Plan Review Details - Permit 08110326
Plan Review Stops For Permit 08110326
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-02-02 Cont ID  
Sent By rmcdouga Date 2009-02-02 Time 07:43 Rev Time 0.00
Received By rmcdouga Date 2009-02-02 Time 07:10 Sent To  
Notes
2009-02-02 08:44:42REVISED EXTERIOR WALLS FROM 2 X 4 TO 2 X 6.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-01-12 Cont ID  
Sent By rmcdouga Date 2009-01-12 Time 08:32 Rev Time 0.00
Received By rmcdouga Date 2009-01-12 Time 07:39 Sent To  
Notes
2009-01-12 08:31:50REVISION
  
 DENIED BY BUILDING
  
 1) SUBMIT 2 COMPLETE SETS OF REVISED PLANS. FBC 106.1*
 CITY AMENDMENTS
  
 2) PLEASE MAKE ALL OF THE CHANGES TO THE DRAWINGS
 INCLUDING THE HANDWRITTEN RED-LINE CORRECTIONS THAT
 WERE MADE TO THE PERMITTED SET. FBC 106.1.3
  
 3) PLEASE MAKE THE RED-LINED CORRECTIONS TO THE ENERGY
 CALCULATION FORM. ALSO, THE OWNER IS REQUIRED TO SIGN
 AND DATE THE ENERGY CALCULATIONS. FBC 13-600
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-18 Cont ID  
Sent By rmcdouga Date 2008-12-18 Time 13:13 Rev Time 0.00
Received By rmcdouga Date 2008-12-18 Time 13:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-11-20 Cont ID  
Sent By rmcdouga Date 2008-11-20 Time 15:55 Rev Time 0.00
Received By rmcdouga Date 2008-11-20 Time 15:55 Sent To  
Notes
2008-11-20 11:03:282004 FBC W/2007 AMENDMENTS
 ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) REVISE THE CODE REFERENCED TO THE 2004 FBC WITH 2007
 AMENDMENTS.
  
 4) THE ENERGY CALCULATION FORMS ARE INCORRECT. THE
 CLIMATE ZONE IS 8, THE CONDITIONED FLOOR AREA IS 336
 SQFT, THE EXTERIOR WALL TYPE IS WOOD FRAME WITH R-11
 INSULATION AND THE SLAB ON GRADE IS NOT INSULATED. FBC
 13-600
  
 5) SPECIFY THE SIZE OF THE EXTERIOR DOOR ON THE PLANS.
 FBC R301.2.1
  
 6) INDICATE THE THE NAME AND CONTACT INFORMATION FOR
 THE PERSON RESPONSIBLE FOR THE DESIGN ON THE PLANS. FBC
 106.1.3* CITY AMENDMENTS
  
 7) SPECIFY THE SIZE OF THE FOOTINGS ON THE PLANS. THE
 MINIMUM FOOTING SIZE FOR MONOLITHIC SLABS IS 20" THICK
 AND 12" WIDE PER IBHS GUIDELINES FOR HURRICANE
 RESISTANT CONSTRUCTION. FBC R301.2.1.1
  
 8) SHOW COMPLIANCE WITH R403.1.4 MINIMUM DEPTH. ALL
 EXTERIOR FOOTINGS SHALL BE PLACED AT LEAST 12 INCHES
 (305 MM) BELOW THE UNDISTURBED GROUND SURFACE.
  
 9) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED
 GRADE. CONCRETE AND MASONRY FOUNDATION WALLS SHALL
 EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE
 FOUNDATION AT ALL POINTS A MINIMUM OF 4 INCHES (102 MM)
 WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6 INCHES
 (152 MM) ELSEWHERE.
  
 10) SHOW COMPLIANCE WITH SECTION 704 INSPECTION FOR
 TERMITES IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM).
  
 11) SPECIFY THE SPACING FOR THE 2 X 4 WALL STUDS ON THE
 PLANS. TABLE R602.2(3)
  
 12) THE WALL TO FOUNDATION ANCHORAGE REQUIRES 5/8"
 DIAMETER ANCHOR BOLTS AT 18" O.C. PER IBHS GUIDELINES
 FOR HURRICANE RESISTANT CONSTRUCTION AND FBC
 R301.2.1.1. PLEASE REVISE PLANS.
  
 13) THE EXTERIOR WALL HEADER ABOVE THE TWO 25 SH
 WINDOWS IS REQUIRED TO BE TWO 2 X 8 ON EDGE PER
 R602.2.8. REVISE WALL SECTION.
  
 14) THE PRODUCT APPROVALS FOR THE HARDI PLANK SIDING
 REQUIRES 5/8" PLYWOOD SHEATHING AND A WATERPROOFING PER
 FBC 2121.6.2.1 BEHIND IT. PLEASE REVISE WALL SECTION.
 ALSO SEE FBC R 703.2 FOR WATERPROOFING REQUIREMENTS OF
 15# FELT OR OTHER APPROVED WATERPROOFING.
  
 15) R803.2.3.1 SHEATHING FASTENINGS. WOOD STRUCTURAL
 PANEL SHEATHING SHALL BE FASTENED TO ROOF FRAMING WITH
 8D RING-SHANK NAILS AT 6 INCHES ON CENTER AT EDGES AND
 6 INCHES ON CENTER AT INTERMEDIATE FRAMING. PLEASE
 CLARIFY THE ROOF SHEATHING FASTENING NOTES ON THE WALL
 SECTION.
  
 16) ROOF UNDERLAYMENT IS REQUIRED TO BE FASTENED AT 6"
 ON CENTER AT THE EDGES AND TWO (2) ROWS AT 12" O.C. IN
 THE FIELD PER RAS 117. PLEASE REVISE NOTES ON THE WALL
 SECTION.
  
 17) R905.2.2 SLOPE. ASPHALT SHINGLES SHALL ONLY BE USED
 ON ROOF SLOPES OF TWO UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (2:12) OR GREATER. FOR ROOF SLOPES FROM TWO
 UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) UP TO FOUR
 UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO
 LAYERS OF UNDERLAYMENT COMPLYING WITH ASTM D 226 TYPE I
 OR TYPE II, ASTM D 4869 TYPE I OR TYPE II OR ASTM D
 6757 IS REQUIRED IN ACCORDANCE WITH SECTION R905.2.7.
 SPECIFY TWO LAYERS OF UNDERLAYMENT ON THE PLANS.
 R905.2.7
  
 18) THE PLANS SPECIFY SIMPSON H10 CONNECTORS AT THE
 EXTERIOR WALL OF THE EXISTING STRUCTURE WHERE THE NEW
 RAFTERS ARE ATTACHED TO THE EXISTING ONES. AN H10-2
 WILL BE REQUIRED AT THIS LOCATION WHERE THE RAFTERS ARE
 DOUBLED. PLEASE REVISE. R301.1
  
 19) TWO COPIES OF THE PRODUCT APPROVALS ARE REQUIRED.
 ONLY ONE COPY WAS SUBMITTED. FBC 106.1* CITY AMENDMENTS
  
 20) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE
 STRUCTURAL WINDOW MULLIONS THAT WILL BE USED TO ATTACH
 THE TWO SINGLE HUNG WINDOWS. FAC RULE 9B-72
  
 21) GENERAL NOTE #4 ON THE ENCLOSED PATIO PLAN
 SPECIFIES IMPACT RATED WINDOWS. THE PRODUCT APPROVAL
 THAT WAS SUBMITTED IS FOR NON-IMPACT RATED WINDOWS AND
 REQUIRE STORM PANELS. PLEASE SUBMIT PRODUCT APPROVALS
 FOR STORM PANELS OR FOR IMPACT RATED WINDOWS.
 R301.2.1.2
  
 22) THE VALUE FOR THE ADDITION SPECIFIED ON THE PLANS
 IS TOO LOW. IT HAS BEEN INCREASED TO $12,673.00 BASED
 ON MARSHALL AND SWIFT BUILDING VALUATION DATA.
 ADDITIONAL PERMIT FEES ARE OWED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-01-30 Cont ID  
Sent By btrobaug Date 2009-01-30 Time 10:14 Rev Time 0.00
Received By btrobaug Date 2009-01-30 Time 08:27 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2009-01-08 Cont ID  
Sent By btrobaug Date 2009-01-08 Time 10:10 Rev Time 0.00
Received By btrobaug Date 2009-01-08 Time 09:58 Sent To B
Notes
2009-01-08 10:09:27 
  
  
 REVISION DENIED
  
 1} HAND DRAWN CHANGES TO THE PLAN ARE NOT ACCEPTABLE
 FOR RECORD RETENTION OR CLARITY IN THE FIELD. 106.1.3
 FBC AS AMENDED.
  
 2} THE ELECTRICAL PLAN SHEET MUST BE REVISED.THE
 REVISION SUBMITTED WAS HAND DRAWN ON THE "NEW ENCLOSED
 PATIO PLAN-SITE LAYOUT. THIS DOES NOT REVISE THE
 ELECTRICAL SHEET THAT WAS REVIEWED FOR THE PERMIT.
 106.1.3 FBC
  
 3} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER
 106.1.
  
 4} TWO SETS OF PLANS ARE REQUIRED FOR REVIEW. ONE SET
 SUBMITTED WAS THE PERMIT SET, 2 REVISED SETS ARE
 REQUIRED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-12-01 Cont ID  
Sent By btrobaug Date 2008-12-01 Time 15:27 Rev Time 0.00
Received By btrobaug Date 2008-12-01 Time 15:12 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-01-28 Cont ID  
Sent By adarroug Date 2009-01-28 Time 10:46 Rev Time 0.00
Received By adarroug Date 2009-01-28 Time 10:46 Sent To E
Notes
2009-01-28 10:46:39TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-12-30 Cont ID  
Sent By adarroug Date 2008-12-30 Time 11:34 Rev Time 0.00
Received By adarroug Date 2008-12-30 Time 11:34 Sent To Z
Notes
2008-12-30 11:34:31TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-12 Cont ID  
Sent By adarroug Date 2008-12-12 Time 09:18 Rev Time 0.00
Received By adarroug Date 2008-12-12 Time 09:18 Sent To B
Notes
2008-12-12 09:19:21TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-12-08 Cont ID  
Sent By adarroug Date 2008-12-08 Time 15:24 Rev Time 0.00
Received By adarroug Date 2008-11-18 Time 10:24 Sent To  
Notes
2008-11-18 10:24:22TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-12-18 Cont ID  
Sent By rmcdouga Date 2008-12-18 Time 11:41 Rev Time 0.00
Received By rmcdouga Date 2008-12-18 Time 11:41 Sent To  
Notes
2008-12-18 11:41:36NO MECHANICAL PLANS WERE SUBMITTED.

Review Stop Z ZONING
Rev No 2 Status N Date 2008-12-31 Cont ID  
Sent By mcruz Date 2008-12-31 Time 10:48 Rev Time 0.00
Received By mcruz Date 2008-12-31 Time 10:47 Sent To E
Notes
2008-12-31 10:48:55*ZONING REVIEW NOT REQUIRED: WORK ONLY AND THE VALUE OF
 PROPOSED WORK DOES NOT EXCEED 50% OF THE IMPROVEMENT
 VALUE.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2008-12-08 Cont ID  
Sent By mcruz Date 2008-12-08 Time 11:06 Rev Time 0.00
Received By mcruz Date 2008-12-08 Time 11:06 Sent To I
Notes
2008-12-08 11:07:48SIDE SETBACK SHALL BE AT LEAST 7 FEET 6 INCHES FROM
 EAST PROPERTY LINE AS NOTED ON PLAN.