Plan Review Details - Permit 08110498
| Plan Review Stops For Permit 08110498 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-12-12 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-12-12 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-12-09 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-12-09 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2008-12-09 08:40:59 | 2004 FBC W/2007 REVISIONS | | | REPLACE WINDOWS | | | | | | DENIED BY BUILDING | | | | | | 1) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | 'CUSTOM WINDOW SYSTEMS, INC.' CASEMENT AND SINGLE HUNG | | | WINDOWS ARE FOR THE 2007 CODE VERSION WHICH HAS NOT | | | BEEN ADOPTED. THE APPLICABLE CODE IS THE 2004 FBC. | | | PLEASE SUBMIT THE PRODUCT APPROVALS FOR THESE PRODUCTS | | | THAT REFERENCE THE 2004 CODE. FAC RULE 9B-72. | | | | | | 2) SUBMIT TWO COPIES OF A KEY PLAN THAT SPECIFIES THE | | | LOCATION, SIZE AND TYPE OF WINDOWS. INDICATE THE | | | WINDOWS THAT WILL BE MULLED TOGETHER. FBC R301.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-12-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-11 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-11 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2008-12-11 08:27:24 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-08 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-08 |
Time |
15:16 |
Sent To |
B |
|
| Notes |
| 2008-12-08 15:17:17 | TO "MISC" BOX#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-12-09 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-11-25 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2008-11-25 11:12:16 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-12-08 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-12-08 |
Time |
13:30 |
Sent To |
I |
|
| Notes |
| 2008-12-08 13:32:31 | *ZONING REVIEW NOT REQUIRED: THE VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|
|