Plan Review Details - Permit 08110340
| Plan Review Stops For Permit 08110340 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2009-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-01-30 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-01-30 |
Time |
13:14 |
Sent To |
M |
|
| Notes |
| 2009-01-30 13:14:48 | MECHANICAL SCOPE SUBMITTED AND SHOWN ON ELECTRICAL | | | PLANS. ELECTRICAL WAS PREVIOUSLY REVIWED UNDER SEPARATE | | | PERMIT FOR RE-MODEL. THERE IS NO ELECTRICAL REVIEW DONE | | | ON THESE PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-11-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-19 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-19 |
Time |
09:46 |
Sent To |
M |
|
| Notes |
| 2008-11-19 09:48:05 | MECHANICAL SCOPE SUBMITTED AND SHOWN ON ELECTRICAL | | | PLANS. ELECTRICAL WAS PREVIOUSLY REVIWED UNDER SEPARATE | | | PERMIT FOR RE-MODEL. THERE IS NO ELECTRICAL REVIEW DONE | | | ON THESE PLANS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-10 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-10 |
Time |
10:39 |
Sent To |
M |
|
| Notes |
| 2009-03-10 10:39:35 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-28 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-28 |
Time |
15:42 |
Sent To |
E |
|
| Notes |
| 2009-01-28 15:42:38 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-25 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-18 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2008-11-18 11:05:39 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-03-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-17 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-17 |
Time |
08:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-03 |
Time |
19:03 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-03 |
Time |
19:03 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-24 |
Time |
20:13 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-24 |
Time |
19:53 |
Sent To |
PC |
|
| Notes |
| 2008-11-24 20:12:56 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | FBCR = FLORIDA BUILDING CODE, RESIDENTIAL | | | | | | 1. NO INFORMATION WAS PROVIDED SHOWING HOW THIS | | | APPLIANCE IS TO BE ATTACHED FOR WIND RESISTANCE. | | | MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE | | | EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO | | | RESIST THE WIND PRESSURES ON THE EQUIPMENT AND THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING PER FBCR M1307.3. PROVIDE | | | ENGINEERED DETAIL FOR CURB ATTACHMENT TO STRUCTURE AND | | | RTU ATTACHMENT TO CURB. | | | | | | 2. SHOW MEANS AND LOCATION OF CONDENSATE DISPOSAL. | | | CONDENSATE FROM ALL COOLING COILS OR EVAPORATORS SHALL | | | BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED | | | PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO | | | A STREET, ALLEY OR OTHER AREAS SO AS TO CAUSE A | | | NUISANCE IN ACCORDANCE WITH FBCR M1411.3. ALSO, | | | CONDENSATE LINES SHALL DISCHARGE AT LEAST 1 FOOT AWAY | | | FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND | | | PIPING, TAIL EXTENSIONS OR SPLASH BLOCKS IN ACCORDANCE | | | WITH FBCR R320.6. | | | | | | 3. PROVIDE AUXILIARY OR SECONDARY DRAIN PROTECTION IN | | | ACCORDANCE WITH FBCR M1411.3.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
|