Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-03-26 Cont ID  
Sent By rmcdouga Date 2009-03-26 Time 15:57 Rev Time 0.00
Received By rmcdouga Date 2009-03-26 Time 15:57 Sent To  
Notes
2009-03-26 15:59:39OWNER BROUGHT IN MISSING ELECTRICAL SHEET.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-03-26 Cont ID  
Sent By rmcdouga Date 2009-03-26 Time 09:51 Rev Time 0.00
Received By rmcdouga Date 2009-03-26 Time 09:51 Sent To  
Notes
2009-03-26 09:52:24ONE PLAN SET MISSING THE ELECTRICAL SHEET

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-02-23 Cont ID  
Sent By rmcdouga Date 2009-02-23 Time 08:45 Rev Time 0.00
Received By rmcdouga Date 2009-02-23 Time 08:15 Sent To  
Notes
2009-02-23 08:45:052004 FBC W/2007 REVISIONS
 ENCLOSE CARPORT FOR STORAGE
  
 DENIED BY BUILDING
  
 1) SHOW COMPLIANCE WITH R703.6.3
 WHERE CEMENT PLASTER (STUCCO) IS TO BE APPLIED TO LATH
 OVER FRAME CONSTRUCTION, MEASURES SHALL BE TAKEN TO
 PREVENT BONDING BETWEEN THE CEMENT PLASTER AND THE
 WATER-RESISTIVE BARRIER. A BOND BREAK SHALL BE PROVIDED
 BETWEEN THE WATER-RESISTIVE BARRIER AND THE CEMENT
 PLASTER (STUCCO) CONSISTING OF ONE OF THE FOLLOWING:
 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER
 MATERIAL; OR
 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER
 OVER AN APPROVED PLASTIC HOUSE WRAP; OR
 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN
 ACCORDANCE WITH THE MANUFACTURER???S INSTALLATION
 INSTRUCTIONS.
  
 2) SHOW COMPLIANCE WITH FBC RESIDENTIAL SECTION 704
 INSPECTION FOR TERMITES
 IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM).
  
 3) R404.1.6 HEIGHT ABOVE FINISHED GRADE.
 CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND
 ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT
 ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY
 VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM)
 ELSEWHERE.
  
 4) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 SIMPSON CONNECTORS OR SPECIFY THE STATE PRODUCT
 APPROVAL FL #S ON THE PLANS. DCA RULE 9B-72.
  
 5) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 6) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED. PH 561-233-5025
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-02-23 Cont ID  
Sent By rmcdouga Date 2009-02-23 Time 08:54 Rev Time 0.00
Received By rmcdouga Date 2009-02-05 Time 12:27 Sent To  
Notes
2009-02-23 08:56:15OK PER BILL TROBAUGH ON 2/5/09.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-03-18 Cont ID  
Sent By adarroug Date 2009-03-18 Time 16:44 Rev Time 0.00
Received By adarroug Date 2009-03-18 Time 16:44 Sent To Z
Notes
2009-03-18 16:44:58TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-02-23 Cont ID  
Sent By rmcdouga Date 2009-02-23 Time 09:02 Rev Time 0.00
Received By rmcdouga Date 2009-02-23 Time 09:02 Sent To  
Notes
2009-02-04 16:42:04SENT TO ZONING INBOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2009-02-23 Cont ID  
Sent By rmcdouga Date 2009-02-23 Time 09:02 Rev Time 0.00
Received By rmcdouga Date 2009-02-23 Time 09:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2009-02-23 Cont ID  
Sent By rmcdouga Date 2009-02-23 Time 09:02 Rev Time 0.00
Received By rmcdouga Date 2009-02-23 Time 09:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2009-03-23 Cont ID  
Sent By mcruz Date 2009-03-23 Time 08:59 Rev Time 0.00
Received By mcruz Date 2009-03-23 Time 08:55 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2009-02-19 Cont ID  
Sent By mcruz Date 2009-02-19 Time 13:41 Rev Time 0.00
Received By mcruz Date 2009-02-19 Time 13:40 Sent To I
Notes
2009-02-19 13:40:57PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved