Plan Review Details - Permit 08110059
Plan Review Stops For Permit 08110059
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-02-19 Cont ID  
Sent By shill Date 2009-02-19 Time 15:20 Rev Time 0.00
Received By shill Date 2009-02-19 Time 15:20 Sent To ENG
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-01-21 Cont ID  
Sent By shill Date 2009-01-21 Time 16:16 Rev Time 0.00
Received By shill Date 2009-01-21 Time 15:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-11-19 Cont ID  
Sent By shill Date 2008-11-19 Time 15:09 Rev Time 0.00
Received By shill Date 2008-11-19 Time 15:09 Sent To  
Notes
2008-11-19 15:15:13****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. IN FRONT OF PETSMART, AN ACCESS AISLE IS SHOWN BUT
 THE ADJACENT SPACES ARE NOT LABELED AS ACCESSIBLE. ALSO
 THE PLAN STATES THERE ARE 28 ACCESSIBLE SPACES, BUT
 ONLY 26 ARE SHOWN.
  
 2. SHOW ALL ACCESSIBLE ENTRANCES. IT APPEARS THAT THERE
 ARE LIKELY ACCESSIBLE ENTRANCES AT THE BACK OF THE
 BUILDING (EXITS ARE ALSO ENTRANCES). SEE FBC11-4.6.2,
 IN BUILDINGS WITH MULTIPLE ACCESSIBLE ENTRANCES WITH
 ADJACENT PARKING, ACCESSIBLE PARKING SPACES SHALL BE
 DISPERSED AND LOCATED CLOSEST TO THE ACCESSIBLE
 ENTRANCES.
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2009-02-27 Cont ID  
Sent By mgonzale Date 2009-02-27 Time 10:53 Rev Time 1.00
Received By mgonzale Date 2009-02-27 Time 10:52 Sent To ENG
Notes
2009-02-27 10:53:33*** PASSED ***
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2008-11-18 Cont ID  
Sent By mgonzale Date 2008-11-18 Time 15:09 Rev Time 1.00
Received By mgonzale Date 2008-11-18 Time 15:08 Sent To ENG
Notes
2008-11-18 15:08:33-APPROVED WITH PROVISO-
 ACCESSIBILITY FROM ALL PUBLIC LOCATIONS MUST BE IN GOOD
 CONDITION.
 ONCE CONSTRUCTION IS READY TO BEGIN CONTACT THE PARTY
 BELOW TO ASSESS
 CURRENT ACCESSABILITY CONDITIONS, SIDEWALKS, ETC:
  
 MANUEL J GONZALEZ, PROJECT COORDINATOR (561) 494-1085
 LOCATION ADDRESS:
 CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 1000 - 45TH STREET, SUITE 15
 WEST PALM BEACH FL 33407
 MAILING ADDRESS:
 CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 P.O. BOX 3506
 WEST PALM BEACH FL 33401
 TELEPHONE:
 45TH STREET OFFICE : 561-494-1040
 45TH DIRECT: 561-494-1085
 FAX: 561-494-1117
 CITY HALL OFFICE: (561) 805-6723
 CITY HALL DIRECT: (561) 805-6327
 CITY HALL FAX: (561) 805-6731 OR 805-6676
 NEXTEL: 561-644-7301
 NEXTEL DIRECT CONNECT: 159*28165*38
 EMERGENCIES:
 CENTRAL OPERATIONS CENTER (DISPATCH) 561-822-2210
 E-MAIL:
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-02-10 Cont ID  
Sent By adarroug Date 2009-02-10 Time 09:55 Rev Time 0.00
Received By adarroug Date 2009-02-10 Time 09:55 Sent To Z
Notes
2009-02-10 09:56:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-01-05 Cont ID  
Sent By adarroug Date 2009-01-05 Time 10:16 Rev Time 0.00
Received By adarroug Date 2009-01-05 Time 10:16 Sent To Z
Notes
2009-01-05 10:16:27TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-11-17 Cont ID  
Sent By adarroug Date 2008-11-17 Time 16:16 Rev Time 0.00
Received By adarroug Date 2008-11-17 Time 16:16 Sent To ENG
Notes
2008-11-17 16:17:37TO "ENG" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-11-19 Cont ID  
Sent By shill Date 2008-11-19 Time 15:15 Rev Time 0.00
Received By shill Date 2008-11-05 Time 08:13 Sent To  
Notes
2008-11-05 08:21:48TO "Z" BOX

Review Stop Z ZONING
Rev No 3 Status P Date 2009-02-12 Cont ID  
Sent By lfranco Date 2009-02-12 Time 19:23 Rev Time 0.00
Received By lfranco Date 2009-02-12 Time 19:22 Sent To B
Notes
2009-02-12 19:30:56PLANNING AND ZONING: **** PASSED WITH PROVISO SEE BELOW
 ****
  
 1. RESPOND TO COMMENTS IN WRITING.
  
  
 2. SHEET A-7 SHOWS PROPOSED VIEW #8 WITH THE PARKING
 STALL DEPTH INCREASING. AS A RESULT, THE EXISTING
 TERMINAL ISLANDS ARE LESS THAN THE ADJACENT PARKING
 STALL (PURSUANT TO SECTION 94-443(C)(3)A), THEREFORE,
 BOTH TERMINAL ISLANDS SHALL COMPLY WITH THE NEW
 PROPOSED LENGTH OF PARKING STALL.
  
 RE-SUBMITTAL 2/12/09 - THE DRAWINGS WERE NOT REVISED,
 HOWEVER THE PROVISO IS THAT THESE EXISTING TERMINAL
 ISLANDS SHALL BE RECONFIGURED TO BE THE SAME DEPTH OF
 THE PARKING STALL (18 FEET IS SHOWN), THE PLANS HAVE
 BEEN NOTED WITH THE PROVISO.
  
 3. PROVISO: SHEET A-8 SHOWS DETAIL "A" WITH AN
 ERRONEOUS NOTATION REFERRING TO DETAIL "C". IT HAS BEEN
 REVISED ON PLANS TO COINCIDE WITH DETAIL "E", WHICH IS
 THE DETAIL FOR THE TRUNCATED DOMES.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME AT THE
 NUMBER BELOW.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2009-01-09 Cont ID  
Sent By lfranco Date 2009-01-09 Time 17:26 Rev Time 0.00
Received By lfranco Date 2009-01-09 Time 17:26 Sent To B
Notes
2009-01-09 18:55:58PLANNING AND ZONING: **** FAILED ****
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. SHEET A-5 SHOWS THE ACCESSIBLE PARKING SIGNAGE BEING
 REMOUNTED. PROVIDE DETAIL SHOWING AMPLE ROOM FOR CAR
 OVERHANG WITHOUT INTERFERENCE WITH THE SIGN. FOR
 EXAMPLE, IF THERE IS A WHEEL STOP LOCATED TWO (2) FEET
 FROM THE BACK OF THE WHEEL STOP AND CURB/SIDEWALK AND
 THE PARKING IS 18 FEET IN DEPTH, THEN THAT WILL COMPLY.
 OTHERWISE SHOW TOTAL DIMENSION OF PARKING DEPTH TO SHOW
 ACCOMMODATION FOR CAR OVERHANG. PLEASE SEE ATTACHED
 PARKING DETAILS FOR YOUR REFERENCE.
  
 RESPONSE TO RE-SUBMITTAL:
  
 REVISE THE TWO (2) FOOT DIMENSION TO BE BETWEEN THE
 BACK OF THE WHEEL STOP TO THE EDGE OF CURBING/SIDEWALK
 WHATEVER IS APPLICABLE. THE DIMENSION SHOWS FROM THE
 FRONT OF THE WHEEL STOP.
  
 3. SHEET A-4 DETAIL 4 - REVISE THE TWO (2) FOOT
 DIMENSION TO BE BETWEEN THE BACK OF THE WHEEL STOP TO
 THE EDGE OF CURBING/SIDEWALK WHATEVER IS APPLICABLE.
 THE DIMENSION SHOWS FROM THE FRONT OF THE WHEEL STOP.
  
 4. SHEET A-6 VIEW 7 - PURSUANT TO THE ZONING AND LAND
 DEVELOPMENT REGULATION ("ZLDR") SECTION 94-443(C)(3)A -
 TERMINAL ISLANDS. EACH ROW OF PARKING SPACES SHALL BE
 TERMINATED BY LANDSCAPED ISLANDS OF NOT LESS THAN FIVE
 FEET IN WIDTH AND NOT LESS THAN THE LENGTH OF THE
 ADJACENT PARKING STALL. THE LANDSCAPED ISLAND SHALL
 HAVE A MINIMUM RADIUS OF 2 1/2 FEET AT ITS END SO AS TO
 ALLOW CAR MANEUVERING. THE LANDSCAPED ISLAND SHALL
 CONTAIN AT LEAST ONE SHADE OR FLOWERING TREE.
  
 ** THE PROPOSED FLARED RAMP IS WITHIN THIS REQUIRED
 LANDSCAPED TERMINAL ISLAND, WHICH IS NOT ALLOWED.
  
  
 5. SHEET A-7 SHOWS PROPOSED VIEW #8 WITH THE PARKING
 STALL DEPTH INCREASING. AS A RESULT, THE EXISTING
 TERMINAL ISLANDS ARE LESS THAN THE ADJACENT PARKING
 STALL (PURSUANT TO SECTION 94-443(C)(3)A), THEREFORE,
 BOTH TERMINAL ISLANDS SHALL COMPLY WITH THE NEW
 PROPOSED LENGTH OF PARKING STALL.
  
 6. SHEET A-8 - DETAIL "B & D" - REVISE THE TWO (2) FOOT
 DIMENSIONS TO BE BETWEEN THE BACK OF THE WHEEL STOP TO
 THE EDGE OF CURBING/SIDEWALK/EDGE OF PARKING STALL,
 WHATEVER IS APPLICABLE. THE DIMENSION SHOWS FROM THE
 FRONT OF THE WHEEL STOP. ALSO:
  
 A. ADD NOTATION BASED ON COMMENT 7 BELOW, THAT THE
 OUTER LINE OF THE ACCESSIBLE AISLE TO BE BLUE AS NOTED
 ON THE DETAIL INCLUDED IN THE PAST REVIEW.
 B. THE UNIVERSAL SYMBOL SHALL BE A MINIMUM OF TWO (2)
 FEET FROM THE BOTTOM EDGE OF THE STRIPPING.
 C. DETAIL "B" - DIMENSION SYMBOL OF 12 FEET IS NOT
 MEASURED AT CENTERLINE TO CENTERLINE.
  
 7. THE ACCESSIBLE PARKING (ATTACHED DETAIL INCLUDED)
 AND PARKING DETAILS DO NOT COMPLY WITH ZONING AND LAND
 DEVELOPMENT REGULATIONS ("ZLDR"), REVISE ACCORDINGLY.
  
 8. PROVIDE NOTATION AT ALL INTERSECTION/CROSS WALKS
 WHERE ACCESSIBLE PATH IS SEPARATED BY VEHICULAR PATHWAY
 AREAS ON SITE PLAN AND SHEETS WHERE SPECIFIC "VIEW"
 AREAS (ENLARGED DETAILED AREAS) ACCORDINGLY (AS SHOWN
 ON SHEET A-8 DETAIL "E" - DETECTABLE WARNINGS,
 TRUNCATED DOMES).
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME AT THE
 NUMBER BELOW.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2008-11-13 Cont ID  
Sent By lfranco Date 2008-11-13 Time 16:53 Rev Time 0.00
Received By lfranco Date 2008-11-13 Time 16:53 Sent To  
Notes
2008-11-13 18:08:55PLANNING AND ZONING: **** FAILED ****
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. SHEET A-4, BOTH PET STORE AND HAVERTY'S CROSSWALK
 DETAILS SHOW THE NEW CROSSWALK RUNNING/CUTTING INTO THE
 TERMINAL LANDSCAPE ISLANDS. REVISE ACCORDINGLY.
  
 3. SHEET A-5 SHOWS THE ACCESSIBLE PARKING SIGNAGE BEING
 REMOUNTED. PROVIDE DETAIL SHOWING AMPLE ROOM FOR CAR
 OVERHANG WITHOUT INTERFERENCE WITH THE SIGN. FOR
 EXAMPLE, IF THERE IS A WHEEL STOP LOCATED TWO (2) FEET
 FROM THE BACK OF THE WHEEL STOP AND CURB/SIDEWALK AND
 THE PARKING IS 18 FEET IN DEPTH, THEN THAT WILL COMPLY.
 OTHERWISE SHOW TOTAL DIMENSION OF PARKING DEPTH TO SHOW
 ACCOMMODATION FOR CAR OVERHANG. PLEASE SEE ATTACHED
 PARKING DETAILS FOR YOUR REFERENCE.
  
 4. SHEET A-7 SHOWS PROPOSED VIEW #8 WITH THE PARKING
 STALL DEPTH INCREASING. AS A RESULT, THE PARKING DRIVE
 AISLE HAS BEEN REDUCED TO LESS THAN 24 FEET. PURSUANT
 TO SECTION 94-485(J)(2) THIS PROPOSAL DOES NOT COMPLY
 WITH MINIMUM WIDTH STANDARDS FOR DRIVE AISLES, SEE
 FIGURE XV-2. ADDITIONALLY, SHOW THE LOCATION OF WHEEL
 STOPS, IF APPLICABLE TO SHOW WHERE CAR OVERHANG WILL
 BE. THE RE-STRIPPING OF THE PARKING STALLS SHALL MEET
 THE ATTACHED PARKING DETAIL, INCLUDING PAINT STRIPPING
 DETAILS.
  
 5. SHEET A-8 - DETAIL "D" SHOWS TO ACCESSIBLE PARKING
 SPACES IN FRONT OF EACH OTHER WITH A SIGN IN BETWEEN.
 THE MINIMUM PARKING STALL DEPTH IS 18 FEET, INCLUDES A
 WHEEL STOP FOR A TWO (2) CAR OVERHANG. THE PROPOSED
 DETAIL DOES NOT COMPLY.
  
 6. THE ACCESSIBLE PARKING (ATTACHED DETAIL INCLUDED)
 AND PARKING DETAILS DO NOT COMPLY WITH ZONING AND LAND
 DEVELOPMENT REGULATIONS ("ZLDR"), REVISE ACCORDINGLY.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME AT THE
 NUMBER BELOW.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  