| Plan Review Stops For Permit 08120314 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-03-03 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-03-03 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-03-03 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-03-03 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2009-03-03 10:42:52 | OWNER BUILDER SUBMITTED ENERGY CALCS. STATUS WILL BE | | | CHANGED TO P WHEN IMPACT FEES ARE PAID AND STAMPED | | | PLANS RETURNED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-03-02 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-03-02 |
Time |
11:51 |
Sent To |
M |
|
| Notes |
| 2009-03-02 11:56:55 | 2004 FBC W/2007 REVISIONS | | | ADDITION | | | | | | DENIED BY BUILDING | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. FS 713 | | | | | | 3) SUBMIT TWO (2) COPIES OF ENERGY CALCULATION FORMS AS | | | REQUIRED BY FBC 13-600. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-01-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-01-12 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-01-12 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2009-01-12 13:22:22 | 2004 FBC W/2007 REVISIONS | | | ADDITION | | | | | | DENIED BY BUILDING | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. FS 713 | | | | | | 3) SUBMIT TWO (2) COPIES OF ENERGY CALCULATION FORMS AS | | | REQUIRED BY FBC 13-600. | | | | | | 4) THE MINIMUM R-VALUE FOR A 2 X 6 FRAME WALL IS R-19 | | | PER FBC 13-602.1.C.1.1. PLEASE REVISE WALL SECTION ON | | | A-2. | | | | | | 5) THE R-30 BATT CEILING INSULATION SPECIFIED ON A-2 IS | | | 9-1/2" THICK AND WILL NOT ALLOW FOR FREE AIR FLOW | | | BETWEEN THE 2 X 8 RAFTERS/JOISTS. THE MINIMUM ALLOWED | | | FOR A SINGLE ASSEMBLY ROOF IS R-19 WHICH IS 5-1/2" | | | THICK. SEE FBC 13-604.1.ABC.1. PLEASE REVISE. | | | | | | 6) SHOW COMPLIANCE WITH R703.6.3. WHERE CEMENT PLASTER | | | (STUCCO) IS TO BE APPLIED TO LATH OVER FRAME | | | CONSTRUCTION, MEASURES SHALL BE TAKEN TO PREVENT | | | BONDING BETWEEN THE CEMENT PLASTER AND THE | | | WATER-RESISTIVE BARRIER. A BOND BREAK SHALL BE PROVIDED | | | BETWEEN THE WATER-RESISTIVE BARRIER AND THE CEMENT | | | PLASTER (STUCCO) CONSISTING OF ONE OF THE FOLLOWING: | | | 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER | | | MATERIAL; OR | | | 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER | | | OVER AN APPROVED PLASTIC HOUSE WRAP; OR | | | 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN | | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS. | | | | | | 7) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 8) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE ROOF | | | COVERING IS FOR UNDERLAYMENT AND IS NOT FOR A FLAT ROOF | | | SYSTEM. SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | FLAT ROOF SYSTEM THAT WILL BE INSTALLED. SPECIFY WHICH | | | ONE OF THE APPROVED ASSEMBLIES LISTED IN THE NOA WILL | | | BE USED. SPECIFY THE FASTENING OPTION AND DESIGN | | | PRESSURE THAT WILL BE USED. PROVIDE RAS 117 FOR | | | ENHANCED FASTENING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY LIMITATION #7 OF THE NOA. DCA RULE 9B-72 | | | | | | 9) THE VALUE FOR THE ADDITION SPECIFIED ON THE | | | APPLICATION IS LOW. BASED ON THE ICC BUILDING VALUATION | | | DATA THE COST FOR 312 SQFT TYPE VI CONSTRUCTION IS | | | $30,210.00. THE VALUE HAS BEEN ADJUSTED AND ADDITIONAL | | | FEES OF $599.67 ARE DUE. FBC 108.3* CITY AMENDMENTS | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-23 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-23 |
Time |
11:10 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-19 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-12-19 |
Time |
14:29 |
Sent To |
M |
|
| Notes |
| 2008-12-19 14:44:22 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL | | | COST OF LABOR AND MATERIAL. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES PER 108.3 FBC AS | | | AMENDED. | | | | | | A PERMIT SHALL NOT BE ISSUED UNTIL FEES AUTHORIZED | | | UNDER SECTION 553.80, FLORIDA STATUTES, HAVE BEEN PAID. | | | 108.1 FBC. | | | | | | ADJUST THE VALUE AT THE PERMIT CLERK?S DESK, AND PAY | | | THE DIFFERENCE IN FEES PRIOR TO RESUBMITTING. | | | | | | 2} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471 | | | FS, RESPECTIVELY. | | | THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL | | | IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES, | | | IF EXEMPTIONS APPLY. | | | | | | 3} A LAUNDRY RECEPTACLE OUTLET(S) IS SUPPLIED BY A | | | 20-AMPERE BRANCH CIRCUIT. THIS CIRCUIT CAN HAVE NO | | | OTHER OUTLETS. SEE 210.11(C)(2) FOR FURTHER | | | INFORMATION.*** THE PANEL SCHEDULE INDICATES THE | | | EXTERIOR | | | | | | 4} THE DRYER RATED AT 5000 WATTS ON THE PANEL SCHEDULE | | | IS SHOWN WITH A 20 MP OVER CURRENT PROTECTION, AND | | | SHOWN AS EXISTING. THE DRYER CALCULATION SHOULD BE | | | 5000/240=20.83 A25 AMP BREAKER (240.6) AND #10 | | | CONDUCTORS (310.16). ALSO THE FRAME IS REQUIRED TO BE | | | GROUNDED WITH AN EQUIPMENT GROUNDING CONDUCTOR PER | | | 250.140 AND 251.122. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-10 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-10 |
Time |
09:59 |
Sent To |
Z |
|
| Notes |
| 2009-02-10 09:59:53 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-01-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-01-12 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-12-16 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2008-12-16 09:29:19 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-03-03 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-03-03 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2009-03-03 10:53:47 | MECHANICAL PROVISO | | | | | | BALANCED RETURN AIR IS REQUIRED PER FBC MECHANICAL | | | 601.4. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2008-12-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-22 |
Time |
18:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-22 |
Time |
18:35 |
Sent To |
B |
|
| Notes |
| 2008-12-22 18:37:03 | NO INFORMATION PROVIDED ON PLANS FOR VENTILATION, AIR | | | CONDITIONING OR DRYER EXHAUST. SEPARATE PLANS AND | | | PERMIT APPLICATION REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-02-26 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-02-26 |
Time |
16:47 |
Sent To |
B1 |
|
| Notes |
| 2009-02-26 16:48:57 | PASSED/PROVISO -- 3" REQUIRED TO W/M (406.3) & C/O AT | | | W/M TO BE 4' ABOVE THE FLOOR (708.9). |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-12-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-18 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-18 |
Time |
16:16 |
Sent To |
E |
|
| Notes |
| 2008-12-18 16:20:31 | DENIED | | | REFERENCE: | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT A-3 THE PERSON TAKING RESPONSIBILITY FOR THE | | | DESIGN OF THE PLANS SHALL PRINT THEIR NAME AND AFFIX | | | THEIR SIGNATURE ON SAID PLANS. FS 481.029 OR 471.003 OR | | | THE EXEMPTIONS TO THOSE STATUTES. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-02-23 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-02-23 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-02-23 |
Time |
08:19 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-12-17 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-12-17 |
Time |
11:57 |
Sent To |
E |
|
| Notes |
| 2008-12-17 12:08:03 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. INDICATE THE SETBACK DIMENSIONS FROM THE PROPSED | | | ADDITION TO ALL ADJACENT PROPERTY LINES. NOTE: PURSUANT | | | TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZDLR), SECTION 94-75(A)(2): | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLWS: | | | | | | A. FRONT: 25 FEET; | | | | | | B. CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60 | | | FEET WIDE; | | | | | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH WHICHEVER | | | IS LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | 3. INDICATE THE SEPARATION DISTANCE OF THE PROPOSED | | | ADDITION TO THE EXISTING WOOD FRAME GARAGE. NOTE: | | | PURSUANT TO SECTION 94-304(B)(3) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), ACCESSORY STRUCTURES | | | SHALL BE LOCATED NO CLOSER THAN SIX (6) FEET TO THE | | | PRINCIPAL STRUCTURE. | | | | | | 4. INDICATE IF ANY TREES WILL BE REMOVED AS A RESULT OF | | | THE PROPOSED PROJECT. IF YES, A TREE ALTERATION/REMOVAL | | | PERMIT WILL BE REQUIRED. CONTACT ROBERT KUSSNER, CITY | | | LANDSCAPE PLANNER, AT (561) 822-1462 FOR THE | | | APPLICATION. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|