Plan Review Details - Permit 08120415
Plan Review Stops For Permit 08120415
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-06-03 Cont ID  
Sent By rbrown Date 2009-06-03 Time 10:35 Rev Time 0.00
Received By rbrown Date 2009-06-03 Time 10:35 Sent To  
Notes
2009-06-03 10:57:13BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN (561) 805 6652
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2004
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 STRUCTURAL REVISION SUBMITTED ON 6/3/09 FOR CHANGE OF
 SIGN POLES FROM BOLTED BASE PLATE TO EMBEDDED POLE.
  
 1) FBC* 117 AND FBC 1601 THE DESIGN WIND SPEED FOR CITY
 OF WEST PALM BEACH IS 140 MPH. THE REVISED CALCULATION
 SHEET SIGNED AND SEALED BY ROBERT W. WALL STATES THAT
 THIS DESIGN IS BASED ON A WIND SPEED OF ONLY 130 MPH.
 REVISE THE CALCULATION TO JUSTIFY THE PROPOSED DEPTH OF
 POST EMBEDMENT AND SIZE OF FOUNDATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6652 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-04-02 Cont ID  
Sent By shill Date 2009-04-02 Time 15:40 Rev Time 0.00
Received By shill Date 2009-04-02 Time 15:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-01-07 Cont ID  
Sent By shill Date 2009-01-07 Time 16:54 Rev Time 0.00
Received By shill Date 2009-01-07 Time 16:54 Sent To  
Notes
2009-01-07 17:19:26****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. SEE FS481.223(1)(C): A PERSON MAY NOT KNOWINGLY: USE
 THE NAME OR TITLE "ARCHITECT" OR "REGISTERED
 ARCHITECT," . . . OR WORDS TO THAT EFFECT, WHEN THE
 PERSON IS NOT THEN THE HOLDER OF A VALID LICENSE ISSUED
 PURUSANT TO THIS PART. AT ISSUE IS THE USE OF THE NAME
 "ARCHITECTURAL SERVICES AND ENGINEERING, INC." I WAS
 UNABLE TO LOCATE A CERTIFICATE OF AUTHORIZATION
 (ARCHITECTURE) FOR THE COMPANY ISSUED BY THE FLORIDA
 BOARD OF ARCHITECTS IN THIS NAME. A SET HAS BEEN
 RETAINED. WHEN RESUBMITTING, PLEASE PROVIDE TWO
 ORIGINAL SETS OF PERMIT DOCUMENTS. IF THIS COMPANY HAS
 A CERTIFICATE OF AUTHORIZATION TO PRACTICE
 ARCHITECTURE, PLEASE PROVIDE THAT LICENSE NUMBER ON THE
 PLAN IN ORDER TO SHOW COMPLIANCE WITH STATUTORY
 REQUIREMENTS.
  
 2. THE PARCEL ON THE PERMIT APPLICATION IS NOT THE
 PARCEL SHOWN ON THE SITE PLAN. IF THE SIGN IS BEING
 MOVED FROM ONE SITE TO ANOTHER SITE, PLEASE APPLY FOR A
 DEMOLITION PERMIT TO REMOVE THE SIGN FROM 2101
 OKEECHOBEE BLVD, AND THE APPLICATION TO INSTALL THE
 SIGN SHOULD REFER TO THE SAME PARCEL AS SHONW ON THE
 SITE PLAN (LOCATION OF PROPOSED SIGN INSTALLATION).

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-01-06 Cont ID  
Sent By btrobaug Date 2009-01-06 Time 12:43 Rev Time 0.00
Received By btrobaug Date 2009-01-06 Time 12:40 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-03-17 Cont ID  
Sent By adarroug Date 2009-03-17 Time 11:49 Rev Time 0.00
Received By adarroug Date 2009-03-17 Time 11:49 Sent To Z
Notes
2009-03-17 11:50:02TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-30 Cont ID  
Sent By adarroug Date 2008-12-30 Time 15:22 Rev Time 0.00
Received By adarroug Date 2008-12-30 Time 15:22 Sent To E
Notes
2008-12-30 15:22:47TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-01-07 Cont ID  
Sent By shill Date 2009-01-07 Time 17:21 Rev Time 0.00
Received By shill Date 2008-12-19 Time 09:20 Sent To  
Notes
2008-12-19 09:20:24TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2009-04-01 Cont ID  
Sent By eschneid Date 2009-04-01 Time 09:36 Rev Time 0.50
Received By eschneid Date 2009-04-01 Time 09:36 Sent To B
Notes
2009-04-01 09:41:18NEW HIGH FREESTANDING SIGN = 190 SQUARE FEET.
 EXISTING HIGH FREESTANDING SIGN = 300 SQUARE FEET.
  
 TOTAL HIGH FREE STANDING ALONG OKEECHOBEE = 490 SQUARE
 FEET.
  
 TOTAL ALLOWED HIGH FREE STANDING ALONG OKEECHOBEE = 644
 SQUARE FEET.

Review Stop Z ZONING
Rev No 1 Status F Date 2008-12-29 Cont ID  
Sent By eschneid Date 2008-12-29 Time 11:16 Rev Time 0.50
Received By eschneid Date 2008-12-29 Time 11:16 Sent To  
Notes
2008-12-29 11:38:14FAILED
  
 1) THE SCOPE OF WORK "MOVE EXISTING PYLON SIGN TO NEW
 LOCATION" MAY ONLY BE DONE ON ONE PERMIT IF IT IS A
 MOVE WITHIN ONE PROPERY. THIS APPLICATION IS TO MOVE
 THE SIGN TO A DIFFERENT PROPERTY, THEREFORE, A
 DEMOLITION PERMIT IS REQUIRED TO REMOVE THE SIGN FROM
 2101 OKEECHOBEE BLVD. AND AN SEPARATE PERMIT IS
 REQUIRED TO INSTALL THE SIGN AT 2901 OKEECHOBEE BLVD.
  
 2) THE SITE PLAN PROVIDED IS NOT THE MOST RECENT
 APPROVED SITE PLAN. THE RETENTION AREA, DISPLAY PARKING
 AND DRIVE ENTRANCES HAVE BEEN CHANGED.
  
 3) THE NEW SIGN LOCATION ON 2901 OKEECHOBEE BLVD. IS
 NOT IN THE SAME LOCATION AS THE MOST RECENT APPROVED
 SITE PLAN.
  
 4) IF THE SIGN WILL BE LOCATED AS SHOWN, THEN THE SITE
 AND LANDSCAPE PLANS SHALL BE AMENDED THROUGH THE MINOR
 DEVELOPMENT OF SIGNIFICANT IMPACT AMENDMENT PROCESS
 PRIOR TO THE ISSUANCE OF THE BUILDING PERMIT FOR NEW
 INSTALLATION. CONTACT ERIC SCHNEIDER @ (561) 822-1435
 IN THE PLANNING AND ZONING DEPT. FOR INFORMATION ON THE
 APPLICATION.
  
 5) THERE ARE EXISTING MONUMENT/PYLON SIGNS ON THE SITE.
 THE PERMIT SHALL CLEARLY SHOW THE EXISTING SIGNS WITH
 THE HEIGHT AND THE SQUARE FOOTAGE OF EACH SIGN. NOTE
 THAT IF EXISTING SIGNS ARE PROPOSED TO BE REMOVED AND
 REPLACED BY THE SIGNS FROM 2101 OKEECHOBEE BLVD., THEN
 THIS SHALL BE STATED AND A DEMOLITION PERMIT FOR THE
 REMOVED SIGNS IS REQUIRED.


Account Summary | Usage Policy | Privacy Policy