| Plan Review Stops For Permit 08120284 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2009-10-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-10-15 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-10-15 |
Time |
10:08 |
Sent To |
PC |
|
| Notes |
| 2009-10-15 10:16:09 | BUILDING REVISION CHECKLIST. | | | | | | 1- ENGINEER'S STRUCTURAL BUCK DETAIL IS INCORRECT. 1X2 | | | BUCK SIZE IS NOT ADEQUATE TO PROVIDE FULL DOOR/WINDOW | | | FRAME SUPPORT AS REQUIRED BY SEC. R613.6 OF 2004 | | | FLORIDA RESIDENTIAL CODE. REVISE SIZE AS REQUIRED. | | | ALSO, ENGINEER TO LOOK AT THE PRODUCT APPROVALS FOR | | | REQUIRED BUCK SIZE. | | | | | | ***NOTE: EXTERIOR DOOR AND IMPACT SINGLE HUNG WINDOWS | | | AS WELL AS THE REVISED ENERGY CALCUATIONS WERE APPROVED | | | ON THIS SUBMITTAL. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-07-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-07-15 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-07-15 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2009-07-15 14:33:19 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- PROVIDE CURRENT PRODUCT APPROVAL FOR EXTERIOR DOORS. | | | | | | 2- PROVIDE COMPLETE SHUTTERS INSTALLATION SCHEDULE (SEE | | | ATTACHED SAMPLE) AND CLEARLY MARK SHUTTERS DRAWINGS | | | WITH PROPOSED SHUTTERS INSTALLATION (EG: WALL MOUNTED, | | | BUILT OUT, ETC) AND SPECIFIC TYPE OF ANCHOR AND SPACING | | | TO BE USED. | | | | | | 3- SPECIFY STRUCTURAL DOOR BUCK SIZE AND FASTENERS. SEE | | | PRODUCT APPROVAL FOR REQUIRED BUCK SIZE. | | | | | | 4- REVISE ENERGY CALCULATIONS. REVISE OVERHANG HEIGHT | | | SHOWN ON 2ND PAGE OF CALCULATIONS SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-06-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-06-22 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-06-10 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2009-06-10 11:27:10 | NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW THIRD | | | CHECKLIST. | | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | | REVISIONS. | | | | | | ***NOTE: ONLY ONE SET OF ENGINEER'S PLANS WERE | | | SUBMITTED THIS TIME. | | | | | | 1- PLANS TO SPECIFY ALL LIVE AND DEAD LOADS AS REQUIRED | | | BY SEC. R301.1 AND TABLE R301.5 OF 2004 FLORIDA | | | RESIDENTIAL CODE. NOTE: ATTIC LIVE LOADS NEED TO BE | | | INCLUDED ALSO. (REPEAT COMMENT- THREE TIMES). | | | STRUCTURAL LOADS SPECIFICATIONS SUBMITTED ON SHEET A3 | | | ARE VERY CONFUSING AND STILL ARE NOT ADDRESSING THE | | | REQUIRED ATTIC LIVE LOADS REQUIRED BY TABLE R301.5 OF | | | 2004 FLORIDA RESIDENTIAL CODE. (THIS IS THE THIRD TIME | | | THAT THIS ISSUE IS NOT ADDRESSED. ENGINEER TO PAY FOUR | | | TIMES THE FEE FOR PLAN REVIEW AS REQUIRED BY FLORIDA | | | STATUTE SEC. 553.80(2)(B). SEE ATTACHED COPY. ENGINEER | | | OWES $3,705.63 FOR MULTIPLE PLAN REVIEW REJECTIONS). | | | | | | 2- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) ENTRY DOOR AND KITCHEN AND BEDROOM EXTERIOR DOORS. | | | ACCORDING TO MIAMI-DADE COUNTY WEBSITE NOA 07-0731.04 | | | SUBMITTED IS NO GOOD. FILE FOR THIS NOA WAS CLOSED BY | | | MIAMI-DADE COUNTY. SEE ATTACHED COPY FROM MIAMI-DADE | | | COUNTY. PROVIDE CURRENT NOA AND ENGINEER TO REVIEW | | | PRODUCT APPROVAL PRIOR TO SUBMITTAL. | | | | | | B) HURRICANE SHUTTERS: PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE ATTACHED SAMPLE. COMPLETE ALL THE | | | INFORMATION AND CLEARLY MARK ON SHUTTERS DRAWINGS | | | SPECIFIC MOUNTING CONDITIONS (EG: WALL MOUNTED, BUILD | | | OUT, ETC) AND SPECIFIC ANCHOR TYPE AND SPACING TO BE | | | USED. (REPEAT COMMENT- THREE TIMES). | | | THIS ITEM WAS NOT ADDRESSED AT ALL. PROVIDE COMPLETE | | | INFORMATION. | | | | | | 3- SINCE THE ENERGY CALCULATIONS ARE TAKEN THE CEILING | | | FAN CREDIT, THEN THE ELECTRICAL PLAN NEEDS TO SHOW SIZE | | | OF CEILING FANS AS REQUIRED BY TABLE 13-607.1.A.1 OF | | | FBC 2004. AND, THEY NEED TO BE INSTALLED FOR | | | INSPECTION. NEED TO REVISE SIZE OF CEILING FAN ON | | | LIVING ROOM. | | | REPEAT COMMENT. SIZE WAS NOT CHANGED | | | | | | 4- PROVIDE DRAINAGE PLAN TO SHOW COMPLIANCE WITH SEC. | | | R401.3 OF 2004 FLORIDA RESIDENTIAL CODE. | | | REVISE DRAINAGE PLAN SHOWN ON SITE PLAN ON SHEET A1. | | | ARROWS SHOW WATER TO BE DIVERTED TO THE ADJACENT | | | NEIGHBORS. WATER CAN'T RUN INTO ADJACENT PROPERTIES. | | | (REPEAT COMMENT). | | | | | | 5- SHEET A1: | | | A) SPECIFY ATTIC SIZE TO SHOW COMPLIANCE WITH SEC. R807 | | | OF 2004 FLORIDA RESIDENTIAL CODE. | | | 22" X 22" SIZE SHOWN DOESN'T COMPLY. REVISE AS | | | REQUIRED. (REPEAT COMMENT). | | | | | | B) COORDINATE DESIGN PRESSURES FOR WINDOWS. INFORMATION | | | SHOWN ON THE OPENINGS ON BUILDING INFORMATION CHART | | | DOESN'T MATCH INFORMATION SHOWN ON EXTERIOR ELEVATIONS. | | | REVISE AS REQUIRED TO MATCH. (REPEAT COMMENT). | | | | | | C) ENTRY DOOR TO BE MIN. 3'-0" WIDE BY 6'-8" HEIGHT AS | | | REQUIRED BY SEC. R311.4.2 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | FOUNDATION PLAN SHOWS ENTRY DOOR OPENING TO BE 3'-2" . | | | THIS MASONRY OPENING WON'T ALLOW TO INSTALL 3'-0" WIDE | | | DOOR. REVISE AS REQUIRED. NOTE: KEEP IN MIND REQUIRED | | | BUCK SIZE. SEE PRODUCT APPROVAL. (REPEAT COMMENT). | | | | | | D) MASTER BATHROOM TYPE OF DOOR SHOWN ON FLOOR PLAN | | | DOESN'T MATCH TYPE OF DOOR SHOWN ON DOOR SCHEDULE. | | | REVISE AS REQUIRED. | | | NOT ADDRESSED. (REPEAT COMMENT). | | | | | | E) SIZE OF WINDOW SPECIFIED ON WINDOW SCHEDULE DOESN'T | | | MATCH SIZE OF WINDOW SHOWN ON BUILDING INFORMATION | | | CHART. REVISE AS REQUIRED. | | | NOT ADDRESSED. WINDOW SCHEDULE SHOWS H32, WHILE | | | BUILDING INFORMATION CHART SHOWS H33. REVISE AS | | | REQUIRED TO MATCH. (REPEAT COMMENT). | | | | | | F) NOTE INSIDE FOUNDATION PLAN CALLS FOR 48" MAX. | | | SPACING FOR VERTICAL REINFORCEMENT BETWEEN FILLED | | | CELLS. FOUNDATION PLAN AND FLOOR PLANS SHOW SOME AREAS | | | WHERE THE THE MAX. VERTICAL SPACING OF FILLED CELLS | | | EXCEED THE 48". REVISE AS REQUIRED. | | | PLANS NOW DON'T SPECIFY THE SPACING OF VERTICAL | | | REINFORCEMENT. PROVIDE SPECIFICATIONS OR PROVIDE | | | DIMENSIONS ON FOUNDATION PLAN. (REPEAT COMMENT). | | | | | | G) REVISE BUILDING WIDTH AND BUILDING LENGTH DIMENSIONS | | | SHOWN ON BUILDING INFORMATION CHART. SEE FLOOR PLANS | | | FOR ACTUAL DIMENSIONS. | | | REVISE BUILDING LENGTH. (REPEAT COMMENT). | | | | | | H) REVISE BUILDING SIDE SETBACK DIMENSIONS SHOWN ON | | | SITE PLAN. 122'? (REPEAT COMMENT). | | | | | | 6- SHEET A2: | | | A) WHERE IS BEAM B-2 SPECIFIED ON EXTERIOR CMU WALL | | | SECTION A/A2?. (REPEAT COMMENT). | | | | | | 7- SHEET A3: | | | A) REVISE NUMBER/SIZE OF NAILS AND UPLIFT LOADS SHOWN | | | ON TRUSS CONNECTORS SPECIFIED ON ROOF FRAMING PLAN. SEE | | | CONNECTOR PRODUCT APPROVAL AND REVISE AS REQUIRED. | | | NOT ADDRESSED. (REPEAT COMMENT). | | | | | | B) REVISE SIZE OF STRUCTURAL BUCK SHOWN ON BUCK DETAIL | | | FOR DOOR. SEE PRODUCT APPROVAL FOR REQUIRED SIZE. ALSO, | | | DOOR FRAME NEEDS TO BE FULLY SUPPORTED ON BUCK AS | | | REQUIRED BY SEC. R613.6 OF 2004 FLORIDA RESIDENTIAL | | | CODE. PROVIDE BUCK SIZE THAT PROVIDES FULL SUPPORT TO | | | DOOR FRAME. (REPEAT COMMENT). | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-03-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-03-13 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-03-13 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2009-03-13 15:15:38 | NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW | | | SECOND CHECKLIST. | | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | | REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | | | ***RESPONSE: NOTICE OF COMMENCEMENT SUBMITTED WAS | | | RECORDED ON 12/12/2008. IT EXPIRES AFTER 90 DAYS WHEN | | | WORK IS NOT STARTED. SEC. 713.13 FLORIDA STATUTE. NEED | | | TO PROVIDE RE-RECORDED ONE. | | | | | | 2- PLANS TO SPECIFY ALL LIVE AND DEAD LOADS AS REQUIRED | | | BY SEC. R301.1 AND TABLE R301.5 OF 2004 FLORIDA | | | RESIDENTIAL CODE. NOTE: ATTIC LIVE LOADS NEED TO BE | | | INCLUDED ALSO. | | | | | | ***RESPONSE: | | | STRUCTURAL LOADS SPECIFICATIONS SUBMITTED ON SHEET A3 | | | ARE VERY CONFUSING AND STILL ARE NOT ADDRESSING THE | | | REQUIRED ATTIC LIVE LOADS REQUIRED BY TABLE R301.5 OF | | | 2004 FLORIDA RESIDENTIAL CODE. | | | NOTE: ONE SET OF PLANS WAS RETAINED IN THIS OFFICE TO | | | SEND TO BOARD OF ENGINEERS FOR REVIEW. | | | | | | 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) PRECAST LINTELS AS SHOWN ON PLANS. | | | | | | ***RESPONSE: | | | NOA #03-0605.04 SUBMITTED EXPIRED ON 09/11/2008 AND IS | | | FOR 4", 6" AND 12" PRECAST LINTELS. NONE OF THESE SIZES | | | ARE USED ON PLANS. PROVIDE PRODUCT APPROVAL FOR 8" | | | LINTELS. ALSO, ENGINEER OF RECORD TO REVIEW AND APPROVE | | | IN WRITING NEW PRODUCT APPROVAL. | | | | | | B) ENTRY DOOR AND KITCHEN AND BEDROOM EXTERIOR DOORS. | | | CLEARLY IDENTIFY WHICH PRODUCT APPROVAL IS FOR THE | | | ENTRY AND ALL OTHER OPENINGS. | | | ***NOTE: NOA 02-1211.10 SUBMITTED EXPIRED ON JULY 17, | | | 2008. NEED TO PROVIDE CURRENT PRODUCT APPROVAL. | | | | | | ***RESPONSE: | | | (1) NOA 04-1022.04 SUBMITTED IS FOR "INSWING" DOORS. | | | PLANS SHOW "OUTSWING" DOORS. REVISE AS REQUIRED. | | | | | | (2) MISSING BEDROOM EXTERIOR DOOR. | | | | | | (3) PRODUCT APPROVAL SUBMITTED DOESN'T MATCH TYPE OF | | | DOOR SHOWN ON DOOR SCHEDULE AND EXTERIOR ELEVATIONS. | | | REVISE AS REQUIRED. | | | | | | (4) GLASS DON'T HAVE IMPACT PROTECTION. SHUTTERS ARE | | | REQUIRED. COORDINATE WITH STORM SHUTTERS INSTALLATION | | | SCHEDULE. | | | | | | (5) PRODUCT APPROVAL SUBMITTED IS FOR 8'-0" HIGH DOORS. | | | SEE PLANS FOR SIZE SPECIFIED. | | | | | | (6) PRODUCT APPROVAL SUBMITTED DOESN'T MEET THE DESIGN | | | PRESSURES CALCULATED BY THE ENGINEER. REVISE AS | | | REQUIRED. | | | | | | C) HURRICANE SHUTTERS: PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE ATTACHED SAMPLE. COMPLETE ALL THE | | | INFORMATION AND CLEARLY MARK ON SHUTTERS DRAWINGS | | | SPECIFIC MOUNTING CONDITIONS (EG: WALL MOUNTED, BUILD | | | OUT, ETC) AND SPECIFIC ANCHOR TYPE AND SPACING TO BE | | | USED. | | | | | | ***RESPONSE: | | | THIS ITEM WAS NOT ADDRESSED AT ALL. PROVIDE COMPLETE | | | INFORMATION AND CLARIFY WHY SUBMITTING TWO DIFFERENT | | | PRODUCT APPROVALS FOR TWO DIFFERENT MANUFACTURER'S. | | | ALSO, PLEASE MAKE SURE TO PROVIDE TWO COPIES FOR EITHER | | | SELECTION. EG: ONLY ONE COPY OF NOA 06-0706.17 WAS | | | PROVIDED. AND, PRODUCT APPROVAL NEEDS TO BE REVIEWED | | | AND APPROVED BY THE ENGINEER OF RECORD. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | ***RESPONSE: SOME PRODUCT APPROVALS SUBMITTED WERE NOT | | | APPROVED BY THE ENGINEER. | | | | | | 5- SINCE THE ENERGY CALCULATIONS ARE TAKEN THE CEILING | | | FAN CREDIT, THEN THE ELECTRICAL PLAN NEEDS TO SHOW SIZE | | | OF CEILING FANS AS REQUIRED BY TABLE 13-607.1.A.1 OF | | | FBC 2004. AND, THEY NEED TO BE INSTALLED FOR | | | INSPECTION. | | | | | | ***RESPONSE: | | | REVISE SIZE OF CEILING FAN SPECIFIED FOR LIVING ROOM. | | | SEE SIZE OF ROOM ON SHEET A1 AND REVISE AS REQUIRED. | | | | | | 6- PROVIDE DRAINAGE PLAN TO SHOW COMPLIANCE WITH SEC. | | | R401.3 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | ***RESPONSE: | | | REVISE DRAINAGE PLAN SHOWN ON SITE PLAN ON SHEET A1. | | | ARROWS SHOW WATER TO BE DIVERTED TO THE ADJACENT | | | NEIGHBORS. WATER CAN'T RUN INTO ADJACENT PROPERTIES. | | | | | | 7- SHEET A1: | | | A) SPECIFY ATTIC SIZE TO SHOW COMPLIANCE WITH SEC. R807 | | | OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | ***RESPONSE: | | | 22" X 22" SIZE SHOWN DOESN'T COMPLY. REVISE AS | | | REQUIRED. | | | | | | B) DESIGN PRESSURES SPECIFIED FOR DOOR AND WINDOWS | | | DON'T CORRESPOND TO EXPOSURE "C" AS SHOWN ON BUILDING | | | INFORMATION CHART. REVISE AS REQUIRED. | | | ALSO, DESIGN PRESSURES SHOWN ON WINDOW/ DOOR SCHEDULES | | | AND EXTERIOR ELEVATIONS ON SHEETS A2 AND A3 DON'T MATCH | | | DESIGN PRESSURES SHOWN ON BUILDING INFORMATION CHART. | | | REVISE AS REQUIRED. | | | | | | ***RESPONSE: COORDINATE INFORMATION SHOWN ON OPENING | | | TABLES AND INFORMATION SHOWN ON EXTERIOR ELEVATIONS. | | | | | | C) ENTRY DOOR TO BE MIN. 3'-0" WIDE BY 6'-8" HEIGHT AS | | | REQUIRED BY SEC. R311.4.2 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | ***RESPONSE: | | | FLOOR PLAN SHOWS ENTRY DOOR OPENING TO BE 3'-2" . THIS | | | MASONRY OPENING WON'T ALLOW TO INSTALL 3'-0" WIDE DOOR. | | | REVISE AS REQUIRED. NOTE: KEEP IN MIND REQUIRED BUCK | | | SIZE. SEE PRODUCT APPROVAL. | | | | | | D) MASTER BATHROOM TYPE OF DOOR SHOWN ON FLOOR PLAN | | | DOESN'T MATCH TYPE OF DOOR SHOWN ON DOOR SCHEDULE. | | | REVISE AS REQUIRED. | | | | | | ***RESPONSE: | | | NOT ADDRESSED. | | | | | | E) SIZE OF WINDOW SPECIFIED ON WINDOW SCHEDULE DOESN'T | | | MATCH SIZE OF WINDOW SHOWN ON BUILDING INFORMATION | | | CHART. REVISE AS REQUIRED. | | | | | | ***RESPONSE: | | | NOT ADDRESSED. WINDOW SCHEDULE SHOWS H32, WHILE | | | BUILDING INFORMATION CHART SHOWS H33. REVISE AS | | | REQUIRED TO MATCH. | | | | | | F) NOTE INSIDE FOUNDATION PLAN CALLS FOR 48" MAX. | | | SPACING FOR VERTICAL REINFORCEMENT BETWEEN FILLED | | | CELLS. FOUNDATION PLAN AND FLOOR PLANS SHOW SOME AREAS | | | WHERE THE THE MAX. VERTICAL SPACING OF FILLED CELLS | | | EXCEED THE 48". REVISE AS REQUIRED. | | | | | | ***RESPONSE: | | | PLANS NOW DON'T SPECIFY THE SPACING OF VERTICAL | | | REINFORCEMENT. PROVIDE SPECIFICATIONS OR PROVIDE | | | DIMENSIONS ON FOUNDATION PLAN. | | | | | | G) REVISE BUILDING WIDTH AND BUILDING LENGTH DIMENSIONS | | | SHOWN ON BUILDING INFORMATION CHART. SEE FLOOR PLANS | | | FOR ACTUAL DIMENSIONS. | | | | | | ***RESPONSE: | | | REVISE BUILDING LENGTH. | | | | | | H) REVISE BUILDING SIDE SETBACK DIMENSIONS SHOWN ON | | | SITE PLAN. 122'? | | | | | | 8- SHEET A2: | | | A) WHERE IS BEAM B-2 SPECIFIED ON EXTERIOR CMU WALL | | | SECTION A/A2?. | | | | | | 9- SHEET A3: | | | A) REVISE NUMBER/SIZE OF NAILS AND UPLIFT LOADS SHOWN | | | ON TRUSS CONNECTORS SPECIFIED ON ROOF FRAMING PLAN. SEE | | | CONNECTOR PRODUCT APPROVAL AND REVISE AS REQUIRED. | | | | | | ***RESPONSE: | | | NOT ADDRESSED. | | | | | | B) REVISE SIZE OF STRUCTURAL BUCK SHOWN ON BUCK DETAIL | | | FOR DOOR. SEE PRODUCT APPROVAL FOR REQUIRED SIZE. ALSO, | | | DOOR FRAME NEEDS TO BE FULLY SUPPORTED ON BUCK AS | | | REQUIRED BY SEC. R613.6 OF 2004 FLORIDA RESIDENTIAL | | | CODE. PROVIDE BUCK SIZE THAT PROVIDES FULL SUPPORT TO | | | DOOR FRAME. | | | | | | 10- PLEASE, RETURN REVIEWED SET OF DRAWINGS AFTER | | | CORRECTIONS ARE DONE TO ORIGINAL DRAWINGS TO EXPEDITE | | | THE REVIEW PROCESS. | | | | | | 11- FOR INFORMATION ONLY: ENGINEER TO SEE ATTACHED COPY | | | OF FLORIDA STATUTE 553.80(2)(B) REGARDING FEES FOR | | | MULTIPLE PLAN REVIEWS. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-09 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-01-09 |
Time |
16:33 |
Sent To |
PC |
|
| Notes |
| 2009-01-09 16:56:30 | NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | | REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | | | 2- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH | | | COUNTY TO VERIFY IF IMPACT FEES ARE DUE AND HOW MUCH | | | CREDIT IS GIVEN FOR THE EXISTING HOUSE. BRING BACK | | | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | | | | | 3- NEED TO OBTAIN A SEPARATE PERMIT FOR THE DEMOLITION | | | OF THE EXISTING HOUSE. | | | | | | 4- PERMIT VALUATION DECLARED IN THE PERMIT APPLICATION | | | IS TOO LOW. VALUATION WAS UPDATED AS REQUIRED BY SEC. | | | 108.3 OF CITY AMENDMENTS TO FBC 2004 TO $128,668. | | | THEREFORE, OWES $2161.79 FOR UPDATED VALUATION AND | | | RADON FEES. | | | | | | 5- PLANS TO SPECIFY ALL LIVE AND DEAD LOADS AS REQUIRED | | | BY SEC. R301.1 AND TABLE R301.5 OF 2004 FLORIDA | | | RESIDENTIAL CODE. NOTE: ATTIC LIVE LOADS NEED TO BE | | | INCLUDED ALSO. | | | | | | 6- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) PRECAST LINTELS AS SHOWN ON PLANS. | | | | | | B) ENTRY DOOR AND KITCHEN AND BEDROOM EXTERIOR DOORS. | | | CLEARLY IDENTIFY WHICH PRODUCT APPROVAL IS FOR THE | | | ENTRY AND ALL OTHER OPENINGS. | | | ***NOTE: NOA 02-1211.10 SUBMITTED EXPIRED ON JULY 17, | | | 2008. NEED TO PROVIDE CURRENT PRODUCT APPROVAL. | | | | | | C) HURRICANE SHUTTERS: PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE ATTACHED SAMPLE. COMPLETE ALL THE | | | INFORMATION AND CLEARLY MARK ON SHUTTERS DRAWINGS | | | SPECIFIC MOUNTING CONDITIONS (EG: WALL MOUNTED, BUILD | | | OUT, ETC) AND SPECIFIC ANCHOR TYPE AND SPACING TO BE | | | USED. | | | | | | 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 8- ENERGY CALCULATIONS: OWNER/AGENT TO SIGN AND DATE | | | BOTTOM OF FORM. | | | | | | 9- SINCE THE ENERGY CALCULATIONS ARE TAKEN THE CEILING | | | FAN CREDIT, THEN THE ELECTRICAL PLAN NEEDS TO SHOW SIZE | | | OF CEILING FANS AS REQUIRED BY TABLE 13-607.1.A.1 OF | | | FBC 2004. AND, THEY NEED TO BE INSTALLED FOR | | | INSPECTION. | | | | | | 10- PROVIDE DRAINAGE PLAN TO SHOW COMPLIANCE WITH SEC. | | | R401.3 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 11- SHEET A1: | | | A) BEDROOM EGRESS WINDOWS SH-24 DON'T COMPLY WITH MIN. | | | OPENING HEIGHT OF SEC. R310.1.2 OF 2004 FLORIDA | | | RESIDENTIAL CODE. REVISE WINDOW SIZE AND WINDOW OPENING | | | DIMENSIONS SHOWN ON WINDOW SCHEDULE. | | | | | | B) SPECIFY ATTIC SIZE TO SHOW COMPLIANCE WITH SEC. R807 | | | OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | C) WINDOW BY TUB AREA ON BOTH BATHROOMS TO HAVE SAFETY | | | GLASS AS REQUIRED BY SEC. R308.4 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | D) DESIGN PRESSURES SPECIFIED FOR DOOR AND WINDOWS | | | DON'T CORRESPOND TO EXPOSURE "C" AS SHOWN ON BUILDING | | | INFORMATION CHART. REVISE AS REQUIRED. | | | ALSO, DESIGN PRESSURES SHOWN ON WINDOW/ DOOR SCHEDULES | | | AND EXTERIOR ELEVATIONS ON SHEETS A2 AND A3 DON'T MATCH | | | DESIGN PRESSURES SHOWN ON BUILDING INFORMATION CHART. | | | REVISE AS REQUIRED. | | | | | | E) CLARIFY DOOR HEIGHT OF DOORS SHOWN ON THE DOOR | | | SCHEDULE. ENTRY DOOR TO BE MIN. 3'-0" WIDE BY 6'-8" | | | HEIGHT AS REQUIRED BY SEC. R311.4.2 OF 2004 FLORIDA | | | RESIDENTIAL CODE. | | | | | | F) MASTER BATHROOM TYPE OF DOOR SHOWN ON FLOOR PLAN | | | DOESN'T MATCH TYPE OF DOOR SHOWN ON DOOR SCHEDULE. | | | REVISE AS REQUIRED. | | | | | | G) SIZE OF WINDOW SPECIFIED ON WINDOW SCHEDULE DOESN'T | | | MATCH SIZE OF WINDOW SHOWN ON BUILDING INFORMATION | | | CHART. REVISE AS REQUIRED. | | | | | | H) NOTE INSIDE FOUNDATION PLAN CALLS FOR 48" MAX. | | | SPACING FOR VERTICAL REINFORCEMENT BETWEEN FILLED | | | CELLS. FOUNDATION PLAN AND FLOOR PLANS SHOW SOME AREAS | | | WHERE THE THE MAX. VERTICAL SPACING OF FILLED CELLS | | | EXCEED THE 48". REVISE AS REQUIRED. | | | | | | I) FOUNDATION NOTE #4 CALLS FOR 2,000 PSF SOIL BEARING | | | CAPACITY, WHILE NOTE INSIDE FOUNDATION PLAN CALLS FOR | | | 2500 SOIL BEARING CAPACITY. REVISE AS REQUIRED. | | | | | | J) REVISE BUILDING WIDTH AND BUILDING LENGTH DIMENSIONS | | | SHOWN ON BUILDING INFORMATION CHART. SEE FLOOR PLANS | | | FOR ACTUAL DIMENSIONS. | | | | | | K) REVISE WIDTH OF END ZONE SHOWN ON BUILDING | | | INFORMATION CHART. SEE NOTE A ON FIGURE R301.2(8) OF | | | 2004 FLORIDA RESIDENTIAL CODE AND REVISE AS REQUIRED. | | | | | | 12- SHEET A2: | | | A) EXTERIOR C.M.U. WALL SECTION A/A2: | | | * WHERE IS THE ROOF SHEATHING THICKNESS TAKEN FROM?. | | | PROVIDE ENGINEERING CALCULATIONS SHOWING THAT SPECIFIED | | | ROOF SHEATHING THICKNESS WILL RESIST ALL THE DESIGN | | | LOADS OF SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | ** FOOTING SPECIFICATIONS DON'T MATCH FOOTING | | | SPECIFICATION SHOWN ON FOOTING SCHEDULE ON SHEET A1. | | | REVISE AS REQUIRED. | | | | | | *** SPECIFY MIN. FOOTING DEPTH AS REQUIRED BY SEC. | | | R3403.1.4 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | B) REVISE OPENINGS DESIGN PRESSURES SHOWN ON THE | | | EXTERIOR ELEVATIONS. COORDINATE WITH ITEM 11D ABOVE. | | | | | | C) INTERIOR WALL SECTION B/A2: THERE ARE TWO DIFFERENT | | | WALL FINISHES SHOWN N THE SAME DETAIL. REVISE/CLARIFY | | | AS REQUIRED. | | | | | | 13- SHEET A3: | | | A) REVISE NUMBER/SIZE OF NAILS AND UPLIFT LOADS SHOWN | | | ON TRUSS CONNECTORS SPECIFIED ON ROOF FRAMING PLAN. SEE | | | CONNECTOR PRODUCT APPROVAL AND REVISE AS REQUIRED. | | | | | | B) ROOF SHEATHING: | | | * COORDINATE TYPE AND SIZE OF NAIL SHOWN ON PLYWOOD | | | SHEATHING FASTENER SCHEDULE AND THREE DIMENSIONAL ROOF | | | PLAN. | | | NOTE: MIN. NAIL TYPE TO BE USED IS 8D RING SHANK NAILS. | | | SEE SEC. R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | ** IDENTIFY ROOF ZONE #3 ON ROOF FRAMING PLAN AND | | | SPECIFY MIN. NAILING TYPE AND SPACING USED AS REQUIRED | | | BY SEC. R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | *** ZONE 3 IS 4'-0" MIN. SEE FIGURE 301.2(8) OF 2004 | | | FLORIDA RESIDENTIAL CODE. REVISE GABLE NOTE AS | | | REQUIRED. | | | | | | 14- PLEASE, RETURN REVIEWED SET OF DRAWINGS AFTER | | | CORRECTIONS ARE DONE TO ORIGINAL DRAWINGS TO EXPEDITE | | | THE REVIEW PROCESS. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-07-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-16 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-16 |
Time |
09:56 |
Sent To |
B |
|
| Notes |
| 2009-07-16 09:56:59 | | | | | | | TO LUIS ./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-06-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-06-19 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-06-19 |
Time |
08:28 |
Sent To |
M |
|
| Notes |
| 2009-06-19 09:24:11 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | THESE COMMENTS ARE FROM THE PREVIOUS REVIEW AND WERE | | | NOT RESPONDED TO.SHEET A2***THESE COMMENTS ARE STILL | | | NOT ADRESSED AS OF THE JUNE 2ND RESUBMITTAL.. | | | | | | 9} CIRCUIT #12 IS FOR A DISPOSAL, NOT IN THE LOAD | | | CALCULATION.220.83(B)(3). | | | | | | THESE COMMENTS ARE GENERATED BY CHANGES MADE TO THE | | | PLANS: | | | | | | 1} THE PLAN INDICATES A MAIN DISCONNECT (TWO ACTUALLY) | | | AT THE METER, THERE IS NO DISCONNECT ON THE RISER | | | DIAGRAM RISER DIAGRAM, CORRELATE AND INDICATE THE | | | INTENT OF THE DESIGNER.DUE TO THE METER LOCATION, A | | | DISCONNECT IS REQUIRED PER 230.70 | | | | | | 2}THE PANEL SHOWN ON THE RISER IS RATED AT 200 AMPS | | | WITH A225 AMP MAIN IN VIOLATION OF 408.36(A) LIGHTING | | | AND APPLIANCE BRANCH-CIRCUIT PANELBOARD INDIVIDUALLY | | | PROTECTED EACH LIGHTING AND APPLIANCE BRANCH-CIRCUIT | | | PANELBOARD SHALL BE INDIVIDUALLY PROTECTED ON THE | | | SUPPLY SIDE BY NOT MORE THAN TWO MAIN CIRCUIT BREAKERS | | | OR TWO SETS OF FUSES HAVING A COMBINED RATING NOT | | | GREATER THAN THAT OF THE PANELBOARD. ALSO THE | | | CONDUCTORS ARE RATED FOR 200 AMPS, 3/0 WOULD BE | | | REQUIRED FOR 225 AMPS. | | | | | | 3} THE PANEL SCHEDULE CIRCUITS 2&4 FOR THE AHU SHOWS A | | | 60 AMP BREAKER FOR A 47 AMP LOAD IN VIOLATION OF 240.4. | | | THE HEAT LOAD IS STATED TO BE 7500 WATTS IN THE LOAD | | | CALCULATIONS. 7500/240X125%=39 AMPS THEREFORE A 40 AMP | | | BREAKER WOULD BE USED. 240.4(B). | | | | | | THE FOLLOWING COMMENTS ARE IN REGARD TO THE PANEL | | | SCHEDULE: | | | | | | 4} CIRCUITS #1 & 3 HAVE NO OVERCURRENT RATING FOR THE | | | OCP.A/C CIRCUIT. | | | | | | 5} THERE IS A GARAGE GFI CIRCUIT #15 LISTED, BUT NO | | | GARAGE SHOWN ON THE PLAN. 408.4 | | | | | | 6} CIRCUIT #18 LISTS THE "UTIL" ON WITH THE BATH | | | CIRCUIT IN VIOLATION OF 210.11(C)(3) " BATHROOM BRANCH | | | CIRCUITS IN ADDITION TO THE NUMBER OF BRANCH CIRCUITS | | | REQUIRED BY OTHER PARTS OF THIS SECTION, AT LEAST ONE | | | 20-AMPERE BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY | | | BATHROOM RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE | | | NO OTHER OUTLETS." | | | | | | PLEASE REMOVE OLD SHEETS, INSERT NEW ONES, SUBMIT OLD | | | SHEETS TO EXPEDITE AND SUBMIT WRITTEN RESPONSE TO THE | | | COMMENTS MADE IN THIS REVIEW. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-02-26 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-02-26 |
Time |
14:12 |
Sent To |
M |
|
| Notes |
| 2009-02-26 14:37:44 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | THESE COMMENTS ARE FROM THE PREVIOUS REVIEW AND WERE | | | NOT RESPONDED TO.SHEET A2.. | | | | | | 9} CIRCUIT #12 IS FOR A DISPOSAL, NOT IN THE LOAD | | | CALCULATION.220.83(B)(3). | | | | | | THESE COMMENTS ARE GENERATED BY CHANGES MADE TO THE | | | PLANS: | | | | | | 1} THE PLAN INDICATES A MAIN DISCONNECT (TWO ACTUALLY) | | | AT THE METER, THERE IS NO DISCONNECT ON THE RISER | | | DIAGRAM RISER DIAGRAM, CORRELATE AND INDICATE THE | | | INTENT OF THE DESIGNER.DUE TO THE METER LOCATION, A | | | DISCONNECT IS REQUIRED PER 230.70 | | | | | | 2}THE PANEL SHOWN ON THE RISER IS RATED AT 200 AMPS | | | WITH A225 AMP MAIN IN VIOLATION OF 408.36(A) LIGHTING | | | AND APPLIANCE BRANCH-CIRCUIT PANELBOARD INDIVIDUALLY | | | PROTECTED EACH LIGHTING AND APPLIANCE BRANCH-CIRCUIT | | | PANELBOARD SHALL BE INDIVIDUALLY PROTECTED ON THE | | | SUPPLY SIDE BY NOT MORE THAN TWO MAIN CIRCUIT BREAKERS | | | OR TWO SETS OF FUSES HAVING A COMBINED RATING NOT | | | GREATER THAN THAT OF THE PANELBOARD. ALSO THE | | | CONDUCTORS ARE RATED FOR 200 AMPS, 3/0 WOULD BE | | | REQUIRED FOR 225 AMPS. | | | | | | 3} THE PANEL SCHEDULE CIRCUITS 2&4 FOR THE AHU SHOWS A | | | 60 AMP BREAKER FOR A 47 AMP LOAD IN VIOLATION OF 240.4. | | | THE HEAT LOAD IS STATED TO BE 7500 WATTS IN THE LOAD | | | CALCULATIONS. 7500/240X125%=39 AMPS THEREFORE A 40 AMP | | | BREAKER WOULD BE USED. 240.4(B). | | | | | | THE FOLLOWING COMMENTS ARE IN REGARD TO THE PANEL | | | SCHEDULE: | | | | | | 4} CIRCUITS #1 & 3 HAVE NO OVERCURRENT RATING FOR THE | | | OCP.A/C CIRCUIT. | | | | | | 5} THERE IS A GARAGE GFI CIRCUIT #15 LISTED, BUT NO | | | GARAGE SHOWN ON THE PLAN. 408.4 | | | | | | 6} CIRCUIT #18 LISTS THE "UTIL" ON WITH THE BATH | | | CIRCUIT IN VIOLATION OF 210.11(C)(3) " BATHROOM BRANCH | | | CIRCUITS IN ADDITION TO THE NUMBER OF BRANCH CIRCUITS | | | REQUIRED BY OTHER PARTS OF THIS SECTION, AT LEAST ONE | | | 20-AMPERE BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY | | | BATHROOM RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE | | | NO OTHER OUTLETS." | | | | | | PLEASE REMOVE OLD SHEETS, INSERT NEW ONES, SUBMIT OLD | | | SHEETS TO EXPEDITE AND SUBMIT WRITTEN RESPONSE TO THE | | | COMMENTS MADE IN THIS REVIEW. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-19 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-12-19 |
Time |
06:36 |
Sent To |
M |
|
| Notes |
| 2008-12-19 08:07:37 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | ALL COMMENTS RELATE TO SHEET2, UNLESS OTHERWISE NOTED. | | | ALL CODE ARTICLES REFERENCED ARE 2005 NEC UNLESS | | | OTHERWISE NOTED. | | | | | | 1} THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL | | | COST OF LABOR AND MATERIAL. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES PER 108.3 FBC AS | | | AMENDED. | | | | | | A PERMIT SHALL NOT BE ISSUED UNTIL FEES AUTHORIZED | | | UNDER SECTION 553.80, FLORIDA STATUTES, HAVE BEEN PAID. | | | 108.1 FBC. | | | | | | ADJUST THE VALUE AT THE PERMIT CLERK?S DESK, AND PAY | | | THE DIFFERENCE IN FEES PRIOR TO RESUBMITTING. | | | | | | 2} INDICATE THE USE FOR THE 2#2 CU CONDUCTORS RAN WITH | | | THE SERVICE CONDUCTORS TO THE MAIN DISCONNECT, IF SOME | | | SORT OF GROUNDS THEY ARE IN VIOLATION OF 250.6. | | | | | | 3} THE 2/0 CU GROUND TO THE PANEL FROM THE DISCONNECT | | | IS NOT A VIOLATION BUT ONLY NEEDS TO BE #6. IF NOT | | | CHANGED PRIOR TO PERMITTING A REVISION WILL BE REQUIRED | | | LATER.. | | | | | | 4} THE NUMBER OF CONDUCTORS FROM THE DISCONNECT TO THE | | | PANEL IS IN VIOLATION OF 362.22 FOR CONDUCTOR FILL. | | | | | | 5} THE RISER INDICATES BREAKERS FOR TWO A/C UNITS, BUT | | | ONLY ONE IS LISTED IN THE PANEL SCHEDULE AND ON THE | | | CALC'S. CORRELATE SAME. | | | | | | 6} 250.52(A)(3) CONCRETE-ENCASED ELECTRODE AN ELECTRODE | | | ENCASED BY AT LEAST 50 MM (2 IN.) OF CONCRETE, LOCATED | | | WITHIN AND NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR | | | FOOTING THAT IS IN DIRECT CONTACT WITH THE EARTH, | | | CONSISTING OF AT LEAST 6.0 M (20 FT) OF ONE OR MORE | | | BARE OR ZINC GALVANIZED OR OTHER ELECTRICALLY | | | CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT | | | LESS THAN 13 MM ( 1/ 2 IN.) IN DIAMETER, OR CONSISTING | | | OF AT LEAST 6.0 M (20 FT) OF BARE COPPER CONDUCTOR NOT | | | SMALLER THAN 4 AWG. REINFORCING BARS SHALL BE PERMITTED | | | TO BE BONDED TOGETHER BY THE USUAL STEEL TIE WIRES OR | | | OTHER EFFECTIVE MEANS. INDICATE THIS ON THE RISER | | | DIAGRAM. | | | | | | 7} THE CONDUCTORS FOR CIRCUIT # 1,3 A/C ARE DIFFERENT | | | SIZES,? THE #10 IS IN VIOLATION OF 310.16 FOR A 32 AMP | | | LOAD THATS LISTED. | | | | | | 8} CIRCUITS 5&7 FOR THE WATER HEATER LISTS #6 CU | | | CONDUCTORS ON A 30 AMP BREAKER, NO CODE ARTICLE BUT | | | PHYSICALLY WON'T FIT. #10CU IS ALL THATS REQUIRED FOR A | | | 30 AMP BREAKER. THE LOAD AT 19 AMPS IS ALSO INCORRECT | | | FOR A 4500 WATT LOAD.422.13 -4500/240=18.45X1.25%=23 | | | AMPS. | | | | | | 9} CIRCUIT #12 IS FOR A DISPOSAL, NOT IN THE LOAD | | | CALCULATION.220.83(B)(3). | | | | | | 10} THERE ARE NO SMALL APPLIANCE CIRCUITS LISTED IN THE | | | PANEL SCHEDULE (ONE KITCHEN GFI?). 210.11(C)(3) | | | | | | 11} ONE WALL SWITCH?CONTROLLED LIGHTING OUTLET SHALL BE | | | INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR SIDE | | | OF OUTDOOR ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS. | | | 210.70(A)(2)((B).BACK DOOR. | | | | | | 12} THE DISCONNECT LOCATION SHOWN FOR THE CONDENING | | | UNIT IS IN VIOLATION OF 110.26 CLEARANCE. | | | | | | 13} A RECEPTACLE IS REQUIRED IN THE MASTER AND THE | | | ADJOINING (UNLABELED) BEDROOM PER 210.52(A)(1)&(2). | | | | | | 14} A RECEPTACLE IS REQUIRED IN THE HALL PER 210.52(H). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-10-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-08 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-08 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2009-10-08 09:16:17 | SENT TO PLUMBING (KS). |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-07-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-07-15 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-07-15 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2009-07-15 10:29:04 | GAVE TO JULIO, PLANS ARE TO BE HAND ROUTED BY ME LM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-06-03 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-06-03 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2009-06-03 11:38:33 | SENT TO BOX R7. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-20 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-20 |
Time |
10:26 |
Sent To |
Z |
|
| Notes |
| 2009-02-20 10:26:25 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-01-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-01-09 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-12-15 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2008-12-15 16:32:37 | TO "SFR" "Z" |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2009-07-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-07-23 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-07-23 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2009-07-23 14:44:24 | SEE OLD SHEET A-1, SIGNED BY WILLIE ON 2/9/09, $0.00 | | | FEES. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-06-09 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-06-09 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2009-06-09 17:05:08 | ***LANDSCAPE REVIEW PASSED WITH PROVISO*** | | | | | | PROVIDE SCREENING FOR AIR CONDITIONING UNIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462, |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-02-24 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-02-24 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-02-24 |
Time |
09:18 |
Sent To |
Z |
|
| Notes |
| 2009-02-24 09:30:36 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. LANDSCAPE PLAN SHALL SHOW THE RIGHT-OF-WAY AND | | | STREET. A PLANT LIST SHALL APPEAR ON THE PLAN WITH THE | | | PLANT NAMES, SIZES, QUANTITY AND SPACING. A NORTH ARROW | | | SHALL BE ON PLAN. SHOW ALL EXISTING TREES, UTILITIES, | | | OVERHANGING TREE LIMBS FROM NEIGHBORING PROPERTY AND | | | ANYTHING ELSE THAT COULD INTERFERE WITH THE PROPOSED | | | LANDSCAPING. | | | | | | 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE | | | XERISCAPE DESIGN OPTIONS. | | | | | | 3. PROVIDE A COST ESTIMATE THAT INCLUDES THE TOTAL COST | | | OF ALL LANDSCAPE MATERIRALS AND LABOR. | | | | | | 4. AN IRRIGATION PERMIT IS REQUIRED. THE IRRIGATION | | | SYSTEM SHALL PROVIDE 100% COVERAGE TO ALL LANDSCAPED | | | AREAS, INCLUDING THE RIGHT-OF-WAY. | | | | | | 5. PURSUANT TO SECTION 94-444(B), GARBAGE CONTAINERS, | | | GROUND LEVEL AIR CONDITIONING UNITS AND ALL OTHER | | | MECHANICAL EQUIPMENT SHALL BE SCREENED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-07-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-16 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-16 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-06-22 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-06-22 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2009-06-22 14:19:45 | SAME COMMENTS AS 3/24/2009 REVIEW | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-03-24 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-03-24 |
Time |
10:04 |
Sent To |
P |
|
| Notes |
| 2009-03-24 10:15:36 | PLAN DENIED | | | 1) PLEASE PROVIDE GRILL SIZE ON PLANS . | | | 2) PLEASE PROVIDE RETURN AIR SIZE ON PLANS . | | | 3) PLEASE SHOW BATHROOM EXHAUEST AND TERMINATION ON | | | MECHANICAL PLANS . | | | 4) PLEASE SHOW DRYER EXHAUST AND SIZE ON PLANS . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-12-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-22 |
Time |
19:07 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-22 |
Time |
18:58 |
Sent To |
P |
|
| Notes |
| 2008-12-22 19:07:49 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. ENERGY CALCULATIONS SHALL BE SIGNED BY THE | | | PREPARER/OWNER IN ACCORDANCE WITH FBCB 13-103.1.2. | | | | | | 2. PLANS DO NOT SHOW THE SIZE OF RETURN AIR TRANSFER | | | DUCTS. SHOW SIZE OF TRANSFER DUCTS AND 1" UNDERCUT ON | | | BEDROOM DOORS TO DEMONSTRATE COMPLIANCE WITH THE | | | EXCEPTION UNDER FBCR M1602.4. | | | | | | 3. PLEASE SHOW SIZE AND LOCATION OF DRYER AND BATHRROM | | | EXHAUST DUCTS, INCLUDING TERMINATION LOCATIONS FBCR | | | M1501.1 AND FBCR M1506.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-10-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-14 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-14 |
Time |
12:28 |
Sent To |
B |
|
| Notes |
| 2009-10-14 12:29:10 | REVISION OK -- SHT A3 SANITARY RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-17 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-17 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2009-07-17 16:21:59 | PASSED/PROVISO: A REVISION IS REQUIRED FOR THE SANITARY | | | RISER DIAGRAM DELETING THE 3RD BATHROOM AND SHOWING THE | | | LAV ARM IN BATHROOM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2009-06-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-15 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-15 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2009-06-15 16:19:03 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 RESIDENTIAL | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | ******FROM PREVIOUS REVIEWS: | | | | | | 1. OK | | | | | | 2. SHT A3 SANITARY ISOMETRIC RISER DIAGRAM DOES NOT | | | REFLECT THE FIXTURE LAYOUT ON THE FLOOR PLAN, NOR DOES | | | IT MEET CODE. MOST PIPE SIZES ARE NOT SHOWN. SHOW ALL | | | PIPE SIZES TO VERIFY COMPLIANCE WITH TABLES 709.1, | | | 710.1(1), 710.1(2) & 916.1. | | | ****RESPONSE NOTED, BUT THE RISER DIAGRAM STILL DOES | | | NOT REFLECT THE FLOOR PLAN. THE BUILDING DRAIN ENTERS | | | FROM THE SOUTH AND TURNS EAST TO PICK UP THE WASH | | | MACHINE, TURNS EAST TO PICK UP THE KITCHEN SINK AND | | | THEN TURNS EAST TO PICK UP EACH BATHROOM GROUP. THE | | | RISER SHOWS THE BATHROOM GROUPS EITHER GOING TO THE | | | WEST OR STRAIGHT TO THE SOUTH. PLEASE CORRELATE. ALSO | | | AS SHOWN THE TUBS ARE NOT VENTED. SECTION 901.2.1. | | | ******NO RESPONSE, COMMENT NOT ADDRESSED. (SAME SHEET | | | RESUBMITTED). | | | | | | 2A. OK | | | 2B. OK | | | | | | 2C. SUBMIT A SANITARY RISER DIAGRAM THAT REFLECTS THE | | | RED-LINE PIPING INDICATED ON SHT A3 OF ONE SET OF PLAN | | | SHOWING ALL PIPE SIZES, TRAPS & VENTS AS REQUIRED IN | | | CHAPTERS 7, 9 & 10. | | | ****RESPONSE NOTED, BUT THE RED-LINE DRAWING WAS | | | DISREGARDED. SEE NEW RED-LINE EXAMPLE OF CODE COMPLIANT | | | RISER SECTION THAT REFLECTS THE FLOOR PLAN. | | | ******NO RESPONSE, COMMENT NOT ADDRESSED. (SAME SHEET | | | RESUBMITTED). | | | | | | | | | ********NEW COMMENT******** | | | | | | 1B. MINIMUM 2 SETS OF PLANS SHALL BE SUBMITTED WITH | | | EACH APPLICATION FOR PERMIT. SECTION 106.1. ONLY ONE | | | SET OF PLANS WAS SUBMITTED FOR REVIEW. SOME SAME SHEETS | | | FROM PREVIOUS REVIEW. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2009-03-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-03-27 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-03-27 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2009-03-27 15:05:49 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 RESIDENTIAL | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | | | | 2. SHT A3 SANITARY ISOMETRIC RISER DIAGRAM DOES NOT | | | REFLECT THE FIXTURE LAYOUT ON THE FLOOR PLAN, NOR DOES | | | IT MEET CODE. MOST PIPE SIZES ARE NOT SHOWN. SHOW ALL | | | PIPE SIZES TO VERIFY COMPLIANCE WITH TABLES 709.1, | | | 710.1(1), 710.1(2) & 916.1. | | | ****RESPONSE NOTED, BUT THE RISER DIAGRAM STILL DOES | | | NOT REFLECT THE FLOOR PLAN. THE BUILDING DRAIN ENTERS | | | FROM THE SOUTH AND TURNS EAST TO PICK UP THE WASH | | | MACHINE, TURNS EAST TO PICK UP THE KITCHEN SINK AND | | | THEN TURNS EAST TO PICK UP EACH BATHROOM GROUP. THE | | | RISER SHOWS THE BATHROOM GROUPS EITHER GOING TO THE | | | WEST OR STRAIGHT TO THE SOUTH. PLEASE CORRELATE. ALSO | | | AS SHOWN THE TUBS ARE NOT VENTED. SECTION 901.2.1. | | | | | | 2A. OK | | | 2B. OK | | | | | | 2C. SUBMIT A SANITARY RISER DIAGRAM THAT REFLECTS THE | | | RED-LINE PIPING INDICATED ON SHT A3 OF ONE SET OF PLAN | | | SHOWING ALL PIPE SIZES, TRAPS & VENTS AS REQUIRED IN | | | CHAPTERS 7, 9 & 10. | | | ****RESPONSE NOTED, BUT THE RED-LINE DRAWING WAS | | | DISREGARDED. SEE NEW RED-LINE EXAMPLE OF CODE COMPLIANT | | | RISER SECTION THAT REFLECTS THE FLOOR PLAN. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-12-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-24 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-24 |
Time |
13:13 |
Sent To |
B |
|
| Notes |
| 2008-12-24 13:46:59 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 RESIDENTIAL | | | | | | 1. SHT A1 BUILDING CODE/DESIGN CRITERIA SHALL ALSO | | | INCLUDE THE 2007 AMENDMENTS TO THE FBC-2004. | | | | | | 2. SHT A3 SANITARY ISOMETRIC RISER DIAGRAM DOES NOT | | | REFLECT THE FIXTURE LAYOUT ON THE FLOOR PLAN, NOR DOES | | | IT MEET CODE. MOST PIPE SIZES ARE NOT SHOWN. SHOW ALL | | | PIPE SIZES TO VERIFY COMPLIANCE WITH TABLES 709.1, | | | 710.1(1), 710.1(2) & 916.1. | | | | | | 2A. THE WASH MACHINE, KITCHEN SINK & BOTH LAVS ARE NOT | | | VENTED AS SHOWN. SECTION 901.2. | | | | | | 2B. THE WASH MACHINE REQUIRES A STANDPIPE PER SECTIONS | | | 1002.1 THAT COMPLIES WITH SECTION 802.4. (MINIMUM 18" & | | | MAXIMUM 42") & ALSO REQUIRES A CLEANOUT MINIMUM 4 FEET | | | ABOVE THE FLOOR PER SECTION 708.9. | | | | | | 2C. SUBMIT A SANITARY RISER DIAGRAM THAT REFLECTS THE | | | RED-LINE PIPING INDICATED ON SHT A3 OF ONE SET OF PLAN | | | SHOWING ALL PIPE SIZES, TRAPS & VENTS AS REQUIRED IN | | | CHAPTERS 7, 9 & 10. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-07-23 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-07-23 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-07-23 |
Time |
10:48 |
Sent To |
B |
|
| Notes |
| 2009-07-23 11:01:08 | PASSED WITH PROVISO: | | | | | | APPLICANT SHALL OBTAIN A RIGHT-OFWAY PERMIT AND | | | DRIVEWAY PERMIT PRIOR TO FRAMING INSPECTION. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | ROUTED BACK TO LM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-06-09 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-06-09 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2009-06-09 17:46:55 | PLANNING AND ZONING DEPT: ***ZONING FAILED - 2ND | | | RESUB*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PLEASE SUBMIT 2 SETS OF PLANS. ONLY ONE SET WAS | | | PROVIDED. | | | | | | REPEAT COMMENTS (2ND NOTICE): | | | | | | 3. PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE | | | SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE | | | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT | | | BUILDING FACADE). | | | | | | THE CALCULATIONS SHOWN ON SHEET A-1 ARE FOR THE ENTIRE | | | LOT. THE CALCULATIONS REQUESTED ARE FOR THE FRONT YARD | | | AREA. PLEASE SUBMIT FOR A DRIVEWAY UNDER SEPARATE | | | PERMIT. | | | | | | IS THE DRIVEWAY APPROACH BEING WIDENED? IF YES, A | | | RIGHT-OF-WAY PERMIT WILL NEED TO BE ACQUIRED FROM THE | | | CITY'S ENGINEERING DEPARTMENT (561.494.1040), FOR THE | | | PROPOSED WIDENING OF THE APPROACH EXTENSION AS | | | PREVIOUSLY REQUESTED. NOTE, IF APPLICABLE, **DO NOT | | | SUBMIT FOR THE DRIVEWAY PERMIT WITHOUT THIS APPROVAL*** | | | | | | 4. THE SIDE SETBACK DIMENSIONS SHOWN ON SHEET A-1 ARE | | | NOT CLEAR. PLEASE CLARIFY. | | | | | | 5. THE LANDSCAPE PLAN THAT WAS PROVIDED IS FOR ANOTHER | | | PROPERTY. PLEASE SUBMIT A LANDSCAPE PLAN FOR THE | | | SUBJECT SITE. | | | | | | PLEASE REFER TO PREVIOUS COMMENTS | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | PLACED BACK IN R7 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-02-26 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-02-26 |
Time |
10:53 |
Sent To |
E |
|
| Notes |
| 2009-02-26 11:07:46 | PLANNING AND ZONING DEPT: ***ZONING FAILED - 1ST | | | RESUB*** | | | | | | REPEAT COMMENTS: | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE | | | SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE | | | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT | | | BUILDING FACADE). | | | | | | THE CALCULATIONS SHOWN ON SHEET A-1 ARE FOR THE ENTIRE | | | LOT. THE CALCULATIONS REQUESTED ARE FOR THE FRONT YARD | | | AREA. PLEASE SUBMIT FOR A DRIVEWAY UNDER SEPARATE | | | PERMIT. | | | | | | IS THE DRIVEWAY APPROACH BEING WIDENED? IF YES, A | | | RIGHT-OF-WAY PERMIT WILL NEED TO BE ACQUIRED FROM THE | | | CITY'S ENGINEERING DEPARTMENT (561.494.1040), FOR THE | | | PROPOSED WIDENING OF THE APPROACH EXTENSION AS | | | PREVIOUSLY REQUESTED. NOTE, IF APPLICABLE, **DO NOT | | | SUBMIT FOR THE DRIVEWAY PERMIT WITHOUT THIS APPROVAL*** | | | | | | NEW COMMENTS: | | | 3. THE SIDE SETBACK DIMENSIONS SHOWN ON SHEET A-1 ARE | | | NOT CLEAR. PLEASE CLARIFY. | | | | | | 4. THE LANDSCAPE PLAN THAT WAS PROVIDED IS FOR ANOTHER | | | PROPERTY. PLEASE SUBMIT A LANDSCAPE PLAN FOR THE | | | SUBJECT SITE. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-12-16 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-12-16 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-12-16 |
Time |
11:54 |
Sent To |
I |
|
| Notes |
| 2008-12-16 13:29:00 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK | | | EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS | | | "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | 3. PURSUANT TO THE ZLDR, SECTION 94-482: REQUIRED | | | OFF-STREET PARKING SPACES FOR LESS THAN FOUR | | | RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE | | | PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED | | | PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE | | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | | YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN | | | THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH, | | | NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION | | | 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO | | | PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE. | | | | | | PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE | | | SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE | | | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT | | | BUILDING FACADE). | | | | | | ADDITIONALLY, A RIGHT-OF-WAY PERMIT WILL NEED TO BE | | | ACQUIRED FROM THE CITY'S ENGINEERING DEPARTMENT | | | (561.494.1040), FOR THE PROPOSED APPROACH EXTENSION. | | | ***IMPORTANT - DO NOT RESUBMIT WITHOUT THIS APPROVAL*** | | | | | | 4. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR, | | | SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | WINDOW AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN | | | 18 INCHES INTO A REQUIRED SIDE SETBACK. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|