Plan Review Details - Permit 08110341
Plan Review Stops For Permit 08110341
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-11-24 Cont ID  
Sent By rmcdouga Date 2008-11-24 Time 09:19 Rev Time 0.00
Received By rmcdouga Date 2008-11-24 Time 09:19 Sent To  
Notes
2008-11-21 16:56:422004 FBC W/2007 REVISIONS
 ADDITION AND LEVEL 2 ALTERATION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE VALUE INDICATED FOR THE SCOPE OF WORK IS TOO
 LOW. THE VALUE IS TO INCLUDE THE COST OF MATERIALS,
 LABOR, OVERHEAD AND PROFIT AS WOULD BE CHARGED BY A
 CONTRACTOR. FBC 108.3* CITY AMENDMENTS. PLEASE ADJUST
 VALUE.
  
 4) SUBMIT ENERGY CALCULATIONS AS REQUIRED BY FBC
 13-600.
  
 5) R302.1 EXTERIOR WALLS. EXTERIOR WALLS SEPARATED BY
 LESS THAN 6 FEET SHALL HAVE NOT LESS THAN A ONE-HOUR
 FIRE-RESISTIVE RATING WITH EXPOSURE FROM BOTH SIDES.
 PROJECTIONS SHALL NOT EXTEND TO A POINT CLOSER THAN 4
 FEET FROM AN ADJACENT PROJECTION OR WALL. THE EXTERIOR
 WALL OF THE ADDITION IS LESS THAN 6 FEET FROM THE
 PROPERTY LINE, INDICATE THE DISTANCE TO STRUCTURES ON
 THE ADJACENT PROPERTY ON THE SITE PLAN OR SURVEY.
  
 6) ON SHEET 6 OF THE PLANS SPECIFY 8D RING SHANK NAILS
 FOR THE ROOF SHEATHING AT ALL REFERENCES. FBC
 R803.2.3.1 SEE RED MARKS ON PLAN.
  
 7) THE ATTIC ACCESS LOCATION DOES NOT WORK WITH THE
 TRUSS ORIENTATION. ON SHEET 6 THE ACCESS OPENING HAS
 BEEN CHANGED USING WHITE-OUT. THIS IS NOT ACCEPTABLE ON
 SIGNED AND SEALED PLANS. PLEASE CORRECT. FBC 106.1.1
 AND 106.1.3* CITY AMENDMENTS
  
 8) SPECIFY THE RAFTER SIZE, GRADE AND SPECIES FOR THE
 REAR COVERED PATIO. R301.1
  
 9) SPECIFY THE BEAM HANGERS THAT WILL BE USED TO
 CONNECT THE 2 X 10 WOOD BEAM AT THE REAR PATIO TO THE
 STRUCTURE. R301.1
  
 10) PROVIDE A STRUCTURAL DETAIL INDICATING HOW THE
 RAFTERS OVER THE FRONT ENTRY WILL BE SUPPORTED. SPECIFY
 THE RAFTER SIZE, GRADE AND SPECIES.
  
 11) ON SHEET 7 THE GARAGE DOOR DETAIL SPECIFIES A 130
 MPH WIND SPEED. THE WIND SPEED FOR WEST PALM BEACH IS
 140 MPH PER FIGURE 301.2(4).
  
 12) SPECIFY THE SPACING OF THE DOOR BUCK FASTENERS ON
 THE PLANS. R613.6
  
 13) PROVIDE WINDOW BUCK DETAILS. R613.6
  
 14) SPECIFY THE FLORIDA PRODUCT APPROVAL NUMBERS FOR
 THE TRUSS ANCHORS AND CONNECTORS ON THE PLANS OR SUBMIT
 TWO COPIES OF PRODUCT APPROVALS FOR EACH OF THEM. FAC
 RULE 9B-72.
  
 15) INDICATE HOW THE CONCRETE ROOF TILE SPECIFIED IN
 THE DETAIL ON SHEET 4 WILL BE ATTACHED. R905.3
  
 16) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 17) PRODUCT APPROVALS WERE SUBMITTED FOR ASPHALT
 SHINGLES AND THE PLANS SPECIFY CONCRETE SHINGLES.
 PLEASE CORRECT. FAC RULE 9B-72
  
 18) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE
 STRUCTURAL WINDOW MULLIONS. FAC RULE 9B-72
  
 19) UNDER DESIGN STATEMENT ON SHEET 1 OF THE PLANS
 NON-IMPACT WINDOWS AND STORM SHUTTERS ARE SPECIFIED.
 THE PRODUCT APPROVALS THAT WERE SUBMITTED ARE FOR
 IMPACT WINDOWS. PLEASE CORRECT.
  
 20) ONE COPY OF AN EVALUATION OF A THERMA TRU DOOR WAS
 SUBMITTED. PLEASE SUBMIT TWO COPIES OF THE PRODUCT
 EVALUATION ALONG WITH TWO COPIES OF A COVERSHEET WITH
 THE FLORIDA FL#.
  
 21) TWO COPIES OF A MIAMI-DADE NOA FOR A PVC LITE-KIT
 ASSEMBLY FOR USE WITH AN APPROVED IMPACT SINGLE GLAZED
 DOOR SYSTEM, HAVING A CURRENT NOA. PLEASE INDICATE
 WHERE THIS WILL BE INSTALLED AND PROVIDE TWO COPIES OF
 NOA FOR THE DOOR IT WILL BE USED WITH.
  
 22) THE ONE COPY OF PRODUCT APPROVALS FOR PERMIT #
 08050516 THAT WAS SUBMITTED IS NOT REQUIRED AND SHOULD
 NOT BE SUBMITTED WITH THIS PROJECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-12-01 Cont ID  
Sent By btrobaug Date 2008-12-01 Time 11:59 Rev Time 0.00
Received By btrobaug Date 2008-12-01 Time 10:41 Sent To M
Notes
2008-12-01 11:24:18 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, 2007
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
 PLEASE REMOVE ALL OLD OR VOIDED SHEETS AND REPLACE WITH
 CORRECTED ONES WHEN RESUBMITTING. INCLUDE THEM
 SEPARATELY TO EXPEDITE THE REVIEW PROCESS. RESPOND TO
 REVIEW COMMENTS IN WRITING.
 ALL COMMENTS RELATE TO SHEET 5 OF 8, UNLESS OTHERWISE
 NOTED.
  
 1} THERE IS AN ADDED AIR HANDLER LOCATED IN THE GARAGE,
 BUT NOT SHOWN IN THE LOAD CALCULATION. SUBMIT
 MANUFACTURERS SPECIFICATIONS FOR THAT SYSTEM. SHOW THE
 LOCATION OF THE A/C EQUIPMENT ON THE PLAN. ALSO SHOW
 COMPLIANCE WITH THE REQUIRED DISCONNECT PER 440.14,
 RECEPTACLE PER 210.63. SEE SEE 220.83 EXISTING DWELLING
 UNIT
 THIS SECTION SHALL BE PERMITTED TO BE USED TO DETERMINE
 IF THE EXISTING SERVICE OR FEEDER IS OF SUFFICIENT
 CAPACITY TO SERVE ADDITIONAL LOADS. WHERE THE DWELLING
 UNIT IS SERVED BY A 120/240-VOLT OR 208Y/120-VOLT,
 3-WIRE SERVICE, IT SHALL BE PERMISSIBLE TO CALCULATE
 THE TOTAL LOAD IN ACCORDANCE WITH 220.83(A) OR (B).
  
 2} KITCHEN RECEPTACLES MUST COMPLY WITH 210.8(A)(6)
 GFI.SEE THAT PER THE LEGEND THEY ARE NOT.
  
 NOTE: THE NEW DINING ROOM AND NEW BREAKFAST ROOM MUST
 COMPLY WITH 210.52(B)(1). EVEN THOUGH EXISTING THEY
 MUST BE CHANGED TO SMALL APPLIANCE CIRCUITS. LOCATE THE
 RECEPTACLES IN THE DINING ROOM PER 210.52 AND MAKE A
 NOTE ON THE PLAN INDICATING COMPLIANCE WITH
 210.52(B)(1) TO AVOID CONFUSION IN THE FIELD.
  
 3} THE BATH FAN IS NOT INCLUDED ON THE ELECTRICAL
 PLAN.106.1.1 FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-11-26 Cont ID  
Sent By adarroug Date 2008-11-26 Time 10:23 Rev Time 0.00
Received By adarroug Date 2008-11-26 Time 10:23 Sent To E
Notes
2008-11-26 10:23:21TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-12-07 Cont ID  
Sent By rregueir Date 2008-12-07 Time 12:36 Rev Time 0.00
Received By rregueir Date 2008-11-18 Time 09:40 Sent To PC
Notes
2008-11-18 09:40:57TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-12-07 Cont ID  
Sent By rregueir Date 2008-12-07 Time 12:35 Rev Time 0.00
Received By rregueir Date 2008-12-07 Time 11:40 Sent To PC
Notes
2008-12-07 12:35:22REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 NOTE: ALTHOUGH MECHANICAL PLAN CONTAINS A NOTE FOR
 MODIFIED PLANS TO BE SUBMITTED AT A LATER DATE, MINIMUM
 CODE COMPLIANCE MUST BE DEMONSTRATED ON PLANS AT THIS
 TIME, PRIOR TO PERMIT ISSUANCE.
  
 1. PROPOSED NEW MASTER BATHROOM SHOWN NO OPERABLE
 WINDOWS TO THE OUTDOORS OR EXHAUST FAN. SHOW HOW
 REQUIRED VENTILATION FOR THIS ROOOM IS TO BE PROVIDED
 IN ACCORDANCE WITH FBC R303.3 THROUGH R303.5.
  
 2. PLANS CALL FOR CLOTHES DRYER IN THE PROPOSED NEW
 GARAGE. SHOW MEANS AND LOCATION OF DRYER EXHAUST IN
 ACCORDANCE WITH FBCR M1501.1 THROUGH M1501.3.
  
 3. NO ENERGY CALCULATIONS WERE PROVIDED WITH THIS
 APPLICATION. PROVIDE A PROPERLY COMPLETED FORM 600
 ENERGY CODE COMPLIANCE FORM IN ACCORDANCE WITH FBCB
 13-101.2.2. ALSO, A COOLING AND HEATING LOAD
 CALCULATION SHALL BE PERFORMED ON THE BUILDING AND
 SHALL BE ATTACHED TO THE FORM 600 SUBMITTED WHEN
 APPLICATION IS MADE FOR A BUILDING PERMIT IN ACCORDANCE
 WITH FBCB 13-607.1.ABC.1.
  
 4. PROVIDE AN EQUIPMENT SCHEDULE TO CONFIRM EQUIPMENT
 BEING PROPOSED WILL BE IN COMPLIANCE WITH ENERGY CODE
 MINIMUM EFFICIENCIES AS SPECIFIED IN FORM 600 AND
 COOLING/HEATING LOAD CALCULATIONS AS STATED ABOVE.
  
 5. PROVIDE INSTALLATION DETAIL FOR ATTACHMENT OF
 OUTDOOR CONDENSING UNIT FOR WIND RESISTANCE IN
 ACCORDANCE WITH FBCR M1307.3.
  
 6. IT IS NOT CLEAR ON PLANS WHETHER ALL NEW PROPOSED
 HABITABLE AREAS HAVE SUFFICIENT WINDOW AND DOOR
 OPENINGS FOR ADEQUATE VENTILATION. PLEASE PROVIDE
 VENTILATIONS CALCULATIONS SHOWING TOTAL DOOR/WINDOW
 OPENABLE AREAS WITH RESPECT TO FLOOR AREA BEING
 VENTILATED IN ACCORDANCE WITH FBC R303.1 AND R303.2.
  
 7. NOTE 1.3 ON SHEET 5 CALLS FOR A 10X10 TRANSFER W/ 8"
 DUCT BETWEEN THE FLORIDA ROMM AND "ADJACENT ROOM." THE
 LOCATION OF THIS TRANSFER AND WHICH ADJACENT ROOM IS
 NOT SHOWN ON PLANS. PLEASE CLARIFY THE LOCATION AND
 INTENT OF THIS DUCT IN ACCORDANCE WITH FBCR M1602.4.
  
 8. THERE ARE DUCTS FROM THE PROPOSED NEW AHU WHICH ARE
 MISSING SIZES ON THE PLANS. PLEASE PROVIDE MISSING
 INFORMATION. AN AIR DISTRIBUTION SYSTEM SHALL BE
 DESIGNED AND INSTALLED TO SUPPLY THE REQUIRED
 DISTRIBUTION OF AIR IN ACCORDANCE WITH FBCR M1601.1 AND
 M1601.3.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-12-04 Cont ID  
Sent By kstevens Date 2008-12-04 Time 14:13 Rev Time 0.00
Received By kstevens Date 2008-12-04 Time 14:13 Sent To  
Notes
2008-12-04 14:25:09DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. 1 OF 8 DESIGN CRITERIA TO INDICATE 2007 REVISIONS TO
 THE FBC-2004.
  
 2. WHITE OUT IS NOT APPROVED ON SHEETS SUBMITTED FOR
 PUBLIC RECORD. (SHTS 2 0F 8 & 6 OF 8). SECTION 106.1.3.
  
 3. SHTS 2 OF 8 & 7 OF 8 (RISER DIAGRAM). THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL CONNECT TO BRANCH
 DRAIN OR DRAINAGE STACK A MINIMUM OF 3 INCHES IN
 DIAMETER. SECTION 406.3. PLEASE CORRECT ON THE FLOOR
 PLAN AND THE RISER DIAGRAM. 2" SHOWN ON THE FLOOR PLAN
 & RISER DIAGRAM.
  
 4. SHT 7 OF 8 SANITARY RISER DIAGRAM PLEASE SHOW THE
 AIR ADMITTENCE VALVE ON THE RISER DIAGRAM, AND THE
 DISHWASHER SHALL CONNECT UPSTREAM OF THE TRAP OF THE
 KITCHEN SINK. SECTIONS 106.1.1, 103.5.1.3(6) & 1002.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2008-11-25 Cont ID  
Sent By mcruz Date 2008-11-25 Time 11:57 Rev Time 0.00
Received By mcruz Date 2008-11-25 Time 11:37 Sent To I
Notes
2008-11-25 11:56:37PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK
 EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS
 "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 4. INDICATE IF ANY TREES WILL BE REMOVED AS A RESULT OF
 THE PROPOSED PROJECT. IF YES, A TREE ALTERATION/REMOVAL
 PERMIT WILL BE REQUIRED. CONTACT ROBERT KUSSNER, CITY
 LANDSCAPE PLANNER, AT (561) 822-1462 FOR THE
 APPLICATION.
  
 5. PLEASE CORRELATE ALL PLANS. THE SETBACK DIMENSIONS
 SHOWN ON THE SITE PLAN (SHEET 2 OF 8) DIFFER FROM BOTH
 THE FOUNDATION AND FLOOR PLAN.
  
 6. IF APPLICABLE, INDICATE SETBACK DIMENSIONS FROM
 PROPOSED OR RELOCATED A/C EQUIPMENT TO ALL PROPERTY
 LINES. PURSUANT THE ZLDR, SECTION 94-305(B)(4):
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET
 INTO A REQUIRED SETBACK.
  
 7. VERIFY THAT THE PROPOSED ADDITION DOES NOT INTEFERE
 WITH THE REQUIRED 75% OF REQUIRED LANDSCAPING IN THE
 FRONT YARD. PURSUANT TO THE CITY OF WEST PALM BEACH
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION
 94-482: REQUIRED OFF-STREET PARKING SPACES FOR LESS
 THAN FOUR RESIDENTIAL DWELLING UNITS SHALL BE LOCATED
 ON THE PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED.
 REQUIRED PARKING MAY BE LOCATED IN A FRONT YARD;
 HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75 PERCENT
 OF THE FRONT YARD AREA MUST BE LANDSCAPED. PARKING
 AREAS LOCATED IN THE FRONT YARD SHALL BE SURFACED WITH
 A SMOOTH, NONDUSTING SURFACE IN COMPLIANCE WITH
 SUBSECTION 33-485(E). IT SHALL BE A VIOLATION OF THIS
 CHAPTER TO PARK ON ANY UNPAVED AREAS AS DESCRIBED IN
 THIS ARTICLE.
  
 PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE
 FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT
 BUILDING FACADE).
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  