| Plan Review Stops For Permit 08110217 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-03-06 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-03-06 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-02-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-02-10 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-02-10 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2009-02-10 11:37:19 | BUILDING PLAN REVIEW | | | PERMIT: 08110217 | | | ADD: 6907 OKEECHOBEE BLVD | | | CONT: PLAN REVIEW | | | TEL: (727)815-3336 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2/10/09 | | | REVIEW; 3RD | | | ACTION: DENIED | | | | | | 1) OK | | | 2) NOTED | | | 2) OK | | | 3) OK | | | | | | **THIRD REQUEST** | | | 4) UNTIL A LICENSE CONTRACTOR IS SIGNED ON THE | | | APPLICATION AND A PERMIT IS APPLIED FOR THE PLANS WILL | | | HAVE A FAIL STATUS. EVEN IF THE PLANS ARE FOUND TO BE | | | CODE COMPLIANT, THE FAIL STATUS WILL REMAIN UNTIL A | | | LICENSE CONTRACTOR IS SIGNED ON AND A PERMIT IS APPLIED | | | FOR. NOTE: THE 2007 FBC WILL GO INTO EFFECT MARCH 1ST. | | | IF A PERMIT IS APPLIED FOR AFTER THAT DATE THE PLANS | | | WILL BE REVIEWED TO THOSE CODES. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | PHONE (561)805-6726 | | | FAX (561) 805-6676 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-01-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-01-05 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-01-05 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2009-01-05 12:18:42 | BUILDING PLAN REVIEW | | | PERMIT: 08110217 | | | ADD: 6907 OKEECHOBEE BLVD | | | CONT: PLAN REVIEW | | | TEL: (727)815-3336 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1-05-09 | | | REVIEW; 2ND | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 2) OK | | | 3) OK | | | | | | **SECOND REQUEST** | | | 4) UNTIL A LICENSE CONTRACTOR IS SIGNED ON THE | | | APPLICATION AND A PERMIT IS APPLIED FOR THE PLANS WILL | | | HAVE A FAIL STATUS. EVEN IF THE PLANS ARE FOUND TO BE | | | CODE COMPLIANT, THE FAIL STATUS WILL REMAIN UNTIL A | | | LICENSE CONTRACTOR IS SIGNED ON AND A PERMIT IS APPLIED | | | FOR. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-11-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-11-20 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-11-20 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2008-11-20 08:32:47 | BUILDING PLAN REVIEW | | | PERMIT: 08110217 | | | ADD: 6907 OKEECHOBEE BLVD | | | CONT: PLAN REVIEW | | | TEL: (727)815-3336 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 11-20-08 | | | REVIEW; 1ST | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION IS | | | REQUIRED ON THE PLANS. | | | | | | 3) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | | THIS CODE. | | | | | | 4) UNTIL A LICENSE CONTRACTOR IS SIGNED ON THE | | | APPLICATION THE PLANS WILL HAVE A FAIL STATUS. EVEN IF | | | THE PLANS ARE FOUND TO BE CODE COMPLIANT, THE FAIL | | | STATUS WILL REMAIN UNTIL A LICENSE CONTRACTOR IS SIGNED | | | ON THE APPLICATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | PHONE (561)805-6726 | | | FAX (561) 805-6676 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-06 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-06 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2009-03-06 08:27:24 | REDLINED 2006 NFPA-101/ LS CODE |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-02-09 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-02-09 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2009-02-09 14:29:41 | ** DENIED ** | | | | | | 1) NOTE: REVIEW TO REMAIN IN FAILED STATUS AS PERMIT | | | HAS NOT BEEN APPLIED FOR WITH A LICENSED CONTRACTOR FOR | | | SCOPE OF WORK WITH REQUIRED FEES. REVIEW OF ALL | | | LICENSING, CODES, AND PERMIT APPLIED FEE WILL BE DONE | | | WHEN PERMIT HAS BEEN APPLIED FOR. | | | PLEASE KEEP IN MIND ALL PERMIT APPLICATIONS MUST BE IN | | | BY MARCH 1ST OR COMPLETE DESIGN WILL BE REQUIRED TO BE | | | DONE UNDER THE NEW CODES. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-29 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-29 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2008-12-29 16:03:57 | ** DENIED REVIEW ** | | | | | | SOME NOTES FORM PREVIOUS REVIEW ARE STILL IN NEED OF | | | ADDRESSING. | | | | | | 1) NOTE: PLEASE SEE NOTE FROM PREVIOUS REVIEW IN WHICH | | | THERE WAS A NOTE ** IMPORTANT**. THIS WAS NOTED SO THAT | | | ALL OLD/VOIDED SHEETS WERE TO BE REMOVED FROM SETS AND | | | FOR ALL NEW REVISED SHEETS TO BE INSERTED INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. THIS WAS NOT DONE IN FACT | | | THE NEW SHEET WERE JUST PLACED ON TOP OF THE OLD SETS. | | | PLEASE BE SURE THIS ID DONE IN A NEAT AND ORDERLY | | | FASHION WITH REVISED PLANS. | | | | | | 2) NOTE: PERMIT APPLICATION HAS NOT BEEN MADE AT THIS | | | TIME. PLEASE KNOW THE FLORIDA BUILDING CODE WILL BE | | | CHANGING ON MATCH 1ST, 2009. | | | ONLY ONCE PERMIT APPLICATION IS MADE BY LICENSED | | | CONTRACTOR AND ALL CODE COMPLIANCE COMMENTS ARE | | | ADDRESSED WILL THE REVIEW GO INTO A PASSED STATUS. | | | THERE ARE MANY ASPECTS OF THE REVIEW WHICH ENTAIL | | | REVIEW OF ALL LICENSING INCLUDING THAT OF DESIGNERS AT | | | THE TIME OF APPLICATION, REVIEW AND PERMITTING. | | | | | | 3) NOTE: PLEASE PROVIDE LIGHTING CONTROLS PER FBC | | | 13-415.1.ABC.1.1, .1.2, .1.3. | | | THE RESPONSE LETTER MENTIONS THE STORE CONTAINS AN | | | ENERGY MANAGEMENT SYSTEM HOWEVER THE PLANS STILL | | | INDICATE ONLY STANDARD SINGLE POLE SWITCHES. THESE DO | | | NOT MEET THE CODE SECTIONS FOR SEPARATE SPACES. | | | PLEASE REVISE PLANS ACCORDINGLY. | | | SEPARATE SPACES WITH FLOOR TO CEILING PARTITIONS MAY BE | | | CONTROLLED FROM SYSTEM HOWEVER AUTOMATIC OVER RIDES | | | WOULD BE REQUIRED OR MEET AUTOMATED CONTROLS FOR THESE | | | AREAS SEPARATELY FROM THE SYSTEM. | | | | | | 4) NOTE: PLEASE SPECIFY WHICH METHOD OF CALCULATION IS | | | BEING USED. PLEASE SEE TABLES B AND C. BUILDING AREA | | | METHOD IN TABLE *C* DOES NOT CONTAIN THE SAME | | | ALLOWANCES AS SPACE BY SPACE. | | | 13-415.2,13-415.2.ABC.1.1,.1.2, 13-415.2.B, 13-415.2.C. | | | | | | 5) NOTE: PLEASE COMPLETE TITLE BLOCK FOR ELECTRICAL | | | ENGINEERING FIRM AS LISTED ON COVER SHEET. PLEASE SEE | | | FAC 61G15-23.002 FOR MISSING INFORMATION SUCH AS THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. THIS IS ALSO | | | REQUIRED PER FS 471.023. | | | | | | | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-11-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-19 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-19 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2008-11-19 08:42:07 | | | | ** FAILED REVIEW ** | | | | | | ** | | | | | | | | | 1) NOTE: PLANS SUBMITTED FOR * PLAN REVIEW * ONLY. ONCE | | | PLANS ARE FOUND TO BE CODE COMPLIANT AND REVIEW WILL | | | STILL REMAIN IN FAILED STATUS UNTIL PERMIT APPLICATION | | | HAS BEEN MADE BY A LICENSED CONTRACTOR. VERIFICATION OF | | | LICENSING, CODES ETC AT THE TIME OF PERMIT APPLICATION | | | WILL BE VERIFIED AT THAT TIME. | | | | | | 2) NOTE: CODES SHOULD REFERENCE LATEST ADOPTED | | | STANDARDS WHICH ARE 2004 FBC W/ 2007 REVISIONS. PLANS | | | INDICATE 2007, HOWEVER THE 2007 REVISIONS TO THE 2004 | | | FBC WERE ADOPTED MORE THAN A YEAR AGO. PLEASE ADJUST | | | NOTES/CODES. | | | | | | 3) NOTE: LIGHTING CONTROLS FOR NEW BEING INSTALLED ARE | | | REQUIRED TO MEET 13-415.1.ABC.1.1, .1.2. | | | THIS IS ONLY FOR NEW BEING INSTALLED WHICH DOES REQUIRE | | | AUTOMATED LIGHTING CONTROLS OF SOME TYPE. | | | | | | 4) NOTE: PLEASE SUBMIT AND SHOW LIGHTING PERFORMANCE | | | CALCULATIONS PER 13-415.2,13-415.2.B, | | | 13-415.2.ABC.1.1,.1.2. | | | | | | 5) NOTE: PLEASE SUBMIT AND SHOW THE UPDATE PANEL | | | SCHEDULE FOR NEW LP1 PANEL. AS RECORD SETS OF PLANS | | | NEED TO SHOW ALL PERMITTED WORK AND BE UPDATED FOR NEW | | | CIRCUITS ETC THESE NEED TO BE SUBMITTED AND SHOWN. | | | PLEASE BE SURE TO UPDATE LOADS ON ALL PANELS EVEN AS | | | MINOR AS THE LOAD MAY BE. THE RECORD DOCUMENTS ARE | | | REQUIRED TO COORDINATE WITH THE SCOPE OF WORK. | | | 408.4, 310.16, 240.4, 220 ETC | | | FBC 106.1.1, 106.5 | | | | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-03-06 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-03-06 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2009-03-06 12:31:37 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A1.1, A1.2, FP1.1, AND E1.1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2009-02-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-02-12 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-02-12 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2009-02-12 15:32:01 | ***DENIED*** | | | | | | PLANS SUBMITTED FOR PLAN REVIEW ONLY. PLANS APPEAR TO | | | BE CODE COMPLIANT BUT WILL REMAIN IN FAILED STATUS | | | UNTIL SUBMITTED AND REVIEWED FOR PERMIT APPLICATION. | | | | | | PLEASE NOTE THE FOLLOWING: | | | | | | LIFE SAFETY SHALL COMPLY WITH NFPA 101, 2006. THIS | | | CURRENT CODE WAS ADOPTED ON DECEMBER 31, 2008 AND WILL | | | APPLY TO THIS PROJECT AT THE TIME OF FIRE PLAN REVIEW | | | FOR PERMIT. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2009-01-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-01-07 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-01-07 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2009-01-07 11:00:19 | ***DENIED*** | | | | | | PLANS SUBMITTED FOR PLAN REVIEW ONLY. PLANS APPEAR TO | | | BE CODE COMPLIANT BUT WILL REMAIN IN FAILED STATUS | | | UNTIL SUBMITTED AND REVIEWED FOR PERMIT APPLICATION. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-24 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-24 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2008-11-24 11:19:55 | ***DENIED*** | | | | | | PLANS SUBMITTED FOR PLAN REVIEW ONLY. PLANS APPEAR TO | | | BE CODE COMPLIANT BUT WILL REMAIN IN FAILED STATUS | | | UNTIL SUBMITTED AND REVIEWED FOR PERMIT APPLICATION. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-03 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-03 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2009-03-04 13:14:28 | TO "BOB"#2 | | 2009-03-03 09:15:55 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-03 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-03 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2009-02-03 15:40:07 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-26 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-26 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2008-12-26 09:40:14 | TO "BOB"#12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-11-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-25 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-13 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2008-11-13 11:11:14 | TO "BOB"#7 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-06 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-06 |
Time |
08:49 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2009-02-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-15 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-15 |
Time |
09:48 |
Sent To |
PC |
|
| Notes |
| 2009-02-15 09:49:05 | **PLAN CHECK ONLY** | | | | | | PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE AND | | | PASSED. HWEVER, THE REVIEW WILL REMIAN IN FAIL STATUS | | | PENDING ACTUAL APPLICATION FOR PERMIT. | | | NOTE: THE NEW 2007 FBC IS IN EFFECT ON MARCH 1, 2009. | | | ANY APPLICATION FOR PERMIT SUBMITTED ON OR AFTER THAT | | | DATE WILL REQUIRE PLANS TO BE REVIEWED FOR COMPLIANCE | | | WITH THE NEW CODE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-01-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-01-10 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-01-10 |
Time |
17:03 |
Sent To |
PC |
|
| Notes |
| 2009-01-10 17:06:17 | REVIEW WILL REMAIN IN FAIL STATUS PENDING SUBMISSION OF | | | A PERMIT APPLICATION. | | | NOTE: THE 2007 FBC WILL BE IN EFFECT MARCH 1, 2009. A | | | PERMIT APPLICATION SUBMITTED ON OR AFTER THAT DATE WILL | | | REQUIRE REVIEW FOR COMPLIANCE WITH THE NEW CODE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-11-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-22 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-22 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2008-11-22 17:19:15 | **PLAN CHECK ONLY** | | | | | | PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE AND | | | PASSED. HWEVER, THE REVIEW WILL REMIAN IN FAIL STATUS | | | PENDING ACTUAL APPLICATION FOR PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-06 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-06 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2009-03-06 13:39:10 | OK PER KEN STEVENS. REVIEW WAS FAILED AS PERMIT HAD NOT | | | BEEN APPLIED FOR BY A LICENSED CONTRACTOR. SPOKE TO KEN | | | STEVENS AND HE WAS OK WITH REVIEW BEING CHANGED INTO A | | | PASSED STATUS. | | | PLANS WERE ALREADY STAMPED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-09 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-09 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2009-01-09 13:43:58 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | | | | 1. UNTIL A LICENSED CONTRACTOR IS SIGNED ON AN | | | APPLICATION FOR PERMIT THE STATUS WILL BE FAILED. PLANS | | | ARE CODE COMPLIANT AT THIS TIME. | | | | | | I M P O R T A N T - I N F O R M A T I O N | | | | | | B E L O W | | | | | | (NEW SHEETS SHALL BE INSERTED AND OLD SHEETS REMOVED. | | | PLANS SHALL BE SUBMITTED MINIMUM 2 SETS OF BOUND | | | PLANS). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-11-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-25 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-25 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2008-11-25 10:20:58 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | *****PLAN REVIEW ONLY***** | | | | | | 1. SHT A0.1 CODE REFERENCE SHALL ALSO INDICATE 2007 | | | AMENDMENTS/REVISIONS/SUPLIMENTS TO THE 2004 FBC. | | | | | | 2. PLEASE INDICATE THE LEVEL OF ALTERATION PER SECTION | | | 301.5 OF THE EXISTING BUILDING CODE. | | | | | | 3. SHT A1.0 DEMO KEYED NOTES #3. PLEASE IDENTIFY THE | | | FIXTURES. IF THERE ARE PLUMBING FIXTURES, THEN DEAD | | | ENDS ARE PROHIBITED PER SECTION 704.5. SECTION 106.1.2 | | | MORE INFORMATION REQUIRED. | | | | | | 4. SHT P1.1 THE SIGNATURE OF THE ENGINEER IS REQUIRED | | | WHEN SEALING THE PLANS. IT APPEARS THAT INITIALS WERE | | | USED IN PLACE OF THE SIGNATURE. IF INDEED THIS IS THE | | | LEGAL SIGNATURE OF THE ENGINEER, THEN A SIGNED, SEALED, | | | NOTORIZED LETTER INDICATING THE LEGAL SIGNATURE OF THE | | | ENGINEER SHALL BE SUBMITTED TO THIS OFFICE FOR OUR | | | FILE. FAC 61G15-23.002(1)(2) & FS 471.025. | | | | | | 5. SHT P1.1 ELECTRIC WATER HEATER DETAIL. THE RELIEF | | | VALVE (T & P) SHALL HAVE A VISIBLE AIR GAP OR AIR GAP | | | FITTING LOCATED IN THE SAME ROOM AS THE WATER HEATER. | | | SECTION 504.6.1. PLEASE SHOW ON THE DETAIL. | | | | | | 6. SHT P1.1 PLUMBING DRAWING NOTES #2.3 AIR CHAMBERS | | | ARE NOT APPROVED. PLEASE DELETE FROM NOTES. SECTION | | | 604.9 & PDI-WH 201. WATER HAMMER ARRESTORS ARE REQUIRED | | | FOR QUICK CLOSING VALVES ONLY. (ICE MACHINES, DISH | | | WASHERS & AUTOMATIC CLOTHES WASHERS). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|