Plan Review Details - Permit 08110476
Plan Review Stops For Permit 08110476
Review Stop G GAS REVIEW
Rev No 3 Status P Date 2008-12-09 Cont ID  
Sent By kstevens Date 2008-12-09 Time 12:33 Rev Time 0.00
Received By kstevens Date 2008-12-09 Time 12:33 Sent To  
Notes
2008-12-09 12:34:19PASSED PROVISO: -- FIELD INSPECTOR TO VERIFY LENGHT OF
 RISERS AT POOL HEATER & GRILL.

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2008-12-03 Cont ID  
Sent By kstevens Date 2008-12-03 Time 10:05 Rev Time 0.00
Received By kstevens Date 2008-12-03 Time 10:05 Sent To  
Notes
2008-12-03 10:18:48DENIED
 REFERENCE:
 FBC-2004 FUEL GAS
 FBC-2004 CHAPTER 1
  
 A. SUBMIT THE FOLLOWING INFORMATION FOR PERMIT:
  
 ****FROM PREVIOUS REVIEW:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE. -- NOT ALL LENGTHS INDICATED. (SEE
 HIGHLIGHTED SECTIONS OF PIPE).
 ****RESPONSE NOTED, BUT COMMENTS NOT ADDRESSED. NOT ALL
 LENGHTS WERE INDICATED AS REQUESTED. PLEASE INDICATE
 HOW THE DROPS FROM THE METER AND THE RISERS FROM
 UNDERGROUND CAN BE 1 FOOT WHEN THERE IS A REQUIREMENT
 FOR MINIMUM BURIAL DEPTH TO BE 1 FOOT. SECTION 404.9.
 SUBMIT LENGTHS OF PIPE THAT REFLECT THE INSTALLATION OF
 THE PIPE AND SHOW THE LENGHT FOR EACH CUT SECTION.
  
 2. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 ****NO RESPONSE, COMMENT NOT ADDRESSED.
  
 3. OK
  
 ****NEW COMMENT****
  
 1B. THE PIPE SIZE FROM THE METER SHALL BE 1-1/4" NOT 1"
 AS SHOWN. SOME PIPE SIZES ARE NOT CLEAR AND LEGIBLE.
 MAKE SURE ALL PIPE SIZES ARE LEGIBLE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2008-11-24 Cont ID  
Sent By kstevens Date 2008-11-24 Time 10:12 Rev Time 0.00
Received By kstevens Date 2008-11-24 Time 10:12 Sent To  
Notes
2008-11-24 10:30:56DENIED
 REFERENCE:
 FBC-2004 FUEL GAS
 FBC-2004 CHAPTER 1
  
 A. SUBMIT THE FOLLOWING INFORMATION FOR PERMIT:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE. -- NOT ALL LENGTHS INDICATED. (SEE
 HIGHLIGHTED SECTIONS OF PIPE).
  
 2. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
  
 3. ALL INFORMATION/DRAWINGS/SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPON-
 SIBLE FOR THE DESIGN. SECTION 104.2.1. PLEASE SHOW
 PRINTED NAME AS WELL AS SIGNATURE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  