Plan Review Details - Permit 08110567
Plan Review Stops For Permit 08110567
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-08 Cont ID  
Sent By shill Date 2008-12-08 Time 16:48 Rev Time 0.00
Received By shill Date 2008-12-08 Time 16:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-11-26 Cont ID  
Sent By shill Date 2008-11-26 Time 14:18 Rev Time 0.00
Received By shill Date 2008-11-26 Time 14:18 Sent To  
Notes
2008-11-26 14:28:12****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. SEE PAGE 7 OF THE PRODUCT APPROVAL. BOTH "OPPOSING
 CENTERMATES" AND "SYMMETRICAL CENTERMATES" WAS
 HIGHLIGHTED. CLARIFY WHICH OPTION WILL BE USED, AS THIS
 DETERMINES SHUTTER TO GLASS SEPARATION.
  
 2. THE SHUTTER CONNECTION MOUNTING TYPE SHOULD
 CORRELATE WITH THE ANCHOR CHARTS; FOR INSTANCE, WALL
 MOUNT 1 (W/1" BO), SEE SHEET 10 OF THE PRODUCT
 APPROVAL.
  
 3. PLEASE EXPLAIN HOW YOU'VE ARRIVED AT THE SHUTTER
 SPAN LENGTHS. IT APPEARS THAT A WALL MOUNT IS USED FOR
 OPENING 1, SO THE SPAN SHOULD BE LARGER THAN THE
 OPENING SIZE.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-11-26 Cont ID  
Sent By shill Date 2008-11-26 Time 14:18 Rev Time 0.00
Received By shill Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved