| Plan Review Stops For Permit 09010481 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-10-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-10-19 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-10-19 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-09-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-09-09 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-09-09 |
Time |
11:44 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-24 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-03-24 |
Time |
10:36 |
Sent To |
P |
|
| Notes |
| 2009-03-24 10:40:59 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | COMMENT FROM PREVIOUS LIST: | | | | | | 1. FS471, THE ENGINEER'S SEAL IS TO BE LEGIBLE. PLEASE | | | HAVE THE ENGINEER RE-SEAL THE SHEETS AS DISCUSSED. | | | | | | NEW COMMENTS: | | | | | | 2. TWO COMPLETE SETS OF ORIGINAL DOCUMENTS REQUIRED FOR | | | PERMIT ISSUANCE. NOTE THE FOLLOWING: | | | | | | A. ONLY ONE SET OF PLANS PREPARED BY DOUGLAS RUTH | | | ASSOCIATES WAS SUBMITTED. THE ONE SET WAS NOT SIGNED | | | AND SEALED. TWO ORIGINAL SIGNED, SEALED, DATED SETS | | | REQUIRED. | | | | | | B. TWO ADDITIONAL SETS OF PLANS PREPARED BY JOHN HALEY, | | | PE WERE SUBMITTED. PLEASE REMOVE FROM THE PACKAGE; KEEP | | | THE TWO ORIGINALS IN THE PERMIT PACKAGE. | | | | | | 3. INFORMATIONAL ONLY; THE DUMPSTER GATES CANNOT | | | ENCROACH THE PROPERTY LINE FBC3202.2. THE PERMIT WILL | | | BE ISSUED WITH PROVISO/REDLINE (NO CHANGE TO PLANS | | | NECESSARY). | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-02-27 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-02-27 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2009-02-27 13:20:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. FS471, THE ENGINEER'S SEAL IS TO BE LEGIBLE. PLEASE | | | HAVE THE ENGINEER RE-SEAL THE SHEETS AS DISCUSSED. | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2009-09-03 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2009-09-03 |
Time |
08:26 |
Rev Time |
6.00 |
| Received By |
mgonzale |
Date |
2009-09-03 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2009-09-03 08:25:55 | 09/03/09 PASSED WITH PROVISOS | | | | | | REVIEW FOR STORMWATER ELEMENTS AT 233 WENNONAH PLACE | | | | | | #1 STORM CALCULATIONS DATED 09/02/09 HAVE BEEN RECEIVED | | | AND APPROVED. | | | CONTRACTOR SHALL BUILD THE PARKING AREA BASED ON THE | | | CALCULATIONS SUPPLIED AND REVISE | | | THE AS-BUILT PLAN ACCORDINGLY. (CALCS ARE ATTACHED TO | | | THE PLAN) | | | | | | #2 SHEET ONE DOES NOT AGREE WITH THE PLAN SHOWN ON SHT | | | 2 A (NO HANDICAP PARKING SHOWN) | | | ( CONTRACTOR NEEDS TO BUILD AS PER CITY APPROVED SITE | | | PLAN.) | | | | | | CONTRACTOR SHALL BE RESPONSIBLE FOR THIS CORRECTION | | | DURING CONSTRUCTION: | | | | | | #1 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | PRECAST INLET TYPE "C" (OPTION) DETAIL NEEDS TO SHOW OR | | | STATE THAT ROCK UNDER STRUCTURE MUST BE WRAPPED IN | | | FILTER FABRIC | | | #2 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | EXFILTRATION TRENCH DETAIL (OPTION) | | | REVISE NOTE #2 TO INCLUDE "BOTTOM" ALSO. | | | #3 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | ADD TO 12"X12" SUMP A NOTE ADDING SS HARDWARE CLOTH | | | (MESH) AT SUMP ENTRY POINT. | | | #4 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | REVISE NOTE #2 TO INCLUDE "BOTTOM" ALSO. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF ANY FURTHER QUESTIONS | | | OR CONCERN. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2009-08-13 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2009-08-13 |
Time |
09:14 |
Rev Time |
4.00 |
| Received By |
mgonzale |
Date |
2009-08-13 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2009-08-13 09:14:15 | | | | ENGINEERING PREVIOUSLY LOOKED AT PLANS FOR RIGHT OF WAY | | | ELEMENTS" | | | | | | 08/12/09 | | | REVIEW FOR STORMWATER ELEMENTS AT 233 WENNONAH PLACE | | | STORM WATER CALCULATION WHERE RECEIVED 08/06/09 VIA FAX | | | FROM MR HALEY AS REQUESTED TO PROCEED WITH REVIEW. | | | COMMENTS TO JOHN HALEY, ENGINEER OF RECORD | | | #1 DISCHARGE FROM SITE BEGINS AT ELEV 9.50 (CALCS SHOW | | | AT ELEV 10.61) | | | #2 PROVIDE 100 YEAR STAGE VS BUILDING FINISH FLOOR | | | ELEVATION. | | | #3 PROVIDE PRE CONDITIONS VS POST CONDITION | | | CALCULATIONS. | | | #4 SHEET ONE DOES NOT AGREE WITH THE PLAN SHOWN ON SHT | | | 2 A (NO HANDICAP PARKING SHOWN) | | | #5 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | PRECAST INLET TYPE "C" (OPTION) DETAIL NEEDS TO SHOW OR | | | STATE THAT ROCK UNDER STRUCTURE MUST BE WRAPPED IN | | | FILTER FABRIC | | | #6 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | EXFILTRATION TRENCH DETAIL (OPTION) | | | REVISE NOTE #2 TO INCLUDE "BOTTOM" ALSO. | | | #7 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | ADD TO 12"X12" SUMP A NOTE ADDING SS HARDWARE CLOTH | | | (MESH) AT SUMP ENTRY POINT. | | | #8 SHEET 2B PAVING AND DRAINAGE DETAILS: | | | REVISE NOTE #2 TO INCLUDE "BOTTOM" ALSO. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2009-02-27 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2009-02-27 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2009-02-27 |
Time |
|
Sent To |
|
|
| Notes |
| 2009-02-27 09:53:10 | **** PASSED **** | | | | | | ROW PERMIT IS REQUIRED. | | | CONTACT CWPB ENGINEERING (561) 494-1040 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-10-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-13 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-10-13 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2009-10-13 14:23:39 | LANDSCAPE RESUBMITTAL, PUT IN ZONING BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-07-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-24 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-24 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2009-07-24 16:34:45 | TO Z INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-09 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-09 |
Time |
10:35 |
Sent To |
Z |
|
| Notes |
| 2009-03-09 10:36:10 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-02-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-13 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-13 |
Time |
16:52 |
Sent To |
ENG |
|
| Notes |
| 2009-02-13 16:52:39 | TO "ENG" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-03-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-02-27 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-02-02 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2009-02-02 10:42:21 | TO "Z" BOX |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2009-10-15 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-10-15 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-10-15 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-03 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-03 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2009-08-03 12:27:17 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. REPEAT COMMENT: PLEASE RESPOND TO ALL COMMENTS IN | | | WRITTEN FORMAT. | | | | | | 2. REPEAT COMMENT: THE SITE AND PAVING AND DRAINAGE | | | PLAN ARE INCONSISTENT REGARDING THE NORTH END OF THE | | | PARKING LOT, ADJACENT TO THE DUMPSTER ENCLOSURE. THE | | | HANDICAP SPACE AND MANERUVERING ARE ARE DIFFERENT IN | | | THIS SUBMITTAL, AS WELL. ALL PLANS MUST BE CONSISTENT. | | | | | | 3. REPEAT COMMENT: THE PROPOSED DOUBLE SIDED CARSTOPS | | | ARE NOT PERMITTED BY CITY CODE. THEY MUST BE ANGLED ON | | | ONLY ONE SIDE. | | | | | | 4. PLEASE PROVIDE STANDARD CITY APPROVED STRIPING | | | DETAIL. | | | | | | 5. ON THE LANDSCAPE PLAN, PLEASE SHOW ANY OVERHEAD | | | LINES, UTIITIES, EASEMENTS OR ANYTHING ELSE THAT MAY | | | INTERFERE WITH THE PROPOSED LANDSCAPING. THE APPLICANT | | | SHALL ABIDE BY THE GUIDELINES SETFORTH BY FPL REGARDING | | | TREE LOCATIONS IN CLOSE PROXIMITY TO OVERHEAD LINES. | | | PLEASE REFER TO FPL'S 'PLANT THE RIGHT TREE IN THE | | | RIGHT PLACE' FOR MORE INFORMATION. | | | | | | 6. BASED UPON THE LANDSCAPE CALCULATIONS PROVIDED, | | | THERE ARE LESS TREES PROVIDED AS COMPARED TO WHAT IS | | | REQUIRED. PLEASE CLARFIY. | | | | | | 7. IN KEEPING WITH XERISCAPE GUIDELINES, THE PROPOSED | | | SABAL PALMS SHALL BE INCORPORATED INTO PLANT BEDS, | | | INSTEAD OF SOD. | | | | | | 8. THE SYMBOL 'PP' WAS USED ON THE PLAN, BUT THERE IS | | | NO REFERENCE TO THAT SYMBOL ON THE PLANT LEGEND. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-03-19 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-03-19 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-03-19 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2009-03-19 10:21:37 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. PLEASE RESPOND TO ALL COMMENTS IN WRITTEN FORMAT. | | | | | | 2. THE SITE PLAN AND PAVING AND DRAINAGE PLAN ARE | | | INCONSISTENT REGARDING THE NORTH END OF THE PARKING | | | LOT, ADJACENT TO THE DUMPSTER ENCLOSURE. ALL PLANS MUST | | | BE CONSISTENT. | | | | | | 3. THE PROPOSED DOUBLE SIDED CARSTOPS ARE NOT PERMITTED | | | BY CITY CODE. THEY MUST BE ANGLED ON ONLY ONE SIDE. | | | | | | 4. PLEASE PROVIDE SOD AND IRRIGATION IN THE | | | RIGHT-OF-WAY ADJACENT TO WENONA PLACE. | | | | | | 5. IN ADDITION TO THE TREES, ALL SHRUBS SHALL BE | | | PLANTED AT OR SLIGHTLY ABOVE GRADE. MULCH SHALL BE | | | APPLIED TO A DEPTH OF (3) INCHES OUTSIDE OF THE ROOT | | | BALL WITH LESS THAN (1) INCH OF MULCH SHALL BE APPLIES | | | OVER THE ROOTBALL. | | | | | | 6. SILT FENCING IS SHOWN ON THE SITE PLAN. A FENCE IS | | | SHOWN ON THE LANDSCAPE PLAN. UNLESS THIS IS A PERMANENT | | | FENCE, IT SHOULD NOT BE SHOWN ON THE LANDSCAPE PLAN. IF | | | IT IS A PERMANENT FENCE, PLEASE PROVIDE A DETAIL. IN | | | ADDIITION, IT MUST BE PLACED ALONG THE INTERIOR | | | PERIMETER OF THE LANDSCAPE SETBACK ACJACENT TO WENONAH | | | PLACE. | | | | | | 7. PLEASE PROVIDE THE TABULATION NECESSARY TO | | | DEMONSTRATE COMPLIENCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, IINCLUDING THE | | | XERISCAPE POINTS. | | | | | | 8. PLEASE SHOW THE PLANT BED LINES FOR ALL PLANTING | | | AREAS. | | | | | | 9. THE HEDGE BETWEEN THE PARKING LOT AND BUILDING IS | | | NOT REQUIRED. INSTEAD, TIERED PLANTING SHALL BE | | | INSTALLED ALONG THE SIDEWALK THE PERIMETER HEDGE ALONG | | | THE NORTH AND EAST SIDES OF THE PARKING LOT CAN BE | | | PLANTED ALONG THE PROPERTY LINE. | | | | | | 10. THE PERIMETER TREES SHALL BE REORIENTED IN ORDER TO | | | PROVIDE A TREE AT THE TERMINUS OF EACH PARKING ROW (ALL | | | FOUR CORNERS). ONE PROPOSED TREE IS SHOWN INSIDE OF THE | | | DUMPSTER ENCLOSURE. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-09-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-09 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-09 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-04-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-01 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-03-31 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2009-04-01 11:59:08 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT IR-1 MINIMUM TWO SETS OF SIGNED/SEALED PLANS | | | REQUIRED PER SECTION 106.1. PLEASE SUBMIT REQUIRED SETS | | | OF PLANS WITH APPLICATION. | | | | | | 2. SHT IR-1 SHALL BE SIGNED, SEALED AND DATED. THE | | | SHEET HAS NOT BEEN SEALED AND THE SIGNATURE IS A PHOTO | | | COPY OF AN ORIGINAL SIGNATURE. ORIGINAL "WET | | | SIGNATURES" ARE REQUIRED ON EACH SET OF PLANS. SECTION | | | 106.1, FAC 61G1-16.004(2) & FS 481.306. | | | | | | 3. SHT IR-1 THE METER, PVB, RAIN SENSOR & THE | | | CONTROLLER LOCATIONS ARE TO BE INDICATED ON THE PLANS. | | | SECTION 106.1.1 & APPENDIX "F" (J) & FS 373.62. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-08-04 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-08-04 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-08-02 |
Time |
21:20 |
Sent To |
ENG |
|
| Notes |
| 2009-08-04 11:46:05 | PASSED WITH PROVISO: COMMENTS FROM LANDSCAPE PLANNER | | | AND ENGINEERING SHALL BE RESOLVED PRIOR TO FINAL | | | APPROVAL. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-03-17 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-03-17 |
Time |
17:39 |
Sent To |
L |
|
| Notes |
| 2009-03-17 17:40:09 | PLANNING AND ZONING DEPT: ***ZONING FAILED - 1ST | | | RESUB*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | REPEAT COMMENT: | | | 2. PLEASE PROVIDE EXISTING NUMBER OF PARKING SPACES | | | VERSES PROPOSED. FOR YOUR REFERENCE, PROVIDED ATTACHED | | | IS A COPY OF THE GREEN CARD FOR THE SUBJECT PROPERTY. | | | CROSS REFERENCE THE NUMBER OF REQUIRED PARKING SPACES | | | FOR EACH TYPE OF UNIT LOCATED ONSITE. THE NUMBER OF | | | REQUIRED PARKING SPACES CAN BE FOUND IN THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-486. | | | SPECIFIC PARKING REQUIREMENTS; LOADING SPACE | | | REQUIREMENTS FOR INDIVIDUAL USES. TABLE XV-6, CITYWIDE | | | PARKING REQUIREMENTS, LINE ITEM 131. | | | | | | NEW COMMENTS: | | | 3. AS NOTED BY THE ENGINEERING PLAN REVIEWER, PLEASE | | | PROVIDE A RIGHT-OF-WAY PERMIT FOR THE PROPOSED APPROACH | | | EXTENSION FROM THE CITY'S ENGINEERING DEPARTMENT | | | (561.494.1040). | | | | | | 4. THE LOCATION OF THE PROPOSED DUMPSTER ENCLOSURE | | | CONFLICTS WITH THE PROPOSED PARKING SPACE AND DOES NOT | | | PROVIDE ENOUGH MANEUVERING FOR A VEHICLE TO SAFELY BACK | | | OUT FROM THE ADJACENT PARKING SPACE. RECONFIGURE THE | | | DESIGN IN ORDER TO ALLOW FOR ADEQUATE MANEUVERING | | | CAPABILITY. NOTE: REFER TO THE ZLDR, SECTION 94-485, | | | FIGURE XV-2, GENERAL PARKING DIMENSIONS, FOR MINIMUM | | | WIDTH REQUIREMENTS. | | | | | | 5. IN ACCORDANCE WITH THE ZLDR, SECTION 94-304, MINIMUM | | | SETBACKS FOR ACCESSORY STRUCTURES: THE DUMPSTER | | | ENCLOSURE SHALL BE SETBACK A MINIMUM OF FIVE (5) FEET | | | FROM THE REAR PROPERTY LINE. | | | | | | 6. THE PROPOSED LANDSCAPING DOES NOT MEET THE MINIMUM | | | REQUIRED PER CODE. PURSUANT TO THE CITY OF WEST PALM | | | BEACH ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), | | | SECTION 94-443??(3): OFF-STREET PARKING LOTS. | | | OFF-STREET PARKING LOTS CONTAINING AT LEAST 12 INTERIOR | | | PARKING SPACES SHALL CONTAIN LANDSCAPE AREAS. THE TOTAL | | | SIZE OF SUCH LANDSCAPED AREAS SHALL BE EQUAL TO TEN | | | SQUARE FEET FOR EACH PARKING SPACE AND SHALL BE | | | PROVIDED WITHIN THE INTERIOR OF AN OFF-STREET PARKING | | | AREA. LANDSCAPED AREAS SHALL CONTAIN AT LEAST ONE SHADE | | | OR FLOWERING TREE FOR EACH 100 SQUARE FEET OF REQUIRED | | | LANDSCAPED AREA. A MINIMUM OF 75 PERCENT OF ALL TREES | | | THAT ARE REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF | | | AN OFF-STREET PARKING AREA SHALL BE SHADE TREES. THE | | | SHADE TREES SHALL BE LOCATED IN SUCH A MANNER TO | | | PRODUCE MAXIMUM OVERHEAD CANOPY FOR THE VEHICLES. ALL | | | PARKING LOT LANDSCAPED AREAS SHALL BE PLANTED WITH | | | GRASS, GROUND COVER, SHRUBBERY, OR OTHER SUITABLE LIVE | | | PLANT MATERIAL. PARKING LOT LANDSCAPED AREAS SHALL BE | | | DESIGNED, PLANTED, AND MAINTAINED TO PERMIT CLEAR | | | VISION BETWEEN THE HEIGHT OF TWO FEET AND EIGHT FEET | | | ABOVE GRADE; HOWEVER, THIS REQUIREMENT SHALL NOT APPLY | | | WHERE THE LACK OF CLEAR VISION IS NOT DEEMED TO BE A | | | SAFETY HAZARD. TERMINAL ISLANDS, INTERIOR ISLANDS AND | | | DIVIDER MEDIANS SHOULD BE DESIGNED TO RETAIN MAXIMUM | | | WATER IN THE TURF AREAS AND ARE SUBJECT TO THE | | | FOLLOWING REQUIREMENTS. FIGURE XIV-1 IS AN EXAMPLE OF | | | THE LOCATION AND RELATIONSHIP BETWEEN THE PARKING LOT | | | LANDSCAPE AREAS AND THE PROPERTY. | | | | | | 7. ENSURE THE PARKING STALL DIMENSIONS MEET THE MINIMUM | | | STANDARDS AS INDICATED IN THE ZLDR, SECTION 94-485 (SEE | | | ATTACHED DETAIL). | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-02-12 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-02-12 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-02-12 |
Time |
13:21 |
Sent To |
I |
|
| Notes |
| 2009-02-12 13:43:42 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | | | 3. PURSUANT THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-444(B): | | | OUTDOOR INCINERATORS, GARBAGE OR TRASH RECEPTACLES, | | | FUEL OIL OR PROPANE TANKS, AND STORAGE RACKS SHALL NOT | | | BE PERMITTED UNLESS APPROPRIATE SCREENING IS PROVIDED. | | | | | | WALLS SHALL BE IRRIGATED AND LANDSCAPED WITH SHRUBS AND | | | HEDGES PLANTED AT TWO (2) FEET INTERVALS. SHOW A DETAIL | | | ON THE PLAN OF THE LANDSCAPING ALONG THE DUMPSTER | | | ENCLOSURE. | | | | | | IS THERE EXISTING IRRIGATION ON SITE THAT WILL PROVIDE | | | WATER TO PROPOSED LANDSCAPE SCREENING? IF SO, PLEASE | | | INDICATE LOCATION OF EXISTING IRRIGATION ON PLANS AND | | | DIRECTION OF WATER FLOW. IF NOT, IRRIGATION MUST BE | | | INSTALLED AND SHOW LOCATION OF PROPOSED IRRIGATION ON | | | PLANS. | | | | | | 4. PLEASE PROVIDE EXISTING NUMBER OF PARKING SPACES | | | VERSES PROPOSED. | | | | | | 5. PURSUANT TO XIV-2 - DIMENSIONAL REQUIREMENTS AND | | | SPECIFICATIONS FOR CURBS AND WHEEL STOPS, RODS FOR | | | ANCORANGE SHALL BE #5 X 18". SEE ATTACHED DETAIL FOR | | | SPECIFICATIONS. | | | | | | 6. THE HANDICAP PARKING DETAIL ON SHEET 3 OF 3 IS | | | MARKED OUT OF PLAN. PLEASE RESUBMIT A DETAIL OF THE | | | HANDICAP PARKING SPACE IN ACCORDANCE WITH THE ATTACHED | | | SPECIFICATIONS. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|