Plan Review Details - Permit 08110101
Plan Review Stops For Permit 08110101
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-12-04 Cont ID  
Sent By rmcdouga Date 2008-12-04 Time 08:48 Rev Time 0.00
Received By rmcdouga Date 2008-12-04 Time 08:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date 2008-11-08 Cont ID  
Sent By amorse Date 2008-11-08 Time 09:24 Rev Time 1.00
Received By amorse Date 2008-11-08 Time 09:24 Sent To PC
Notes
2008-11-08 09:31:26 
  
 DENIED
  
 1) THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE
 BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS
 DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN
 GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600
 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C
 CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND
 PRESSURES ACCORDINGLY. THE ENGINEERING WIND LOAD SHEET
 IS FOR EXP. B
  
 2) ENGINEERED SHOP DRAWINGS SPECIFY 1/4 " TEMPERED
 GLASS, THIS IS NOT A TESTED AND APPROVED GLAZING TYPE
 IN THE PRODUCT APPROVAL DOCUMENTS BUT YOU DO HAVE THE
 TYPE 2 GLAZING (5/16" HEAT STRENGTHENED) SPECIFIED IN
 THE CONTRACT. PLEASE CLARIFY.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-12-01 Cont ID  
Sent By adarroug Date 2008-12-01 Time 16:20 Rev Time 0.00
Received By adarroug Date 2008-12-01 Time 16:20 Sent To B
Notes
2008-12-01 16:20:40TO "LMARTINEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-11-08 Time   Rev Time 0.00
Received By adarroug Date 2008-11-07 Time 08:15 Sent To  
Notes
2008-11-07 08:15:43TO "MISC" BOX#1

Review Stop Z ZONING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***