| Plan Review Stops For Permit 09010361 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-03-06 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-03-06 |
Time |
15:09 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-02-04 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-02-04 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2009-02-04 15:05:29 | 2004 FBC W/2007 REVISIONS | | | CHILLER REPLACEMENT | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. FS 713 | | | | | | 2) A BUILDING OR GENERAL CONTRACTOR WILL BE REQUIRED | | | FOR THE SCOPE OF WORK INVOLVING THE CUTTING AND | | | PATCHING OF THE CONCRETE ROOF SLAB, THE ASPHALT | | | PAVEMENT AND SIDEWALK. FS 489 | | | | | | 3) ADDITIONAL INFORMATION MAY BE REQUIRED DEPENDING ON | | | THE EXTENT AND TYPE OF THE ROOF REPAIRS. FBC EXISTING | | | BUILDING 401.3 AND 511.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-03-10 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-03-10 |
Time |
09:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-26 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-26 |
Time |
15:31 |
Sent To |
M |
|
| Notes |
| 2009-02-26 15:46:05 | | | | | | | | | | APPLICATION #09010361 ELECTRICAL PLAN REVIEW | | | 1525 PALM BEACH LAKES BLVD 1/30/09 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | THESE COMMENTS ARE FROM THE PREVIOUS REVIEW WITH NO | | | CHANGES OR RESPONSE: | | | | | | 1} SHEET E-5 ONE LINE POWER DIAGRAM-NEW WORK DOES NOT | | | INDICATE THE CONDUIT AND CONDUCTOR SIZE AND TYPE FOR | | | CIRCUITS 6, 7, AND 8 FOR THE NEW EQUIPMENT, LABEL | | | SAME.215.5 NEC. | | | | | | 2} AS THE MAIN BONDING JUMPER IS SHOWN IN MSBD (SAME | | | DIAGRAM AS ABOVE) INDICATE HOW THE EQUIPMENT MENTIONED | | | IN COMMENT #1 WILL BE BONDED PER 250.96(A), CONDUIT OR | | | EQUIPMENT GROUNDING CONDUCTOR. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-03 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-01-29 |
Time |
06:38 |
Sent To |
M |
|
| Notes |
| 2009-02-03 16:22:18 | | | | | | | | | | APPLICATION #09010361 ELECTRICAL PLAN REVIEW | | | 1525 PALM BEACH LAKES BLVD 1/30/09 | | | WEST PALM BEACH, FL. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} SHEET E-5 ONE LINE POWER DIAGRAM-NEW WORK DOES NOT | | | INDICATE THE CONDUIT AND CONDUCTOR SIZE AND TYPE FOR | | | CIRCUITS 6, 7, AND 8 FOR THE NEW EQUIPMENT, LABEL | | | SAME.215.5 NEC. | | | | | | 2} AS THE MAIN BONDING JUMPER IS SHOWN IN MSBD (SAME | | | DIAGRAM AS ABOVE) INDICATE HOW THE EQUIPMENT MENTIONED | | | IN COMMENT #1 WILL BE BONDED PER 250.96(A), CONDUIT OR | | | EQUIPMENT GROUNDING CONDUCTOR. | | | | | | 3} SHEET E-1 IN THE GENERAL ELECTRICAL NOTES #1, | | | REFERENCE THE CODES IN EFFECT UNDER THIS PERMIT, SEE | | | REVIEW CYCLES ABOVE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-08 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-08 |
Time |
13:26 |
Sent To |
M |
|
| Notes |
| 2009-04-08 13:26:48 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-20 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-20 |
Time |
10:42 |
Sent To |
E |
|
| Notes |
| 2009-02-20 10:42:39 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-02-04 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-01-27 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2009-01-27 10:38:55 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-08-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-05 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-05 |
Time |
15:24 |
Sent To |
PC |
|
| Notes |
| 2009-08-05 15:25:18 | PAGE M-10 REVISION DELTA 1 **PROVISO** | | | | | | NEED ENGINEERING DETAIL FOR ATTACHMENT OF EXPANSION | | | TANK TO SLAB FOR WIND RESISTANCE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-04-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-04-16 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-04-16 |
Time |
08:51 |
Sent To |
PC |
|
| Notes |
| 2009-04-16 09:16:26 | REVISED M-6, M-8, M-16, M-18 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-03-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-09 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-09 |
Time |
18:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-03-06 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-03 |
Time |
20:13 |
Sent To |
B |
|
| Notes |
| 2009-02-03 20:56:35 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | PROVIDE DETAIL FOR INSTALLATION AND ATTACHMENT OF ROOF | | | CURB AND VENTILATOR. SHOW THESE THINGS DESIGNED AND | | | INSTALLED FOR WIND RESISTANCE IN ACCORDANCE WITH FBCM | | | 301.13. | | | | | | MECHANICAL PLANS ARE OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|