Plan Review Details - Permit 08120457
Plan Review Stops For Permit 08120457
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-01-28 Cont ID  
Sent By mjacobs Date 2009-01-28 Time 14:14 Rev Time 0.00
Received By mjacobs Date 2009-01-28 Time 14:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-12-26 Cont ID  
Sent By mjacobs Date 2008-12-26 Time 16:46 Rev Time 0.00
Received By mjacobs Date 2008-12-26 Time 16:46 Sent To  
Notes
2008-12-26 16:46:24 
  
 BUILDING PLAN REVIEW
 PERMIT: 08120457
 ADD: 1641 WORTHINGTON ROAD
 CONT: DPR CONSTRUCTION INC.
 TEL: (561)273-6300
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 12-26-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE. INDICATE THE LEVEL OF ALTERATION ON THE
 PLANS.
  
 4) NOW THE SPACE IS BEING ALTERED, SHOW THE LOCATION OF
 THE SPRINKLER HEADS IN RELATION TO THE NEW WALL
 LOCATIONS. THIS INFORMATION CAN BE SHOWN ON THE
 REFLECTED CEILING PLANS. FBC 106.3.5.1.1 (5) FLORIDA
 STATUTES 553.79 (2)
  
 5) SHEET A3 DETAIL #4 MAKES REFERENCE TO SEE SHEET A4.0
 DETAIL #2, HOWEVER THE DETAIL #2 ON SHEET A4.0 DOES NOT
 CORRESPOND WITH THE REFERENCE NUMBER INDICATED.
 CLARIFY.
  
 6) SHEET A4 DETAIL #5 FAILS TO INDICATE THE 19 INCHES
 DEPTH WHICH SHALL BE PROVIDED UNDERNEATH THE SINK. FBC
 11-4.24.3. THE DRAWINGS NEED TO SHOW THE CLEAR FLOOR
 SPACE AT LEASE 30 INCHES BY 48 INCHES IN FRONT THE SINK
 TO ALLOW THE FORWARD APPROACH. THE CLEAR FLOOR SPACE
 SHALL EXTEND A MAXIMUM OF 19 INCHES UNDERNEATH THE SINK
 SEE FIGURE 32.
  
 7) SHEET A1.0 ROOM #103 INDICATES STORAGE: PLEASE STATE
 THE TYPE OF STORAGE PER FBC 311.
  
 8) 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE & EXTENT OF THE WORK
 PROPOSED & SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 AND RULES AND REGULATIONS AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-01-07 Cont ID  
Sent By btrobaug Date 2009-01-07 Time 11:09 Rev Time 0.00
Received By btrobaug Date 2009-01-07 Time 10:06 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-01-30 Cont ID  
Sent By mwennerg Date 2009-01-30 Time 10:36 Rev Time 0.00
Received By mwennerg Date 2009-01-30 Time 10:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-01-07 Cont ID  
Sent By mwennerg Date 2009-01-07 Time 12:22 Rev Time 0.00
Received By mwennerg Date 2009-01-07 Time 12:22 Sent To  
Notes
2009-01-07 12:27:42***PROVISO***
  
 PLANS WILL BE STAMPED WHEN RETURNED WITH THESE AND
 OTHER REVIEW COMMENT CORRECTIONS.
  
 1) PLEASE SHOW THE PROPOSED FIRE SPRINKLER HEAD LAYOUT
 WHICH MAY BE ILLUSTRATED ON THE REFLECTED CEILING PLAN.
 IN ADDITION, SEPARATE SHOP DRAWINGS AND PERMIT WILL BE
 REQUIRED PRIOR TO EQUIPMENT INSTALLATION.
  
 2) FIRE ALARM DRAWINGS SEEM TO SUGGEST CEILING MOUNTED
 A/V DEVICES. PLEASE EXPLAIN AND VERIFY THAT EQUIPMENT
 WILL BE INSTALLED IN ACCORDANCE WITH NFPA 72, 2002.
  
  
 MIKE WENNERGREN, ASST. FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-02-26 Cont ID  
Sent By adarroug Date 2009-02-26 Time 08:32 Rev Time 0.00
Received By adarroug Date 2009-02-26 Time 08:32 Sent To P
Notes
2009-02-26 08:33:06TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-01-26 Cont ID  
Sent By adarroug Date 2009-01-26 Time 10:57 Rev Time 0.00
Received By adarroug Date 2009-01-26 Time 10:57 Sent To  
Notes
2009-01-26 10:57:56TO "BOB"#14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-01-10 Cont ID  
Sent By rregueir Date 2009-01-10 Time 16:19 Rev Time 0.00
Received By rregueir Date 2008-12-23 Time 08:28 Sent To PC
Notes
2008-12-23 08:28:43TO "BOB"#7

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-01-10 Cont ID  
Sent By rregueir Date 2009-01-10 Time 16:19 Rev Time 0.00
Received By rregueir Date 2009-01-10 Time 16:03 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2009-03-18 Cont ID  
Sent By kstevens Date 2009-03-18 Time 14:43 Rev Time 0.00
Received By kstevens Date 2009-03-18 Time 14:43 Sent To  
Notes
2009-03-18 14:44:42REVISION OK -- SHT P0.1 - WATER HAMMER ARRESTOR TO BE
 LOCATED NEAR D.W. PDI-WH 201 - APPROVED C.I. TO COPPER
 ADAPTER REQUIRED 705.16.1.

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-02-04 Cont ID  
Sent By kstevens Date 2009-02-04 Time 16:47 Rev Time 0.00
Received By kstevens Date 2009-02-04 Time 16:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-01-08 Cont ID  
Sent By kstevens Date 2009-01-08 Time 14:06 Rev Time 0.00
Received By kstevens Date 2009-01-08 Time 14:06 Sent To  
Notes
2009-01-08 14:10:42DENIED
 REFERENCE:
 FBC-2004 PLUMBING
  
 1. SHT PO.1 DOMESTIC WATER ISOMETRIC SHOWS THE
 DISHWASHER SUPPLY AS COLD WATER. PER SECTION 607.1 HOT
 WATER SHALL BE SUPPLIED TO ALL PLUMBING FIXTURES &
 EQUIPMENT UTILIZED FOR WASHING, CULINARY PURPOSES, &
 CLEANSING.
  
 2. SHT P0.1 DOMESTIC WATER ISOMETRIC WILL BE REQUIRED
 TO SHOW A WATER HAMMER ARRESTOR FOR THE DISHWASHER.
 SECTION 604.9.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2008-12-31 Cont ID  
Sent By jroach Date 2008-12-31 Time 08:57 Rev Time 0.00
Received By jroach Date 2008-12-31 Time 08:57 Sent To  
Notes
***NONE***