Plan Review Details - Permit 08110304
| Plan Review Stops For Permit 08110304 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2009-10-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-10-19 |
Time |
11:06 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-10-19 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2009-10-19 11:07:19 | REVISION: DRIVING RANGE NETTING CALCULATIONS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-07 |
Time |
16:21 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2009-08-07 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2009-08-07 16:30:00 | BUILDING PLAN REVIEW | | | PERMIT: 08110304 | | | ADD: 7001 PARKER AVE. | | | CONT:THE WEITZ CO. | | | TEL: (407)461-0392 KRIS LENGIEZA | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW SUBMITTED AUGUST 07/2009 | | | ACTION: DENIED | | | | | | 1) THE RANGE NETTING DESIGN CALCULATIONS INDICATE AN | | | EXPOSURE "B" CALCULATION PLEASE SEE ATTACHED DIAGRAM OF | | | OVER 3,000 FEET OF EXPOSURE "C" TERRAIN. PLEASE | | | RECALCULATE WITH THE CORRECTED FACTOR. | | | | | | 2) THE 2ND ISSUE SHEET 1OF 6 INDICATES 6.5.15 OTHER | | | STRUCTURES 60' POLE, BURIED 8'-0". WHERE AS SHEET 4 THE | | | FOUNDATION CALCULATIONS INDICATES A BURIAL DEPTH OF | | | 10'-0". PLEASE CORRECT DEPTH OF FOUNDATION WHICH MAY | | | CHANGE WITH NEW EXPOSURE "C" CALCULATIONS. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-24 |
Time |
14:29 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2009-04-24 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-13 |
Time |
11:54 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2009-04-13 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2009-04-13 12:10:19 | BUILDING PLAN REVIEW | | | PERMIT: 08110304 | | | ADD: 7001 PARKER AVE. | | | CONT: WEITZ GOLF INTERNATIONAL LLC | | | TEL: (561)799-7800 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW AS PERMIT APPLICATION | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) PLANS SUBMITTED FOR PERMIT APPLICATION (FIRST TIME | | | REVIEW) AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE | | | 2007 FBC BUILDING WITH THE 2009 SUPPLEMENTS. | | | | | | 1C) PLANS SUBMITTED TO THE CITY FOR REVIEW ARE NOT | | | SIGNED NOR SEALED , | | | 2) SHEETS PS1 & PS2 INDICATE THE INSTALLATION OF A | | | FIBERGLASS COMPOSITE PUMP STATION: | | | | | | 2A) MISSING INFORMATION,110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR RECORD KEEPING & | | | FOR CERTIFICATE OF OCCUPANCY: | | | 2A)(1) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT | | | IS DESIGNED. | | | 2A)(2)) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | 2A)(3)) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER | | | 6, TABLE 601. | | | | | | 2B) SHEET PS2, NOTE 5.2.1.A SHELTERS NEEDING TO BE | | | RATED FOR 140MPH, 3 SECOND GUST NEED PLANS TO BE SIGNED | | | AND SEALED BY A FLORIDA P.E. | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | FL ADMIN CODE 61G16.003 ARCHITECTS | | | | | | 2C) DESCREPANCY IN PLANS PS1 IT APPEARS THERE IS A | | | I-BEAM FLOOR SYSTEM WHERE AS PS 2 DETAIL INDICATES | | | FLOOR SLAB SYSTEM, NOR IS THERE STRUCTURAL INFORMATION | | | ON THE PIT OR WELL WALL AND FLOOR SYSTEMS. PS2 OPTIONS | | | INDICATE FLOOR SYSTEM FIBERGLASS, WOOD, ALUMINUM OR | | | STEEL. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED/ 1609.6.2.1. | | | | | | 2D) WIND DESIGN INFORMATION MISSING: | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | | | | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | | | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | | | | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE FOR THE | | | SELECTION OF EXTERIOR COMPONENTS AND CLADDING MATERIALS | | | NOT SPECIFICALLY DESIGNED BY THE REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 3) COMPLIED. | | | | | | 4) SHEET 37, RAIN SHELTERS: | | | | | | 4A) COMPLIED. | | | | | | 4B) COMPLIED. | | | | | | 4C)COMPLIED. | | | | | | 4D) COMPLIED. | | | | | | 4E) SECOND REQUEST, THE RAIN SHELTER ROOF PURLINS ARE | | | INDICATED TO 1X4 AT 2'-0" O.C., PLEASE IDENTIFY THE | | | TYPE OF METAL ROOFING TO BE USED. PLANS INDICATE A | | | METAL STANDING SEAM SYSTEM, IS THIS A STRUCTURAL | | | ROOFING SYSTEM NOT REQUIRING SHEATHIN BUT STRUCTURAL | | | 2X4 PURLINS 2308.10.5 OR WILL IT BE A ARCHITECURAL | | | SYSTEM REQUIRING A SOLID OR CLOSELY FITTED DECK | | | (1507.4.1). | | | | | | 4F) SECOND REQUEST THE WATER FOUNTAIN SHELTER USES 1X4 | | | PURLINS AT 1'-0" O.C., PLEASE IDENTIFY THE TYPE OF | | | METAL ROOFING TO BE USED. PLANS INDICATE A METAL | | | STANDING SEAM SYSTEM, IS THIS A STRUCTURAL ROOFING | | | SYSTEM NOT REQUIRING SHEATHIN BUT STRUCTURAL 2X4 | | | PURLINS 2308.10.5 OR WILL IT BE A ARCHITECURAL SYSTEM | | | REQUIRING A SOLID OR CLOSELY FITTED DECK (1507.4.1). | | | | | | 4G) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | | REPORTS ARE AS FOLLOWS: | | | | | | 4G)(1) TRUSS ANCHORS, CLIPS | | | | | | 4G)(2) ROOF COVERINGS: STANDING METAL SEAM | | | | | | 4H) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4I) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-11-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-11-21 |
Time |
08:49 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2008-11-21 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2008-11-24 09:52:45 | BUILDING PLAN REVIEW | | | PERMIT: 08110304 | | | ADD: 7001 PARKER AVE. | | | CONT: MAJOR WORKING DRAWING/ VINCENT NOEL | | | TEL: (561)622-7288 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 1C) PLANS SUBMITTED TO THE CITY FOR REVIEW ARE NOT | | | SIGNED NOR SEALED , | | | 2) SHEETS PS1 & PS2 INDICATE THE INSTALLATION OF A | | | FIBERGLASS COMPOSITE PUMP STATION: | | | | | | 2A) MISSING INFORMATION,110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR RECORD KEEPING & | | | FOR CERTIFICATE OF OCCUPANCY: | | | 2A)(1) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT | | | IS DESIGNED. | | | 2A)(2)) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | 2A)(3)) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER | | | 6, TABLE 601. | | | | | | 2B) SHEET PS2, NOTE 5.2.1.A SHELTERS NEEDING TO BE | | | RATED FOR 140MPH, 3 SECOND GUST NEED PLANS TO BE SIGNED | | | AND SEALED BY A FLORIDA P.E. | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | FL ADMIN CODE 61G16.003 ARCHITECTS | | | | | | 2C) DESCREPANCY IN PLANS PS1 IT APPEARS THERE IS A | | | I-BEAM FLOOR SYSTEM WHERE AS PS 2 DETAIL INDICATES | | | FLOOR SLAB SYSTEM, NOR IS THERE STRUCTURAL INFORMATION | | | ON THE PIT OR WELL WALL AND FLOOR SYSTEMS. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED/ 1609.6.2.1. | | | | | | 2D) WIND DESIGN INFORMATION MISSING: | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | | | | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | | | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | | | | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE FOR THE | | | SELECTION OF EXTERIOR COMPONENTS AND CLADDING MATERIALS | | | NOT SPECIFICALLY DESIGNED BY THE REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 3) SHEET OV & L2 INDICATE THE PUMP STATION OPERATES IN | | | A HIGHLY CORROSIVE ENVIROMENT, WHAT CAUSES THE HIGHLY | | | CORROSIVE ENVIROMENT, IS THERE CORROSIVE CHEMICALS TO | | | BE STORED THERE OR INTRODUCED INTO THE IRRIGATION | | | SYSTEM WITHIN THIS STRUCTURE? 106.1.2 ADDITIONAL | | | INFORMATION REQUIRED, PLEASE SEE SECTION 307.6 FOR H-4 | | | TYPE OCCUPANCY AND TABLE 307.7(1). | | | | | | 4) SHEET 37, RAIN SHELTERS: | | | | | | 4A) MISSING INFORMATION,110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR RECORD KEEPING & | | | FOR CERTIFICATE OF OCCUPANCY: | | | 4A)(1) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT | | | IS DESIGNED. | | | 4A)(2)) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | 4A)(3)) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER | | | 6, TABLE 601. | | | | | | 4B) 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | | | | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | | | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | | | | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES | | | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR | | | THE SELECTION OF EXTERIOR COMPONENTS AND CLADDING | | | MATERIALS NOT SPECIFICALLY DESIGNED BY THE REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 4C) PLANS CALL FOR 2X8 RAFTERS, PLEASE SUPPLY THE | | | SPECIES OF WOOD, GRADE, DEFLECTION AND SPANS 2308.10.3. | | | | | | 4D) PLANS ALSO CALL FOR A 2X8 RIDGE, PLEASE SEE | | | 2308.10.4 THE RIDGE SHALL BE NOT LESS IN DEPTH THAN THE | | | CUT END OF THE RAFTER, NORMALLY ONE SIZE LARGER (2X10). | | | | | | 4E) THE RAIN SHELTER ROOF PURLINS ARE INDICATED TO 1X4 | | | AT 2'-0" O.C., PLEASE IDENTIFY THE TYPE OF METAL | | | ROOFING TO BE USED. PLANS INDICATE A METAL STANDING | | | SEAM SYSTEM, IS THIS A STRUCTURAL ROOFING SYSTEM NOT | | | REQUIRING SHEATHIN BUT STRUCTURAL 2X4 PURLINS 2308.10.5 | | | OR WILL IT BE A ARCHITECURAL SYSTEM REQUIRING A SOLID | | | OR CLOSELY FITTED DECK (1507.4.1). | | | | | | 4F) THE WATER FOUNTAIN SHELTER USES 1X4 PURLINS AT | | | 1'-0" O.C., PLEASE IDENTIFY THE TYPE OF METAL ROOFING | | | TO BE USED. PLANS INDICATE A METAL STANDING SEAM | | | SYSTEM, IS THIS A STRUCTURAL ROOFING SYSTEM NOT | | | REQUIRING SHEATHIN BUT STRUCTURAL 2X4 PURLINS 2308.10.5 | | | OR WILL IT BE A ARCHITECURAL SYSTEM REQUIRING A SOLID | | | OR CLOSELY FITTED DECK (1507.4.1). | | | | | | 4G) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | | REPORTS ARE AS FOLLOWS: | | | | | | 4G)(1) TRUSS ANCHORS, CLIPS | | | | | | 4G)(2) ROOF COVERINGS | | | | | | 4H) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4I) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2009-04-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-16 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-16 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2009-04-16 08:17:41 | ** NOTED** | | | | | | | | | | | | 1) NOTE: SEPARATE PERMIT AND PLANS REQUIRED FOR | | | ELECTRICAL SYSTEM CONTROLS, SEPARATE FEEDS AND | | | CONNECTIONS TO IRRIGATION PUMPS ETC | | | NO ELECTRICAL PER NEC 2005, NO PERMIT APPLIED FOR. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-20 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-20 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2008-11-20 10:54:17 | | | | | | | | | | ** FAILED REVIEW ** | | | | | | | | | | | | 1) NOTE: PLANS ONLY SUBMITTED FOR * PLAN REVIEW * ONLY. | | | PLEASE KNOW ONCE PLANS ARE FOUND TO BE CODE COMPLIANCE | | | FOR ISSUANCE THE REVIEW WILL STILL REMAIN IN A FAILED | | | STATUS UNTIL PERMIT APPLICATION BY A LICENSED | | | CONTRACTOR HAS BEEN SUBMITTED. REVIEW OF CURRENT | | | LICENSING OF CONTRACTOR(S), DESIGNER(S) AND FIRM WILL | | | BE DONE AT THIS TIME. | | | PLEASE ALSO KNOW THAT IN ORDER TO LOCK IN REVIEW AND | | | DESIGN UNDER CURRENT ADOPTED CODE(S) PERMIT APPLICATION | | | MUST BE MADE. THERE IS NO SCHEDULE OF CODE CHANGE UNTIL | | | MARCH 1ST, 2009. | | | ** IF THERE ARE ANY QUESTIONS ON THIS PROCESS PLEASE | | | CONTACT THIS OFFICE/REVIEWER/. | | | | | | 2) NOTE: ALL PLANS ARE REQUIRED UNDER FLORIDA | | | ADMINISTRATIVE CODE TO CONTAIN THE TITLE BLOCKS FOR | | | ARCHITECT, ARCHITECTURAL FIRMS, AND ENGINEERING FIRMS | | | ETC. THESE TITLE BLOCKS ARE REQUIRED TO INCLUDE | | | INFORMATION AND ADDRESS OF PROJECT. | | | THEY ARE REQUIRED TO CONTAIN ALL LICENSING INFORMATION | | | FOR THE FIRMS, PRINTED LICENSE NUMBER, ADDRESS, AND | | | PHONE NUMBER ETC. | | | PLEASE SEE FAC 61G1-16.004 FOR ARCHITECT, ARCHITECTURAL | | | FIRMS. | | | PLEASE SEE FAC 61G15-23.002 FOR ENGINEERS AND | | | ENGINEERING FIRMS. | | | | | | | | | ** PLEASE KNOW THAT A CERTIFICATE OF AUTHORIZATION | | | LICENSE NUMBER IS REQUIRED FOR ALL ARCHITECTURAL FIRMS | | | INCLUDING LANDSCAPING ARCHITECTURAL FIRMS PER FLORIDA | | | STATUTES 481.219. | | | | | | ** PLEASE KNOW THAT A CERTIFICATE OF AUTHORIZATION | | | LICENSE NUMBER IS REQUIRED FOR ALL ENGINEERING FIRMS | | | PER FS 471.023 | | | | | | ** THESE COMMENTS ARE FOR ALL TRADES AND ALL SHEETS | | | WHETHER OR NOT COMMENTS ARE MADE BY OTHER TRADE | | | REVIEWS. THESE ARE NOT NEW REQUIREMENTS IN FACT THEY | | | HAVE BEEN AROUND SINCE LATE NINETEEN SEVENTIES. | | | IF THERE ARE ANY QUESTIONS ON REQUIREMENTS PLEASE | | | CONTACT THIS OFFICE/REVIEW OR DEPARTMENT OF BUSINESS | | | AND PROFESSIONAL REGULATION FOR THE STATE OF FLORIDA. | | | | | | 3) NOTE: SOME SHEETS IN SETS ARE NOT SIGNED, DATED OR | | | SEALED BY ANY DESIGN PROFESSIONAL. PLEASE KNOW ALL | | | PLANS SHALL CONTAIN PERSON RESPONSIBLE FOR DESIGN EVEN | | | WHEN MEETING EXCEPTIONS TO FS 481.229 AND 471.003. | | | THIS PROJECT DOES NOT MEET EXCEPTIONS AND THEREFORE | | | MUST BE COMPLETED BY THE LICENSE DESIGNER OF RECORD. | | | 481.221,471.025. | | | | | | 4) NOTE: PLEASE SUBMIT ELECTRICAL PLANS AND DETAILS FOR | | | ELECTRICAL SCOPE OF WORK FOR SHELTERS ETC. | | | PLEASE SHOW CONDUCTORS, OVER CURRENT PROTECTION, | | | CIRCUITING ETC. | | | PLEASE BE SURE TO SEE 2005 NEC, 2004 FBC FOR MINIMUM | | | DESIGN FOR COMPLIANCE. | | | IF THERE ARE ANY QUESTIONS ON THIS PLEASE CALL. | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2009-04-24 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
dlauderm |
Date |
2009-04-24 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2009-04-24 09:46:19 | WENT OVER CHANGES WITH ARCHITECT AT MEETING ON 04/23/09 | | | AND REVIEWED THE CHANGES. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2009-04-14 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2009-04-14 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
dlauderm |
Date |
2009-04-14 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2009-04-14 15:09:24 | ANY QUESTIONS CONTACT: | | | DEAN S. LAUDERMILK, PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1083 (ENG. SERVICES) | | | 561-805-6716 (CONSTRUCTION SERVICES) | | | SHEET 7 OF 40: | | | 1. KEY COLORING ON THIS SHEET DOES NOT MATCH 6 OF 40. | | | CHANGE COLORING TO REDUCE CONFUSION. | | | 2. RAIN SHELTER IS NOT LOCATED AS SHOWN. IT IS | | | APPROXIMATELY 87' NORTH AND 157' WEST OF CART PATH. | | | SHEET 9 OF 40: | | | 1. SINCE YOU HAVE SHOWN THE PROPERTY LINE ON THIS SET | | | OF DRAWINGS THE WORK SEEMS TO BE EXTENDING OFF THE | | | PROPERTY. CHECK WITH THE PROJECT MANAGER V. NOEL | | | (561-494-1096) FOR THE PROPER PROPERTY LINE. IF IT IS | | | AS SHOWN THEN REDUCE THE "PERIMETER ZONE" WORK TO A | | | POINT IT IS INSIDE CITY PROPERTY. | | | SHEET 12, 14, 16, AND 18 OF 40: | | | 1. SEE NOTE ON 21 OF 40, THE OUTCOME OF HOW THE PUMP | | | STATION IS DESIGNED WILL CHANGE THIS NOTE. | | | 2. THE NOTE STATES: "TO BE DISCONNECTED, OWNER TO | | | DISPOSE OF PUMPS." THE DEMOLITION SHEET (5 OF 40) DOES | | | NOT STATE THAT THE PUMP HOUSE, CONTROL PANEL, ELECTRIC | | | LINES, OR CONCRETE PAD FOR THE EXISTING PUMPS ARE TO BE | | | REMOVED. ARE THEY TO BE REMOVED, CAPPED OFF? | | | SHEET 21 OF 40: | | | 1. I DO NOT HAVE THE PREVIOUS PLAN TO COMPARE TO THIS | | | PLAN, BUT THIS PLAN SHOWS THE FINISHED FLOOR ELEVATION | | | AS 15'-9". THE PLAN THEN GOES ON TO STATE THAT THE PUMP | | | SET EXTENDS DOWN FROM THIS ELEVATION 11', WHICH PLACES | | | IT AT ELEVATION 4'-9". THE ELEVATION ON THE INVERT OF | | | THE INTAKE PIPE IS 1'-0". WHICH MEANS THAT THE BOTTOM | | | OF THE WET WELL IS 2'-9" HIGHER THAN THE INTAKE PIPE. | | | IT APPEARS THAT THE BOTTOM OF THE WETWELL SHOULD BE | | | AROUND MINUS 2'-0" AND THAT THE PUMP SET SHOULD BOTTOM | | | OUT AT AROUND MINUS 1'-0" OR 17' LONG. THIS WOULD MAKE | | | THE WETWELL APPROXIMATELY 18' DEEP, WHICH WOULD AFFECT | | | THE NOTES ON SHEETS 12,14, 16, AND 18 OF 40. | | | 2. INFORMATIONAL NOTE: SHEETS 12, 14, 16, AND 18 OF 40 | | | ALL HAVE A NOTE THAT STATE THE WETWELL SHALL BE "60" | | | CONCRETE". HUGGER BANDS WILL NOT WORK WITH PVC PIPE, | | | WHICH IS THE MATERIAL THAT HAS BEEN SUBMITTED WITH THIS | | | SET OF PLANS (J-M PIPE, 24" CLASS 235 PSI, DR18, OR | | | CLASS 165 PSI DR26), NEITHER CLASS WAS CHOSEN, BUT BOTH | | | ARE PVC AND REQUIRE A DIFFERENT TYPE OF ADAPTER THAN | | | THE "HUGGER BAND" THAT IS SHOWN ON THE PLAN. THE | | | PREVIOUS REVIEWER WAS INTERESTED TO SEE WHAT MATERIAL | | | WAS TO BE USED (IT DOES NOT STATE ON THIS SHEET, WHICH | | | IT SHOULD). IT DOES GIVE A LIST OF PIPE MATERIALS THAT | | | CAN BE USED ON SHEETS 12, 14, 16, AND 18 OF 40. THE | | | MATERIALS DO NOT NEED TO BE SUBMITTED AT THIS TIME, TO | | | CONSTRUCTION SERVICES, BUT LATER TO THE PROJECT MANAGER | | | AT ENGINEERING SERVICES. TOWARDS THAT END ONE OF THE | | | FOLLOWING ADAPTERS WILL BE REQUIRED TO ADAPT TO THE | | | WETWELL FOR PVC; | | | PVC MANHOLE TO PIPE ADAPTERS: | | | USED TO SEAL THE PIPE TO THE MANHOLE. ALL ADAPTERS WILL | | | BE MADE TO FIT PVC, SDR-26 PIPE. ADAPTERS FOR USE WITH | | | ALL NEW CONSTRUCTION. PVC ADAPTERS SHALL HAVE DOUBLE | | | GASKETED BELL, WITH SANDCOATING CAST INTO THE OUTSIDE | | | TO ALLOW FOR ADHERENCE TO THE CONCRETE SEAL. | | | HARCO - THE HARRINGTON CORP., P.O. BOX 10335, | | | LYNCHBURG, VA 24306 | | | FLOW CONTROL | | | OTHER MANHOLE TO PIPE ADAPTERS: | | | USED TO SEAL THE PIPE TO THE MANHOLE. ALL ADAPTERS WILL | | | BE MADE TO FIT PVC, SDR-26 PIPE. ADAPTERS FOR USE WITH | | | ALL NEW CONSTRUCTION. ADAPTERS SHALL HAVE STAINLESS | | | STEEL RING SEALS TO SEAL THE ADAPTER TO THE PIPE AND TO | | | THE MANHOLE IF THEY ARE NOT POURED IN PLACE. | | | PRESS SEAL GASKET CORPORATION | | | PRESS-BOOT | | | U.S. PRECAST MANHOLE W/HDPE LINER CAST-IN BOOT TO | | | SLEEVE CONNECTION | | | U.S. PRECAST HDPE LINER SYSTEM "TURN BACK" JOINT | | | INSTALLED AFTER CAST | | | 3. I AM NOT A STRUCTURAL ENGINEER, BUT I WOULD THINK | | | THAT THERE NEEDS TO BE SOME STEEL IN THE CONCRETE SLAB, | | | AND THE SLAB NEEDS TO BE ON TOP OF THE WETWELL. | | | 4. SHEET 12 OF 40 HAS A NOTE THAT STATES: "WATER LEVEL | | | NOVEMBER 18TH 1974 ELEV. 8.60', LOWEST ANTICIPATED | | | WATER ELEV. 2.85'. SO WHY IS THERE A COMMENT THAT THE | | | ELEVATION OF THE WATER (8.60') IS UNCONFIRMED ON THIS | | | SHEET? | | | 5. SINCE THE WATER TABLE IS APPROXIMATELY 8.60' AND THE | | | WETWELL IS AS DEEP AS IT MAY END UP, A NOTE NEEDS TO BE | | | ADDED STATING THAT THE WETWELL NEEDS TO BE DESIGNED BY | | | A PE AND CERTIFIED THAT IT WILL NOT FLOAT. | | | 34 OF 40: | | | 1. ADD TO ALL DETAILS THE USE OF FILTER FABRIC AROUND | | | THE TOPS, SIDES AND BOTTOMS OF ALL OF THE GRAVEL. | | | 2. CHANGE THE NOTES "1/4 TO 3/4" WASHED GRAVEL TO 3/4" | | | WASHED ROCK. | | | 35 OF 40: | | | 1. ADD TO DETAIL THE USE OF FILTER FABRIC AROUND THE | | | TOPS, SIDES AND BOTTOMS OF ALL OF THE GRAVEL. | | | 2. CHANGE THE NOTES "1/4 TO 3/4" WASHED GRAVEL TO 3/4" | | | WASHED ROCK. | | | 3. WHERE ARE THE CHANNEL DRAINS GOING TO BE PLACED THAT | | | ARE SHOWN IN THIS DETAIL? STATE THERE SPECIFIC | | | LOCATION. | | | 4. WATER FOUNTAIN SHELTER UTILITY PLAN IS CONFUSING. | | | ADD TO THE END OF THE TITLE "(SEE SHEET F2, 28 OF 40)". | | | 5. I DO NOT KNOW HOW BUT CHANGE THE NOTE CONCERNING | | | ABANDONING THE ELECTRIC AND WATER LINES, IT APPEARS YOU | | | WANT TO CUT THEM OFF FROM THE BATHROOM. I WOULD THINK | | | THAT YOU WOULD NEED THE WATER LINE FOR THE WATER | | | FOUNTAIN. | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2008-12-09 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2008-12-09 |
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
2008-12-05 |
Time |
|
Sent To |
ENG |
|
| Notes |
| 2008-12-09 10:11:58 | ENGINEERING REVIEW - FAILED - 12-09-08 | | | | | | #1 PLAN D2 (PAGE 18 OF 37) SHOWN INCONSISTENCIES WITH | | | THE PS1 (SHEET 21 OF 37) | | | SIZE OF INTAKE SCREENS, SCREEN PATTERNS, | | | #2 INTAKE PIPE MATERIAL NEEDS TO BE SPECIFIC. | | | #3 INCONSISTENCIES IN THE FFE AND GRADE. | | | #4 SHOW ALL ELEVATIONS. PS1 | | | #5 PLEASE USE CONSISTENCY WHEN LABELING DIMENSIONS | | | (EITHER DECIMAL OR FT. IN. PICK ONE) | | | #6 PLAN VIEW OF THE INTAKE AREA IS NEEDED. | | | STABILIZATION OF THE BANK IS REQUIRED. IT MUST PROVIDE | | | ENOUGH COVERAGE TO INCLUDE RESTABILIZATION OF THE BANK | | | BASED ON THE ANGLE OF REPOSE DISTURBED | | | WHEN LAYING THE PIPE. | | | #7 ELEVATIONS ARE NOT CONSISTENT FROM D2 TO PS1, VERIFY | | | #8 PROVIDE SURVEY AND OR PROPERTY LINE SO AS TO | | | IDENTIFY WHERE PUMP STATION WILL BE LOCATED. | | | #9 PERMIT FROM SFWMD MAY APPLY. WATER USE CALCULATIONS | | | WILL BE INCREASED? VERIFY | | | #10 WHERE WILL 12"X8" REDUCER OFFSET PIPE SEGMENT ON | | | SHEET PS1 WILL BE USED? CALL MATERIAL | | | #11 SEE PLAN FOR NOTES AND REDLINES FOR OTHER MISC | | | ITEMS. | | | #12 SUBMIT A SWPPP (STORMWATER POLLUTION PREVENTION | | | PLAN MUST BE USED. SPECIFICALLY WORKING AROUND THE NEW | | | PUMP STATION AREA. | | | ALSO IDENTIFY WHAT WORK WILL OCCUR AT THE PREVIOUS | | | PUMPING LOCATION. CONTRACTOR WILL NEED THIS TO MAINTAIN | | | HIS SWPPP | | | HTTP://CFPUB.EPA.GOV/NPDES/STORMWATER/SWPPP.CFM | | | #13 SHOW PROJECT INTERACTION WITH FDOT ROW (ANY | | | DRAINAGE CONCERNS?) | | | | | | MANUEL J GONZALEZ, PROJECT COORDINATOR | | | LOCATION ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | 1000 - 45TH STREET, SUITE 15 | | | WEST PALM BEACH FL 33407 | | | MAILING ADDRESS: | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | P.O. BOX 3506 | | | WEST PALM BEACH FL 33401 | | | TELEPHONE: | | | 45TH STREET OFFICE : 561-494-1040 | | | 45TH DIRECT: 561-494-1085 | | | FAX: 561-494-1117 | | | CITY HALL OFFICE: (561) 805-6723 | | | CITY HALL DIRECT: (561) 805-6327 | | | CITY HALL FAX: (561) 805-6731 OR 805-6676 | | | NEXTEL: 561-644-7301 | | | NEXTEL DIRECT CONNECT: 159*28165*38 | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-04-24 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-04-24 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2009-04-24 10:15:34 | *****APPROVED W/PROVISO***** | | | | | | PLAN SHEET G-2 STAMPED, INITIALED, AND DATED WITH | | | FOLLOWING PROVISO. | | | | | | | | | PROVISO: | | | | | | ROADS WHICH MAY BE USED FOR FIRE DEPARTMENT ACCESS | | | SHALL BE DESIGNED AND MAINTAINED TO SUPPORT THE IMPOSED | | | LOADS OF FIRE APPARATUS AND SHALL BE PROVIDED WITH AN | | | ALL-WEATHER DRIVING SURFACE. THESE ROADS SHALL HAVE | | | ADEQUATE VERTICAL CLEARANCES AND WIDTH TO ACCOMMODATE | | | FIRE APPARATUS. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-10-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2009-10-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2009-10-07 17:12:52 | TO JW DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-05 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-05 |
Time |
09:17 |
Sent To |
B |
|
| Notes |
| 2009-08-05 09:17:56 | TO JW'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-04-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-09 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-09 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2009-04-09 09:55:54 | TO "C32" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-12-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-18 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2008-11-18 08:50:46 | TO "COMM" BD#43--EXPEDITED-- |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-04-24 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-04-24 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2009-04-24 15:05:43 | ***LANDSCAPE REVIEW PASSED WITH 'PROVISO'*** | | | | | | 1. ALL LANDSCAPE COMMENTS MADE ON 4/23/09 SHALL BE | | | ADDRESSED WITH THE PLANS REVISED AND APPROVED PRIOR TO | | | FINAL INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-04-23 |
Time |
13:05 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2009-04-23 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2009-04-23 13:41:05 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1 PURSUANT TO SECTION 94-445 (4)(G)(3), AUTOMATIC | | | IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED | | | LANDSCAPED AREAS FOR ALL PROPERTIES. | | | | | | 2. PURSUANT TO SECTION 94-448 (F)(11), TREES WHICH ARE | | | INCLUDED AS PROHIBITED TREES PURSUANT TO SUBSECTION | | | 94-445(4)(I), SHALL BE REMOVED AND DISPOSED OF FROM THE | | | ENTIRE SITE BEFORE A CERTIFICATE OF OCCUPANCY CAN BE | | | OBTAINED. THIS WOULD INCLUDE ALL REAS MENTIONED IN ITEM | | | #1. | | | | | | 3 SUBMIT A TREE ALTERATION PERMIT APPLICATION WITH TWO | | | (2) SETS OF PLANS TO THE PLANNING AND ZONING | | | DEPARTMENT. ALL TREES TO REMAIN IN PLACE OR BE | | | RELOCATED SHALL BE CLEARLY IDENTIFIED ON THE LANDSCAPE | | | PLAN AND DISPLAYED IN TABULAR FORM. THE QUANTITIES | | | SHALL BE SHOWN. THE NEW LOCATION OF TREES BEING | | | RELOCATED SHALL BE SHOWN AND ALL TREES DESIGNATED TO BE | | | RELOCATED ---SHALL BE RELOCATED. A NOTE MAKING THIS | | | PROCESS OPTIONAL SHALL BE REMOVED FROM THE PLAN. | | | | | | 4. PURSUANT TO SECTION 94-443 (D)(2)(E)(1), AT LEAST 30 | | | PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR OF ALL | | | COMMERCIAL STRUCTURES SHALL BE PLANTED WITH TREES, | | | SHRUBS OR HEDGES. THIS APPLIES TO ALL PROPOSED | | | STRUCTURES. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462, |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-24 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-04-24 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2009-04-24 14:27:47 | PASSED BY THTE BUILDING OFFICIAL DOUG WISE WITH | | | SIGNATURE ON COVERSHEET. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-11-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-20 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-20 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2008-11-21 07:16:13 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2004 CHAPTER 1 | | | | | | 1. ALL SHEETS DESIGNED BY THE LANDSCAPE ARCHITECT SHALL | | | HAVE A TITLE BLOCK AND SHOW THE INFORMATION REQUIRED BY | | | FAC 61G1-16.004(1)(2)(3)(4)(5)(6). FS 481.219, | | | 481.2055. ALSO THE DATE THE SIGNATURE AND SEAL ARE | | | AFFIXED TO THE PLANS SHALL BE INDICATED ON THE PLANS ON | | | OR NEAR THE SEAL. | | | | | | 2. IRRIGATION SHEETS 12, 14, 16 OR 18 SHALL INDICATE | | | THE LOCATION OF THE RAIN SENSOR/WEATHER STATION | | | W/TELEPHONE LINK. SECTION 106.1.1 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-04-24 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-04-24 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2009-04-24 14:16:37 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 08110304 | | | ADDRESS: 7001 PARKER AVENUE | | | CONTRACTOR/CONTACT: WEITZ GOLF INTERNATIONAL LLC - | | | BRYAN BERNARDO | | | TELEPHONE NO.: 561.799.7800 | | | SCOPE OF REVIEW: REGRADING/REGRASSING, NEW IRRIGATION, | | | PUMP STATION, NEW SHELTERS, NEW LANDSCAPING. | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | | | | PRIOR TO FINAL INSPECTION DETAILS SHALL BE PROVIDED | | | REGARDING THE INSTALLATION OF THE ADDITIONAL NETTING. | | | ARE THE POLES EXISTING? PLEASE INDICATE THE OVERALL | | | HEIGHT, ETC. AND HOW THIS WILL BE INSTALLED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | PHONE: (561) 822-1435 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-04-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2009-04-23 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2009-04-23 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2009-04-23 11:46:21 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 08110304 | | | ADDRESS: 7001 PARKER AVENUE | | | CONTRACTOR/CONTACT: WEITZ GOLF INTERNATIONAL LLC - | | | BRYAN BERNARDO | | | TELEPHONE NO.: 561.799.7800 | | | SCOPE OF REVIEW: REGRADING/REGRASSING, NEW IRRIGATION, | | | PUMP STATION, NEW SHELTERS, NEW LANDSCAPING. | | | | | | REVIEW STATUS: FAILED | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1) PLEASE PROVIDE DETAILS REGARDING THE INSTALLATION OF | | | THE ADDITIONAL NETTING. ARE THE POLES EXISTING? PLEASE | | | INDICATE THE OVERALL HEIGHT, ETC. AND HOW THIS WILL BE | | | INSTALLED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | PHONE: (561) 822-1435 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-11-26 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-11-26 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-11-26 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2008-11-26 12:12:06 | ZONING PLAN REVIEW | | | PERMIT: 08110304 | | | ADD: 7001 PARKER AVE. | | | CONT: MAJOR WORKING DRAWING/ VINCENT NOEL | | | TEL: (561) 622-7288 | | | | | | REVIEW STATUS: FAILED | | | | | | 1) A CLASS B SPECIAL USE PERMIT SHALL BE APPROVED BY | | | THE ZONING BOARD OF APPEALS PRIOR TO THE ISSUANCE OF | | | ANY PERMITS. PLEASE CONTACT ME REGARDING APPLICATION | | | MATERIALS, PROCESS, ETC. | | | | | | 2) THE PROPERTY SHALL BE REPLATTED. | | | | | | 3) PLEASE CLARIFY WHY A PORTION OF THE PROPERTY IS | | | UNDER PRIVATE OWNERSHIP. PLEASE REFER TO PCN: | | | 74-43-44-09-06-000-0790, WHICH IS OWNED BY TIM EDWARDS | | | SERVICES, INC. | | | | | | 4) THE SMALL SINGLE PARCEL ON THE SOUTH SIDE OF MADDOCK | | | STREET, WEST OF GEORGIA AVENUE SHOULD BE REZONED TO | | | RECREATION OPEN SPACE (ROS) SO AS TO CREATE A | | | CONSISTENT ZONING/LAND USE ACROSS ALL OF THE GOLF | | | COURSE/PARK PROPERTY. | | | | | | 5) PLEASE PROVIDE DETAILS REGARDING THE INSTALLATION OF | | | THE ADDITIONAL NETTING. ARE THE POLES EXISTING? PLEASE | | | INDICATE THE OVERALL HEIGHT, ETC. AND HOW THIS WILL BE | | | INSTALLED. | | | | | | 6) PLEASE INDICATE THE PROPERTY LINES ON ALL PLANS AND | | | PROVIDE THE DIMENSIONS FROM THE PROPERTY LINES TO ALL | | | OF THE PROPOSED STRUCTURES/SHELTERS. | | | | | | 7) PLEASE PROVIDE THE OVERALL HEIGHT DIMENSIONS ON ALL | | | STRUCTURE DETAILS. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | PHONE: (561) 822-1435 | | | EMAIL: [email protected] |
|
|
|