Plan Review Details - Permit 09020075
Plan Review Stops For Permit 09020075
Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status P Date 2009-09-23 Cont ID  
Sent By shill Date 2009-09-23 Time 09:02 Rev Time 0.00
Received By shill Date 2009-09-23 Time 09:02 Sent To  
Notes
2009-09-23 09:02:48ENGINEERING PERMIT REQUIRED FOR APPROACH IN THE ROW

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status N Date 2009-08-18 Cont ID  
Sent By shill Date 2009-08-18 Time 14:37 Rev Time 0.00
Received By shill Date 2009-08-18 Time 14:37 Sent To  
Notes
2009-08-18 14:37:30LANDSCAPE PLAN

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2009-08-13 Cont ID  
Sent By shill Date 2009-08-13 Time 09:17 Rev Time 0.00
Received By shill Date 2009-08-13 Time 09:17 Sent To Z
Notes
2009-08-13 09:18:32REVISION, SHEET 1
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status F Date 2009-07-29 Cont ID  
Sent By shill Date 2009-07-29 Time 09:17 Rev Time 0.00
Received By shill Date 2009-07-29 Time 09:17 Sent To Z
Notes
2009-07-29 09:18:16****CORRECTIONS****
 ****REVISION, SHEET 1 OF 1****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. THE DETAIL SECTION D-D DOES NOT SPECIFY
 HAND/GUARDRAIL HEIGHT. AS THE HEIGHT OF FINISHED FLOOR
 IS OVER 30", A GUARDRAIL IS REQUIRED. PLEASE SPECIFY
 HEIGHT, FBC R 311.5.1, FBC R 312.1.
  
 2ND REVIEW, I WAS UNABLE TO FIND THE HEIGHT ON THE
 PLAN. PLEASE ADVISE AS TO WHERE THIS INFORMATION CAN BE
 FOUND OR REVISE PLAN TO INCLUDE HEIGHT AS REQUESTED.
  
 2. FBC R 311.5.3.3, NOSING OF APPROXIMATELY 1" IS
 REQUIRED. THE PLAN STATES THAT THERE IS A 1 1/2" NOSE,
 BUT A NOSING SHOWN ON THE DETAIL SECTION D-D. PLEASE
 INCORPORATE THE NOSING INTO THE DETAIL. PLEASE ALSO
 PROVIDE JUSTIFICATION AS TO WHY THIS IS SPECIFIED AS 1
 1/2" RATHER THAN 1". 1/2" IS 50% MORE THAN THE
 DIMENSION SPECIFIED IN THE CODE.
  
 AS DISCUSSED, 1 1/2" IS NOT THE SAME AS 1" (50%
 GREATER). ARCHITECT INCLUDED A REFERENCE ON THE PLAN
 FBC 11 FIGURE 18. THIS IS THE ACCESSIBILITY CODE, AND
 THE REQUIREMENT IS FOR 11" TREAD. THIS PLAN IS
 RESIDENTIAL, 9 1/2" TREAD. IF THE TREAD SIZE IS CHANGED
 TO 11", A 1 1/2" NOSING CAN BE CONSIDERED. WITH A 9
 1/2" TREAD, THE CODE IS CLEAR THAT A 1 1/2" NOSING IS
 NOT ACCEPTABLE. PLEASE ALSO SEE FBC 1009.3, EXCEPTION
 5, RESIDENTIAL STAIR NOSING TO BE NOT LESS THAN .75"
 BUT NOT MORE THAN 1.25". PLEASE REVISE STAIR DETAIL.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2009-07-06 Cont ID  
Sent By shill Date 2009-07-06 Time 16:47 Rev Time 0.00
Received By shill Date 2009-07-06 Time 16:47 Sent To  
Notes
2009-07-06 16:48:56****CORRECTIONS****
 ****SUBMITTAL****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. IT IS NOT CLEAR WHY THIS WAS SUBMITTED. THE RESUB
 SHEET STATES THAT "THE FIRST SET WAS MISPLACED BY THE
 CITY." THE FIRST SET WAS NOT MISPLACED, IT IS IN THE
 REVIEW PROCESS. PLEASE DO NOT SUBMIT UNNECESSARY
 DOCUMENTS OR CLARIFY PURPOSE OF THIS "SUBMITTAL."

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2009-07-06 Cont ID  
Sent By shill Date 2009-07-06 Time 15:32 Rev Time 0.00
Received By shill Date 2009-07-06 Time 15:32 Sent To Z
Notes
2009-07-06 16:30:14****CORRECTIONS****
 ****REVISION, SHEET 1****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. THE DETAIL SECTION D-D DOES NOT SPECIFY
 HAND/GUARDRAIL HEIGHT. AS THE HEIGHT OF FINISHED FLOOR
 IS OVER 30", A GUARDRAIL IS REQUIRED. PLEASE SPECIFY
 HEIGHT, FBC R 311.5.1, FBC R 312.1.
  
 2. FBC R 311.5.3.3, NOSING OF APPROXIMATELY 1" IS
 REQUIRED. THE PLAN STATES THAT THERE IS A 1 1/2" NOSE,
 BUT A NOSING SHOWN ON THE DETAIL SECTION D-D. PLEASE
 INCORPORATE THE NOSING INTO THE DETAIL. PLEASE ALSO
 PROVIDE JUSTIFICATION AS TO WHY THIS IS SPECIFIED AS 1
 1/2" RATHER THAN 1". 1/2" IS 50% MORE THAN THE
 DIMENSION SPECIFIED IN THE CODE.
  
 3. A HANDRAIL/GUARDRAIL IS REQUIRED AT BOTH STAIRS, BUT
 IS SHOWN AT ONLY ONE STAIR. PLEASE PROVIDE A DETAIL FOR
 THE SECOND STAIR. FBC R 311.5, 312.1.
  
 4. THE VENTILATION REQUIREMENT WAS NOT ADDRESSED
 (COMMENT FROM FIRST PLAN REVIEW) AND WAS THEREFORE
 REDLINED, FBC R 408.1. AS THIS SHEET IS TO BE REVISED,
 PLEASE INCORPORATE THIS CHANGE (VENTILATION TO BE
 WITHIN 3' OF THE CORNERS) INTO THE PLAN.
  
 5. THIS PERMIT WAS ISSUED WITH PROVISO, ACCESS REQUIRED
 FOR UNDER-FLOOR SPACE FBC R408.3. PLEASE INDICATE
 LOCATION.
  
 6. PLEASE PROVIDE A REVISED SITE PLAN SHOWING FINAL
 STAIR LOCATION IN RELATION TO THE HOUSE. FBC*106.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2009-05-06 Cont ID  
Sent By shill Date 2009-05-06 Time 08:54 Rev Time 0.00
Received By shill Date 2009-05-06 Time 08:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2009-05-01 Cont ID  
Sent By shill Date 2009-05-01 Time 16:26 Rev Time 0.00
Received By shill Date 2009-05-01 Time 16:26 Sent To  
Notes
2009-05-01 16:27:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. ON "HOLD" PENDING RESPONSE FROM ARCHITECT REGARDING
 FOUNDATION. PLEASE HAVE THE ARCHITECT CONTACT ROBERT
 BROWN, 561-805-6652.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-04-29 Cont ID  
Sent By shill Date 2009-04-29 Time 08:58 Rev Time 0.00
Received By shill Date 2009-04-29 Time 08:58 Sent To  
Notes
2009-04-29 08:59:59***PROVISO***
 1. FBC R 408.1 ONE VENTILATED OPENING REQUIRED WITHIN
 3' OF EACH CORNER
 2. ACCESS REQUIRED FBC R 408.3.
 3. SEPARATE PERMIT SHUTTERS
 4. TO BE COMPLIANT WITH FBC 109.3.10, IMPACT OF
 CONSTRUCTION
 5. HYDROVENTS TO COMPLY WITH CITY OF WPB MUNICIPAL CODE
 94-546.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-04-09 Cont ID  
Sent By shill Date 2009-04-09 Time 14:40 Rev Time 0.00
Received By shill Date 2009-04-09 Time 11:00 Sent To  
Notes
2009-04-09 14:41:46***PROVISO***
 1. FBC R 408.1 ONE VENTILATED OPENING REQUIRED WITHIN
 3' OF EACH CORNER
 2. ACCESS REQUIRED FBC R 408.3.
 3. SEPARATE PERMIT SHUTTERS
 4. TO BE COMPLIANT WITH FBC 109.3.10, IMPACT OF
 CONSTRUCTION
 5. HYDROVENTS TO COMPLY WITH CITY OF WPB MUNICIPAL CODE
 94-546.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-03-10 Cont ID  
Sent By shill Date 2009-03-10 Time 13:41 Rev Time 0.00
Received By shill Date 2009-03-10 Time 13:41 Sent To  
Notes
2009-03-10 13:45:55****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. VALUE HAS BEEN ADJUSTED PER ICC VALUATION TABLES,
 PLEASE PAY FEES. FEES ARE DUE PRIOR TO REVIEWS BEING
 COMPLETED. THE VALUE OF THE FOUNDATION ($6000) HAS BEEN
 DEDUCTED FROM THE TOTAL (PAID ON 08120208).
  
 2. PROVIDE TWO ORIGINAL SOILS INVESTIGATION REPORTS.
  
 3. THE SURVEY STATES THAT THIS PROPERTY IS FLOOD ZONE
 B. PLEASE REVISE; SURVEYOR HAS DETERMINED THAT A
 PORTION OF THE PROPOSED STRUCTURE FALLS WITHIN FLOOD
 ZONE A. PLEASE SEE CITY OF WEST PALM BEACH MUNICIPAL
 CODE 94-541. AN ELEVATION CERTIFICATE INDICATING
 PROPOSED ELEVATION IS REQUIRED. PLEASE NOTE THAT TWO
 ADDITIONAL ELEVATION CERTIFICATES WILL BE REQUIRED
 DURING CONSTRUCTION. THIS FORM MAY BE AVAILABLE ONLINE
 AT HTTP://WWW.FEMA.GOV/PDF/NFIP/ELVCERT.PDF.
  
 4. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 FS471 (ENERGY CALCS). TWO ORIGINAL SETS REQUIRED.
  
 5. PLEASE PROVIDE A COPY OF THE DCA APPROVED PLAN FOR
 THIS MODULAR BUILDING. THE PLANS SUBMITTED ARE BLANK IN
 THE AREA INDICATED FOR STATE APPROVAL STAMPS. DCA
 APPROVED MODULAR BUILDINGS INCLUDE A PLAN REVIEW STAMP
 WITH THE APPROVAL NUMBER AND SIGNATURE OF THE PLAN
 REVIEWER; A COPY OF THE ORIGINAL ENGINEERING KEPT ON
 FILE WITH THE STATE. THIS MAY BE AVAILABLE ON THE
 INTERNET, WWW.FLORIDABUILDING.ORG. TWO SETS REQUIRED.
  
 6. IMPACT PROTECTION REQUIRED FBC R301. IF REMOVABLE
 SHUTTERS ARE USED, PLEASE PROVIDE PRODUCT APPROVALS AND
 COMPLETE THE SAMPLE INSTALLATION SCHEDULE (AVAILABLE IN
 THE LOBBY OR AT HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/P
 DF/SCHEDULE_FOR_INSTALLATION.PDF
  
 7. PROVIDE FOUNDATION VENTING SPECIFICATION FBC R408.1.
  
 8. APPLICATION STATES THAT THE TOTAL SQUARE FOOT AREA
 IS 122 SF. PLEASE REVISE.
  
 9. CITY OF WEST PALM BEACH MUNICIPAL CODE 94-546(E),
 SHOW COMPLIANCE WITH ALL REQUIREMENTS. THIS SECTION IS
 AVAILABLE ON THEI NTERNET AT WWW.MUNICODE.COM.
  
 10. PLEASE SEE SHEET 1, SITE INSTALLED ITEMS AND
 PROVIDE THE FOLLOWING:
  
 A. FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR THE
 COMPONENTS & CLADDING PROVIDED BY CONTRACTOR TO JOIN
 THE TWO SECTIONS (ROOF, SIDING).
  
 B. INFORMATION REGARDING THE ROOF; ITEM 17 STATES THAT
 THE ROOF (COVERING, DRYIN AND COMPLETION) IS INSTALLED
 AT SITE. PLEASE CONFIRM SCOPE (LETTER FROM CONTRACTOR);
 A ROOF PERMIT WILL BE REQUIRED.
  
 C. EXTERIOR WALL FINISH AND SOFFIT MATERIALS; CLARIFY
 SCOPE. (MAY BE DONE WITH A LETTER FROM CONTRACTOR)
  
 G CLARIFY ITEM 13 WHICH STATES THAT INSULATION UNDER
 FLOOR IS TO BE INSTALLED ON SITE AND TO BE INDICATED ON
 THE PLAN. THIS DOES NOT APPEAR TO BE ON THE DCA PLAN;
 WHERE WILL THIS ITEM BE FOUND?
  
 E. STRUCTURAL INTERCONNECTION BETWEEN STRUCTURES;
 PROVIDE A SPECIFICATION.
  
 11. PLEASE SHOW MECHANICAL EQUIPEMENT AND PROPOSED
 ELEVATION ON THE SITE PLAN.
  
 12. PLEASE SEE FBC*109.3.10, IMPACT OF CONSTRUCTION.
 PLEASE SHOW COMPLIANCE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU NEED ASSISTANCE
 WITH ANY OF THE ABOVE ITEMS.
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-03-27 Cont ID  
Sent By btrobaug Date 2009-03-27 Time 13:12 Rev Time 0.00
Received By btrobaug Date 2009-03-27 Time 13:00 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-02-10 Cont ID  
Sent By btrobaug Date 2009-02-10 Time 09:21 Rev Time 0.00
Received By btrobaug Date 2009-02-10 Time 08:55 Sent To Z
Notes
2009-02-10 09:20:59 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} AN ELECTRICAL PERMIT IS REQUIRED FOR THE SCOPE OF
 WORK PURPOSED. 105.1 FBC AS AMENDED.
  
 2} PLEASE SUBMIT A SITE PLAN INDICATING THE LOCATION OF
 THE METER, MAIN DISCONNECT {WITH AIC RATING}. PER
 ARTICLE 550 NEC.
  
 3} PROVIDE ELECTRICAL PLANS FOR THE WIRING OF THE A/C
 UNIT APPLICATION # 09020078.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2009-08-13 Cont ID  
Sent By jgomez Date 2009-08-13 Time 09:48 Rev Time 0.00
Received By jgomez Date 2009-08-13 Time 09:44 Sent To  
Notes
2009-08-13 09:48:41SENT TO RESIDENTIAL BOX R7.

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-07-17 Cont ID  
Sent By kstevens Date 2009-07-17 Time 11:37 Rev Time 0.00
Received By kstevens Date 2009-07-17 Time 11:37 Sent To  
Notes
2009-07-17 11:37:28TO SHILL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-07-08 Cont ID  
Sent By mcruz Date 2009-07-07 Time 11:07 Rev Time 0.00
Received By mcruz Date 2009-06-19 Time 11:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-07-08 Cont ID  
Sent By rregueir Date 2009-04-30 Time 15:26 Rev Time 0.00
Received By mcruz Date 2009-04-30 Time 15:25 Sent To  
Notes
2009-04-30 15:26:12TO ZONING INBOX. NEEDS ANDSCAPE REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-03-16 Cont ID  
Sent By shill Date 2009-03-16 Time 16:10 Rev Time 0.00
Received By shill Date 2009-03-16 Time 16:10 Sent To Z
Notes
2009-03-16 16:11:13TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-02-24 Cont ID  
Sent By adarroug Date 2009-02-24 Time 13:06 Rev Time 0.00
Received By adarroug Date 2009-02-24 Time 13:06 Sent To M
Notes
2009-02-24 13:07:05TO "SFR" "M" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-03-10 Cont ID  
Sent By shill Date 2009-03-10 Time 14:27 Rev Time 0.00
Received By shill Date 2009-02-05 Time 09:24 Sent To  
Notes
2009-02-05 09:24:55TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 6 Status P Date 2009-08-25 Cont ID  
Sent By rkussner Date 2009-08-25 Time 13:32 Rev Time 0.00
Received By rkussner Date 2009-08-25 Time 13:32 Sent To  
Notes
2009-08-25 13:34:53***LANDSCAPE REVIEW PASSED WITH PROVISO***
  
 1. SUMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST
 OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO
 UNIT COST.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 5 Status F Date 2009-08-17 Cont ID  
Sent By rkussner Date 2009-08-17 Time 11:05 Rev Time 0.00
Received By rkussner Date 2009-08-17 Time 10:18 Sent To  
Notes
2009-08-17 11:18:47***LANDSCAPE REVIEW FAILED***
  
 1. SOME OF THE PLANT MATERIAL SHOWN WITHIN THE PLANT
 BEDS IS ILLEGIBLE. PLEASE CLEARLY SHOW WHAT IS PROPOSED
 WITHIN THE PLANT BEDS.
  
 2. SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST
 OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO
 UNIT COST. PLEASE NOTE THAT THE IRRIGATION COST IS
 SEPARATE FROM THE LANDSCAPE COST AS IRRIGATION IS UNDER
 A SEPARATE PERMIT.
  
 3. THIS PLAN DOES NOT MEET XERISCAPE GUIDELINES. LIKE
 PLANT MATERIAL WITH SIMILAR WATER AND MAINTENANCE
 REQUIREMENTS SHALL BE GROUPED TOGETHER. USING ONE OR
 TWO PLANTS FROM A VARIETY OF SPECIES PLANTED INTO THE
 SAME PLANT BED IS NOT IN KEEPING WITH XERISCAPE
 PRINCIPLES.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  

Review Stop L LANDSCAPING
Rev No 4 Status P Date 2009-05-01 Cont ID  
Sent By rkussner Date 2009-05-01 Time 12:05 Rev Time 0.00
Received By rkussner Date 2009-05-01 Time 12:05 Sent To PC
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 3 Status F Date 2009-04-28 Cont ID  
Sent By rkussner Date 2009-04-28 Time 12:28 Rev Time 0.00
Received By rkussner Date 2009-04-28 Time 12:28 Sent To PC
Notes
2009-04-28 13:24:47***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO ALL LANDSCAPE COMMENTS IN WRITTEN
 FORMAT.
  
 1. PLEASE PROVIDE THE TABULATION REQUIRED TO COMPLY
 WITH ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS, INCLUDING THE XERISCAPE POINTS. FIVE
 POINTS WERE TAKEN FOR GRASS. FLORATAM IS NOT DROUGHT
 TOLERANT. HOWEVER, IF THREE INCHES OF MULCH IS APPLIED,
 TEN POINTS CAN BE TAKEN.
  
 2. PURSUANT TO SECTION 94-448 (D)(2)(A-R), WHEN
 SUBMITTING A LANDSCAPE PLAN, THE LANDSCAPE PLAN SHALL
 INCLUDE THE ITEMS LISTED IN THIS SECTION.
  
 3. ALL PLANT MATERIAL, INCLUDING EXISTING TREES, SHALL
 BE FLORIDA #1 GRADE OR BETTER. PLACE THIS NOTE ON PLAN.
  
 4. PURSUANT TO SECTION 94-442 (B)(2)(A), FOR SINGLE
 FAMILY DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR
 FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET
 OF OPEN SPACE OR PORTION THEREOF. A GROUPING OF THREE
 SABAL PALMS IS THE EQUIVALENT TO ONE SHADE TREE. A
 TOTAL OF FIVE TREES IS REQUIRED.
  
 5. PURSUANT TO SECTION 94-442 (D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED. THIS APPLIES TO THE ENTIRE LOT,
 INCLUDING THE RIGHT-OF-WAY.
  
 6. PLEASE PROVIDE A COST ESTIMATE THAT INCLUDES THE
 TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR.
  
 7. ALL PROPOSED TREES AND PLANT MATERIAL SHALL BE
 IDENTIFIED BY NAME AND THE QUANTITY, SIZE AND SPACING
 SHALL BE SHOWN ON PLAN AND IN PLANT LIST.
  
 8. ALL PROHIBITED PLANT MATERIAL SHALL BE REMOVED FROM
 THE DEVELOPMENT SITE. THIS NOTE SHALL APPEAR ON THE
 PLAN AND IT IS NOT SUBJECT TO HOMEOWNER'S APPROVAL.
  
 IF YOU HAVE ANY QUESITONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462,

Review Stop L LANDSCAPING
Rev No 2 Status F Date 2009-03-25 Cont ID  
Sent By rkussner Date 2009-03-25 Time 15:31 Rev Time 0.00
Received By rkussner Date 2009-03-25 Time 15:30 Sent To PC
Notes
2009-03-25 16:19:03***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO ALL LANDSCAPE COMMENTS IN WRITTEN
 FORMAT.
  
 1. PLEASE PROVIDE THE TABULATION REQUIRED TO COMPLY
 WITH ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS, INCLUDING THE XERISCAPE POINTS.
  
 2. PURSUANT TO SECTION 94-448 (D)(2)(A-R), WHEN
 SUBMITTING A LANDSCAPE PLAN, THE LANDSCAPE PLAN SHALL
 INCLUDE THE ITEMS LISTED IN THIS SECTION.
  
 3. PURSUANT TO SECTION 94-448(D)(1), HISTORIC TREES,
 SPECIMEN TREES, AND ANY OTHER TREES OR VEGETATION
 LOCATED ON PROPERTY SUBJECT TO THE PROVISIONS OF THIS
 SECTION SHALL NOT BE REMOVED, RELOCATED, OR REPLACED
 UNLESS A TREE ALTERATION PERMIT IS OBTAINED. TREE
 ALTERATION PERMIT APPLICATIONS SHALL BE PROVIDED BY THE
 PLANNING AND ZONING ADMINISTRATOR OR HIS DESIGNEE. SHOW
 ALL EXISTING TREES ON SITE (IF ANY) AND INDICATE WHICH
 TREES WILL BE REMOVED, RELOCATED OR WILL REMAIN IN
 PLACE. ALL PLANT MATERIAL, INCLUDING EXISTING TREES,
 SHALL BE FLORIDA #1 GRADE OR BETTER.
  
 4. PURSUANT TO SECTION 94-442 (B)(2)(A), FOR SINGLE
 FAMILY DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR
 FRUIT TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET
 OF OPEN SPACE OR PORTION THEREOF. FOR SINGLE FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
  
 5. PURSUANT TO SECTION 94-442 (D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED. THIS APPLIES TO THE ENTIRE LOT,
 INCLUDING THE RIGHT-OF-WAY.
  
 6. PLEASE PROVIDE A COST ESTIMATE THAT INCLUDES THE
 TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR.
  
 7. PURSUANT TO SECTION 94-445 (4)(G)(3), AUTOMATIC
 IRRIGATION SYSTEMS SHALL BE USED FO THE CULTIVATED
 LANDSCAPE AREAS FOR ALL PROPERTIES. AN IRRIGATION
 PERMIT IS REQUIRED.
  
 8. ALL PROHIBITED PLANT MATERIAL SHALL BE REMOVED FROM
 THE DEVELOPMENT SITE.
  
 IF YOU HAVE ANY QUESITONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462,

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-02-20 Cont ID  
Sent By rkussner Date 2009-02-20 Time 14:13 Rev Time 0.00
Received By rkussner Date 2009-02-20 Time 14:12 Sent To PC
Notes
2009-02-20 14:18:16***LANDSCAPE REVIEW FAILED***
  
 1. SUBMIT A LANDSCAPE PLAN DRAWN TO SCALE THAT COMPLIES
 WITH ALL REQUIREMENTS FOUND IN ARTICLE XIV OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 3. THE PLANT LIST SHALL INCLUDE THE NAME, SIZE,
 QUANTITY AND SPACING OF ALL PROPOSED PLANT MATERIAL.
 ALL EXISTING AND PROPOSED PLANT MATERIAL SHALL BE
 ACCURATELY DEPICTED ON THE LANDSCAPE PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2009-05-01 Cont ID  
Sent By shill Date 2009-05-01 Time 15:05 Rev Time 0.00
Received By shill Date 2009-05-01 Time 15:05 Sent To  
Notes
2009-05-01 15:06:04MECHANICAL PLANS/PERMIT REMOVED FROM MASTER PERMIT -
 CONTR TO ADDRESS MECHANICAL COMMENTS (SEE 09020078)
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-04-01 Cont ID  
Sent By hmoser Date 2009-04-01 Time 13:54 Rev Time 0.00
Received By hmoser Date 2009-04-01 Time 13:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-02-27 Cont ID  
Sent By hmoser Date 2009-02-27 Time 09:01 Rev Time 0.00
Received By hmoser Date 2009-02-27 Time 09:01 Sent To P
Notes
2009-02-27 09:08:38PLEASE SUBMIT SITE PLAN INDICATING THE LOCATION OF THE
 CONDENSER AND CONDENSER SLAB , ALSO THE TERMINATION OF
 THE CONDENSATE DRAIN .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-04-10 Cont ID  
Sent By kstevens Date 2009-04-10 Time 08:05 Rev Time 0.00
Received By kstevens Date 2009-04-10 Time 08:05 Sent To  
Notes
2009-04-10 08:07:35RETURNED TO LUIS M.

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-03-02 Cont ID  
Sent By kstevens Date 2009-03-02 Time 12:15 Rev Time 0.00
Received By kstevens Date 2009-03-02 Time 12:15 Sent To B1
Notes
2009-03-02 12:19:10DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SUBMIT A SITE PLAN SHOWING THE LOCATION OF THE OF
 THE SEWER LATTERAL, THE WATER METER AND THE PIPING FOR
 THE BUILDING SEWER AS WELL AS THE PIPING FOR THE WATER
 SERVICE. SECTIONS 106.1.2, 601.1 & 701.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 5 Status P Date 2009-09-21 Cont ID  
Sent By kdfreema Date 2009-09-21 Time 11:41 Rev Time 0.00
Received By kdfreema Date 2009-09-21 Time 11:41 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2009-08-14 Cont ID  
Sent By kdfreema Date 2009-08-14 Time 08:15 Rev Time 0.00
Received By kdfreema Date 2009-08-14 Time 08:15 Sent To  
Notes
2009-08-14 08:16:33***PROVISO***
  
 TOP OF LANDING AT FRONT ENTRY MUST BE NO HIGHER THAN 36
 INCHES ABOVE GRADE. PLEASE CONTACT KELLY FREEMAN, GIS
 PLANNER, AT 561-822-1458 WITH QUESTIONS.

Review Stop Z ZONING
Rev No 3 Status F Date 2009-07-30 Cont ID  
Sent By kdfreema Date 2009-07-30 Time 14:24 Rev Time 0.00
Received By kdfreema Date 2009-07-30 Time 14:24 Sent To  
Notes
2009-07-30 14:24:37***FAILED***
  
 PLEASE PROVIDE THE DISTANCE BETWEEN THE FRONT STAIRS
 AND THE PROPERTY LINE AS WELL AS THE HEIGHT OF THE
 STAIRS. PLEASE NOTE, PER SEC. 94-305(B)(9), OUTSIDE
 STAIRCASES GREATER THAN THREE FEET ABOVE GRADE SHALL BE
 SUBJECT TO THE SETBACK REQUIREMENTS OF THE MAIN
 STRUCTURE. BECAUSE THE PROPOSED STAIRS ARE WITHIN THE
 FRONT SETBACK, THEY MAY NOT EXCEED THREE FEET IN
 HEIGHT.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458
 WITH QUESTIONS.

Review Stop Z ZONING
Rev No 2 Status F Date 2009-07-07 Cont ID  
Sent By kdfreema Date 2009-07-07 Time 13:22 Rev Time 0.00
Received By kdfreema Date 2009-07-07 Time 13:22 Sent To  
Notes
2009-07-07 13:22:02***FAILED***
  
 PLEASE PROVIDE THE DISTANCE BETWEEN THE FRONT STAIRS
 AND THE PROPERTY LINE AS WELL AS THE HEIGHT OF THE
 STAIRS. PLEASE NOTE, PER SEC. 94-305(B)(9), OUTSIDE
 STAIRCASES GREATER THAN THREE FEET ABOVE GRADE SHALL BE
 SUBJECT TO THE SETBACK REQUIREMENTS OF THE MAIN
 STRUCTURE.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458
 WITH QUESTIONS.

Review Stop Z ZONING
Rev No 1 Status P Date 2009-02-20 Cont ID  
Sent By kdfreema Date 2009-02-20 Time 13:29 Rev Time 0.00
Received By kdfreema Date 2009-02-20 Time 13:29 Sent To  
Notes
***NONE***