Plan Review Details - Permit 08120122
| Plan Review Stops For Permit 08120122 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
jnguyen |
Date |
2008-12-08 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jnguyen |
Date |
2008-12-08 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2008-12-08 10:09:38 | I TALKED TO THE CONTRACTOR, STEPHEN KILTON OF JUST TILE | | | & MARBLE, INC. & HE NOTED TO ME THAT THE ADDRESS ON | | | THIS PERMIT IS CORRECT AS 550 OKEECHOBEE BLVD # 1601. I | | | VERIFIED THAT THIS PERMIT IS BEING APPLIED TO THE RIGHT | | | PCN# 74434321170030000, UNIT RECORD 0010 - 550 | | | OKEECHOBEE BLVD # 1601. MR. KILTON ACKNOWLEDGED TO ME | | | THAT THIS PERMIT# 08120122 IS FOR BOTH AN INSTALLATION | | | OF A 6MM CORK AS A SOUND SUPPRESSANT & A TRAVERTINE | | | (WHICH IS EXCLUSIVE TO THIS PERMIT# 08120122, NOT | | | PERMIT# 08120119). HE SAID IT IS IMPERATIVE THAT WE | | | PROCESS THIS APPLICATION AS QUICKLY AS POSSIBLE BECAUSE | | | THE OWNER, MAURICIO MORALES WOULD LIKE THE WORK DONE | | | BEFORE CHRISTMAS. MR. KILTON OF JUST TILE & MARBLE, | | | INC. CAN BE REACHED AT (561) 272-4900 FOR ADDITIONAL | | | CLARIFICATION PURPOSES. | | 2008-12-05 10:35:09 | ROUTED COPY OF APPLICATION TO ADDRESSING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-12-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-18 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-18 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-08 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-08 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2008-12-08 11:16:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | | | | 1. PROVIDE INFORMATION REGARDING THE TRAVERTINE | | | THICKNESS AND APPROXIMATE WEIGHT PSF, FBC16. | | | | | | 2. AN ENGINEERING ANALYSIS IS REQUIRED TO DEMONSTRATE | | | THAT THE EXISTING SLAB CAN ACCOMODATE THE ADDITIONAL | | | ANTICIPATED DEAD LOAD, FBC16. TWO CITY PLAZA MANAGEMENT | | | IS WORKING TO GET AN ENGINEER'S LETTER ON FILE. | | | HOWEVER, THIS HAS NOT BEEN DONE AT THIS TIME. PLEASE | | | PROVIDE ENGINEERING. IF THIS IS NOT POSSIBLE, THIS | | | PERMIT CAN BE ISSUED WITH PROVISO THAT THE LETTER WILL | | | BE SUBMITTED PRIOR TO FINAL INSPECTION. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-16 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-16 |
Time |
10:03 |
Sent To |
B |
|
| Notes |
| 2008-12-16 10:03:41 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-08 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-05 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2008-12-05 15:56:23 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |