| Plan Review Stops For Permit 09010004 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-05-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-05-15 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-05-15 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-24 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-03-24 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2009-03-24 10:04:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1.TWO SETS OF PERMIT DOCUMENTS REQUIRED FOR PERMIT | | | ISSUANCE. ONLY ONE SET OF PRODUCT APPROVALS WAS | | | SUBMITTED. | | | | | | 2. PLEASE STAPLE OR CLIP THE PRODUCT APPROVALS PRIOR TO | | | RESUBMITTAL. THE PRODUCT APPROVALS WERE SUBMITTED AS | | | LOOSE SHEETS (APPROXIMATELY 5 PRODUCT APPROVALS, | | | APPROX. 50-70 SHEETS). IF THE SHEETS ARE SUBMITTED | | | LOOSE AND GET SEPARATED (DUE TO NOT BEING STAPLED OR | | | CLIPPED), CONTRACTOR WILL BE REQUIRED TO REASSEMBLE | | | PERMIT PACKAGE PRIOR TO ISSUANCE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-01-20 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-01-20 |
Time |
13:53 |
Sent To |
E |
|
| Notes |
| 2009-01-20 13:54:24 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. ALL INFORMATION REQUIRED BY FAC61G15-23.002 IS | | | REQUIRED ON EACH SHEET. | | | | | | 2. ALL DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS FS471. SOME SHEETS ARE NOT SIGNED, SEALED, | | | AND DATED. | | | | | | 3. ON THE PLAN, SPECIFY EACH REACTION FORCE AND | | | DIRECTION, FBC R CHAPTER 8. | | | | | | 4. SEE SHEET 2.2 AND THE SIMPSON CATALOG. SPEC SHEETS | | | FOR THESE CONNECTORS STATE DO NOT INSTALL BOLTS INTO | | | PILOT HOLES. THESE HOLES ARE PILOT HOLES USED DURING | | | THE MANUFACTURING PROCESS. PLEASE REVISE OR ADDRESS. | | | | | | 5. DETAIL 2 2.2 AND OTHER DETAILS INCLUDING SIMPSON | | | CONNECTORS, SPECIFY NAILING. | | | | | | 6. FBC2512.1, EXTERIOR PLASTER TO BE MINIMUM OF THREE | | | COATS, REVISE DETAIL 2 2.2 AND ANY OTHER DETAILS OR | | | NOTES WHICH SPECIFY PLASTER THICKNESS. | | | | | | 7. SHEET 6 REFERS TO TRUSS ENGINEERING, ISN???T THAT | | | INCLUDED IN THIS PLAN? | | | | | | 8. DETAIL 2 2.3 STATES THAT ROOF FRAMING PLAN WILL | | | PROVIDE DIMENSIONS AND NAILING FOR PLYWOOD. I WAS | | | UNABLE TO LOCATE, PLEASE SPECIFY PLYWOOD DIMENSION AND | | | NAILING PATTERN. | | | | | | 9. SHEET 8 STATES THIS IS AN OPEN STRUCTURE. SEE | | | FBC1609.2, DEFINITION OF OPEN BUILDING AND REVISE OR | | | CLARIFY. | | | | | | 10. IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | | PLANS MUST BE STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. 561-233-5025 FOR MORE INFORMATION. | | | | | | 11. PROVIDE WINDOW AND DOOR PRODUCT APPROVALS. IF THE | | | NON IMPACT GLAZING IS USED, PROVIDE PRODUCT APPROVAL | | | FOR IMPACT PROTECTION. FAC9B72 | | | | | | 12. IF SHUTTERS ARE USED, COMPLETE THE ATTACHED | | | INSTALLATION SCHEDULE. ALTERNATIVELY, THIS CAN BE | | | PROVIDED ON A SEPARATE PERMIT FOR SHUTTERS. HTTP://WWW. | | | CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATIO | | | N.PDF | | | | | | 13. PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF | | | RECORD, FBC*106.3.3. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-01-20 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-01-20 |
Time |
15:53 |
Sent To |
I |
|
| Notes |
| 2009-01-21 10:51:38 | | | | | | | | | | NO ELECTRICAL REVIEW DONE, NO ELECTRICAL WORK SHOWN. | | | THE BUILDING WAS WIRED WITHOUT A PERMIT. FEES DUE FROM | | | 4X PER BOB TILLEY. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | | | | | | 2009-01-20 16:20:47 | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-29 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-29 |
Time |
11:27 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-06 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-06 |
Time |
10:38 |
Sent To |
Z |
|
| Notes |
| 2009-03-06 10:38:35 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-06 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-06 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2009-01-06 14:06:19 | TO "MISC' BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-01-20 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-01-05 |
Time |
10:37 |
Sent To |
PC |
|
| Notes |
| 2009-01-21 10:53:39 | | | | | | | FEES DUE 4X FEE PER BOB TILLEY, PLANS UNDER "L" FOR | | | PICK UP./WRT. | | 2009-01-05 10:37:24 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-05-11 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-05-11 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-05-11 |
Time |
11:30 |
Sent To |
B |
|
| Notes |
| 2009-05-11 11:30:57 | ROUTED TO SH FOR BLDG REVIEW. ~MC |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-03-16 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-03-16 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-03-16 |
Time |
11:55 |
Sent To |
B |
|
| Notes |
| 2009-03-16 11:56:40 | PLANNING AND ZONING DEPT: ***ZONING FAILED - 1ST | | | RESUB*** | | | | | | REPEAT COMMENTS: | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING (NO WRITTEN | | | COMMENTS PROVIDED FOR ZONING IN RESPONSE LETTER FROM | | | MIGUEL M DEAVILA, DATED JANUARY 26, 2009). | | | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION | | | (PLAN INDICATES SURVEY WILL BE PROVIDED BY OWNER, BUT | | | NO SURVEY WAS INCLUDED IN RESUBMITTAL). | | | | | | 3. INDICATE IF ANY TREES WILL BE REMOVED AS A RESULT OF | | | THE PROPOSED PROJECT. IF YES, A TREE ALTERATION/REMOVAL | | | PERMIT WILL BE REQUIRED. CONTACT ROBERT KUSSNER, CITY | | | LANDSCAPE PLANNER, AT (561) 822-1462 FOR THE | | | APPLICATION. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-01-06 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-01-06 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-01-06 |
Time |
10:03 |
Sent To |
I |
|
| Notes |
| 2009-01-06 10:41:55 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | | | 3. INDICATE THE SEPARATION DISTANCE OF THE PROPOSED | | | ADDITION TO THE EXISTING SHED. NOTE: PURSUANT TO | | | SECTION 94-304(B)(3) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), ACCESSORY STRUCTURES SHALL BE | | | LOCATED NO CLOSER THAN SIX (6) FEET TO THE PRINCIPAL | | | STRUCTURE. | | | | | | 4. INDICATE IF ANY TREES WILL BE REMOVED AS A RESULT OF | | | THE PROPOSED PROJECT. IF YES, A TREE ALTERATION/REMOVAL | | | PERMIT WILL BE REQUIRED. CONTACT ROBERT KUSSNER, CITY | | | LANDSCAPE PLANNER, AT (561) 822-1462 FOR THE | | | APPLICATION. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|