Plan Review Details - Permit 09010286
Plan Review Stops For Permit 09010286
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-06-12 Cont ID  
Sent By rmcdouga Date 2009-06-12 Time 14:05 Rev Time 0.00
Received By rmcdouga Date 2009-06-12 Time 13:59 Sent To  
Notes
2009-06-12 14:01:33REVISION FOR FURRING CEILING IS OK.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-03-10 Cont ID  
Sent By rmcdouga Date 2009-03-10 Time 10:22 Rev Time 0.00
Received By rmcdouga Date 2009-03-10 Time 10:22 Sent To  
Notes
2009-03-10 10:20:24BUILDING PROVISO
  
 1) THIS UNIT IS LOCATED IN A BUILDING OF TYPE I
 CONSTRUCTION. THEREFORE, INTERIOR NON-BEARING WALL
 FRAMING ARE REQUIRED TO BE OF NONCOMBUSTIBLE MATERIALS.
 METAL OR FIRE-RETARDANT-TREATED WOOD STUDS ARE ALLOWED.
 FBC 602.2 AND 603.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-02-03 Cont ID  
Sent By rmcdouga Date 2009-02-03 Time 11:41 Rev Time 0.00
Received By rmcdouga Date 2009-02-03 Time 11:41 Sent To E
Notes
2009-02-03 13:12:05BUILDING PROVISO
  
 1) THIS UNIT IS LOCATED IN A BUILDING OF TYPE I
 CONSTRUCTION. THEREFORE, INTERIOR NON-BEARING WALL
 FRAMING ARE REQUIRED TO BE OF NONCOMBUSTIBLE MATERIALS.
 METAL OR FIRE-RETARDANT-TREATED WOOD STUDS ARE ALLOWED.
 FBC 602.2 AND 603.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-03-09 Cont ID  
Sent By btrobaug Date 2009-03-09 Time 16:58 Rev Time 0.00
Received By btrobaug Date 2009-03-09 Time 15:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-02-04 Cont ID  
Sent By btrobaug Date 2009-02-04 Time 16:53 Rev Time 0.00
Received By btrobaug Date 2009-02-04 Time 16:05 Sent To  
Notes
2009-02-04 16:52:40 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 ALL COMMENTS RELATE TO SHEET #3, UNLESS OTHERWISE
 NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS
 OTHERWISE NOTED.
  
 1} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE
 PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1).THE NEW BATHROOM DOES NOT
 COMPLY. LIST THIS CIRCUIT IN THE PANEL SCHEDULE.
  
 2} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH
 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. INDICATE GFI
 ON THE PLANS AND CORRECT THE SPACING.
  
 3} THE REFRIGERATOR CIRCUIT WAS NOT MOVED TO THE NEW
 REFRIGERATOR LOCATION ACCORDING TO THE RECEPTACLE
 NUMBER. 408.4.
  
 4} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE
 ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE
 INTERCONNECTION AND LOCATE THE ALARMS ON THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-03-17 Cont ID  
Sent By mwennerg Date 2009-03-17 Time 11:01 Rev Time 0.00
Received By mwennerg Date 2009-03-17 Time 11:01 Sent To  
Notes
2009-03-17 11:02:41AS PER FIRST REVIEW, LIFE SAFETY TO COMPLY WITH NFPA
 101, 2006. RED LINED PLANS TO REFLECT CORRECT EDITION.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-02-10 Cont ID  
Sent By mwennerg Date 2009-02-10 Time 13:12 Rev Time 0.00
Received By mwennerg Date 2009-02-10 Time 13:12 Sent To  
Notes
2009-02-10 13:19:10***DENIED***
  
 1) PLANS SUBMITTED AFTER DEC.31, 2008 SHALL COMPLY WITH
 NFPA 101, 2006 EDITION.
  
 2) PLEASE SHOW THE LOCATIONS OF THE EXISTING AND OR NEW
 HARD WIRED SMOKE ALARMS THAT SHALL BE INTERCONNECTED TO
 CAUSE THE ACTIVATION OF (1) SMOKE ALARM TO ACTIVATE ALL
 THE SMOKE ALARMS. 101, SEC. 9.6.2.9.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-06-11 Cont ID  
Sent By shill Date 2009-06-11 Time 18:09 Rev Time 0.00
Received By shill Date 2009-06-11 Time 18:09 Sent To  
Notes
2009-06-11 18:09:27BLDG REVISION TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmartine Date 2009-05-01 Time 15:53 Sent To  
Notes
2009-05-01 15:53:49SENT TO RON'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-02-25 Cont ID  
Sent By adarroug Date 2009-02-25 Time 16:56 Rev Time 0.00
Received By adarroug Date 2009-02-25 Time 16:56 Sent To  
Notes
2009-02-25 16:56:41TO "BOB"#11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-02-15 Cont ID  
Sent By rregueir Date 2009-02-15 Time 10:19 Rev Time 0.00
Received By rregueir Date 2009-01-30 Time 16:28 Sent To PC
Notes
2009-02-05 08:19:542/5/09--TO "BOB"#8
2009-01-30 16:31:54TO "SFR" "E"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By rregueir Date 2009-05-15 Time 15:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-03-25 Cont ID  
Sent By rregueir Date 2009-03-25 Time 09:31 Rev Time 0.00
Received By rregueir Date 2009-03-25 Time 09:25 Sent To PC
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-02-15 Cont ID  
Sent By rregueir Date 2009-02-15 Time 10:19 Rev Time 0.00
Received By rregueir Date 2009-02-15 Time 10:05 Sent To PC
Notes
2009-02-15 10:18:49REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. THE SCOPE OF A/C WORK AS SHOWN ON PLANS IS NOT
 CLEAR. ONLY AN "EXISTING HVAC" PLAN IS PROVIDED WITH NO
 CHANGES SHOWN ON PLANS. PLEASE SHOW ON PLANS WHICH
 PARTS OF THE A/C SYSTEM ARE BEING REMOVED AS WELL AS
 WHICH WORK IS TO BE NEW IN ACCORDANCE WITH FBCB
 106.1.1.
  
 2. PLEASE CLARIFY ALL DUCT SIZES SHOWN ON PLANS. ONE
 DUCT IS MARKED WITH A SIZE OF "MX6." IT IS NOT CLEAR
 WHAT THE SIZE OF THIS DUCT IS. ALSO, PLEASE INDICATE
 SIZES AT ALL DUCT TRANSITIONS TO CLARIFY THE DUCT SIZE
 ON BOTH SIDES OF THE TRANSITIONS IN ACCORDANCE WITH
 FBCM 603.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-03-12 Cont ID  
Sent By kstevens Date 2009-03-12 Time 14:03 Rev Time 0.00
Received By kstevens Date 2009-03-12 Time 14:03 Sent To  
Notes
2009-03-12 14:15:01PER ENGINEER, NO PLUMBING CHANGES TO SANITARY OR WATER
 LINES. NEW FIXTURES ONLY.

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-02-05 Cont ID  
Sent By kstevens Date 2009-02-05 Time 10:21 Rev Time 0.00
Received By kstevens Date 2009-02-05 Time 10:21 Sent To  
Notes
2009-02-05 10:32:16DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SHT 1 OF 3 EXISTING SANITARY RISER DIAGRAM FOR THE
 LAVS SHOW DOES NOT MEET CODE REQUIREMENTS NOR DOES IT
 REFLECT THE FLOOR PLAN. THE LAV IS NOT VENTED AND THE
 RISER SHOWS A 3RD WATER CLOSET, NOT TWO LAVS. (SEE RED
 LINE CORRECTION).
  
 2. SUBMIT A SANITARY RISER DIAGRAM FOR THE NEW LAV
 SHOWING THE CONNECTION TO THE EXISTING SANITARY, SHOW
 ALL PIPE SIZES, TRAPS AND VENTS. SECTIONS
 106.3.5.1.3(4)(6)(13), 701.1, 901.2.1 & 1002.1.
  
 3. MORE INFORMATION IS REQUIRED FOR THE KITCHEN. THE
 EXISTING FLOOR PLAN DOES NOT INDICATE THE LOCATION OF
 THE KITCHEN SINK. PLEASE INDICATE THE LOCATION AS
 EXISTING, AND IF THE KITCHEN SINK IS MOVED TO A NEW
 LOCATION, THEN A SANITARY RISER DIAGRAM FOR THE KITCHEN
 SINK SHALL BE SUBMITTED SHOWING THE POINT OF
 CONNECTION, THE PIPE SIZE, TRAP & VENT. SECTIONS
 106.3.5.1.3(4)(6)(13), 701.1, 901.2.1 & 1002.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2009-02-12 Cont ID  
Sent By kdfreema Date 2009-02-12 Time 09:58 Rev Time 0.00
Received By kdfreema Date 2009-02-12 Time 09:58 Sent To  
Notes
***NONE***