Plan Review Details - Permit 08110572
Plan Review Stops For Permit 08110572
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-30 Cont ID  
Sent By shill Date 2008-12-30 Time 16:19 Rev Time 0.00
Received By shill Date 2008-12-30 Time 16:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-12-11 Cont ID  
Sent By shill Date 2008-12-11 Time 08:38 Rev Time 0.00
Received By shill Date 2008-12-11 Time 08:38 Sent To  
Notes
2008-12-11 08:48:01****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. THE APPLICATION STATES THAT WINDOWS WILL BE
 REPLACED. PROVIDE A FLOOR PLAN SHOWING: WINDOW AND DOOR
 LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE
 EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE
 FOR BEDROOMS, FBC R310, FBC EB 505.1.
  
 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 THE WINDOWS, FAC9B72.
  
 3. FOR THE SHUTTERS, COMPLETE THE ATTACHED INSTALLATION
 SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE
 COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301,
 FBC1609. TWO SETS REQUIRED.
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF. THE INSTALLATION SCHEDULE SHOULD
 CORRELATE WITH THE FLOOR PLAN.
  
 4. SHOW EMERGENCY MEANS OF ESCAPE, FBC R310.4.
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2008-11-26 Cont ID  
Sent By swurafti Date 2008-11-26 Time 14:30 Rev Time 0.00
Received By swurafti Date 2008-11-26 Time 14:30 Sent To  
Notes
2008-11-26 14:30:53HISTORIC APPROVED BY JPAPA

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-12-26 Cont ID  
Sent By adarroug Date 2008-12-26 Time 11:14 Rev Time 0.00
Received By adarroug Date 2008-12-26 Time 11:14 Sent To B
Notes
2008-12-26 11:14:42TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-09 Cont ID  
Sent By adarroug Date 2008-12-09 Time 15:01 Rev Time 0.00
Received By adarroug Date 2008-12-09 Time 15:01 Sent To B
Notes
2008-12-09 15:02:05TO "MISC"BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-12-11 Cont ID  
Sent By shill Date 2008-12-11 Time 08:48 Rev Time 0.00
Received By shill Date 2008-11-26 Time 16:48 Sent To  
Notes
2008-11-26 16:48:14TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status N Date 2008-12-08 Cont ID  
Sent By mcruz Date 2008-12-08 Time 16:59 Rev Time 0.00
Received By mcruz Date 2008-12-08 Time 16:56 Sent To  
Notes
2008-12-08 16:59:35*ZONING REVIEW NOT REQUIRED: THE VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.