SITE PLAN INDICATING THE LOCATION OF | | | THE METER, MAIN DISCONNECT {WITH AIC RATING}. PER | | | ARTICLE 550 NEC. | | | | | | 3} PROVIDE ELECTRICAL PLANS FOR THE WIRING OF THE A/C | | | UNIT APPLICATION # 09020078. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2009-08-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-08-13 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-08-13 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2009-08-13 09:48:41 | SENT TO RESIDENTIAL BOX R7. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-17 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-17 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2009-07-17 11:37:28 | TO SHILL'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-07-08 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-07-07 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-06-19 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-07-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-30 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-04-30 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2009-04-30 15:26:12 | TO ZONING INBOX. NEEDS ANDSCAPE REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-16 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-03-16 |
Time |
16:10 |
Sent To |
Z |
|
| Notes |
| 2009-03-16 16:11:13 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-02-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-24 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-24 |
Time |
13:06 |
Sent To |
M |
|
| Notes |
| 2009-02-24 13:07:05 | TO "SFR" "M" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-10 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-02-05 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2009-02-05 09:24:55 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
6 |
Status |
P |
Date |
2009-08-25 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-25 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-25 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2009-08-25 13:34:53 | ***LANDSCAPE REVIEW PASSED WITH PROVISO*** | | | | | | 1. SUMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST | | | OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | | UNIT COST. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
5 |
Status |
F |
Date |
2009-08-17 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-17 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-17 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2009-08-17 11:18:47 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. SOME OF THE PLANT MATERIAL SHOWN WITHIN THE PLANT | | | BEDS IS ILLEGIBLE. PLEASE CLEARLY SHOW WHAT IS PROPOSED | | | WITHIN THE PLANT BEDS. | | | | | | 2. SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST | | | OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | | UNIT COST. PLEASE NOTE THAT THE IRRIGATION COST IS | | | SEPARATE FROM THE LANDSCAPE COST AS IRRIGATION IS UNDER | | | A SEPARATE PERMIT. | | | | | | 3. THIS PLAN DOES NOT MEET XERISCAPE GUIDELINES. LIKE | | | PLANT MATERIAL WITH SIMILAR WATER AND MAINTENANCE | | | REQUIREMENTS SHALL BE GROUPED TOGETHER. USING ONE OR | | | TWO PLANTS FROM A VARIETY OF SPECIES PLANTED INTO THE | | | SAME PLANT BED IS NOT IN KEEPING WITH XERISCAPE | | | PRINCIPLES. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
2009-05-01 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-05-01 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-05-01 |
Time |
12:05 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
2009-04-28 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-04-28 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-04-28 |
Time |
12:28 |
Sent To |
PC |
|
| Notes |
| 2009-04-28 13:24:47 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPOND TO ALL LANDSCAPE COMMENTS IN WRITTEN | | | FORMAT. | | | | | | 1. PLEASE PROVIDE THE TABULATION REQUIRED TO COMPLY | | | WITH ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS, INCLUDING THE XERISCAPE POINTS. FIVE | | | POINTS WERE TAKEN FOR GRASS. FLORATAM IS NOT DROUGHT | | | TOLERANT. HOWEVER, IF THREE INCHES OF MULCH IS APPLIED, | | | TEN POINTS CAN BE TAKEN. | | | | | | 2. PURSUANT TO SECTION 94-448 (D)(2)(A-R), WHEN | | | SUBMITTING A LANDSCAPE PLAN, THE LANDSCAPE PLAN SHALL | | | INCLUDE THE ITEMS LISTED IN THIS SECTION. | | | | | | 3. ALL PLANT MATERIAL, INCLUDING EXISTING TREES, SHALL | | | BE FLORIDA #1 GRADE OR BETTER. PLACE THIS NOTE ON PLAN. | | | | | | 4. PURSUANT TO SECTION 94-442 (B)(2)(A), FOR SINGLE | | | FAMILY DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR | | | FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET | | | OF OPEN SPACE OR PORTION THEREOF. A GROUPING OF THREE | | | SABAL PALMS IS THE EQUIVALENT TO ONE SHADE TREE. A | | | TOTAL OF FIVE TREES IS REQUIRED. | | | | | | 5. PURSUANT TO SECTION 94-442 (D), PRIVATE LAND AND | | | PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK | | | SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN | | | SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS | | | SHALL BE SODDED. THIS APPLIES TO THE ENTIRE LOT, | | | INCLUDING THE RIGHT-OF-WAY. | | | | | | 6. PLEASE PROVIDE A COST ESTIMATE THAT INCLUDES THE | | | TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR. | | | | | | 7. ALL PROPOSED TREES AND PLANT MATERIAL SHALL BE | | | IDENTIFIED BY NAME AND THE QUANTITY, SIZE AND SPACING | | | SHALL BE SHOWN ON PLAN AND IN PLANT LIST. | | | | | | 8. ALL PROHIBITED PLANT MATERIAL SHALL BE REMOVED FROM | | | THE DEVELOPMENT SITE. THIS NOTE SHALL APPEAR ON THE | | | PLAN AND IT IS NOT SUBJECT TO HOMEOWNER'S APPROVAL. | | | | | | IF YOU HAVE ANY QUESITONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462, |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2009-03-25 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-03-25 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-03-25 |
Time |
15:30 |
Sent To |
PC |
|
| Notes |
| 2009-03-25 16:19:03 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPOND TO ALL LANDSCAPE COMMENTS IN WRITTEN | | | FORMAT. | | | | | | 1. PLEASE PROVIDE THE TABULATION REQUIRED TO COMPLY | | | WITH ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS, INCLUDING THE XERISCAPE POINTS. | | | | | | 2. PURSUANT TO SECTION 94-448 (D)(2)(A-R), WHEN | | | SUBMITTING A LANDSCAPE PLAN, THE LANDSCAPE PLAN SHALL | | | INCLUDE THE ITEMS LISTED IN THIS SECTION. | | | | | | 3. PURSUANT TO SECTION 94-448(D)(1), HISTORIC TREES, | | | SPECIMEN TREES, AND ANY OTHER TREES OR VEGETATION | | | LOCATED ON PROPERTY SUBJECT TO THE PROVISIONS OF THIS | | | SECTION SHALL NOT BE REMOVED, RELOCATED, OR REPLACED | | | UNLESS A TREE ALTERATION PERMIT IS OBTAINED. TREE | | | ALTERATION PERMIT APPLICATIONS SHALL BE PROVIDED BY THE | | | PLANNING AND ZONING ADMINISTRATOR OR HIS DESIGNEE. SHOW | | | ALL EXISTING TREES ON SITE (IF ANY) AND INDICATE WHICH | | | TREES WILL BE REMOVED, RELOCATED OR WILL REMAIN IN | | | PLACE. ALL PLANT MATERIAL, INCLUDING EXISTING TREES, | | | SHALL BE FLORIDA #1 GRADE OR BETTER. | | | | | | 4. PURSUANT TO SECTION 94-442 (B)(2)(A), FOR SINGLE | | | FAMILY DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR | | | FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET | | | OF OPEN SPACE OR PORTION THEREOF. FOR SINGLE FAMILY | | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | | | | | 5. PURSUANT TO SECTION 94-442 (D), PRIVATE LAND AND | | | PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK | | | SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN | | | SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS | | | SHALL BE SODDED. THIS APPLIES TO THE ENTIRE LOT, | | | INCLUDING THE RIGHT-OF-WAY. | | | | | | 6. PLEASE PROVIDE A COST ESTIMATE THAT INCLUDES THE | | | TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR. | | | | | | 7. PURSUANT TO SECTION 94-445 (4)(G)(3), AUTOMATIC | | | IRRIGATION SYSTEMS SHALL BE USED FO THE CULTIVATED | | | LANDSCAPE AREAS FOR ALL PROPERTIES. AN IRRIGATION | | | PERMIT IS REQUIRED. | | | | | | 8. ALL PROHIBITED PLANT MATERIAL SHALL BE REMOVED FROM | | | THE DEVELOPMENT SITE. | | | | | | IF YOU HAVE ANY QUESITONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462, |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-02-20 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-02-20 |
Time |
14:12 |
Sent To |
PC |
|
| Notes |
| 2009-02-20 14:18:16 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. SUBMIT A LANDSCAPE PLAN DRAWN TO SCALE THAT COMPLIES | | | WITH ALL REQUIREMENTS FOUND IN ARTICLE XIV OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE | | | XERISCAPE DESIGN OPTIONS. | | | | | | 3. THE PLANT LIST SHALL INCLUDE THE NAME, SIZE, | | | QUANTITY AND SPACING OF ALL PROPOSED PLANT MATERIAL. | | | ALL EXISTING AND PROPOSED PLANT MATERIAL SHALL BE | | | ACCURATELY DEPICTED ON THE LANDSCAPE PLAN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2009-05-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-05-01 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-05-01 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2009-05-01 15:06:04 | MECHANICAL PLANS/PERMIT REMOVED FROM MASTER PERMIT - | | | CONTR TO ADDRESS MECHANICAL COMMENTS (SEE 09020078) | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-04-01 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-04-01 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-04-01 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-02-27 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-02-27 |
Time |
09:01 |
Sent To |
P |
|
| Notes |
| 2009-02-27 09:08:38 | PLEASE SUBMIT SITE PLAN INDICATING THE LOCATION OF THE | | | CONDENSER AND CONDENSER SLAB , ALSO THE TERMINATION OF | | | THE CONDENSATE DRAIN . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-04-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-10 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-04-10 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2009-04-10 08:07:35 | RETURNED TO LUIS M. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-03-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-03-02 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-03-02 |
Time |
12:15 |
Sent To |
B1 |
|
| Notes |
| 2009-03-02 12:19:10 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SUBMIT A SITE PLAN SHOWING THE LOCATION OF THE OF | | | THE SEWER LATTERAL, THE WATER METER AND THE PIPING FOR | | | THE BUILDING SEWER AS WELL AS THE PIPING FOR THE WATER | | | SERVICE. SECTIONS 106.1.2, 601.1 & 701.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-09-21 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-09-21 |
Time |
11:41 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-08-14 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-08-14 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-08-14 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2009-08-14 08:16:33 | ***PROVISO*** | | | | | | TOP OF LANDING AT FRONT ENTRY MUST BE NO HIGHER THAN 36 | | | INCHES ABOVE GRADE. PLEASE CONTACT KELLY FREEMAN, GIS | | | PLANNER, AT 561-822-1458 WITH QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-07-30 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-07-30 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-07-30 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2009-07-30 14:24:37 | ***FAILED*** | | | | | | PLEASE PROVIDE THE DISTANCE BETWEEN THE FRONT STAIRS | | | AND THE PROPERTY LINE AS WELL AS THE HEIGHT OF THE | | | STAIRS. PLEASE NOTE, PER SEC. 94-305(B)(9), OUTSIDE | | | STAIRCASES GREATER THAN THREE FEET ABOVE GRADE SHALL BE | | | SUBJECT TO THE SETBACK REQUIREMENTS OF THE MAIN | | | STRUCTURE. BECAUSE THE PROPOSED STAIRS ARE WITHIN THE | | | FRONT SETBACK, THEY MAY NOT EXCEED THREE FEET IN | | | HEIGHT. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458 | | | WITH QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-07-07 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-07-07 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-07-07 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2009-07-07 13:22:02 | ***FAILED*** | | | | | | PLEASE PROVIDE THE DISTANCE BETWEEN THE FRONT STAIRS | | | AND THE PROPERTY LINE AS WELL AS THE HEIGHT OF THE | | | STAIRS. PLEASE NOTE, PER SEC. 94-305(B)(9), OUTSIDE | | | STAIRCASES GREATER THAN THREE FEET ABOVE GRADE SHALL BE | | | SUBJECT TO THE SETBACK REQUIREMENTS OF THE MAIN | | | STRUCTURE. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458 | | | WITH QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-02-20 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-02-20 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|